• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 186
  • 3
  • 1
  • 1
  • Tagged with
  • 189
  • 189
  • 158
  • 127
  • 109
  • 73
  • 72
  • 44
  • 41
  • 39
  • 36
  • 34
  • 33
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Planejamento da expansão de curto prazo de redes de distribuição considerando geração distribuída e confiabilidade /

Paiva, Rodrigo Rodrigues da Cunha January 2016 (has links)
Orientador: José Roberto Sanches Mantovani / Resumo: O planejamento de sistemas de distribuição consiste em encontrar uma configuração otimizada, a um baixo custo, que permita manter a qualidade e confiabilidade do fornecimento de energia. Fontes de Geração Distribuída (GD) quando inseridas na rede alteram as suas características físicas e operacionais e tornam o problema de planejamento de curto prazo mais complexo para ser resolvido. Portanto, é importante desenvolver ferramentas computacionais eficientes para reduzir custos e o tempo na tomada de decisão para o setor de planejamento das empresas, indicando onde, quando e quais os tipos de componentes devem ser instalados e/ou substituídos nas redes de distribuição na presença de fontes de GD. Neste trabalho propõe-se uma metodologia para o planejamento de curto prazo para alocação das fontes de GD do tipo eólica (considerando as incertezas presentes neste tipo de fonte primária de energia), alocação de bancos de capacitores, dispositivos de proteção e controle, bem como a possibilidade de recondutoramento e troca de estruturas da rede de distribuição, mantendo-se os índices de qualidade para o fornecimento de energia dentro dos padrões estabelecidos pela agência reguladora. O problema de planejamento de curto prazo é formulado como um modelo de programação inteira multiobjetivo, o qual consiste em minimizar os custos de investimento e perdas técnicas na rede (energia não suprida e perdas ôhmicas nos condutores) e está sujeito a restrições físicas, econômicas e operacionais. ... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
22

Métodos e algoritmos para ajuste dos meios básicos para controle de tensão em sistemas de distribuição / Methods and algorithms for voltage control in distribution systems

Milbradt, Rafael Gressler 09 November 2007 (has links)
Nowadays, the quality of energy supplied to customers is an important aspect that must be taken into account in distribution systems analysis. The Brazilian national agency which regulates the distribution systems standards is applying punishments to the energy supplying companies which can not keep the voltage levels inside the allowed limits. Besides, in most cases, energy supplying companies are trying to improve the quality of energy without make use of large investments. The voltage control through the regulation of distribution transformers taps and transformer under load tap changer (ULTC) are being used in most of distribution systems. These types of voltage control may reduce or eliminate the condition which voltage levels exceeding the allowed limits. It is important to observe that use of estimations with few or unfaithful information about secondary networks requires appropriate methodologies. Therefore, this study uses simplified models of secondary networks which may estimate the final results, even in cases without any information. The adjustment of transformers taps is defined to reduce undervoltage in primary and secondary networks. As regards secondary networks, voltage drop are considered up to the center of load, which provides an appropriate voltage levels to the most of customers in analysis. The adjustment of ULTC uses the voltage control law, in order to complement the adjustment earlier described. In this case, the ULTC allows an automaticregulation, which provides a balance of the voltage drop variation during a day. The voltage control law considers voltage drop up to the center of load in secondary networks. Thus the substation voltage control law is calculated by the weighed mean for the power of the voltage drop until the center of load of each distribution transformer. This work also implements an indicator, called energy supplied outside the allowed limits (EFFP). This indicator allows to measure the efficiency of networks, considering voltage levels violations. Thus, it is possible to evaluate the algorithms used in this analysis. As regards the final results, the software called ASD-CT was developed to implement all the algorithms here proposed. This software uses the Java proceedings, according to modern concepts applied on software engineering. Finally, it is important to emphasize that the ASD-CT software presented excellent outputs, considering radially operated distribution networks belong to the State Company of Electric Energy (CEEE-D) / A qualidade da energia fornecida é uma característica cada vez mais desejada. Os órgãos que regulam a distribuição de energia no Brasil aplicam pesadas multas às concessionárias que transgridem os níveis aceitáveis de tensão. Em contrapartida, as concessionárias buscam reduzir os seus custos operacionais, ou seja, melhorar o produto fornecido sem fazer maiores investimentos. A utilização dos meios básicos de controle de tensão, como os tapes dos transformadores de distribuição e comutador de tapes sob carga na Subestação, são meios que já existem na maior parte dos sistemas de distribuição e que, se ajustados corretamente, podem minimizar ou até mesmo sanar o problema das transgressões nos níveis de tensão. Entretanto, realizar a estimação de estado onde as informações sobre as redes secundárias são pouco confiáveis, ou mesmo ausentes requer tratamento e metodologias adequadas. Este trabalho propõe o uso de modelos simplificados de redes de baixa tensão tornando possível a estimação de estado mesmo nos casos de ausência de informações. O ajuste dos tapes dos transformadores de distribuição é realizado de forma a compensar as quedas existentes na rede primária, quedas de tensão do transformador de distribuição e na rede secundária até o centro de carga da mesma. A realização desta regulação de tensão para o centro de carga da rede de baixa tensão proporciona um regime adequado de tensão, senão para todos os consumidores do circuito, pelo menos para a maioria deles. O ajuste do comutador de tapes sob carga da Subestação, através da Lei de Controle de Tensão, funciona de forma complementar ao ajuste anterior, visto que o comutador de tapes sob carga possibilita uma regulação automática, onde se podem compensar as variações na queda de tensão que ocorrem ao longo do dia. A Lei de Controle de Tensão também considera as quedas de tensão até o centro de carga da rede secundária. Desta forma a lei de controle de tensão na subestação é calculada pela média ponderada pela potência das quedas de tensão até o centro de carga de cada transformador da Subestação. O trabalho também propõe e implementa um indicador, nomeado Energia Fornecida Fora do Padrão EFFP, para que seja possível a medição do desempenho das redes quanto às transgressões nos níveis de tensão. Este indicador também serve para medir o desempenho dos algoritmos de ajuste dos meios de controle de tensão utilizados. No que diz respeito aos resultados do trabalho foi desenvolvido um Software, o ASD-CT, que implementa todos os algoritmos aqui propostos. O Software foi desenvolvido totalmente em linguagem Java, utilizando os mais modernos conceitos de Engenharia de Software. O Software ASD-CT obteve ótimos resultados em alimentadores reais da Companhia Estadual de Distribuição de Energia Elétrica (CEEE-D).
23

Planejamento da expansão de curto prazo de redes de distribuição considerando geração distribuída e confiabilidade / The short term planning expansion of distribution networks considering distributed generation and reliability

Paiva, Rodrigo Rodrigues da Cunha [UNESP] 09 December 2016 (has links)
Submitted by RODRIGO RODRIGUES DA CUNHA PAIVA null (rodrigorcp@hotmail.com) on 2017-01-27T17:19:53Z No. of bitstreams: 1 Tese_Rodrigo_Paiva.pdf: 2424828 bytes, checksum: 304f20862a283a2556f7f0f3576eb60e (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-01-31T15:33:23Z (GMT) No. of bitstreams: 1 paiva_rrc_dr_ilha.pdf: 2424828 bytes, checksum: 304f20862a283a2556f7f0f3576eb60e (MD5) / Made available in DSpace on 2017-01-31T15:33:24Z (GMT). No. of bitstreams: 1 paiva_rrc_dr_ilha.pdf: 2424828 bytes, checksum: 304f20862a283a2556f7f0f3576eb60e (MD5) Previous issue date: 2016-12-09 / O planejamento de sistemas de distribuição consiste em encontrar uma configuração otimizada, a um baixo custo, que permita manter a qualidade e confiabilidade do fornecimento de energia. Fontes de Geração Distribuída (GD) quando inseridas na rede alteram as suas características físicas e operacionais e tornam o problema de planejamento de curto prazo mais complexo para ser resolvido. Portanto, é importante desenvolver ferramentas computacionais eficientes para reduzir custos e o tempo na tomada de decisão para o setor de planejamento das empresas, indicando onde, quando e quais os tipos de componentes devem ser instalados e/ou substituídos nas redes de distribuição na presença de fontes de GD. Neste trabalho propõe-se uma metodologia para o planejamento de curto prazo para alocação das fontes de GD do tipo eólica (considerando as incertezas presentes neste tipo de fonte primária de energia), alocação de bancos de capacitores, dispositivos de proteção e controle, bem como a possibilidade de recondutoramento e troca de estruturas da rede de distribuição, mantendo-se os índices de qualidade para o fornecimento de energia dentro dos padrões estabelecidos pela agência reguladora. O problema de planejamento de curto prazo é formulado como um modelo de programação inteira multiobjetivo, o qual consiste em minimizar os custos de investimento e perdas técnicas na rede (energia não suprida e perdas ôhmicas nos condutores) e está sujeito a restrições físicas, econômicas e operacionais. Este problema é resolvido através de um algoritmo genético multiobjetivo baseado no Non-dominated Sorting Genetic Algorithm (NSGA-II), e a metodologia proposta e implementada foi testada em um sistema de distribuição real de 135 barras, e os resultados obtidos mostram eficácia e robustez da metodologia proposta. / The planning of distribution systems consists of finding an optimized configuration, at a low cost, which allows to maintain the quality and reliability of the power supply. Distributed Generation (DG) sources, when inserted into the network, change their physical and operational characteristics and make the short-term planning problem more complex to be solved. Hence, it is important to develop efficient computational tools aiming to reduce costs and the impact of time limits on decision making for the utility planning sector, indicating where, when and what types of components should be installed and / or replaced in distribution networks in the presence of sources. Accordingly, this work proposes a new methodology for the short-term planning which considers the allocation of wind-type DG sources (considering the uncertainties present in this type of primary energy source capacitor banks, protection and control devices, as well as the possibility of reconnecting and exchanging structures of the distribution network, maintaining the quality indices for the supply of energy within the standards established by the regulatory agency. The short-term planning problem is formulated as an integer multiobjective programming model, which consists of minimizing the investment costs and technical losses in the network (energy not supplied and ohmic losses in the conductors) by subjecting to physical, economic and operational constraints. Thus, this problem is solved here by using a multiobjective genetic algorithm based on the Non-dominated Sorting Genetic Algorithm (NSGA-II). In order to testthe proposed methodology, a real distribution system, containing 135-buses, is implemented and analyzed. In short, the obtained results demonstrate its efficacy and robustness in light of the proposed methodology.
24

Modelagem dinâmica e controle do compensador série TCSC para utilização em sistemas de distribuição de energia elétrica / Dynamic modeling and control of the TCSC for applications in electric power distribution systems

Silva, Luciano de Souza da Costa e [UNESP] 23 February 2017 (has links)
Submitted by LUCIANO DE SOUZA DA COSTA E SILVA null (lucianocosta_@hotmail.com) on 2017-04-22T02:39:16Z No. of bitstreams: 1 tese_final_Luciano_corrigido 20-04 final.pdf: 5962866 bytes, checksum: 2f53189a0d49ff5c29d6d23ec699b233 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-04-25T19:28:06Z (GMT) No. of bitstreams: 1 silva_lsc_dr_ilha.pdf: 5962866 bytes, checksum: 2f53189a0d49ff5c29d6d23ec699b233 (MD5) / Made available in DSpace on 2017-04-25T19:28:06Z (GMT). No. of bitstreams: 1 silva_lsc_dr_ilha.pdf: 5962866 bytes, checksum: 2f53189a0d49ff5c29d6d23ec699b233 (MD5) Previous issue date: 2017-02-23 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A tese de doutorado tem como objetivo específico a proposição de um sistema de controle digital aplicado ao compensador série TCSC (Thyristor Controlled Series Compensator), cujo efeito é proporcionar regulação de tensão para cargas dinâmicas presentes no sistema de distribuição de energia elétrica, como no caso de partida de motores elétricos. Os estudos teóricos contemplam a análise detalhada do estágio de potência do TCSC operando em regime permanente. Gráficos generalizados indicam o comportamento harmônico, as possibilidades de ressonância paralela, a característica de reatância fundamental e os esforços de tensão e corrente nos elementos do TCSC ideal, base para a especificação dos componentes do estágio de potência do compensador série. Os resultados para operação em regime permanente do protótipo indicam, nas condições de plena carga, nível máximo de compensação capacitiva de 125% e aumento na regulação de tensão na carga de 7,3% quando comparado às condições da linha sem compensação. A operação em malha fechada do compensador série realizada por controladores digitais do tipo proporcional-integral com saturação anti-windup e realimentações via Integradores Generalizados de Segunda Ordem Multirressonante (IGSOM), garantem robustez, boa dinâmica na resposta transitória e erro nulo em regime permanente para a regulação da reatância fundamental do TCSC. Os ensaios experimentais com partidas diretas de motores demonstram o efeito positivo do compensador série na regulação dinâmica e melhora dos níveis de afundamento momentâneo da tensão na carga. / The specific objective this doctoral thesis consist in the proposition of a digital control system applied to the Thyristor Controlled Series Compensator (TCSC), wich the intended is to provide voltage regulation for dynamics loads present in the electric power distribution system, as in the case of the starting of induction motors. Theoretical studies contemplate the detailed analysis of the TCSC power stage operating under steady-state conditions. Generalized graphs indicate the harmonic behavior, the parallel resonance possibilities, the fundamental reactance characteristic and the stress across the voltage and current in the elements of the ideal TCSC, which are the bases for the design the components of the series compensator power stage. The results for steady-state operation of the prototype indicate under full load conditions a maximum leve of capacitive compensation of 125% and a increase in the load voltage regulation of 7.3% if compared to conditions of the line without compensation. The closed-loop operation of the series compensator, based on proportional-integral digital controllers with anti-windup saturation and feedback by Multiresonant Second-Order Generalized Integrators (MSOGI), presents robustness, good transient response dynamics and null error in steady-state to the regulation of the TCSC fundamental reactance. The experimental tests with motor direct starting demonstrate the positive effect of the series compensator in the dynamic regulation and improvement of the levels of load voltage sags. / FAPESP: 2015/15872-9
25

Estudo de técnicas de previsão de consumo em sistemas de distribuição de gás natural / Study of consumption forecasting systems natural gas distribution

Cruz, Gustavo Lima 20 December 2012 (has links)
The forecasting of gas consumption has a fundamental importance for the natural gas distribution company, since it is common for supply companies include clauses in their contracts that force the distributor companies to perform the volume programming of the natural gas to be withdrawn, these same companies are subjected to the application of penalties if the volume exceeds programmed limits previously established. Thus, in the present work has been studied the potentialities to use of predictive models based on regression, time series and artificial neural networks in forecasting gas consumption, with the intend to improved the methodologies currently used by gas distributor in the daily schedule to send to the supplier, in a scenario characterized by the predominance of industrial consumers with dissimilar characteristics. In this context, considering the potential of forecasting techniques, has been studied the gas consumption forecasting in the medium term of both the industrial consumers and the automotive segments. From these studies it was possible to identify particular types of behaviors, and the forecasting strategy most suitable approach using artificial neural networks, time series or a combination of both. To perform these studies was developed a computational tool to analyzing, parameterize and validate methods of forecasting based on historical data consumption. The results are promising because it presents boundary conditions close to actual values. / A previsão de consumo de gás tem fundamental importância para a companhia distribuidora de gás natural, uma vez que é comum que as empresas supridoras incluam em seus contratos cláusulas que obrigam a concessionária distribuidora realizar a programação do volume de gás natural a ser retirado, sendo a mesma submetida à aplicação de penalidades caso o volume programado exceda limites previamente estabelecidos. Sendo assim, no presente trabalho tem sido estudadas as potencialidades de utilização dos modelos de previsão baseados em regressões, séries temporais e redes neurais artificiais na previsão de consumo de gás, com o objetivo de aprimorar as metodologias atualmente utilizadas pela distribuidora de gás na programação diária realizada junto ao supridor, num cenário caracterizado pela predominância de consumidores industriais com características diferentes entre si. Neste contexto, considerando o potencial das técnicas previsão, foram realizados estudos de previsão de consumo em médio prazo de consumidores dos segmentos industrial e automotivo. A partir destes estudos foi possível identificar tipos de comportamentos particulares, bem como a estratégia de previsão mais adequada, seja utilizando as redes neurais artificiais, séries temporais ou uma combinação de ambas. Para realização dos estudos uma ferramenta computacional foi desenvolvida, a qual oferece as facilidades necessárias para analisar, parametrizar e validar os métodos de previsão baseado em dados históricos de consumo. Os resultados obtidos são promissores, pois apresentam condições de contorno próximo dos valores reais.
26

Otimização da topologia de circuitos de distribuição de energia elétrica usando algoritmos inspirados no comportamento de formigas

Zamboni, Lucca 19 March 2007 (has links)
Made available in DSpace on 2016-03-15T19:37:53Z (GMT). No. of bitstreams: 1 Lucca Zamboni.pdf: 861341 bytes, checksum: 140f5571ef3e3bfdab49cd1cb7cecfff (MD5) Previous issue date: 2007-03-19 / Ant colonies can be considered a multi-agent system, where each agent (ant) works independently by simple rules. Algorithms based on the behavior of ant colonies have been used to solve optimization problems, because in the search for food ants tend to create the shortest (optimum) path between the nest and the food source. In this work, ant inspired algorithms are used in the optimization of the topology of electric energy distribution networks. The algorithm performance is investigated in function of its parameter values. Experiments in hypothetical and actual distribution systems are performed. / Colônias de formigas podem ser consideradas um sistema multi-agente, em que cada agente (formiga) opera independentemente por regras simples. Algoritmos baseados no comportamento de colônias de formigas têm sido usados para resolver problemas de otimização, pois, na procura por alimento, as formigas tendem a estabelecer a rota mais curta (ótima) entre o formigueiro e a fonte de alimento. Neste trabalho, usam-se algoritmos inspirados em formigas na otimização da topologia de circuitos de distribuição de energia elétrica. O desempenho do algoritmo é investigado em função dos valores dos seus parâmetros. Realizam-se experimentos em sistemas de distribuição hipotéticos e realistas.
27

ALOCAÇÃO ÓTIMA DE CAPACITORES EM SISTEMAS DE DISTRIBUIÇÃO RADIAL, UTILIZANDO-SE ESTRATÉGIAS EVOLUTIVAS / EXCELLENT ALLOCATION OF CAPACITORS IN SYSTEMS OF RADIAL DISTRIBUTION, USING EVOLUTION STRATEGIES

Petinelli, Airton Egydio 29 May 2002 (has links)
Made available in DSpace on 2016-08-17T14:52:42Z (GMT). No. of bitstreams: 1 Airton Petinelli.pdf: 783096 bytes, checksum: 283e35e9f4e3e61ee0abe5860d9dcb08 (MD5) Previous issue date: 2002-05-29 / Static reactive power sources, such as shunt capacitors, have been commonly used to provide reactive compensation in distribution systems, minimizing losses and keeping voltage levels within operational limits. Heuristic algorithms for capacitor placement have been proposed in several works. However, the majority of these approaches converge to a local solution. This dissertation presents a hierarchical evolution strategy-based approach for solving the optimal reactive sources placement in radial distribution systems. The approach is based on the (m+l)-EE paradigm, improved by mutations control and by two types of mutations: the classical Gaussian mutation and the Cauchy-based mutation. Discrete standard capacitor values with non-linear cost are considered. Constraints such as the maximum number of parallel banks and installations cost are included. Validation tests have been performed using a real industrial feeder. / Fontes estáticas de potência reativa, tais como os capacitores, têm sido comumente usados para a compensação de potência reativa em sistemas de distribuição de energia elétrica. Capacitores são instalados para minimizar as perdas de potência e manter os níveis de tensão dentro de limites operacionais aceitáveis. Algoritmos heurísticos têm sido propostos na literatura para a alocação de capacitores, entretanto, a maioria deles converge para uma solução local. Nesta dissertação, é apresentado um algoritmo hierárquico utilizando uma estratégia evolutiva para solucionar a alocação ótima de fontes de reativos em sistemas de distribuição radiais. O enfoque é baseado no paradigma (m+l)-EE, melhorado pelo controle de mutação com a utilização de dois tipos: a mutação clássica de Gauss e a mutação de Cauchy. Considera-se também a discretização de banco de capacitores com a utilização de tamanho de células disponíveis comercialmente e respectivos custos de aquisição, assim como restrições do tipo número máximo de capacitores em paralelo e custos de instalação. O algoritmo é testado usando-se um alimentador industrial da Companhia Energética do Maranhão - CEMAR
28

Automatização de processos de detecção de faltas em linhas de distribuição utilizando sistemas especialistas híbridos / Fault detection process automation in distribution lines using hybrid expert systems

Danilo Hernane Spatti 15 June 2011 (has links)
Identificar e localizar faltas em alimentadores de distribuição representa um passo importante para a melhoria da qualidade de energia, pois proporciona impactos diretos sobre o tempo de inspeção. Na verdade, a duração da inspeção implica consideravelmente no intervalo em que os consumidores estão sem energia elétrica, quando ocorre uma interrupção não programada. O objetivo deste trabalho é fornecer um sistema de detecção automática de curtos-circuitos, permitindo aos profissionais das companhias de distribuição acompanhar e monitorar de maneira on-line a ocorrência de possíveis faltas e transitórios eletromagnéticos observados na rede primária de distribuição. A abordagem de detecção utiliza um sistema híbrido que combina ferramentas inteligentes e convencionais para identificar e localizar faltas em redes primárias. Os resultados que foram compilados demonstram grande potencialidade de aplicação da proposta em sistemas de distribuição. / Efficient faults identification and location in power distribution lines constitute an important step for power quality improvement, since they provide direct impacts on the inspection time. In fact, the duration of inspection implies directly in the time interval where consumers are without power, considering here the occurrence of a non-programmed interruption. The objective of this work is to provide an automated fault detection system, allowing to the power companies engineers to online track and monitor the possible occurrence of faults and electromagnetic transients observed in the primary network for the distribution circuits. The detection approach uses a hybrid system, which combines a set of intelligent and conventional tools to identify and locate faults in the primary networks. Validation results show great application potential in distribution systems.
29

Alocação de subestações e alimentadores no planejamento da expansão de sistemas de distribuição via sistema imunológico artificial / Location of substation and feeders for planning of distribution systems by artificial immune system

Silva, Frederico Tassi de Souza 11 March 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-06-17T19:17:57Z No. of bitstreams: 1 fredericotassidesouzasilva.pdf: 1622811 bytes, checksum: 27a2c9213ed77517b8220680d4d24f38 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T14:40:32Z (GMT) No. of bitstreams: 1 fredericotassidesouzasilva.pdf: 1622811 bytes, checksum: 27a2c9213ed77517b8220680d4d24f38 (MD5) / Made available in DSpace on 2016-07-13T14:40:32Z (GMT). No. of bitstreams: 1 fredericotassidesouzasilva.pdf: 1622811 bytes, checksum: 27a2c9213ed77517b8220680d4d24f38 (MD5) Previous issue date: 2016-03-11 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / Este trabalho propõe um método para a resolução de problemas de expansão de sistemas de distribuição, fazendo uma análise multi-objetivo que engloba a alocação de novas subestações, repotencialização das subestações já existentes e dimensionamento de alimentadores, selecionando o caminho dos circuitos para alimentação das cargas e o tipo de condutor utilizado em cada trecho. O problema de otimização apresentado visa minimizar os custos globais do sistema, considerando restrições físicas, técnicas e operacionais. Vários sistemas encontrados na literatura foram utilizados para testar o método e os resultados foram comparados, mostrando que o método pode ser aplicado também para outros sistemas, inclusive de grande porte. A técnica utilizada foi baseada na metaheurística Sistema Imunológico Artificial, que utiliza conceitos básicos de imunologia para a resolução de problemas de otimização combinatória. / This work proposes a method for solving radial distribution systems expansion problems, making a multi-purpose analysis that includes the allocation of new substations, reconditioning of existing substations and sizing feeders selecting the path of the circuits for feeding the fillers and the type of conductor used in each section. The presented optimization problem seeks to minimize overall system costs, involving physical, technical and operational constraints. Many systems found in the literature were used for the test method and the results were compared, showing that the method can also be applied to other systems, including large others. The technique used was based on the metaheuristic Artificial Immune System, which uses basic concepts of immunology for solving combinatorial optimization problems.
30

Alocação ótima de dispositivos de manobra e proteção para planejamento de sistemas de distribuição

Candiá Júnior, Antônio 19 December 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-12T20:36:16Z No. of bitstreams: 1 antoniocandiajunior.pdf: 1972311 bytes, checksum: e81012d951125a50616fee1580b50b3f (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-18T13:17:11Z (GMT) No. of bitstreams: 1 antoniocandiajunior.pdf: 1972311 bytes, checksum: e81012d951125a50616fee1580b50b3f (MD5) / Made available in DSpace on 2017-04-18T13:17:11Z (GMT). No. of bitstreams: 1 antoniocandiajunior.pdf: 1972311 bytes, checksum: e81012d951125a50616fee1580b50b3f (MD5) Previous issue date: 2016-12-19 / O presente trabalho apresenta uma metodologia para o planejamento da expansão de sistemas de distribuição de energia elétrica de média tensão, através da alocação ótima de equipamentos de manobra e de proteção. A proposta se enquadra na fase de planejamento associada à maximização da confiabilidade no fornecimento de energia, com mínimo custo de investimento. A técnica de otimização meta-heurística e bio inspirada denominada sistemasimunológicosartificiaisépropostaparaaplicaçãoafimdetratardemodoeficiente a característica discreta do problema de alocação de equipamentos. Um algoritmo de seleção clonal, que aplica os fundamentos da técnica citada considerando as características deredesdedistribuição, éutilizado. Índicesdeconfiabilidadedadistribuiçãosãoutilizados para avaliar a qualidade de soluções candidatas, juntamente com os respectivos custos de investimento. Portanto, as possíveis soluções são avaliadas mediante a busca de um compromisso adequado entre confiabilidade e custo, ambos critérios considerados nos procedimentos da distribuição de energia elétrica referentes à planejamento da expansão. Restrições como a presença de determinados dispositivos em pontos pré-especificados da rede são observadas e atendidas. Os equipamentos contemplados são chaves seccionadoras e de interconexão, manuais ou automáticas, disjuntores e fusíveis. Estudos de casos com quatro sistemas teste conhecidos da literatura especializada são apresentados. / The present work presents a methodology for the expansion planning of medium voltage electric power distribution systems through the optimal allocation of maneuvering and protectionequipment. Theproposalfitsintotheplanningphaseassociatedwithmaximizing reliability in energy supply, with minimum investment cost. The meta-heuristic and bioinspiredoptimizationtechniquecalledartificialimmunologicalsystemsisproposedinorder to efficiently treatthe discrete characteristicof the equipment allocation problem. A clonal selection algorithm, which make use of the fundamentals of the cited technique considering thecharacteristicsofdistributionnetworks,isused. Distributionreliabilityindicesareused toevaluatethequalityofcandidatesolutions,togetherwiththerespectiveinvestmentcosts. Therefore, the possible solutions are evaluated by searching for an adequate compromise between reliability and cost, both criteria considered in the procedures of the distribution of electric power related to the expansion planning. Restrictions such as the presence of certaindevicesatpre-specifiedpointsinthenetworkareobservedandmet. Theequipments contemplated are disconnecting and interconnecting switches, manual or automatic, circuit breakers, reclosers and fuses. Case studies with four test systems from the specialized literature are presented.

Page generated in 0.0328 seconds