• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise teórica e experimental de vigas em alvenaria estrutural submetidas à flexão simples / Theoretical and experimental analysis of structural masonry beams subjected to simple bending

Niero Junior, Adauri 14 February 2014 (has links)
Em projetos de alvenaria estrutural é indispensável à verificação de elementos submetidos à flexão simples, como vigas, vergas, reservatórios e muros de arrimos. Neste trabalho foram analisados oito grupos de vigas, compostos por três exemplares cada um, diferenciando seu comprimento, altura, tipo da unidade (blocos de concreto e blocos cerâmicos) e taxa de armadura. Os traços de graute e argamassa foram mantidos. As vigas e as armaduras longitudinais foram instrumentadas para obtenção dos deslocamentos e deformações. A finalidade do trabalho foi realizar uma comparação dos resultados obtidos através de ensaios experimentais com os dimensionamentos propostos pelas normas ABNT NBR 15812-1:2010 e NBR 15961-1:2011. Foi possível observar que o dimensionamento proposto pelas normas é conservador, pois limita o comportamento à flexão das vigas em cargas baixas quando comparados com experimentais. Já com a retirada dos coeficientes de segurança pode ocorrer, em alguns casos, que a carga teórica prevista seja maior que a dos resultados experimentais. A formulação adaptada da NBR 6118:2007 para obter valores de deslocamentos apresentou uma boa correlação para as vigas de uma fiada. Já para as vigas de duas fiadas observou-se uma pior correlação entre valores teóricos e experimentais, sendo os deslocamentos teóricos menores que os valores medidos experimentalmente. / In structural masonry projects is essential to verify elements subjected to simple bending, such as beams, lintels, water tanks and retaining walls. In this study, an experimental parametric analysis was conducted. Eight groups of beams composed by three specimens were tested and the parameters varied were: length, height, unit type (concrete blocks and ceramic blocks) and reinforcement ratio. The proportion of grout and the mortar were fixed. The beams and longitudinal bars were instrumented to obtain the displacements and strains. The purpose of this study was to compare the results obtained through experimental analysis with the proposed methods presented on ABNT NBR 15812-1:2010 and NBR 15961-1:2011. In the comparison was observed that the proposed design method is conservative, due to the limit load obtained by the code prescriptions was lower than the experimental results. In some cases, the theoretical load results were greater than experimental results when the safety factors were removed. The adapted formulation of the NBR 6118:2007, to obtain displacement values, showed a good correlation to the beams of one row. Regarding to beams with two rows, the correlation between experimental and theoretical values was not suitable, the theoretical displacements presented smaller than the values measured in the tests.
2

Análise teórica e experimental de vigas em alvenaria estrutural submetidas à flexão simples / Theoretical and experimental analysis of structural masonry beams subjected to simple bending

Adauri Niero Junior 14 February 2014 (has links)
Em projetos de alvenaria estrutural é indispensável à verificação de elementos submetidos à flexão simples, como vigas, vergas, reservatórios e muros de arrimos. Neste trabalho foram analisados oito grupos de vigas, compostos por três exemplares cada um, diferenciando seu comprimento, altura, tipo da unidade (blocos de concreto e blocos cerâmicos) e taxa de armadura. Os traços de graute e argamassa foram mantidos. As vigas e as armaduras longitudinais foram instrumentadas para obtenção dos deslocamentos e deformações. A finalidade do trabalho foi realizar uma comparação dos resultados obtidos através de ensaios experimentais com os dimensionamentos propostos pelas normas ABNT NBR 15812-1:2010 e NBR 15961-1:2011. Foi possível observar que o dimensionamento proposto pelas normas é conservador, pois limita o comportamento à flexão das vigas em cargas baixas quando comparados com experimentais. Já com a retirada dos coeficientes de segurança pode ocorrer, em alguns casos, que a carga teórica prevista seja maior que a dos resultados experimentais. A formulação adaptada da NBR 6118:2007 para obter valores de deslocamentos apresentou uma boa correlação para as vigas de uma fiada. Já para as vigas de duas fiadas observou-se uma pior correlação entre valores teóricos e experimentais, sendo os deslocamentos teóricos menores que os valores medidos experimentalmente. / In structural masonry projects is essential to verify elements subjected to simple bending, such as beams, lintels, water tanks and retaining walls. In this study, an experimental parametric analysis was conducted. Eight groups of beams composed by three specimens were tested and the parameters varied were: length, height, unit type (concrete blocks and ceramic blocks) and reinforcement ratio. The proportion of grout and the mortar were fixed. The beams and longitudinal bars were instrumented to obtain the displacements and strains. The purpose of this study was to compare the results obtained through experimental analysis with the proposed methods presented on ABNT NBR 15812-1:2010 and NBR 15961-1:2011. In the comparison was observed that the proposed design method is conservative, due to the limit load obtained by the code prescriptions was lower than the experimental results. In some cases, the theoretical load results were greater than experimental results when the safety factors were removed. The adapted formulation of the NBR 6118:2007, to obtain displacement values, showed a good correlation to the beams of one row. Regarding to beams with two rows, the correlation between experimental and theoretical values was not suitable, the theoretical displacements presented smaller than the values measured in the tests.
3

Ligações em estruturas de aço utilizando emendas com parafusos de alta resistência solicitadas na flexão simples / Connections in steel structures using emendations with high strength screws requested in simple bending

Pereira, Ronivon Soares 24 June 2014 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-01-29T17:20:07Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Ronivon Soares Pereira - 2014.pdf: 2996792 bytes, checksum: f4e736b7c557dc7ccddb4806f63bfbaa (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-01-29T17:43:00Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Ronivon Soares Pereira - 2014.pdf: 2996792 bytes, checksum: f4e736b7c557dc7ccddb4806f63bfbaa (MD5) / Made available in DSpace on 2015-01-29T17:43:00Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Ronivon Soares Pereira - 2014.pdf: 2996792 bytes, checksum: f4e736b7c557dc7ccddb4806f63bfbaa (MD5) Previous issue date: 2014-06-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Structure is designed to have satisfactory performance given the quality standards and requirements in the construction of which designers need. Increasingly, large metal structures are developing in this competitive market, where performance and quality of the project depend on manufacturing processes of materials, assembly, inspection and maintenance. The metal structures, especially those of type I profiles of parallel laminated tabs depend on the quality control in your bolted splices. This study aimed to analyze the bearing capacity of steel beams supported by profiles consist of type I rolled parallel flanges with two axes of symmetry, being endowed with seams with high strength bolts type ASTM A325, diameter 19 mm. Eight beams with a length of 3000 mm, two reference beams were tested. In the remaining six beams splices were made at different positions varying the amount of seams. All models have been efforts required by simple bending to failure, by analyzing the vertical displacement, torsional displacement relative and specific deformations of steel. The connections of the beams withstood the test flexural not being observed and no break on the bolts or the connecting plate, featuring breaking loads between 74% and 85% for beams of series with connections. Considerably beams with connections showed no breaking loads far below the reference beams with breaking loads between 78% and 100%. The results indicate that the beams with bolted with high strength bolts connections are sturdy and therefore can be used by designers in the field of steel structure as another option. / Uma estrutura é concebida para ter desempenho satisfatório atendendo aos padrões de qualidade na construção e requisitos dos quais os projetistas necessitam. Cada vez mais as estruturas metálicas de grande porte vêm se desenvolvendo nesse mercado competitivo, onde o desempenho e a qualidade do projeto dependem dos processos de fabricação dos materiais utilizados, da montagem, da inspeção e manutenção. As estruturas metálicas, principalmente as de perfis tipo I laminados de abas paralelas dependem do controle de qualidade em suas emendas parafusadas. Este estudo teve por objetivo analisar a capacidade resistente de vigas bi apoiadas em aço constituídas de perfis tipo I laminados de abas paralelas com dois eixos de simetria, sendo dotadas de emendas com parafusos de alta resistência do tipo ASTM A325 de diâmetro 19 mm. Foram ensaiados oito vigas com comprimento de 3000 mm, sendo duas vigas de referência. Nas seis vigas restantes foram confeccionadas emendas em diferentes posições variando a quantidade de emendas. Todos os modelos estiveram solicitados por esforços de flexão simples até à ruptura, analisando os deslocamentos verticais, deslocamentos relativos à torção e as deformações específicas do aço. As ligações das vigas resistiram ao ensaio à flexão, não sendo constatada nenhuma ruptura nos parafusos e nem na chapa de ligação, apresentando cargas de ruptura entre 74% e 85% para as vigas da série com ligações. Consideravelmente as vigas com ligações não apresentaram cargas de ruptura muito inferiores às vigas de referência, com cargas de ruptura entre 78% e 100%. Os resultados indicam que as vigas com ligações parafusadas com parafusos de alta resistência são resistentes e por isso podem ser utilizadas por projetistas da área de estrutura metálica como mais uma opção.
4

Efeitos da energia de soldagem e consumíveis sobre a resistência à flexão de juntas "T" soldadas em perfis tubulares

Dalcin, Rafael Luciano January 2016 (has links)
O uso de aços de alta resistência mecânica vem crescendo significativamente, principalmente em situações onde é necessário um material com grande limite elástico para a conformação a frio e boa soldabilidade. Nessas aplicações, a elevada resistência reduz o peso e/ou aumenta a carga que pode ser suportada pelas estruturas produzidas. A introdução dos aços fabricados por processamento termomecânico controlado (TMCP) demandou maiores propriedades mecânicas e metalúrgicas das juntas soldadas sobre eles produzidas. Em função desses fatores, a energia de soldagem é estritamente limitada, e para evitar uma eventual redução da resistência mecânica da zona afetada pelo calor (ZAC), é necessário testar os procedimentos de soldagem próximos daqueles que serão usados na estrutura real. O objetivo deste estudo é obter dados detalhados referentes à eficiência mecânica de juntas soldadas por MAG e com diferentes energias, sobre perfis tubulares quadrados em aço TMCP, formando um conjunto soldado coluna/viga. Seis energias de soldagem e dois metais de adição foram utilizados (AWS ER80S-G e AWS ER120S-G), o primeiro somente com as soldas posicionadas em todo o contorno do perfil, e o segundo com soldas em todo o contorno, transversais e longitudinais em relação à direção de aplicação da carga. Vinte e quatro estruturas foram soldadas, instrumentadas e submetidas à flexão. Comparando as juntas soldadas com mesma energia, observou-se maior resistência à flexão nas soldas longitudinais e em todo contorno, e valores inferiores para soldas transversais. Além disso, pôde ser constatado que 1,2 kJ/mm de energia de soldagem deu os melhores resultados para as juntas soldadas com ambos os consumíveis, uma vez que até esse valor a área da seção resistente das juntas soldadas aumentou significativamente. O uso de energias mais elevadas não foi eficaz para aumentar a resistência à flexão das juntas soldadas ora investigadas, pois o efeito da energia de soldagem sobre a redução da dureza e, consequentemente, resistência mecânica da ZAC, aparentemente se sobrepõe ao aumento da área da seção resistente da junta soldada. / The use of high strength steels is growing significantly, especially in situations where it is necessary a material with high strength for cold forming and good weldability. In these applications, the high strength decreases the weight and/or increases the load that can be supported by the structures produced. The introduction of steels made by thermomechanical controlled processing (TMCP) demanded higher mechanical and metallurgical properties of the welded joints produced on them. Given these factors, the heat input is strictly limited, and to avoid any reduction in the mechanical strength of the heat affected zone (HAZ), it is required to test welding procedures close to those that will be used in the actual structure. The aim of this study is to obtain detailed data on the mechanical efficiency of welded joints with GMAW and different heat inputs, on square tubular profiles in TMCP steel, disposed as a column/beam weldment. Six different heat inputs and two filler metals were used (AWS ER80S-G and AWS ER120S-G), the first one with the welds located around the profile contour, and the second one with welds all around the profile, transverse and longitudinal to the axis of the weld bead. Twenty-four welded structures were instrumented and subjected to bending. Comparing the welded joints with the same heat input, it can be noticed that higher bending strength is obtained from all-around contour and longitudinal welds, and lower values for the transverse welds. Moreover, it could be seen of 1.2 kJ/mm heat input gave optimum results to the welded joints with both consumables, since up to this value the area of the resistant section of welded joints increased significantly. The use of higher heat inputs was not effective to increase the bending strength of the welded joints herein investigated, since the effect of heat input on the reduction of the hardness and, consequently, mechanical strength of the HAZ, apparently overrides the increase in the area of the resistant section of the welded joint.
5

Efeitos da energia de soldagem e consumíveis sobre a resistência à flexão de juntas "T" soldadas em perfis tubulares

Dalcin, Rafael Luciano January 2016 (has links)
O uso de aços de alta resistência mecânica vem crescendo significativamente, principalmente em situações onde é necessário um material com grande limite elástico para a conformação a frio e boa soldabilidade. Nessas aplicações, a elevada resistência reduz o peso e/ou aumenta a carga que pode ser suportada pelas estruturas produzidas. A introdução dos aços fabricados por processamento termomecânico controlado (TMCP) demandou maiores propriedades mecânicas e metalúrgicas das juntas soldadas sobre eles produzidas. Em função desses fatores, a energia de soldagem é estritamente limitada, e para evitar uma eventual redução da resistência mecânica da zona afetada pelo calor (ZAC), é necessário testar os procedimentos de soldagem próximos daqueles que serão usados na estrutura real. O objetivo deste estudo é obter dados detalhados referentes à eficiência mecânica de juntas soldadas por MAG e com diferentes energias, sobre perfis tubulares quadrados em aço TMCP, formando um conjunto soldado coluna/viga. Seis energias de soldagem e dois metais de adição foram utilizados (AWS ER80S-G e AWS ER120S-G), o primeiro somente com as soldas posicionadas em todo o contorno do perfil, e o segundo com soldas em todo o contorno, transversais e longitudinais em relação à direção de aplicação da carga. Vinte e quatro estruturas foram soldadas, instrumentadas e submetidas à flexão. Comparando as juntas soldadas com mesma energia, observou-se maior resistência à flexão nas soldas longitudinais e em todo contorno, e valores inferiores para soldas transversais. Além disso, pôde ser constatado que 1,2 kJ/mm de energia de soldagem deu os melhores resultados para as juntas soldadas com ambos os consumíveis, uma vez que até esse valor a área da seção resistente das juntas soldadas aumentou significativamente. O uso de energias mais elevadas não foi eficaz para aumentar a resistência à flexão das juntas soldadas ora investigadas, pois o efeito da energia de soldagem sobre a redução da dureza e, consequentemente, resistência mecânica da ZAC, aparentemente se sobrepõe ao aumento da área da seção resistente da junta soldada. / The use of high strength steels is growing significantly, especially in situations where it is necessary a material with high strength for cold forming and good weldability. In these applications, the high strength decreases the weight and/or increases the load that can be supported by the structures produced. The introduction of steels made by thermomechanical controlled processing (TMCP) demanded higher mechanical and metallurgical properties of the welded joints produced on them. Given these factors, the heat input is strictly limited, and to avoid any reduction in the mechanical strength of the heat affected zone (HAZ), it is required to test welding procedures close to those that will be used in the actual structure. The aim of this study is to obtain detailed data on the mechanical efficiency of welded joints with GMAW and different heat inputs, on square tubular profiles in TMCP steel, disposed as a column/beam weldment. Six different heat inputs and two filler metals were used (AWS ER80S-G and AWS ER120S-G), the first one with the welds located around the profile contour, and the second one with welds all around the profile, transverse and longitudinal to the axis of the weld bead. Twenty-four welded structures were instrumented and subjected to bending. Comparing the welded joints with the same heat input, it can be noticed that higher bending strength is obtained from all-around contour and longitudinal welds, and lower values for the transverse welds. Moreover, it could be seen of 1.2 kJ/mm heat input gave optimum results to the welded joints with both consumables, since up to this value the area of the resistant section of welded joints increased significantly. The use of higher heat inputs was not effective to increase the bending strength of the welded joints herein investigated, since the effect of heat input on the reduction of the hardness and, consequently, mechanical strength of the HAZ, apparently overrides the increase in the area of the resistant section of the welded joint.
6

Efeitos da energia de soldagem e consumíveis sobre a resistência à flexão de juntas "T" soldadas em perfis tubulares

Dalcin, Rafael Luciano January 2016 (has links)
O uso de aços de alta resistência mecânica vem crescendo significativamente, principalmente em situações onde é necessário um material com grande limite elástico para a conformação a frio e boa soldabilidade. Nessas aplicações, a elevada resistência reduz o peso e/ou aumenta a carga que pode ser suportada pelas estruturas produzidas. A introdução dos aços fabricados por processamento termomecânico controlado (TMCP) demandou maiores propriedades mecânicas e metalúrgicas das juntas soldadas sobre eles produzidas. Em função desses fatores, a energia de soldagem é estritamente limitada, e para evitar uma eventual redução da resistência mecânica da zona afetada pelo calor (ZAC), é necessário testar os procedimentos de soldagem próximos daqueles que serão usados na estrutura real. O objetivo deste estudo é obter dados detalhados referentes à eficiência mecânica de juntas soldadas por MAG e com diferentes energias, sobre perfis tubulares quadrados em aço TMCP, formando um conjunto soldado coluna/viga. Seis energias de soldagem e dois metais de adição foram utilizados (AWS ER80S-G e AWS ER120S-G), o primeiro somente com as soldas posicionadas em todo o contorno do perfil, e o segundo com soldas em todo o contorno, transversais e longitudinais em relação à direção de aplicação da carga. Vinte e quatro estruturas foram soldadas, instrumentadas e submetidas à flexão. Comparando as juntas soldadas com mesma energia, observou-se maior resistência à flexão nas soldas longitudinais e em todo contorno, e valores inferiores para soldas transversais. Além disso, pôde ser constatado que 1,2 kJ/mm de energia de soldagem deu os melhores resultados para as juntas soldadas com ambos os consumíveis, uma vez que até esse valor a área da seção resistente das juntas soldadas aumentou significativamente. O uso de energias mais elevadas não foi eficaz para aumentar a resistência à flexão das juntas soldadas ora investigadas, pois o efeito da energia de soldagem sobre a redução da dureza e, consequentemente, resistência mecânica da ZAC, aparentemente se sobrepõe ao aumento da área da seção resistente da junta soldada. / The use of high strength steels is growing significantly, especially in situations where it is necessary a material with high strength for cold forming and good weldability. In these applications, the high strength decreases the weight and/or increases the load that can be supported by the structures produced. The introduction of steels made by thermomechanical controlled processing (TMCP) demanded higher mechanical and metallurgical properties of the welded joints produced on them. Given these factors, the heat input is strictly limited, and to avoid any reduction in the mechanical strength of the heat affected zone (HAZ), it is required to test welding procedures close to those that will be used in the actual structure. The aim of this study is to obtain detailed data on the mechanical efficiency of welded joints with GMAW and different heat inputs, on square tubular profiles in TMCP steel, disposed as a column/beam weldment. Six different heat inputs and two filler metals were used (AWS ER80S-G and AWS ER120S-G), the first one with the welds located around the profile contour, and the second one with welds all around the profile, transverse and longitudinal to the axis of the weld bead. Twenty-four welded structures were instrumented and subjected to bending. Comparing the welded joints with the same heat input, it can be noticed that higher bending strength is obtained from all-around contour and longitudinal welds, and lower values for the transverse welds. Moreover, it could be seen of 1.2 kJ/mm heat input gave optimum results to the welded joints with both consumables, since up to this value the area of the resistant section of welded joints increased significantly. The use of higher heat inputs was not effective to increase the bending strength of the welded joints herein investigated, since the effect of heat input on the reduction of the hardness and, consequently, mechanical strength of the HAZ, apparently overrides the increase in the area of the resistant section of the welded joint.
7

Análise experimental da resistência à flexão simples de vigas de aço tipo "I" compostas de perfis laminados dotadas de emendas soldadas / Experimental analysis of flexural simple steel beams type "I" com-folded profiles equipped rolled welded amendments

Borges, Rone Sergio Freitas 04 February 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2015-12-07T17:47:17Z No. of bitstreams: 2 Dissertação - Rone Sérgio Freitas Borges - 2015.pdf: 6213430 bytes, checksum: 42046e4b45c71b2cd44ac6a2ea27e1bc (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-12-08T06:33:05Z (GMT) No. of bitstreams: 2 Dissertação - Rone Sérgio Freitas Borges - 2015.pdf: 6213430 bytes, checksum: 42046e4b45c71b2cd44ac6a2ea27e1bc (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-12-08T06:33:05Z (GMT). No. of bitstreams: 2 Dissertação - Rone Sérgio Freitas Borges - 2015.pdf: 6213430 bytes, checksum: 42046e4b45c71b2cd44ac6a2ea27e1bc (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-02-04 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In Brazil, despite the skilled labor shortage, the use of metal structures in buildings has increased considerably due to factors such as speed of execution, cleaning the construction site, low deadweight compared with reinforced concrete structures, low material waste, etc. For better utilization of equipment and for which continuity of the openings is necessary to use the amendments, which can be welded or screwed. The quality of the amendments must meet the standards required by the design standards, in rolled profiles, according to ABNT NBR 8800:2008 (Steel Structures Design and Composite Structures of Steel and concrete buildings). These profiles have great applicability in large structures and their use is growing in buildings with these characteristics. This paper presents the experimental study of bearing capacity of two beams supported by steel made of rolled profiles section I of type W 250 x 22,3 ASTM A-572, grade 50, rolled parallel flaps with two axes of symmetry, being provided splices using full penetration welds MIG type (Metal Inert Gas). Seven beams were tested with a length of 3000 mm, with a reference beam. In the remaining six beams amendments were made in different positions varying the amount of amendments. This study also provides a comparison between the results obtained in this work and those obtained by Pereira (2014), which used beams with bolted connections using the same provisions of the amendments of this work, but with ASTM A-325 and screw diameter of 19 mm. All models have been requested by simple bending stress at break, according to the analysis of vertical displacement, and torsional displacement relative specific deformations steel. The connections of beams resisted the simple bending tests not being observed no break in welds. The main contribution of this work was to show that, if well executed, welded connections and bolted performed by Pereira (2014), with the specifications described in this paper, can be used as elements of connections in steel beams subjected to bending, as well resisted the requested efforts . / No Brasil, apesar da escassez de mão de obra qualificada, a utilização de estruturas metálicas nas edificações vem aumentando consideravelmente devido a alguns fatores como rapidez de execução, limpeza do canteiro de obras, baixo peso próprio se comparado com as estruturas de concreto armado, baixo desperdício de material etc.. Para o melhor aproveitamento de material e para que se continuidade dos vãos é necessário a utilização das emendas, que podem ser soldadas ou parafusadas. A qualidade das emendas deve atender aos padrões exigidos pelas normas de projeto, no caso dos perfis laminados, segundo a ABNT NBR 8800:2008 (Projeto de Estruturas de Aço e de Estruturas Mistas de Aço e Concreto de Edifícios). Esses perfis tem grande aplicabilidade em estruturas de grande porte e seu uso é crescente em edificações com essas características. Este trabalho apresenta o estudo experimental da capacidade resistente de vigas bi-apoiadas em aço constituídas de perfis laminados de seção I do tipo W 250 x 22,3 ASTM A-572, grau 50, laminados de abas paralelas com dois eixos de simetria, sendo dotadas de emendas com soldas de penetração total do tipo MIG (Metal Inert Gas). Foram ensaiadas sete vigas com comprimento de 3000 mm, sendo uma viga de referência. Nas seis vigas restantes foram confeccionadas emendas em diferentes posições variando a quantidade de emendas. O presente estudo traz também uma comparação entre os resultados obtidos neste trabalho e os obtidos por Pereira (2014), no qual utilizou vigas com ligações parafusadas utilizando as mesmas disposições das emendas deste trabalho, mas com parafusos ASTM A-325 e diâmetro de 19 mm. Todos os modelos estiveram solicitados por esforços de flexão simples até à ruptura, de acordo com a análise dos deslocamentos verticais, deslocamentos relativos à torção e as deformações específicas do aço. As ligações das vigas resistiram aos ensaios de flexão simples, não sendo constatada nenhuma ruptura nas soldas. A principal contribuição deste trabalho foi mostrar que, se bem executadas, as ligações soldadas e as parafusadas realizadas por Pereira (2014), com as especificações descritas neste trabalho, podem ser utilizadas como elementos de ligações em vigas metálicas submetidas à flexão, pois resistiram bem aos esforços solicitados.

Page generated in 0.0758 seconds