• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do protocolo de secagem dos canais radiculares na resistência de união e selamento apical de obturações com cimentos com silicato de cálcio e com hidróxido de cálcio / Influence of drying protocols in the bond strength and apical sealing of teeth filled with calcium silicate and calcium hydroxide sealers

Paula, Adrianne Calixto Freire de 01 October 2014 (has links)
O propósito deste estudo foi avaliar a influência de protocolos de secagem do canal na resistência de união (RU) e no selamento apical (SA) de obturações com AH Plus, Sealapex e MTA Fillapex. Cento e cinquenta e seis raízes de caninos superiores foram submetidas à biomecânica com sistema Reciproc (R50) e distribuídas de acordo com o protocolo de secagem (PS): GI- cones de papel; GII- álcool isopropílico 70% + aspiração com pontas NaviTips; GIII- etanol 95% + cones de papel; GIV- EndoVac + cone de papel. Cada grupo foi dividido em subgrupos conforme o cimento obturador: A- AH Plus; B- Sealapex; C- MTA Fillapex. Utilizou-se para todos os espécimes técnica de obturação do cone único. As raízes de cada subgrupo foram destinadas à avaliação do SA (n=8) e RU (n=5), por meio do método de filtração de fluidos (FF) e push-out (PO), respectivamente. Para o PO as raízes foram seccionadas e um slice de cada terço submetido ao teste e à análise do tipo de falha. Os dados foram submetidos aos testes Anova two-way e three-way e Tukey por meio dos software SPSS 15.0 e SigmaStat 3.5 (&alpha;=5%). Os resultados da FF mostraram diferença significante entre os cimentos MTA e Sealapex (p<0,05). O SA não sofreu influência dos protocolos. Na RU não houve diferença entre os terços do canal (p>0,05), mas houve entre os cimentos (p<0,05), protocolos (p<0,05) e na interação cimentos/protocolos (p<0,05). O AH Plus (1,39±0,60) apresentou os maiores valores de RU em relação ao Sealapex (0,83±0,33) e MTA (0,76±0,34). Espécimes secos com álcool isopropílico proporcionaram aos cimentos testados maior resistência de união que quando secos com etanol (p=0,005) e EndoVac (p=0,002). Canais secos com etanol não influenciaram os cimentos. O uso de cones de papel, EndoVac e álcool isopropílico e obturação com AH Plus apresentaram os maiores valores RU que os demais cimentos. Concluiu-se que a infiltração ocorrida com o AH Plus foi semelhante a dos demais cimentos. O AH Plus apresentou os maiores valores de RU. No terço cervical houve predominância de falhas coesivas e de mistas nos demais terços. / The purpose of this study was to evaluate the influence of drying protocols in the bond strength (BS) and in the apical sealing (AS) of teeth filled with AH Plus, Sealapex and MTA Fillapex. One hundred and fifty-six roots of maxillary canines were subjected to biomechanical preparation with Reciproc (R50) and hand out according to the drying protocol (DP): GI-paper points; GII-70% isopropyl alcohol + aspiration with NaviTip points; GIII-95% ethanol + paper points; GIV-EndoVac + paper points. Each group was divided into subgroups according the used sealer: A- AH Plus; B- Sealapex; C- Fillapex MTA. The single cone obturation technique was used for all the samples. The roots of each subgroup were intended for the evaluation of the AS (n = 8) and the BS (n = 5) by using the fluid filtration (FF) and the push-out (PO) methods, respectively. Regarding the PO, the roots were sectioned and a single slice from each third was subjected to testing and also analysed for the type of failure. Data was submitted to the Tukey, two-way and the three-way variance analysis (ANOVA) resorting the SPSS 15.0 and the SigmaStat 3.5 (&alpha;= 5%) software. The results of the FF revealed a statistical significant difference between the MTA and the Sealapex (p <0.05) sealers. The AS showed no influence of the protocols. When it comes to the BS there was no statistical significant difference between the canal thirds (p> 0.05), but there was between the sealers (p <0.05), the protocols (p <0.05) and in the interaction between the sealers and the protocols (p <0.05). AH Plus (1.39 ± 0.60) revealed the highest BS comparing with Sealapex (0.83 ± 0.33) and MTA (0.76 ± 0.34). The specimens in which the isopropyl alcohol was used, had the highest bond strength results for the sealers, comparing with ethanol (p = 0.005) and EndoVac (p = 0.002). In the canals that ethanol was used, no alteration of the sealer was noticed. The use of paper points, EndoVac and isopropyl alcohol and filling with AH Plus revealed the highest BS values comparing with the other sealers. It was concluded that the infiltration that occurred with AH Plus was similar with the other sealers. AH Plus showed the highest BS. In the cervical third there was preponderance of cohesive failures, and in the other thirds the mixed type of failure.
2

Influência do protocolo de secagem dos canais radiculares na resistência de união e selamento apical de obturações com cimentos com silicato de cálcio e com hidróxido de cálcio / Influence of drying protocols in the bond strength and apical sealing of teeth filled with calcium silicate and calcium hydroxide sealers

Adrianne Calixto Freire de Paula 01 October 2014 (has links)
O propósito deste estudo foi avaliar a influência de protocolos de secagem do canal na resistência de união (RU) e no selamento apical (SA) de obturações com AH Plus, Sealapex e MTA Fillapex. Cento e cinquenta e seis raízes de caninos superiores foram submetidas à biomecânica com sistema Reciproc (R50) e distribuídas de acordo com o protocolo de secagem (PS): GI- cones de papel; GII- álcool isopropílico 70% + aspiração com pontas NaviTips; GIII- etanol 95% + cones de papel; GIV- EndoVac + cone de papel. Cada grupo foi dividido em subgrupos conforme o cimento obturador: A- AH Plus; B- Sealapex; C- MTA Fillapex. Utilizou-se para todos os espécimes técnica de obturação do cone único. As raízes de cada subgrupo foram destinadas à avaliação do SA (n=8) e RU (n=5), por meio do método de filtração de fluidos (FF) e push-out (PO), respectivamente. Para o PO as raízes foram seccionadas e um slice de cada terço submetido ao teste e à análise do tipo de falha. Os dados foram submetidos aos testes Anova two-way e three-way e Tukey por meio dos software SPSS 15.0 e SigmaStat 3.5 (&alpha;=5%). Os resultados da FF mostraram diferença significante entre os cimentos MTA e Sealapex (p<0,05). O SA não sofreu influência dos protocolos. Na RU não houve diferença entre os terços do canal (p>0,05), mas houve entre os cimentos (p<0,05), protocolos (p<0,05) e na interação cimentos/protocolos (p<0,05). O AH Plus (1,39±0,60) apresentou os maiores valores de RU em relação ao Sealapex (0,83±0,33) e MTA (0,76±0,34). Espécimes secos com álcool isopropílico proporcionaram aos cimentos testados maior resistência de união que quando secos com etanol (p=0,005) e EndoVac (p=0,002). Canais secos com etanol não influenciaram os cimentos. O uso de cones de papel, EndoVac e álcool isopropílico e obturação com AH Plus apresentaram os maiores valores RU que os demais cimentos. Concluiu-se que a infiltração ocorrida com o AH Plus foi semelhante a dos demais cimentos. O AH Plus apresentou os maiores valores de RU. No terço cervical houve predominância de falhas coesivas e de mistas nos demais terços. / The purpose of this study was to evaluate the influence of drying protocols in the bond strength (BS) and in the apical sealing (AS) of teeth filled with AH Plus, Sealapex and MTA Fillapex. One hundred and fifty-six roots of maxillary canines were subjected to biomechanical preparation with Reciproc (R50) and hand out according to the drying protocol (DP): GI-paper points; GII-70% isopropyl alcohol + aspiration with NaviTip points; GIII-95% ethanol + paper points; GIV-EndoVac + paper points. Each group was divided into subgroups according the used sealer: A- AH Plus; B- Sealapex; C- Fillapex MTA. The single cone obturation technique was used for all the samples. The roots of each subgroup were intended for the evaluation of the AS (n = 8) and the BS (n = 5) by using the fluid filtration (FF) and the push-out (PO) methods, respectively. Regarding the PO, the roots were sectioned and a single slice from each third was subjected to testing and also analysed for the type of failure. Data was submitted to the Tukey, two-way and the three-way variance analysis (ANOVA) resorting the SPSS 15.0 and the SigmaStat 3.5 (&alpha;= 5%) software. The results of the FF revealed a statistical significant difference between the MTA and the Sealapex (p <0.05) sealers. The AS showed no influence of the protocols. When it comes to the BS there was no statistical significant difference between the canal thirds (p> 0.05), but there was between the sealers (p <0.05), the protocols (p <0.05) and in the interaction between the sealers and the protocols (p <0.05). AH Plus (1.39 ± 0.60) revealed the highest BS comparing with Sealapex (0.83 ± 0.33) and MTA (0.76 ± 0.34). The specimens in which the isopropyl alcohol was used, had the highest bond strength results for the sealers, comparing with ethanol (p = 0.005) and EndoVac (p = 0.002). In the canals that ethanol was used, no alteration of the sealer was noticed. The use of paper points, EndoVac and isopropyl alcohol and filling with AH Plus revealed the highest BS values comparing with the other sealers. It was concluded that the infiltration that occurred with AH Plus was similar with the other sealers. AH Plus showed the highest BS. In the cervical third there was preponderance of cohesive failures, and in the other thirds the mixed type of failure.
3

Análise da qualidade do selamento apical de canais radiculares irradiados com os lasers de Nd:YAG, diodo ou ER:YAG e obturados com os cimentos resinosos AH Plus™, EndoREZ®, Epiphany® ou Epiphany SE® / Quality analysis of the apical seal of root canals irradiated with Nd: YAG, diode or Er: YAG lasers and filled with AH Plus, EndoREZ®, Epiphany® or Epiphany SE® resin based sealers

Moura Netto, Cacio de 11 March 2009 (has links)
O objetivo deste estudo foi analisar a influência da irradiação com lasers de alta intensidade antes da obturação de canais radiculares com cimentos endodônticos resinosos no selamento apical. Raízes permanentes humanas (n=168) foram endodonticamente tratadas e, então, divididas aleatoriamente em quatro grupos experimentais (n=42), de acordo com o tratamento dentinário subsequente. Os grupos foram: GØ (controle) sem tratamento adicional; GN irradiado com o laser de Nd:YAG (1,5 W, 100 mJ, 15 Hz); GD irradiado com o laser de diodo (2,5 W em modo contínuo); GE irradiado com o laser de Er:YAG (1 W, 100 mJ, 10 Hz). Dois espécimes de cada grupo foram preparados para avaliação em microscopia eletrônica de varredura (MEV) convencional para observação morfológica da superfície dentinária apical. Os espécimes remanescentes de cada grupo foram aleatoriamente divididos em quatro subgrupos (n=10), de acordo com o cimento obturador utilizado (AH Plus, EndoREZ®, Epiphany® ou Epiphany SE®). Para a análise de infiltração, os espécimes foram imersos em solução amoniacal de nitrato de prata a 50 % (pH=9,5) por 24 horas. Os valores de infiltração apical, em mm, foram comparados pela ANOVA, seguido pelo teste de Tukey (p<0,05). Cinco secções de cada subgrupo foram aleatoriamente selecionadas e analisadas em MEV em modo ambiental para avaliar a adaptação e penetração do material obturador nas paredes dentinárias. As imagens em MEV ambiental foram classificadas em escores por três avaliadores calibrados. A concordância interexaminadores foi confirmada pelo teste Kappa e os escores foram comparados pelo teste de Kruskal-Wallis (p<0.05). No grupo controle, o cimento EndoREZ® apresentou infiltração de nitrato de prata significantemente menor que todos os outros cimentos (p<0,05), com exceção do Epiphany®. A irradiação com os lasers de Nd:YAG e de diodo diminuiu a infiltração média dos subgrupos obturados com o cimento AH Plus (p<0,05). A irradiação com o laser de Nd:YAG levou a um aumento do nível de infiltração nos subgrupos obturados com EndoREZ® e Epiphany SE®. A adaptação, bem como a penetração dos cimentos, não foram prejudicadas pela prévia irradiação com laser dos canais radiculares, independentemente do laser utilizado. / The aim of this study was to analyze the influence of intracanal high intensity laser irradiation prior to root canal filling with resin based endodontic sealers on the apical sealing. Human dental roots (n=168) were endodontically treated and then randomly divided into four experimental groups (n=42), according to the further dentin surface treatment. The groups were: control (GØ) received no further treatment; GN irradiated with Nd:YAG laser (1.5 W, 100 mJ, 15 Hz); GD irradiated with diode laser (2.5 W in continuous way) and GE irradiated with Er:YAG laser (1 W, 100 mJ, 10 Hz). Two specimens of each group were prepared for conventional scanning electron microscopy (SEM) for morphological observation of the apical dentin surface. The remaining specimens of each group were randomly divided into four subgroups (n=10), according to the sealer used for dental root filling as follows: AH Plus, EndoREZ®, Epiphany® or Epiphany SE®. For leakage analysis, the specimens were immersed into 50 % silver nitrate ammoniacal solution (pH = 9.5) for 24 hours. The values of apical leakage, in mm, were compared by ANOVA followed by Tukeys test (p<0,05). Five sections of each subgroup were randomly selected and analyzed using environmental SEM in order to evaluate the adaptation and penetration of the filling material into the dentin walls. The environmental SEM images were scored by three calibrated examiners. The inter-examiners agreement was confirmed by Kappa test and the scores were compared by Kruskal-Wallis test (p<0.05). At the control group, the EndoREZ® sealer led to significantly smaller silver nitrate leakage in comparison to the others sealers (p<0,05), except by Epiphany®. The irradiation with Nd:YAG and diode lasers reduced the mean leakage of the subgroups filled with AH Plus sealer (p<0,05). Nd:YAG laser irradiation led to a leakage level increase of the subgroups filled with EndoREZ® and Epiphany SE®. The adaptation as well as sealer penetration were not impaired by the root canal prior laser irradiation, independently of the laser used.
4

Análise da qualidade do selamento apical de canais radiculares irradiados com os lasers de Nd:YAG, diodo ou ER:YAG e obturados com os cimentos resinosos AH Plus™, EndoREZ®, Epiphany® ou Epiphany SE® / Quality analysis of the apical seal of root canals irradiated with Nd: YAG, diode or Er: YAG lasers and filled with AH Plus, EndoREZ®, Epiphany® or Epiphany SE® resin based sealers

Cacio de Moura Netto 11 March 2009 (has links)
O objetivo deste estudo foi analisar a influência da irradiação com lasers de alta intensidade antes da obturação de canais radiculares com cimentos endodônticos resinosos no selamento apical. Raízes permanentes humanas (n=168) foram endodonticamente tratadas e, então, divididas aleatoriamente em quatro grupos experimentais (n=42), de acordo com o tratamento dentinário subsequente. Os grupos foram: GØ (controle) sem tratamento adicional; GN irradiado com o laser de Nd:YAG (1,5 W, 100 mJ, 15 Hz); GD irradiado com o laser de diodo (2,5 W em modo contínuo); GE irradiado com o laser de Er:YAG (1 W, 100 mJ, 10 Hz). Dois espécimes de cada grupo foram preparados para avaliação em microscopia eletrônica de varredura (MEV) convencional para observação morfológica da superfície dentinária apical. Os espécimes remanescentes de cada grupo foram aleatoriamente divididos em quatro subgrupos (n=10), de acordo com o cimento obturador utilizado (AH Plus, EndoREZ®, Epiphany® ou Epiphany SE®). Para a análise de infiltração, os espécimes foram imersos em solução amoniacal de nitrato de prata a 50 % (pH=9,5) por 24 horas. Os valores de infiltração apical, em mm, foram comparados pela ANOVA, seguido pelo teste de Tukey (p<0,05). Cinco secções de cada subgrupo foram aleatoriamente selecionadas e analisadas em MEV em modo ambiental para avaliar a adaptação e penetração do material obturador nas paredes dentinárias. As imagens em MEV ambiental foram classificadas em escores por três avaliadores calibrados. A concordância interexaminadores foi confirmada pelo teste Kappa e os escores foram comparados pelo teste de Kruskal-Wallis (p<0.05). No grupo controle, o cimento EndoREZ® apresentou infiltração de nitrato de prata significantemente menor que todos os outros cimentos (p<0,05), com exceção do Epiphany®. A irradiação com os lasers de Nd:YAG e de diodo diminuiu a infiltração média dos subgrupos obturados com o cimento AH Plus (p<0,05). A irradiação com o laser de Nd:YAG levou a um aumento do nível de infiltração nos subgrupos obturados com EndoREZ® e Epiphany SE®. A adaptação, bem como a penetração dos cimentos, não foram prejudicadas pela prévia irradiação com laser dos canais radiculares, independentemente do laser utilizado. / The aim of this study was to analyze the influence of intracanal high intensity laser irradiation prior to root canal filling with resin based endodontic sealers on the apical sealing. Human dental roots (n=168) were endodontically treated and then randomly divided into four experimental groups (n=42), according to the further dentin surface treatment. The groups were: control (GØ) received no further treatment; GN irradiated with Nd:YAG laser (1.5 W, 100 mJ, 15 Hz); GD irradiated with diode laser (2.5 W in continuous way) and GE irradiated with Er:YAG laser (1 W, 100 mJ, 10 Hz). Two specimens of each group were prepared for conventional scanning electron microscopy (SEM) for morphological observation of the apical dentin surface. The remaining specimens of each group were randomly divided into four subgroups (n=10), according to the sealer used for dental root filling as follows: AH Plus, EndoREZ®, Epiphany® or Epiphany SE®. For leakage analysis, the specimens were immersed into 50 % silver nitrate ammoniacal solution (pH = 9.5) for 24 hours. The values of apical leakage, in mm, were compared by ANOVA followed by Tukeys test (p<0,05). Five sections of each subgroup were randomly selected and analyzed using environmental SEM in order to evaluate the adaptation and penetration of the filling material into the dentin walls. The environmental SEM images were scored by three calibrated examiners. The inter-examiners agreement was confirmed by Kappa test and the scores were compared by Kruskal-Wallis test (p<0.05). At the control group, the EndoREZ® sealer led to significantly smaller silver nitrate leakage in comparison to the others sealers (p<0,05), except by Epiphany®. The irradiation with Nd:YAG and diode lasers reduced the mean leakage of the subgroups filled with AH Plus sealer (p<0,05). Nd:YAG laser irradiation led to a leakage level increase of the subgroups filled with EndoREZ® and Epiphany SE®. The adaptation as well as sealer penetration were not impaired by the root canal prior laser irradiation, independently of the laser used.

Page generated in 0.119 seconds