• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Développement d'un protocole expérimental pour la simulation en laboratoire de l'usure et de la perte d'adhérence des chaussées en béton

Liegeois, Alexandre 20 March 2024 (has links)
Titre de l'écran-titre (visionné le 18 mars 2024) / Au Québec, les chaussées en béton perdent rapidement leur adhérence au fil du temps. C'est pourquoi le ministère des Transports et de la mobilité durable du Québec souhaite identifier une ou des formulation(s) de béton qui résiste(nt) bien au phénomène d'usure et de perte d'adhérence prématurée. L'objectif de ce projet est de créer un protocole expérimental permettant de reproduire en laboratoire l'usure et la perte d'adhérence des chaussées en béton, et ce de façon fiable et relativement rapide. Un tel protocole permettra en effet d'évaluer la performance, face à l'usure, de différentes formulations de béton incorporant une variété de granulats grossier et fin, de même que différentes matrices cimentaires. Ce mémoire présente une revue des différents types de chaussées en béton utilisées au Québec ainsi que les différents moyens existants pour effectuer le suivi de leur adhérence au fil du temps. Ensuite, il décrit des interventions sur le terrain visant à mesurer, à l'aide d'appareils spécifiques, l'adhérence des routes en béton. Enfin, il présente le calibrage du *Three-Wheel Polishing Device* (TWPD) permettant de conditionner en laboratoire des dalles de béton. Ce processus de conditionnement s'accompagne de la mise en place de différents moyens de mesure, de l'usure et de l'adhérence, en passant par le frottement et le profil des dallettes. Finalement, le protocole développé dans le cadre de ce projet permet d'obtenir des écarts significatifs de macro-texture entre des dalles incorporant deux gros granulats de nature très différente, soit un granulat granitique et un granulat dolomitique. Il entraîne une profondeur d'usure de 2 mm, ce qui permet d'observer des différences visuelles entre les différentes formulations de béton. Ce protocole peut être réalisé par une personne, avec un rythme d'un mélange de béton par semaine. / In Quebec, concrete pavements quickly lose their grip over time. This is why the Quebec Ministry of Transport and Sustainable Mobility wants to identify a concrete mix that does not present problems with wear and premature loss of adhesion. The objective of this project is to create an experimental protocol allowing the wear and loss of grip of concrete pavements to be reproduced in the laboratory, reliably and relatively quickly. Such a protocol will indeed make it possible to evaluate the performance, in the face of wear, of different concrete formulations incorporating a variety of coarse and fine aggregates, as well as different cement matrices. This MSc dissertation presents a review of the different types of concrete pavements used in Quebec as well as the different existing means of measuring their adhesion. Then, it describes field interventions aimed at measuring, using specific devices, the skid resistance of concrete roads in the Montreal region. Finally, it presents the calibration of the Three-Wheel Polishing Device (TWPD) for conditioning concrete slabs in the laboratory. This conditioning process is accompanied by the implementation of different means of measurement, from wear and adhesion, to friction and the profile of the slabs. Finally, the protocol developed as part of this project makes it possible to obtain significant differences in macro-texture between slabs incorporating two large aggregates of very different nature, namely a granite aggregate and a dolomitic aggregate. It results in a wear depth of 2 mm, which allows visual differences to be observed between different concrete mixes. This protocol can be carried out by one person, with a rate of one concrete mixture per week.
2

Performance et robustesse des matériaux de réparation à prise rapide et/ou à haute résistance initiale

Durand, Vanessa 19 April 2018 (has links)
Au Québec, plusieurs ouvrages d'art et infrastructures routières en béton sont en mauvais état en raison d'un manque d'entretien combiné aux effets d'un climat rigoureux. Pour continuer à offrir aux usagers un service sécuritaire tout en minimisant les délais et interruptions, les gestionnaires doivent souvent recourir à des techniques et matériaux permettant des interventions rapides. Ainsi on fait régulièrement appel à des matériaux de réparation à prise rapide et/ou à haute résistance initiale. Malheureusement, ces matériaux présentent parfois des problèmes de fiabilité, notamment sur le plan rhéologique et du point de vue de la durabilité. Dans le projet faisant l'objet du présent mémoire, des essais ciblés ont été effectués sur une sélection de matériaux en vue d'en caractériser la performance et la robustesse. Il a été démontré que certaines catégories de matériaux peuvent offrir la robustesse recherchée, mais que leur sélection doit être effectuée en regard des conditions d'utilisation et d'exposition, en particulier celles prévalant lors de l'intervention. Les recommandations sont faites pour les 3 grandes catégories de matériaux, en fonction du délai avant une remise en service. En deçà de 3 heures, les mortiers de ciment d'aluminate de calcium (CAC) et mortiers étendus de ciment de phosphate de magnésium (PMG-E) sont les meilleures options. Pour les mélanges avec accélérateurs de prise et une remise en service entre 8 et 24 heures, le mélange sans chlorure (SA) s'avère être une bonne option. Pour les matériaux de type HE (ciment à haute résistance initiale) et une remise en service variant de 12 à 20 heures, le HE1 se révèle être une option envisageable. Ces conclusions sont faites suite à l'analyse des résultats des divers essais et températures étudiés ainsi que les composantes et paramètres utilisés.

Page generated in 0.071 seconds