• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

"Análise 'in vitro'da rugosidade superficial apresentada pelas porcelanas omega 900 e vitadur alpha após a utilização de três diferentes sistemas de polimento" / Omega 900 e vitadur alpha ceramics using three different polishing systems

Araujo, Jesuina Lamartine Nogueira 25 June 2003 (has links)
RESUMO A qualidade da superfície de trabalhos cerâmicos que requer ajuste durante a sua adaptação ao remanescente dentário desperta a atenção durante os procedimentos odontológicos restauradores estéticos. Observa-se a necessidade freqüente de realizar desgastes superficiais nas restaurações cerâmicas, sendo que a preservação de uma superfície lisa é importante para as propriedades destes materiais, bem como para o seu comportamento clínico. Este trabalho propõe-se a avaliar a técnica com maior capacidade de polimento da superfície cerâmica asperizada, através da medição com ponta apalpadora de um rugosímetro, e utilizando o MEV para observações visuais com relação às técnicas empregadas. Para tal 80 corpos-de-prova foram confeccionados utilizando-se as porcelanas Omega 900 e Vitadur Alpha, constituindo quatro grupos experimentais: A – glaze (controle); B – polimento com borrachas abrasivas da DFL mais pasta para polimento da KOTA; C – polimento com borrachas abrasivas mais rodas de feltro mais pasta para polimento Porcelize (Cosmedent); D – polimento com borrachas abrasivas mais pasta porcelize mais discos Flexibuff mais pasta diamantada para brilho Enamelize (Cosmedent). Os dados receberam tratamento estatístico por meio da Análise de variância (ANOVA) e teste de Tukey, o qual indicou haver diferença estatisticamente significante entre os tipos de polimento para os quais as porcelanas foram submetidas, e na interação porcelana / polimento. Os resultados sugerem que todos os tratamentos polidores diminuem a rugosidade superficial das porcelanas em relação ao grupo controle e que dependendo da porcelana utilizada para cada técnica pode-se ter uma variação na rugosidade superficial. Quanto à observação pelo microscópio eletrônico de varredura houve uma correlação parcial entre este e os resultados obtidos pelo rugosímetro, pois aqui a porcelana Omega 900 mostrou-se mais polida no grupo controle, enquanto que na análise pelo rugosímetro apontou para a técnica polidora do Grupo D como sendo aquela que produziu uma superfície mais lisa para esta porcelana. Por outro lado, mostrou que o melhor polimento alcançado pela porcelana Vitadur Alpha foi através do polimento do Grupo C, o que está de acordo com os resultados obtidos pelo rugosímetro. / SUMMARY Aesthetic dentistry uses materials that can copy some lost caractheristics of the natural dentition, as color, mechanical resistance and smoothness.The better material for this are the ceramics. On the other hand, it is commum to have to grind them with diamond instruments for adjustment wich removes the glazed surfaces. This procedure can cause abrasion of the opposite teeth, plaque retention, injury of surrounding tissues and low aesthetics qualities. This study evaluated the roughness average in two dental ceramics, Omega 900 e Vitadur Alpha, that were grinding with diamond instruments after the glaze technique, and received three different polishing systems. The control group remained glazed until the end of the research. The groups were: Group A – control; Group B – grinding by fine and ultrafine points + polishing with DFL rubber points + KOTA diamond paste; Group C –grinding by fine and ultrafine points + polishing with rubber points + felt discs + Porcelize diamond paste (Cosmedent); Group D - grinding by fine and ultrafine points + polishing with rubber points + Porcelize + Flexibuff discs + Enamelize polishing paste (Cosmedent). To measure the roughness average in the samples it was used a profilometer Surftest SV-600 with the software Surfpack and the images were observed in the scanning electron microscopy (SEM) to comparation. The results received estatistical analysis using ANOVA and Tukey test (p˜0.05), and a significant tatistical difference was observed between the polishing systems , and in the porcelain/polishing interaction, which showed that all the polishing systems decreased the surface roughness of the porcelains after been grinding with diamond instruments, which was a better result than the control group. In the SEM analysis it was clear the presence of a partial relationship between the profilometer and that one, because here the Omega porcelain showed a more smoothness surface with the glazed treatment compaired with the others, differently from the profilometer analysis
2

Estudo de um sistema de medição a laser na análise da textura da superfície gerada por torneamento

Marchiori, Marcelo Mennet January 2013 (has links)
A determinação da rugosidade é parte fundamental para a classificação da qualidade de uma superfície. Assim, iniciou-se este trabalho realizando-se estudos a respeito de seus métodos de medição. Devido à grande adaptabilidade e à velocidade dos métodos a laser, os estudos foram direcionados para estes tipos de técnicas de medição. Verificou-se que esses dispositivos vinculavam-se a sistemas em que o laser refletido era analisado através de sistemas com detectores do tipo CCD, em que a imagem refletida era analisada num todo. Assim, a bibliografia trouxe inspiração para mensurar a rugosidade de uma superfície gerada por torneamento horizontal, a partir da intensidade laser refletida. Propôs-se, então, um método baseado exclusivamente, na intensidade do sinal que era refletido pela superfície em estudo, a contar de uma incidência normal, já que aos autores ressaltavam que quanto maior a rugosidade da superfície menor seria o sinal refletido por ela. O sistema foi montado e sua capacidade de diferenciar distintas rugosidades foi testada. Então foram produzidas amostras com diferentes rugosidades, a fim de se obter uma função que pudesse correlacionar o sinal laser com a respectiva rugosidade (medida esta feita em rugosímetro de agulha). A função de transferência encontrada foi testada em amostras dissemelhantes das que a geraram, com o intuito de comprovar sua eficácia. Amostras fabricadas com ferramentas distintas de corte também foram produzidas e submetidas ao mesmo procedimento. As funções de transferência geradas alcançaram sucesso na previsão da rugosidade em, no máximo, 16,6% dos pontos, considerando uma margem de erro de 20%. A seguir, procurando-se os motivos que pudessem ter causado este percentual, levantou-se a possibilidade de estarem ocorrendo efeitos ópticos capazes de causar interferências devido às irregularidades na superfície. Efeitos capazes de degenerarem o sinal refletido. A comprovação de que o sinal eventualmente poderia estar sendo perturbado aconteceu através de referência bibliográfica e de imagens obtidas por microscopia eletrônica de varredura, em que se pôde observar a existência de estruturas na face das amostras que seriam isolada ou conjuntamente capazes de causar os efeitos citados. / The determination of the roughness is a key for a good classification of a surface. Thereby, the work was started with a study about the roughness measurements methods. Due to the great adaptability and speed of laser methods, the studies were directed to these kinds of measurement techniques. It was observed in the literature that these laser devices were linked to systems where the reflected laser was analyzed by systems with CCD detectors, where the reflected image was entirely analyzed. Hence, the bibliography brought inspiration to measure the surface roughness generated by axial turning from the intensity of the reflected laser. It was proposed then a measurement method exclusively based on the intensity of the signal that was reflected by the surface under study, because the authors noted that as the roughness of surface became bigger as the signal reflected is became smaller. The proposed system has been assembled and ability to distinguish different roughness was tested successfully. Then samples were produced with different roughness in order to obtain a function that would correlate the laser signal with its roughness (this measurement is made by tactile measurement instrument). The transfer function obtained was tested on different samples that generated in order to prove its efficacy. Samples produced with different cutting tools were also produced and subjected to the same procedure. The transfer functions reached a successful prediction of the roughness maximum for 16.6% of the points assuming a margin of error of 20%. So, looking up the reasons that could have caused this percentage we think the possibility as the occurrence of some optical effects that can cause interference due to irregularities on the surface. These optical effects can degenerate the reflected signal. The proof that the signal could possibly be corrupted was made by the bibliographic references and some images obtained by scanning electron microscopy in which they could observe the existence of structures on the sample surfaces that would can be a reason for these effects individually or together.
3

Estudo de um sistema de medição a laser na análise da textura da superfície gerada por torneamento

Marchiori, Marcelo Mennet January 2013 (has links)
A determinação da rugosidade é parte fundamental para a classificação da qualidade de uma superfície. Assim, iniciou-se este trabalho realizando-se estudos a respeito de seus métodos de medição. Devido à grande adaptabilidade e à velocidade dos métodos a laser, os estudos foram direcionados para estes tipos de técnicas de medição. Verificou-se que esses dispositivos vinculavam-se a sistemas em que o laser refletido era analisado através de sistemas com detectores do tipo CCD, em que a imagem refletida era analisada num todo. Assim, a bibliografia trouxe inspiração para mensurar a rugosidade de uma superfície gerada por torneamento horizontal, a partir da intensidade laser refletida. Propôs-se, então, um método baseado exclusivamente, na intensidade do sinal que era refletido pela superfície em estudo, a contar de uma incidência normal, já que aos autores ressaltavam que quanto maior a rugosidade da superfície menor seria o sinal refletido por ela. O sistema foi montado e sua capacidade de diferenciar distintas rugosidades foi testada. Então foram produzidas amostras com diferentes rugosidades, a fim de se obter uma função que pudesse correlacionar o sinal laser com a respectiva rugosidade (medida esta feita em rugosímetro de agulha). A função de transferência encontrada foi testada em amostras dissemelhantes das que a geraram, com o intuito de comprovar sua eficácia. Amostras fabricadas com ferramentas distintas de corte também foram produzidas e submetidas ao mesmo procedimento. As funções de transferência geradas alcançaram sucesso na previsão da rugosidade em, no máximo, 16,6% dos pontos, considerando uma margem de erro de 20%. A seguir, procurando-se os motivos que pudessem ter causado este percentual, levantou-se a possibilidade de estarem ocorrendo efeitos ópticos capazes de causar interferências devido às irregularidades na superfície. Efeitos capazes de degenerarem o sinal refletido. A comprovação de que o sinal eventualmente poderia estar sendo perturbado aconteceu através de referência bibliográfica e de imagens obtidas por microscopia eletrônica de varredura, em que se pôde observar a existência de estruturas na face das amostras que seriam isolada ou conjuntamente capazes de causar os efeitos citados. / The determination of the roughness is a key for a good classification of a surface. Thereby, the work was started with a study about the roughness measurements methods. Due to the great adaptability and speed of laser methods, the studies were directed to these kinds of measurement techniques. It was observed in the literature that these laser devices were linked to systems where the reflected laser was analyzed by systems with CCD detectors, where the reflected image was entirely analyzed. Hence, the bibliography brought inspiration to measure the surface roughness generated by axial turning from the intensity of the reflected laser. It was proposed then a measurement method exclusively based on the intensity of the signal that was reflected by the surface under study, because the authors noted that as the roughness of surface became bigger as the signal reflected is became smaller. The proposed system has been assembled and ability to distinguish different roughness was tested successfully. Then samples were produced with different roughness in order to obtain a function that would correlate the laser signal with its roughness (this measurement is made by tactile measurement instrument). The transfer function obtained was tested on different samples that generated in order to prove its efficacy. Samples produced with different cutting tools were also produced and subjected to the same procedure. The transfer functions reached a successful prediction of the roughness maximum for 16.6% of the points assuming a margin of error of 20%. So, looking up the reasons that could have caused this percentage we think the possibility as the occurrence of some optical effects that can cause interference due to irregularities on the surface. These optical effects can degenerate the reflected signal. The proof that the signal could possibly be corrupted was made by the bibliographic references and some images obtained by scanning electron microscopy in which they could observe the existence of structures on the sample surfaces that would can be a reason for these effects individually or together.
4

"Análise 'in vitro'da rugosidade superficial apresentada pelas porcelanas omega 900 e vitadur alpha após a utilização de três diferentes sistemas de polimento" / Omega 900 e vitadur alpha ceramics using three different polishing systems

Jesuina Lamartine Nogueira Araujo 25 June 2003 (has links)
RESUMO A qualidade da superfície de trabalhos cerâmicos que requer ajuste durante a sua adaptação ao remanescente dentário desperta a atenção durante os procedimentos odontológicos restauradores estéticos. Observa-se a necessidade freqüente de realizar desgastes superficiais nas restaurações cerâmicas, sendo que a preservação de uma superfície lisa é importante para as propriedades destes materiais, bem como para o seu comportamento clínico. Este trabalho propõe-se a avaliar a técnica com maior capacidade de polimento da superfície cerâmica asperizada, através da medição com ponta apalpadora de um rugosímetro, e utilizando o MEV para observações visuais com relação às técnicas empregadas. Para tal 80 corpos-de-prova foram confeccionados utilizando-se as porcelanas Omega 900 e Vitadur Alpha, constituindo quatro grupos experimentais: A – glaze (controle); B – polimento com borrachas abrasivas da DFL mais pasta para polimento da KOTA; C – polimento com borrachas abrasivas mais rodas de feltro mais pasta para polimento Porcelize (Cosmedent); D – polimento com borrachas abrasivas mais pasta porcelize mais discos Flexibuff mais pasta diamantada para brilho Enamelize (Cosmedent). Os dados receberam tratamento estatístico por meio da Análise de variância (ANOVA) e teste de Tukey, o qual indicou haver diferença estatisticamente significante entre os tipos de polimento para os quais as porcelanas foram submetidas, e na interação porcelana / polimento. Os resultados sugerem que todos os tratamentos polidores diminuem a rugosidade superficial das porcelanas em relação ao grupo controle e que dependendo da porcelana utilizada para cada técnica pode-se ter uma variação na rugosidade superficial. Quanto à observação pelo microscópio eletrônico de varredura houve uma correlação parcial entre este e os resultados obtidos pelo rugosímetro, pois aqui a porcelana Omega 900 mostrou-se mais polida no grupo controle, enquanto que na análise pelo rugosímetro apontou para a técnica polidora do Grupo D como sendo aquela que produziu uma superfície mais lisa para esta porcelana. Por outro lado, mostrou que o melhor polimento alcançado pela porcelana Vitadur Alpha foi através do polimento do Grupo C, o que está de acordo com os resultados obtidos pelo rugosímetro. / SUMMARY Aesthetic dentistry uses materials that can copy some lost caractheristics of the natural dentition, as color, mechanical resistance and smoothness.The better material for this are the ceramics. On the other hand, it is commum to have to grind them with diamond instruments for adjustment wich removes the glazed surfaces. This procedure can cause abrasion of the opposite teeth, plaque retention, injury of surrounding tissues and low aesthetics qualities. This study evaluated the roughness average in two dental ceramics, Omega 900 e Vitadur Alpha, that were grinding with diamond instruments after the glaze technique, and received three different polishing systems. The control group remained glazed until the end of the research. The groups were: Group A – control; Group B – grinding by fine and ultrafine points + polishing with DFL rubber points + KOTA diamond paste; Group C –grinding by fine and ultrafine points + polishing with rubber points + felt discs + Porcelize diamond paste (Cosmedent); Group D - grinding by fine and ultrafine points + polishing with rubber points + Porcelize + Flexibuff discs + Enamelize polishing paste (Cosmedent). To measure the roughness average in the samples it was used a profilometer Surftest SV-600 with the software Surfpack and the images were observed in the scanning electron microscopy (SEM) to comparation. The results received estatistical analysis using ANOVA and Tukey test (p˜0.05), and a significant tatistical difference was observed between the polishing systems , and in the porcelain/polishing interaction, which showed that all the polishing systems decreased the surface roughness of the porcelains after been grinding with diamond instruments, which was a better result than the control group. In the SEM analysis it was clear the presence of a partial relationship between the profilometer and that one, because here the Omega porcelain showed a more smoothness surface with the glazed treatment compaired with the others, differently from the profilometer analysis
5

Estudo de um sistema de medição a laser na análise da textura da superfície gerada por torneamento

Marchiori, Marcelo Mennet January 2013 (has links)
A determinação da rugosidade é parte fundamental para a classificação da qualidade de uma superfície. Assim, iniciou-se este trabalho realizando-se estudos a respeito de seus métodos de medição. Devido à grande adaptabilidade e à velocidade dos métodos a laser, os estudos foram direcionados para estes tipos de técnicas de medição. Verificou-se que esses dispositivos vinculavam-se a sistemas em que o laser refletido era analisado através de sistemas com detectores do tipo CCD, em que a imagem refletida era analisada num todo. Assim, a bibliografia trouxe inspiração para mensurar a rugosidade de uma superfície gerada por torneamento horizontal, a partir da intensidade laser refletida. Propôs-se, então, um método baseado exclusivamente, na intensidade do sinal que era refletido pela superfície em estudo, a contar de uma incidência normal, já que aos autores ressaltavam que quanto maior a rugosidade da superfície menor seria o sinal refletido por ela. O sistema foi montado e sua capacidade de diferenciar distintas rugosidades foi testada. Então foram produzidas amostras com diferentes rugosidades, a fim de se obter uma função que pudesse correlacionar o sinal laser com a respectiva rugosidade (medida esta feita em rugosímetro de agulha). A função de transferência encontrada foi testada em amostras dissemelhantes das que a geraram, com o intuito de comprovar sua eficácia. Amostras fabricadas com ferramentas distintas de corte também foram produzidas e submetidas ao mesmo procedimento. As funções de transferência geradas alcançaram sucesso na previsão da rugosidade em, no máximo, 16,6% dos pontos, considerando uma margem de erro de 20%. A seguir, procurando-se os motivos que pudessem ter causado este percentual, levantou-se a possibilidade de estarem ocorrendo efeitos ópticos capazes de causar interferências devido às irregularidades na superfície. Efeitos capazes de degenerarem o sinal refletido. A comprovação de que o sinal eventualmente poderia estar sendo perturbado aconteceu através de referência bibliográfica e de imagens obtidas por microscopia eletrônica de varredura, em que se pôde observar a existência de estruturas na face das amostras que seriam isolada ou conjuntamente capazes de causar os efeitos citados. / The determination of the roughness is a key for a good classification of a surface. Thereby, the work was started with a study about the roughness measurements methods. Due to the great adaptability and speed of laser methods, the studies were directed to these kinds of measurement techniques. It was observed in the literature that these laser devices were linked to systems where the reflected laser was analyzed by systems with CCD detectors, where the reflected image was entirely analyzed. Hence, the bibliography brought inspiration to measure the surface roughness generated by axial turning from the intensity of the reflected laser. It was proposed then a measurement method exclusively based on the intensity of the signal that was reflected by the surface under study, because the authors noted that as the roughness of surface became bigger as the signal reflected is became smaller. The proposed system has been assembled and ability to distinguish different roughness was tested successfully. Then samples were produced with different roughness in order to obtain a function that would correlate the laser signal with its roughness (this measurement is made by tactile measurement instrument). The transfer function obtained was tested on different samples that generated in order to prove its efficacy. Samples produced with different cutting tools were also produced and subjected to the same procedure. The transfer functions reached a successful prediction of the roughness maximum for 16.6% of the points assuming a margin of error of 20%. So, looking up the reasons that could have caused this percentage we think the possibility as the occurrence of some optical effects that can cause interference due to irregularities on the surface. These optical effects can degenerate the reflected signal. The proof that the signal could possibly be corrupted was made by the bibliographic references and some images obtained by scanning electron microscopy in which they could observe the existence of structures on the sample surfaces that would can be a reason for these effects individually or together.

Page generated in 0.0893 seconds