• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A comparative study of the seismic base shear force and story drift ratios using Time History and Modal Spectrum Analysis according to Peru Code E.030 and ASCE 7.16 on high-rise buildings

Quezada Ramos, Eder Nel, Serrano Arone, Yaneth, Huaco, Guillermo 30 September 2020 (has links)
El texto completo de este trabajo no está disponible en el Repositorio Académico UPC por restricciones de la casa editorial donde ha sido publicado. / Since the last decade there is an important increase of high-rise buildings in Peru, especially in urban areas. Therefore, it is necessary to assess if the Peruvian Seismic Code is applicable for this type of buildings which have long natural periods as their main characteristic. The main objective of this article is to compare the results of the base shear and story drift ratios of Peruvian seismic design code E.030 with those of the ASCE 7-16 standard to the case of high-rise buildings, this due to the fact that there is limited information for tall buildings in Peru or comparison between national or international code for this type of structures. These high rise buildings have square and rectangular plan floors. Half of them have moment frames and reinforce concrete slab around the rigid core and the others have post-tensioned slab as their vertical load resisting system and central core walls with peripheral columns as the lateral force resisting system. Hence, the response spectrum analysis (RSA) is carried out for every case of the four tall buildings with different configurations using both seismic codes. Then results are compared with the linear response history analysis (LRHA) considering five Peruvian ground motions records, which were scaled to 0.45g PGA. It was verified that generally both the base shear and the interstory drifts calculated using ASCE7-16 are less than that obtained with the seismic code E.030.
2

Dynamic Amplification Factor Proposal for Seismic Resistant Design of Tall Buildings with Rigid Core Structural System

Quezada, Eder, Serrano, Yaneth, Huaco, Guillermo 01 January 2021 (has links)
El texto completo de este trabajo no está disponible en el Repositorio Académico UPC por restricciones de la casa editorial donde ha sido publicado. / Currently, there is an increase in the demand for tall buildings in the city of Lima. This research proposes to reduce the dynamic amplification factor through the seismic design of tall buildings based on the requirements of Peruvian code considering that they are regular in plan and height. Minimum base shear values according to the comparison of static seismic shear and dynamic shear from the spectral modal analysis were reviewed for cases of buildings larger than 120 m. The study of 28 reinforced concrete buildings was proposed, with different heights - varying from 24 to 36 floors, with different floor configurations, as well as the arrangement of the walls considering as a rigid core structural system. Additionally, the characteristics of the materials, the loads and combinations were defined. The responses of these buildings were determined by the response spectrum analysis (RSA) and then compared with those obtained by the lineal response history analysis (LRHA), for the last analysis, five Peruvian seismic records were used and scaled to 0.45 g. The seismic responses of the LRHA procedure were taken as a benchmark. The result of this study is the analysis and proposal of the C/R factor for high-rise buildings, as well as obtaining the base shear and drift verification. Minimum base shear values can be reduced for high or long-term buildings, being regular in plan and height. / Revisión por pares

Page generated in 0.0557 seconds