• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Convective Heat Transfer in Parallel Plate Heat Sinks

Holzaepfel, Gregory M. 25 April 2011 (has links)
No description available.
2

Investigation of Copper Foam Coldplates as a High Heat Flux Electronics Cooling Solution

Wilson, Scott E. 28 April 2005 (has links)
Compact heat exchangers such as porous foam coldplates have great potential as a high heat flux cooling solution for electronics due to their large surface area to volume ratio and tortuous coolant path. The focus of this work was the development of unit cell modeling techniques for predicting the performance of coldplates with porous foam in the coolant path. Multiple computational fluid dynamics (CFD) models which predict porous foam coldplate pressure drop and heat transfer performance were constructed and compared to gain insight into how to best translate the foam microstructure into unit cell model geometry. Unit cell modeling in this study was realized by applying periodic boundary conditions to the coolant entrance and exit faces of a representative unit cell. A parametric study was also undertaken which evaluated dissimilar geometry translation recommendations from the literature. The use of an effective thermal conductivity for a representative orthogonal lattice of rectangular ligaments was compared to a porosity-matching technique of a similar lattice. Model accuracy was evaluated using experimental test data collected from a porous copper foam coldplate using deionized water as coolant. The compact heat exchanger testing facility which was designed and constructed for this investigation was shown to be capable of performing tests with coolant flow rates up to 300 mL/min and heat fluxes up to 290 W/cm2. The greatest technical challenge of the testing facility design proved to be the method of applying the heat flux across a 1 cm2 contact area. Based on the computational modeling results and experimental test data, porous foam modeling recommendations and porous foam coldplate design suggestions were generated.

Page generated in 0.1137 seconds