• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 20
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da dissolução de vidros niobofosfato em água e em solução simuladora de fluído fisiológico / Evaluation of the dissolution rate of niobium phosphate glasses in water and simulated body fluid solution

Zerlim, Anelisa 15 August 2008 (has links)
A busca pelo prolongamento da qualidade da vida tem incentivado o aparecimento de novos materiais. Vidros que possuem fosfato em sua composição têm encontrado um grande espaço em aplicações como biomateriais, e sua utilização como scaffolds pode ser promissora, pois além de sua estrutura ser mais próxima da parte mineral dos tecidos ósseos, eles são materiais com alta solubilidade em meios aquosos. Vidros niobofosfato foram estudados em trabalhos anteriores e provou-se que a adição de óxido de nióbio em vidros fosfato melhora sua durabilidade química. Há também estudos que revelam que o óxido de nióbio pode ser utilizado como biomaterial devido a sua biocompatibilidade. Neste trabalho determinou-se a taxa de dissolução de uma ampla faixa de composições de vidros niobofosfato em soluções aquosas, e em soluções simuladoras de fluído corpóreo (SBF), com diferentes condições de ensaio. Os vidros estudados neste trabalho com composições (32 - 37)P2O5 (2- 15)Nb2O5 (6-7)Na2O (46-53)CaO, % em mol, foram produzidos a partir da mistura e fusão dos precursores em forno elétrico na faixa de temperatura de 1300ºC - 1400ºC por 0,3h. Foram produzidos sete tipos de vidros com composições diferentes, tendo como base a variação do teor de óxido de nióbio. Os vidros foram submetidos a análises de citotoxicidade e foram considerados não citotóxicos. Análises por difração de raios X mostraram que os materiais são amorfos e não se observou a presença de fases cristalinas após imersão tanto em solução aquosa, quanto em SBF. A densidade dos vidros variou de 2,84 a 3,14 g/cm3 em função do teor de óxido de nióbio. Observou-se a perda de massa dos vidros imersos em água e em SBF a 37ºC por 21 dias, sendo que a taxa de dissolução é maior quanto menor o teor de nióbio. As taxas de dissolução também variam de acordo com as condições de imersão das amostras. Micrografias eletrônicas de varredura mostraram a superfície das amostras antes e após imersão. Observou-se a formação de trincas nas superfícies de algumas amostras, resultado da liberação de matéria para o meio lixiviante. Houve aparente formação de uma camada superficial em uma determinada composição. Análises por espectrometria de fluorescência de raios X por energia dispersiva (EDX) determinaram os teores dos elementos presentes nas composições dos vidros, antes e após as imersões. Observou-se a presença de Al2O3, resultado da contaminação do vidro pelo cadinho, e também uma variação significativa no teor de P2O5 causado pela volatilização do mesmo no processo de obtenção do vidro. A variação dos teores dos elementos na superfície de alguns vidros após os períodos de imersão é causada principalmente pela liberação preferencial de P, Na, Al. Os teores dos elementos P, Na, Nb e Ca foram determinados por EDX nas soluções aquosas utilizadas para os testes de lixiviação. / The need to extend and improve the quality of life is leading to the search of new materials. Glasses containing phosphorous in their compositions are considered biomaterials and can be used as scaffolds because they have a structure close to the mineral component of bone tissues, and present relatively high solubility in water. The chemical composition, morphology, and mechanical properties of bioactive glasses can be properly fit to allow bonding with bones. Niobium phosphate glasses have been previously investigated. The addition of niobium oxide improves the chemical durability of phosphate glasses, and they are considered biocompatible. In the present work the dissolution rate of a wide range of niobium phosphate glass compositions were determined in water and Simulated Body Fluid (SBF). The glass compositions were in the range (32 - 37)P2O5 (2-15)Nb2O5 (6-7)Na2O (46-53)CaO mol%, and they were prepared by melting reagent grade chemical compounds in the temperature range 1300ºC - 1400ºC for 0.3h in an electrical furnace. Seven different glasses were prepared. The glasses were considered non-toxic after performing cytotoxicity tests. No evidence of crystalline phases was observed on X-rays diffraction patterns before and after the corrosion tests. The glass densities are in the range of 2.84 - 3.14 g/cm3. The density increases as the amount of niobium oxide increases. A mass loss was determined after immersing glass samples in water and in SBF at 37ºC during 21 days. The dissolution rate decreases as the amount of niobium oxide increases. The dissolution rate depends on the immersion medium and conditions. Cracks on the glass surfaces were observed by scanning electron microscopy after the corrosion tests which are related to the material release from the glass surface to the liquid. There is also evidence of formation of a layer on the surface of a specific glass composition. The glass compositions were determined before and after the corrosion tests by X-ray Fluorescence Spectrometry (EDS). Aluminum was detected in the glass composition. This element is related to the contamination of the glass by the crucible used in the glass melting. A significant variation of the amount of P2O5 compared to the nominal composition was also noticed, due to the volatilization of phosphorous during the glass melting. The surface glass composition changes during the leaching tests in water or SBF because of the preferential release of P, Na, and Al. EDS was also used to determine the concentration of P, Na, Nb, and Ca in the leaching solution by using the dry drop method.
2

Estudo da dissolução de vidros niobofosfato em água e em solução simuladora de fluído fisiológico / Evaluation of the dissolution rate of niobium phosphate glasses in water and simulated body fluid solution

Anelisa Zerlim 15 August 2008 (has links)
A busca pelo prolongamento da qualidade da vida tem incentivado o aparecimento de novos materiais. Vidros que possuem fosfato em sua composição têm encontrado um grande espaço em aplicações como biomateriais, e sua utilização como scaffolds pode ser promissora, pois além de sua estrutura ser mais próxima da parte mineral dos tecidos ósseos, eles são materiais com alta solubilidade em meios aquosos. Vidros niobofosfato foram estudados em trabalhos anteriores e provou-se que a adição de óxido de nióbio em vidros fosfato melhora sua durabilidade química. Há também estudos que revelam que o óxido de nióbio pode ser utilizado como biomaterial devido a sua biocompatibilidade. Neste trabalho determinou-se a taxa de dissolução de uma ampla faixa de composições de vidros niobofosfato em soluções aquosas, e em soluções simuladoras de fluído corpóreo (SBF), com diferentes condições de ensaio. Os vidros estudados neste trabalho com composições (32 - 37)P2O5 (2- 15)Nb2O5 (6-7)Na2O (46-53)CaO, % em mol, foram produzidos a partir da mistura e fusão dos precursores em forno elétrico na faixa de temperatura de 1300ºC - 1400ºC por 0,3h. Foram produzidos sete tipos de vidros com composições diferentes, tendo como base a variação do teor de óxido de nióbio. Os vidros foram submetidos a análises de citotoxicidade e foram considerados não citotóxicos. Análises por difração de raios X mostraram que os materiais são amorfos e não se observou a presença de fases cristalinas após imersão tanto em solução aquosa, quanto em SBF. A densidade dos vidros variou de 2,84 a 3,14 g/cm3 em função do teor de óxido de nióbio. Observou-se a perda de massa dos vidros imersos em água e em SBF a 37ºC por 21 dias, sendo que a taxa de dissolução é maior quanto menor o teor de nióbio. As taxas de dissolução também variam de acordo com as condições de imersão das amostras. Micrografias eletrônicas de varredura mostraram a superfície das amostras antes e após imersão. Observou-se a formação de trincas nas superfícies de algumas amostras, resultado da liberação de matéria para o meio lixiviante. Houve aparente formação de uma camada superficial em uma determinada composição. Análises por espectrometria de fluorescência de raios X por energia dispersiva (EDX) determinaram os teores dos elementos presentes nas composições dos vidros, antes e após as imersões. Observou-se a presença de Al2O3, resultado da contaminação do vidro pelo cadinho, e também uma variação significativa no teor de P2O5 causado pela volatilização do mesmo no processo de obtenção do vidro. A variação dos teores dos elementos na superfície de alguns vidros após os períodos de imersão é causada principalmente pela liberação preferencial de P, Na, Al. Os teores dos elementos P, Na, Nb e Ca foram determinados por EDX nas soluções aquosas utilizadas para os testes de lixiviação. / The need to extend and improve the quality of life is leading to the search of new materials. Glasses containing phosphorous in their compositions are considered biomaterials and can be used as scaffolds because they have a structure close to the mineral component of bone tissues, and present relatively high solubility in water. The chemical composition, morphology, and mechanical properties of bioactive glasses can be properly fit to allow bonding with bones. Niobium phosphate glasses have been previously investigated. The addition of niobium oxide improves the chemical durability of phosphate glasses, and they are considered biocompatible. In the present work the dissolution rate of a wide range of niobium phosphate glass compositions were determined in water and Simulated Body Fluid (SBF). The glass compositions were in the range (32 - 37)P2O5 (2-15)Nb2O5 (6-7)Na2O (46-53)CaO mol%, and they were prepared by melting reagent grade chemical compounds in the temperature range 1300ºC - 1400ºC for 0.3h in an electrical furnace. Seven different glasses were prepared. The glasses were considered non-toxic after performing cytotoxicity tests. No evidence of crystalline phases was observed on X-rays diffraction patterns before and after the corrosion tests. The glass densities are in the range of 2.84 - 3.14 g/cm3. The density increases as the amount of niobium oxide increases. A mass loss was determined after immersing glass samples in water and in SBF at 37ºC during 21 days. The dissolution rate decreases as the amount of niobium oxide increases. The dissolution rate depends on the immersion medium and conditions. Cracks on the glass surfaces were observed by scanning electron microscopy after the corrosion tests which are related to the material release from the glass surface to the liquid. There is also evidence of formation of a layer on the surface of a specific glass composition. The glass compositions were determined before and after the corrosion tests by X-ray Fluorescence Spectrometry (EDS). Aluminum was detected in the glass composition. This element is related to the contamination of the glass by the crucible used in the glass melting. A significant variation of the amount of P2O5 compared to the nominal composition was also noticed, due to the volatilization of phosphorous during the glass melting. The surface glass composition changes during the leaching tests in water or SBF because of the preferential release of P, Na, and Al. EDS was also used to determine the concentration of P, Na, Nb, and Ca in the leaching solution by using the dry drop method.
3

Multiple roles for the zebrafish transcriptional activator SBF/Staf

Halbig, Kari Michele 15 May 2009 (has links)
Eukaryotic transcriptional activators stimulate transcription of genes otherwise expressed at low levels. The typical activator operates by binding to specific sites on DNA with its activating region contacting the multiprotein machinery that directs transcription. SBF/Staf is a transcriptional activator that binds to the SPH element found in the promoters of genes for snRNAs and genes that code for mRNAs. SBF/Staf binds to SPH through a reiterated zinc finger DNA binding domain and also contains two distinct activation domains, one for snRNA genes and one for mRNA genes. To test the role of SBF/Staf in vivo, morpholino antisense oligos were used to knock down SBF/Staf expression in zebrafish. A high percentage of developing zebrafish embryos exhibited abnormalities. Co-injection of a synthetic mRNA construct rescued the morpholino-induced knockdown. Furthermore, both the mRNA and snRNA activation domains have significant roles in the function of SBF/Staf because when each domain was removed separately, partial rescue of the knockdown phenotype was obtained. When both domains were removed, no rescue of the phenotype was observed. Unexpectedly, knockdown of SBF/Staf expression in zebrafish embryos caused an increase in steady-state levels of all endogenous mRNAs tested, as well as transcripts produced from co-injected U6 maxigenes. However, quantitative RT-PCR analysis showed a relatively smaller increase in the steady-state levels of several mRNAs from genes that contain a SPH element in their promoters. In zebrafish U6 genes, the SPH element is in the unique location of being next to the TATA box, instead of ~220 bp upstream of the start site as in mammals. To determine the significance of the proximally-located SPH element for transcription of the zebrafish U6 snRNA gene, the SPH element was mutated. Transcription of a zebrafish U6 maxigene was reduced to 20.6% in transfected ZF4 cells and 26.8% in injected embryos, compared to that of the U6 maxigene with a normal promoter. This work indicates a more global role of SBF/Staf in mRNA gene transcription, instead of only activating the transcription of snRNA and a few mRNA genes, leading to an increased importance of the role of SBF/Staf in transcriptional control.
4

Multiple roles for the zebrafish transcriptional activator SBF/Staf

Halbig, Kari Michele 15 May 2009 (has links)
Eukaryotic transcriptional activators stimulate transcription of genes otherwise expressed at low levels. The typical activator operates by binding to specific sites on DNA with its activating region contacting the multiprotein machinery that directs transcription. SBF/Staf is a transcriptional activator that binds to the SPH element found in the promoters of genes for snRNAs and genes that code for mRNAs. SBF/Staf binds to SPH through a reiterated zinc finger DNA binding domain and also contains two distinct activation domains, one for snRNA genes and one for mRNA genes. To test the role of SBF/Staf in vivo, morpholino antisense oligos were used to knock down SBF/Staf expression in zebrafish. A high percentage of developing zebrafish embryos exhibited abnormalities. Co-injection of a synthetic mRNA construct rescued the morpholino-induced knockdown. Furthermore, both the mRNA and snRNA activation domains have significant roles in the function of SBF/Staf because when each domain was removed separately, partial rescue of the knockdown phenotype was obtained. When both domains were removed, no rescue of the phenotype was observed. Unexpectedly, knockdown of SBF/Staf expression in zebrafish embryos caused an increase in steady-state levels of all endogenous mRNAs tested, as well as transcripts produced from co-injected U6 maxigenes. However, quantitative RT-PCR analysis showed a relatively smaller increase in the steady-state levels of several mRNAs from genes that contain a SPH element in their promoters. In zebrafish U6 genes, the SPH element is in the unique location of being next to the TATA box, instead of ~220 bp upstream of the start site as in mammals. To determine the significance of the proximally-located SPH element for transcription of the zebrafish U6 snRNA gene, the SPH element was mutated. Transcription of a zebrafish U6 maxigene was reduced to 20.6% in transfected ZF4 cells and 26.8% in injected embryos, compared to that of the U6 maxigene with a normal promoter. This work indicates a more global role of SBF/Staf in mRNA gene transcription, instead of only activating the transcription of snRNA and a few mRNA genes, leading to an increased importance of the role of SBF/Staf in transcriptional control.
5

Hodnocení elektrochemických charakteristik tvářených hořčíkových slitin typu Mg-Al-Zn / Evaluation of electrochemical properties of wrought Mg-Al-Zn type magnesium alloys

Slouková, Karolína January 2016 (has links)
The aim of this master’s thesis is electrochemical characteristics evaluation of magnesium alloys. The theoretical part describes the properties of magnesium and its alloys and their corrosion characteristics. In the experimental part are presented results of corrosion resistance measurement of two types of wrought magnesium alloys. It was AZ31 and AZ61 magnesium alloys, which were measured in Hank’s solutions with addition of ions Ca2+ and Mg2+ (SBF+) and without addition of the ions (SBF). The solution temperature during the measurement was 37 ± 1 °C. The experiments were used electrochemical impedance spectroscopy (EIS) and potentiodynamic tests using linear polarization (LP). EIS measurements were done in times of 5 minutes, 1, 2, 4, 8, 12, 24, 48, 72, 96 and 168 hours. Potentiodynamic tests were only short-term and they started after 5 minutes of stabilization. Both methods were used for measuring the electrochemical characteristics of polished and ground surface of the samples. The most important measurement results were polarization resistance, corrosion potential and corrosion current density. The electrochemical measurements are used to estimate the chemical composition influence and alloy’s structure of the corrosion resistance.
6

Syntéza a vlastnosti biokompozitních materiálů s potenciálním využitím v medicíně / The Synthesis and Characterisation of Biocomposite Materials for Potential Application in Medicine

Balgová, Zuzana January 2014 (has links)
Dizertační práce se zabývala syntézou a studiem kompozitních materiálů pro potenciální lékařské využití. Teoretická část je zaměřena na biomateriály, zejména na kompozity složené z polyvinylalkoholu a hydroxyapatitu(PVA/HA). Byly připraveny kompozitní membrány složené z polyvinylalkoholu s různým hmotnostním zastoupením hydroxyapatitu - 0%, 10%, 20%, 30%, 40% a 50%. Hydroxyapatit (HA) byl připraven srážecí metodou z hydrogenfosforečnanu amonného a tetrahydrátu dusičnanu vápenatého ve vodném alkalickém prostředí. Vzniklá suspenze se smísila s roztokem polyvinylalkoholu, který byl připraven rozpuštěním ve vodě o teplotě 85° C. Jednotlivé směsi byly odlity do formy a sušeny po dobu 7 dní při teplotě 30 ° C, vzniklé 0,5 mm tenké membrány byly analyzovány ATR-FTIR spektroskopií k identifikaci funkčních skupin v kompozitu, dále byla provedena XRD analýza. Zkouška tahem a TGA měření byly realizovány k určení vlivu HA na mechanické vlastnosti, respektive změnu tepelné odolnosti kompozitů ve srovnání s čistým PVA. Byla provedena zkouška bioaktivity v simulovaném krevním roztoku (SBF) po dobu 2h, 7 a 28 dnů. SEM byla použita k charakterizaci povrchové mikrostruktury biocompositních membrán před a po ponoření do SBF. Na povrchu testovaných membrán vznikla vrstva apatitu, která je charakteristická pro bioaktivní materiály. Bylo zjištěno, že s rostoucím množstvím HA částic docházelo ke vzniku aglomerátů v kompozitu, které vznikly mimo jiné jako důsledek růstu krystalů HA během sušení membrán. Bioaktivita rostla s delším působením SBF na vzorky.
7

A stochastic model for sewer base flows using Monte Carlo simulation

Flores, Garth 03 1900 (has links)
Thesis (MSc)--Stellenbosch University, 2015. / ENGLISH ABSTRACT: This thesis deals with understanding and quantifying the components that make up sewage base flows (SBF). SBF is a steady flow that is ubiquitous in sewers, and is clearly seen when measuring the flow rate in the sewer between 03:00 and 04:00. The components of SBF are: ● return flow from residential night use, ● return flow from leaking plumbing, ● groundwater infiltration, ● stormwater inflow. By understanding each component of SBF, this research can answer the burning question as to how much of the SBF was due to plumbing leaks on residential properties. While previous work on SBF had been done, the work focused on groundwater ingress and stormwater inflows, and thus not much had been said about plumbing leaks. Furthermore, previous work focused on SBF as an isolated sewer related topic, whereas this research integrated SBF as both a sewer related topic and water conservation and demand management (WCDM) topic. Due to the high variability in each of the SBF components, a method of quantifying each component was developed using residential end-use modelling and Monte Carlo simulations. The author constructed the Leakage, Infiltration and Inflow Technique Model (LIFT Model). This stochastic model was built in MS Excel using the @Risk software add-on. The LIFT Model uses probability distributions to model the inflow variability. The results of the stochastic model were analysed and the findings discussed. This research can be used by water utilities as a tool to better understand the SBF in networks. Armed with this knowledge, water utilities could make informed decisions about how to best reduce the high SBF encountered in networks. / AFRIKAANSE OPSOMMING: Hierdie verhandeling bespreek die begrip en berekening van die komponente van riool nagvloei. Die nagvloei was duidelik wanneer die vloei in die rioolstelsel tussen 03:00 en 04:00 gemeet is. Die verskillende komponente van die nagvloei is: ● huishoudelike gebruik, ● lekkende krane en toilette, ● grondwaterinfiltrasie, en ● stormwaterinvloei. ’n Begrip van die komponente van nagvloei kan die brandende vraag van hoeveel nagvloei die gevolg van lekkende krane en toilette is, na aanleiding van die navorsing beantwoord. Vorige werk het op beter begrip van die grondwaterinfiltrasie en stormwaterinvloei gefokus en lekke het nie veel aandag geniet nie. Vorige werk het net op nagvloei as geïsoleerde rioolonderwerp gefokus, terwyl hierdie navorsing nagvloei as ’n onderwerp wat met riool verband hou, sowel as ’n waterverbruik- en behoeftebestuursonderwerp, ondersoek. As gevolg van die groot verskil tussen elk van die komponente van die nagvloei, is ’n metode ontwikkel wat elke komponent kwantifiseer deur gebruik te maak van eindgebruik-modelle en Monte Carlo-simulasies. Die outeur het die Leakage Infiltration and Inflow Technique Model (LIFT-Model) gebou. Hierdie stogastiese model is in MS Excel, met behulp van die @Risk sagtewarebyvoeging gebou. Die LIFT-Model gebruik waarskynlikheidverspreidings om invloeivariasie te modelleer. Die resultate van die stogastiese model is ontleed en die bevindinge bespreek. Hierdie navorsing mag moontlik deur watervoorsieningsmaatskapye as instrument gebruik word om nagvloei in rioolstelsels beter te verstaan. Hierdie nuwe kennis kan watervoorsieningsmaatskapye in staat stel om ingeligte besluite te neem rakende die beste metodes om te volg om nagvloei te verminder.
8

Compósito de policaprolactona e carbonato de cálcio (PCLC) : um novo biomaterial para enxerto ósseo

QUEIROZ, Robson Aurélio Silveira de January 2006 (has links)
Made available in DSpace on 2014-06-12T15:50:51Z (GMT). No. of bitstreams: 2 arquivo5257_1.pdf: 9930279 bytes, checksum: 23011bff0745721e6391ddb8c270a9dc (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Compósitos feitos a partir do polímero policaprolactona e de carbonato de cálcio, chamados de PCLC, foram preparados por um processo de carbonatação, que consiste em incidir um fluxo constante de gás carbônico (CO2) em uma solução de metanol e hidróxido de cálcio por 6 horas e depois adicionar ao polímero diluído em diclorometano, após a secagem e evaporação dos solventes o material resultante é prensado no formato de pastilhas. Essas pastilhas foram então expostas, a uma solução simuladora de fluido corporal (SBF) sob temperatura constante de 37 0C, por períodos de 3, 6, 12 e 24 horas e por 7, 14, 21 e 28 dias, o que levou à deposição de estruturas do tipo apatita, semelhantes aos ossos humanos sobre sua superfície. Antes e após ser exposto ao SBF, o compósito PCLC foi analisado por diferentes técnicas de caracterização de materiais, tais como difratometria de raios-X, espectroscopia de infravermelho com transformada de Fourier (FTIR), calorimetria diferencial de varredura (DSC), microscopia eletrônica de varredura (MEV) e espectroscopia dispersiva de raios-X (EDX). Através dessa análise foi possível detectar a formação de apatitas na superfície do PCLC já a partir de 3 horas de exposição ao SBF, sendo a deposição de material inorgânico crescente com o tempo, ocorrendo variação de fases minerais e o aparecimento de hidroxiapatita após 21 dias, o que sugere a indicação do compósito PCLC como um promissor material para o desenvolvimento de implantes biocompatíveis a serem utilizados no corpo humano
9

Avaliação do recobrimento biomimétrico em compósitos de alumina-zircônia texturizadas superficialmente com laser de femtossegundo / Evaluation of biomimetic coating in zirconia-alumina composite textured surface with femtosecond laser

Amanda Abati Aguiar 15 March 2013 (has links)
O principal objetivo deste trabalho foi estudar a influência do tratamento superficial com laser de femtossegundo em amostras de alumina e compósito de alumina-zircônia estabilizada com ítria para depósito e aderência de apatita. Os resultados obtidos mostraram que houve a formação de apatita sobre as superfícies das amostras que foram texturizadas com laser de femtossegundo e em seguida imersa em 1,5 SBF. Este método biomimético pôde, por conseguinte, tornar estas cerâmicas bioativas. Também houve a formação de apatita na superfície das amostras sem o tratamento a laser. Os efeitos da texturização na superfície para as diferentes cerâmicas e a influência do tempo de imersão em 1,5 SBF são discutidos, a fim de determinar a condição ótima para estimular a deposição e a adesão da apatita na superfície dos materiais. Finalmente, os resultados obtidos das diferentes análises são comparados. A adesão da hidroxiapatita é essencial para interação com o substrato e depende das propriedades das superfícies dos materiais. A qualidade desta adesão influenciará sua morfologia e a capacidade futura de osseointegração. As características de superfície dependem da química de superfície, energia de superfície e topografia de superfície. Geralmente, a reatividade de superfície e energia de superfície pode ser influenciada pelas características de molhabilidade, influenciando o desempenho de biomateriais. A adesão e crescimento da apatita depositada também é função da rugosidade superficial. O tratamento superficial com laser de femtossegundo melhora consideravelmente a adesão da apatita obtida pelo recobrimento biomimético nas superfícies dos materiais. / The main objective of this work was to study the influence of femtosecond laser surface treatment on samples of alumina and composite of zirconia-alumina yttria stabilized for deposit and adhesion of apatite. The results showed that there was apatite formation on the surfaces of the samples that have been textured with femtosecond laser and then immersed in SBF 1.5. This biomimetic method can therefore make these bioactive ceramics. There was also the formation of apatite in the samples without laser treatment. The effects of texturing surface for the different ceramics and the influence of immersion time in SBF 1.5 are discussed in order to determine the optimal conditions to promote the deposition and the adhesion of the apatite in the material`s surface. Finally, the results of the different analyzes are compared. The adhesion of hydroxyapatite is essential for interaction with the substrate and depends on the properties of material´s surface. The quality of this adhesion will influence their morphology and the future ability of osseointegration. The surface characteristics depend on the surface chemical, surface energy and surface topography. Generally, the reactivity of surface and the energy of surface can be affected by wetting characteristics influencing the performance of biomaterials. The adhesion and growth of apatite deposited is also a function of surface roughness. The femtosecond laser surface treatment greatly improves the adhesion of apatite obtained by biomimetic coating on the surfaces of materials.
10

Avaliação do recobrimento biomimétrico em compósitos de alumina-zircônia texturizadas superficialmente com laser de femtossegundo / Evaluation of biomimetic coating in zirconia-alumina composite textured surface with femtosecond laser

Aguiar, Amanda Abati 15 March 2013 (has links)
O principal objetivo deste trabalho foi estudar a influência do tratamento superficial com laser de femtossegundo em amostras de alumina e compósito de alumina-zircônia estabilizada com ítria para depósito e aderência de apatita. Os resultados obtidos mostraram que houve a formação de apatita sobre as superfícies das amostras que foram texturizadas com laser de femtossegundo e em seguida imersa em 1,5 SBF. Este método biomimético pôde, por conseguinte, tornar estas cerâmicas bioativas. Também houve a formação de apatita na superfície das amostras sem o tratamento a laser. Os efeitos da texturização na superfície para as diferentes cerâmicas e a influência do tempo de imersão em 1,5 SBF são discutidos, a fim de determinar a condição ótima para estimular a deposição e a adesão da apatita na superfície dos materiais. Finalmente, os resultados obtidos das diferentes análises são comparados. A adesão da hidroxiapatita é essencial para interação com o substrato e depende das propriedades das superfícies dos materiais. A qualidade desta adesão influenciará sua morfologia e a capacidade futura de osseointegração. As características de superfície dependem da química de superfície, energia de superfície e topografia de superfície. Geralmente, a reatividade de superfície e energia de superfície pode ser influenciada pelas características de molhabilidade, influenciando o desempenho de biomateriais. A adesão e crescimento da apatita depositada também é função da rugosidade superficial. O tratamento superficial com laser de femtossegundo melhora consideravelmente a adesão da apatita obtida pelo recobrimento biomimético nas superfícies dos materiais. / The main objective of this work was to study the influence of femtosecond laser surface treatment on samples of alumina and composite of zirconia-alumina yttria stabilized for deposit and adhesion of apatite. The results showed that there was apatite formation on the surfaces of the samples that have been textured with femtosecond laser and then immersed in SBF 1.5. This biomimetic method can therefore make these bioactive ceramics. There was also the formation of apatite in the samples without laser treatment. The effects of texturing surface for the different ceramics and the influence of immersion time in SBF 1.5 are discussed in order to determine the optimal conditions to promote the deposition and the adhesion of the apatite in the material`s surface. Finally, the results of the different analyzes are compared. The adhesion of hydroxyapatite is essential for interaction with the substrate and depends on the properties of material´s surface. The quality of this adhesion will influence their morphology and the future ability of osseointegration. The surface characteristics depend on the surface chemical, surface energy and surface topography. Generally, the reactivity of surface and the energy of surface can be affected by wetting characteristics influencing the performance of biomaterials. The adhesion and growth of apatite deposited is also a function of surface roughness. The femtosecond laser surface treatment greatly improves the adhesion of apatite obtained by biomimetic coating on the surfaces of materials.

Page generated in 0.0128 seconds