Spelling suggestions: "subject:"shear all"" "subject:"shear fall""
1 |
Midply shear walls use in non-residential buildingsClarke, Colin Nigel 05 1900 (has links)
The MIDPLY shear wall has been developed to be used as a structural system for severe earthquakes. This type of construction has emerged as a viable alternative to concrete and steel for non-residential buildings. The MIDPLY shear wall utilizes a novel arrangement of sheathing and framing members with a special nailing technique. The MIDPLY joints have a different failure mode from that which is observed in standard shear walls. The study reported in this thesis focuses on the response of the MIDPLY shear wall due to monotonic and cyclic tests; the response of an increase size in the cross-section members of the MIDPLY shear wall; and also the evaluation of the design and performance of hold-down connections at the boundary end studs of the MIDPLY shear wall.
Previously tested MIDPLY shear walls showed that the boundary end stud hold-down connection is a very critical component in the performance of the MIDPLY shear wall.
After a simplified analysis of 2 possible hold-down connections (see Fig. 7, 8, 9 and 10), hold-down connection #2 was selected as the most viable option since it had the ability to withstand large lateral forces. For non-residential buildings we expect a larger lateral force when compared to residential buildings. Therefore the cross-section of the members in the MIDPLY shear wall was increased and the number of boundary end studs was modified. These measures resulted in an increase in the lateral force capacity with the use of hold-down connection #2.
The experimental results were used to verify an analytical model representing the MIDPLY shear wall in load-displacement characteristics. Recommendations and future research will also be discussed to show the way for further performance optimization of the wall system.
|
2 |
Quasi-static testing of cantilever masonry shear wall segmentsHernandez, Jaime F. 25 June 2012 (has links)
The primary objective of this thesis was to study how the behavior of flexure-dominated masonry shear-wall segments is affected by changes in the normalized axial load and the percentage of vertical reinforcement. Six reinforced masonry shear-wall segment were constructed and tested at the Ferguson Structural Engineering Laboratory of the University of Texas at Austin. Specimens were 96-in. wide and 96-in. high (aspect ratio equal to 1.0) and were tested with different combinations of axial load ratio (zero and 0.10) and vertical reinforcement ratios (0.33% and 0.16%). Specimens met the 2011 MSJC Code requirements for special reinforced masonry shear walls, and were tested under quasi-static in-plane reversed cyclic loads. The specimens exhibited predominantly flexural behavior, as expected. Specimens exhibited high displacement ductility (5.6 to 16.7), as expected for flexure-dominated specimens. Specimens constructed with "green" units behaved essentially like otherwise identical specimens constructed with conventional ("gray") units. / text
|
3 |
Quasi-static testing of cantilever masonry shear wall segmentsHernandez, Jaime F. 25 June 2012 (has links)
The primary objective of this thesis was to study how the behavior of flexure-dominated masonry shear-wall segments is affected by changes in the normalized axial load and the percentage of vertical reinforcement. Six reinforced masonry shear-wall segment were constructed and tested at the Ferguson Structural Engineering Laboratory of the University of Texas at Austin. Specimens were 96-in. wide and 96-in. high (aspect ratio equal to 1.0) and were tested with different combinations of axial load ratio (zero and 0.10) and vertical reinforcement ratios (0.33% and 0.16%). Specimens met the 2011 MSJC Code requirements for special reinforced masonry shear walls, and were tested under quasi-static in-plane reversed cyclic loads. The specimens exhibited predominantly flexural behavior, as expected. Specimens exhibited high displacement ductility (5.6 to 16.7), as expected for flexure-dominated specimens. Specimens constructed with “green” units behaved essentially like otherwise identical specimens constructed with conventional (“gray”) units. / text
|
4 |
Midply shear walls use in non-residential buildingsClarke, Colin Nigel 05 1900 (has links)
The MIDPLY shear wall has been developed to be used as a structural system for severe earthquakes. This type of construction has emerged as a viable alternative to concrete and steel for non-residential buildings. The MIDPLY shear wall utilizes a novel arrangement of sheathing and framing members with a special nailing technique. The MIDPLY joints have a different failure mode from that which is observed in standard shear walls. The study reported in this thesis focuses on the response of the MIDPLY shear wall due to monotonic and cyclic tests; the response of an increase size in the cross-section members of the MIDPLY shear wall; and also the evaluation of the design and performance of hold-down connections at the boundary end studs of the MIDPLY shear wall.
Previously tested MIDPLY shear walls showed that the boundary end stud hold-down connection is a very critical component in the performance of the MIDPLY shear wall.
After a simplified analysis of 2 possible hold-down connections (see Fig. 7, 8, 9 and 10), hold-down connection #2 was selected as the most viable option since it had the ability to withstand large lateral forces. For non-residential buildings we expect a larger lateral force when compared to residential buildings. Therefore the cross-section of the members in the MIDPLY shear wall was increased and the number of boundary end studs was modified. These measures resulted in an increase in the lateral force capacity with the use of hold-down connection #2.
The experimental results were used to verify an analytical model representing the MIDPLY shear wall in load-displacement characteristics. Recommendations and future research will also be discussed to show the way for further performance optimization of the wall system.
|
5 |
Midply shear walls use in non-residential buildingsClarke, Colin Nigel 05 1900 (has links)
The MIDPLY shear wall has been developed to be used as a structural system for severe earthquakes. This type of construction has emerged as a viable alternative to concrete and steel for non-residential buildings. The MIDPLY shear wall utilizes a novel arrangement of sheathing and framing members with a special nailing technique. The MIDPLY joints have a different failure mode from that which is observed in standard shear walls. The study reported in this thesis focuses on the response of the MIDPLY shear wall due to monotonic and cyclic tests; the response of an increase size in the cross-section members of the MIDPLY shear wall; and also the evaluation of the design and performance of hold-down connections at the boundary end studs of the MIDPLY shear wall.
Previously tested MIDPLY shear walls showed that the boundary end stud hold-down connection is a very critical component in the performance of the MIDPLY shear wall.
After a simplified analysis of 2 possible hold-down connections (see Fig. 7, 8, 9 and 10), hold-down connection #2 was selected as the most viable option since it had the ability to withstand large lateral forces. For non-residential buildings we expect a larger lateral force when compared to residential buildings. Therefore the cross-section of the members in the MIDPLY shear wall was increased and the number of boundary end studs was modified. These measures resulted in an increase in the lateral force capacity with the use of hold-down connection #2.
The experimental results were used to verify an analytical model representing the MIDPLY shear wall in load-displacement characteristics. Recommendations and future research will also be discussed to show the way for further performance optimization of the wall system. / Applied Science, Faculty of / Civil Engineering, Department of / Graduate
|
6 |
Cold-formed Steel Framed Shear Wall Sheathed with Corrugated Sheet SteelYu, Guowang 05 1900 (has links)
Incombustibility is one important advantage of the sheet steel sheathed shear wall over wood panel sheathed shear wall. Compared to shear wall sheathed with plywood and OSB panel, shear wall sheathed with flat sheet steel behaved lower shear strength. Although shear wall sheathed with corrugated sheet steel exhibited high nominal strength and high stiffness, the shear wall usually behaved lower ductility resulting from brittle failure at the connection between the sheathing to frames. This research is aimed at developing modifications on the corrugated sheathing to improve the ductility of the shear wall as well as derive practical response modification factor by establishing correct relationship between ductility factor ? and response modification factor R. Totally 21 monotonic and cyclic full-scale shear wall tests were conducted during the winter break in 2012 by the author in NUCONSTEEL Materials Testing Laboratory in the University of North Texas. The research investigated nineteen 8 ft. × 4 ft. shear walls with 68 mil frames and 27 mil corrugation sheet steel in 11 configurations and two more shear walls sheathed with 6/17-in.OSB and 15/32-in. plywood respectively for comparison. The shear walls, which were in some special cutting arrangement patterns, performed better under lateral load conditions according to the behavior of ductility and shear strength and could be used as lateral system in construction.
|
7 |
Seismic Analysis and Design of Steel Plate Shear WallsBhowmick, Anjan K 11 1900 (has links)
A nonlinear finite element model was developed to study the behaviour of unstiffened steel plate shear walls. The model was validated using the results from quasi-static and dynamic experimental programs. With the validated finite element model, the performance of 4-storey and 8-storey Type D (ductile) and Type LD (limited-ductility) steel plate shear walls with moment-resisting beam-to-column connections was studied under spectrum-compatible seismic records.
A design procedure that aims to achieve optimal seismic behaviour for steel plate shear walls was proposed. The proposed method uses the concepts of indirect capacity design principles of CAN/CSA-S16-01 to identify the infill plates that are likely to yield in the design earthquake. The proposed method was used for the design of two 4-storey and one 8-storey shear walls. Design axial forces and moments in the boundary columns for the shear walls were shown to be in good agreement with nonlinear seismic analysis results. Results also showed that some of the other capacity design methods available generally underestimate the maximum design forces in the columns, while others can be overly conservative. The effect of loading rate on the dynamic behaviour of steel plate shear walls was also investigated, as was the P-Delta effect in terms of its influence on seismic demand in shear and flexure.
A shear strength model of the infill plate with circular openings at any location was developed based on a strip model where all the strips with perforations were partially discounted. A design method for steel plate shear walls with perforations was introduced. The method was applied for the design of boundary columns of a 4-storey steel plate shear wall with perforations. The predicted design forces in the columns for the 4-storey perforated shear wall agreed well with the forces obtained from nonlinear seismic analysis.
Finally, an improved simple formula for estimating the fundamental period of steel plate shear walls was developed by regression analysis of the period data obtained from frequency analysis of series of steel plate shear walls. In addition, the effectiveness of a shearflexure cantilever formulation for determining fundamental periods and P-Delta effects of steel plate shear walls was studied. / Structural Engineering
|
8 |
Seismic Analysis and Design of Steel Plate Shear WallsBhowmick, Anjan K Unknown Date
No description available.
|
9 |
Computation of the Rigidities of Shear Walls with OpeningsRajbhandari, Anila 01 December 2011 (has links)
The main objective of the study is to verify the accuracy of the approximate hand calculation method used extensively by the engineers for the calculation of the rigidity of shear walls with openings. Different types of shear walls are considered varying in the dimensions and positions of the opening, however, maintaining the same basic material properties. The results obtained by the hand calculation are compared to the finite element approach to check for the discrepancy. The finite element analysis software NISA/DISPLAY IV and SAP2000 is considered for the purpose.
|
10 |
Design Method of Cold-Formed Steel Framed Shear Wall Sheathed by Structural Concrete PanelAshkanalam, Aida 12 1900 (has links)
The objective of this research is developing a new method of design for cold-formed steel framed shear wall sheathed by ¾" thick USG structural panel concrete subfloor using a predictive analytical model and comparing the results obtained from the model with those achieved from real testing to verify the analytical model and predicted lateral load-carrying capacity resulted from that. Moreover, investigating the impact of various screw spacings on shear wall design parameter such as ultimate strength, yield strength, elastic stiffness, ductility ratio and amount of energy dissipation is another purpose of this research.
|
Page generated in 0.0554 seconds