Eficiência energética no controle inteligente de sistemas de bombeamento

Filipe Alves Cordeiro, Luiz 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T17:37:53Z (GMT). No. of bitstreams: 2 arquivo5364_1.pdf: 2194921 bytes, checksum: 693a6055584ba787f0bf30e3f1f3bb15 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Com a globalização e a competitividade em todos os níveis do setor industrial, a conservação de energia se tornou um fator importante na indústria moderna. O consumo de energia elétrica do setor industrial representa 47% do consumo total do país. A força motriz representa a maior parte deste consumo, chegando a ser superior a 80% nos setores têxtil, de papel e celulose. Este trabalho descreve a aplicação da modelagem, controle e inteligência artificial para melhorar a eficiência energética em sistemas industriais. O trabalho apresenta um sistema de controle baseado em inteligência artificial aplicado a sistemas de bombeamento com objetivo de aumentar a eficiência energética. Neste trabalho são apresentadas as condições de contorno de aplicação de redes neurais em algoritmos de controle com objetivo de reduzir o consumo de energia elétrica. A implementação aplicada em sistemas de bombeamento é apresentada com os dados experimentais obtidos no Laboratório de Sistemas Motrizes da Universidade Federal de Pernambuco. Comparações quanto ao consumo de energia são realizadas usando as estratégias de controle convencionais e a proposta neste trabalho
2

Sistemas de bombeamento de água com velocidade de rotação variável

Kuritza, Jóice Cristini January 2017 (has links)
O consumo de energia dispendido pelos sistemas de bombeamento apresenta valores elevados e que podem onerar a operação dos sistemas de abastecimento de água realizada pelas companhias de saneamento. Assim, esta pesquisa está centrada no desenvolvimento de uma metodologia para análise da eficiência energética desses sistemas. O procedimento metodológico foi desenvolvido para uma tipologia genérica de sistema composta de dois reservatórios, inferior e superior, um conjunto motobomba e uma adutora, responsável pelo transporte de água entre eles. Foram avaliadas 96 possibilidades geométricas para esse sistema, formadas a partir da combinação de diferentes alturas geométricas, comprimentos e diâmetros da linha adutora. Ainda, foram estudados três formatos de curva, com quatro volumes de consumo diário distintos, em duas situações, início e fim de projeto. O algoritmo Shuffled Complex Evolution – SCE-UA foi empregado para obter a regra de operação otimizada do sistema de bombeamento e a função-objetivo foi formulada para representar os custos de energia para 20 anos de operação somado aos custos de instalação do sistema de bombeamento (adutora, reservatório superior e conjunto motobomba). Além disso, foram calculados índices e indicadores para facilitar o entendimento e a avaliação da eficiência energética de sistemas de bombeamento. A partir da análise dos resultados dos sistemas cuja operação foi otimizada, e dos resultados dos índices e indicadores, foram estabelecidos critérios e equações que podem ser utilizados para análise da operação, dimensionamento e eficiência energética de sistemas de bombeamento de água. Também, foi desenvolvida uma metodologia para a estimativa da energia mínima que um sistema de bombeamento pode consumir se todos os critérios de eficiência energética forem satisfeitos, ou seja, quando todas as grandezas que compõem o cálculo da energia forem determinadas a partir de critérios otimizados. Essa metodologia foi aplicada em dois cenários: projetos de sistemas de bombeamento de água e diagnóstico de sistemas de bombeamento de água existentes. Na primeira abordagem, o indicador se mostrou útil para inferir sobre consumo de energia e, inclusive, definir o diâmetro ótimo da linha adutora com maior ponderação. Já na segunda abordagem, o indicador tem potencial para ser utilizado na definição da linha de base do sistema e pode auxiliar a tomada de decisão e gestão hidroenergética desses sistemas. / The energy consumed by the pumping systems has high values and can overload the operation of the water supply systems carried out by the sanitation companies. Thus, this research is focused on the development of a methodology to analyze the energy efficiency of these systems. The methodological procedure was developed for a generic system composed of two reservoirs, upper and lower, pumping system and a pipeline, responsible for transporting water between the reservoirs. It was evaluated 96 geometric possibilities for this system, formed from the combination of different static heights, lengths and diameters of the pipeline. Also, three curve formats were studied, with four distinct daily consumption volumes, in two situations, beginning and end of the project. The Shuffled Complex Evolution (SCE-UA) algorithm was employed to obtain the optimal operating rule for the pumping system and the objective function was formulated to represent the energy costs for 20 years of operation plus the pumping system installation costs (pipeline, upper reservoir and pumping system). In addition, indexes and indicators were calculated to facilitate the understanding and evaluation of the energy efficiency of pumping systems. Based on the analysis of the results of the systems whose operation was optimized, and the results of indexes and indicators, criteria and equations were established that can be used to analyze the operation, design and energy efficiency of water pumping systems. Also, a methodology was developed to estimate the minimum energy that a pumping system can consume if all the energy efficiency criteria are met, that is, when all the quantities that compose the energy calculation are determined from optimized criteria. This methodology was applied in two scenarios: projects of water pumping systems and diagnosis of existing water pumping systems. In the first approach, the indicator was useful to infer about energy consumption and, even, to define the optimum diameter of the most heavily weighted pipeline. In the second approach, the indicator has the potential to be used in the definition of the baseline of the system and may help decision making and hydropower management of these systems.
3

Sistemas de bombeamento de água com velocidade de rotação variável

Kuritza, Jóice Cristini January 2017 (has links)
O consumo de energia dispendido pelos sistemas de bombeamento apresenta valores elevados e que podem onerar a operação dos sistemas de abastecimento de água realizada pelas companhias de saneamento. Assim, esta pesquisa está centrada no desenvolvimento de uma metodologia para análise da eficiência energética desses sistemas. O procedimento metodológico foi desenvolvido para uma tipologia genérica de sistema composta de dois reservatórios, inferior e superior, um conjunto motobomba e uma adutora, responsável pelo transporte de água entre eles. Foram avaliadas 96 possibilidades geométricas para esse sistema, formadas a partir da combinação de diferentes alturas geométricas, comprimentos e diâmetros da linha adutora. Ainda, foram estudados três formatos de curva, com quatro volumes de consumo diário distintos, em duas situações, início e fim de projeto. O algoritmo Shuffled Complex Evolution – SCE-UA foi empregado para obter a regra de operação otimizada do sistema de bombeamento e a função-objetivo foi formulada para representar os custos de energia para 20 anos de operação somado aos custos de instalação do sistema de bombeamento (adutora, reservatório superior e conjunto motobomba). Além disso, foram calculados índices e indicadores para facilitar o entendimento e a avaliação da eficiência energética de sistemas de bombeamento. A partir da análise dos resultados dos sistemas cuja operação foi otimizada, e dos resultados dos índices e indicadores, foram estabelecidos critérios e equações que podem ser utilizados para análise da operação, dimensionamento e eficiência energética de sistemas de bombeamento de água. Também, foi desenvolvida uma metodologia para a estimativa da energia mínima que um sistema de bombeamento pode consumir se todos os critérios de eficiência energética forem satisfeitos, ou seja, quando todas as grandezas que compõem o cálculo da energia forem determinadas a partir de critérios otimizados. Essa metodologia foi aplicada em dois cenários: projetos de sistemas de bombeamento de água e diagnóstico de sistemas de bombeamento de água existentes. Na primeira abordagem, o indicador se mostrou útil para inferir sobre consumo de energia e, inclusive, definir o diâmetro ótimo da linha adutora com maior ponderação. Já na segunda abordagem, o indicador tem potencial para ser utilizado na definição da linha de base do sistema e pode auxiliar a tomada de decisão e gestão hidroenergética desses sistemas. / The energy consumed by the pumping systems has high values and can overload the operation of the water supply systems carried out by the sanitation companies. Thus, this research is focused on the development of a methodology to analyze the energy efficiency of these systems. The methodological procedure was developed for a generic system composed of two reservoirs, upper and lower, pumping system and a pipeline, responsible for transporting water between the reservoirs. It was evaluated 96 geometric possibilities for this system, formed from the combination of different static heights, lengths and diameters of the pipeline. Also, three curve formats were studied, with four distinct daily consumption volumes, in two situations, beginning and end of the project. The Shuffled Complex Evolution (SCE-UA) algorithm was employed to obtain the optimal operating rule for the pumping system and the objective function was formulated to represent the energy costs for 20 years of operation plus the pumping system installation costs (pipeline, upper reservoir and pumping system). In addition, indexes and indicators were calculated to facilitate the understanding and evaluation of the energy efficiency of pumping systems. Based on the analysis of the results of the systems whose operation was optimized, and the results of indexes and indicators, criteria and equations were established that can be used to analyze the operation, design and energy efficiency of water pumping systems. Also, a methodology was developed to estimate the minimum energy that a pumping system can consume if all the energy efficiency criteria are met, that is, when all the quantities that compose the energy calculation are determined from optimized criteria. This methodology was applied in two scenarios: projects of water pumping systems and diagnosis of existing water pumping systems. In the first approach, the indicator was useful to infer about energy consumption and, even, to define the optimum diameter of the most heavily weighted pipeline. In the second approach, the indicator has the potential to be used in the definition of the baseline of the system and may help decision making and hydropower management of these systems.
4

Sistema inteligente para o controle de pressão De redes de distribuição de água abastecidas Por bombas associadas em paralelo

Barros Filho, Emânuel Guerra de 05 December 2016 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-05-26T11:40:16Z No. of bitstreams: 1 arquivototal.pdf: 8290765 bytes, checksum: 60cc04d99eb6779eb21f6ce5385803d1 (MD5) / Made available in DSpace on 2017-05-26T11:40:17Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 8290765 bytes, checksum: 60cc04d99eb6779eb21f6ce5385803d1 (MD5) Previous issue date: 2016-12-05 / The objective of this research is to develop an intelligent system based on artificial neural networks for water distribution systems that operate with pumps associated in parallel. The system aims at process automation and the definition of operating state for electric motors (on, off or with partial rotation), aiming at the same time the pressure control and reduction of electric power consumption. The developed intelligent system is a generic one, which allows the application of control structure in similar processes, and it was applied in a fully instrumented test rig that emulates a real system of water supply. The results showed that the performance of the artificial neural network is quite satisfactory, and thus can be successfully implemented in other similar water distribution systems in order to reduce consumption of water and electric energy, decrease costs of maintenance, and increase the degree of reliability of operational procedures. / O objetivo desta pesquisa é desenvolver um sistema inteligente baseado em redes neurais artificiais para redes de distribuição de água que operam com bombas associadas em paralelo. O sistema tem por finalidade a automação do processo e a definição do estado de funcionamento dos motores elétricos (ligado, desligado ou com rotação parcial), visando simultaneamente ao controle de pressão e à redução do consumo de energia elétrica. O sistema inteligente desenvolvido é genérico, o que permite a aplicação da estrutura de controle em processos semelhantes, e foi aplicado em uma bancada experimental totalmente instrumentalizada que emula um sistema real de abastecimento de água. Os resultados mostraram que o desempenho da rede neural artificial é bastante satisfatório, e, assim, poderá ser implementada com sucesso em outros sistemas de distribuição de água similares, a fim de proporcionar redução do consumo de água e energia elétrica, diminuição dos custos de manutenção e aumento do grau de confiabilidade dos procedimentos operacionais.
5

Sistemas de bombeamento de água com velocidade de rotação variável

Kuritza, Jóice Cristini January 2017 (has links)
O consumo de energia dispendido pelos sistemas de bombeamento apresenta valores elevados e que podem onerar a operação dos sistemas de abastecimento de água realizada pelas companhias de saneamento. Assim, esta pesquisa está centrada no desenvolvimento de uma metodologia para análise da eficiência energética desses sistemas. O procedimento metodológico foi desenvolvido para uma tipologia genérica de sistema composta de dois reservatórios, inferior e superior, um conjunto motobomba e uma adutora, responsável pelo transporte de água entre eles. Foram avaliadas 96 possibilidades geométricas para esse sistema, formadas a partir da combinação de diferentes alturas geométricas, comprimentos e diâmetros da linha adutora. Ainda, foram estudados três formatos de curva, com quatro volumes de consumo diário distintos, em duas situações, início e fim de projeto. O algoritmo Shuffled Complex Evolution – SCE-UA foi empregado para obter a regra de operação otimizada do sistema de bombeamento e a função-objetivo foi formulada para representar os custos de energia para 20 anos de operação somado aos custos de instalação do sistema de bombeamento (adutora, reservatório superior e conjunto motobomba). Além disso, foram calculados índices e indicadores para facilitar o entendimento e a avaliação da eficiência energética de sistemas de bombeamento. A partir da análise dos resultados dos sistemas cuja operação foi otimizada, e dos resultados dos índices e indicadores, foram estabelecidos critérios e equações que podem ser utilizados para análise da operação, dimensionamento e eficiência energética de sistemas de bombeamento de água. Também, foi desenvolvida uma metodologia para a estimativa da energia mínima que um sistema de bombeamento pode consumir se todos os critérios de eficiência energética forem satisfeitos, ou seja, quando todas as grandezas que compõem o cálculo da energia forem determinadas a partir de critérios otimizados. Essa metodologia foi aplicada em dois cenários: projetos de sistemas de bombeamento de água e diagnóstico de sistemas de bombeamento de água existentes. Na primeira abordagem, o indicador se mostrou útil para inferir sobre consumo de energia e, inclusive, definir o diâmetro ótimo da linha adutora com maior ponderação. Já na segunda abordagem, o indicador tem potencial para ser utilizado na definição da linha de base do sistema e pode auxiliar a tomada de decisão e gestão hidroenergética desses sistemas. / The energy consumed by the pumping systems has high values and can overload the operation of the water supply systems carried out by the sanitation companies. Thus, this research is focused on the development of a methodology to analyze the energy efficiency of these systems. The methodological procedure was developed for a generic system composed of two reservoirs, upper and lower, pumping system and a pipeline, responsible for transporting water between the reservoirs. It was evaluated 96 geometric possibilities for this system, formed from the combination of different static heights, lengths and diameters of the pipeline. Also, three curve formats were studied, with four distinct daily consumption volumes, in two situations, beginning and end of the project. The Shuffled Complex Evolution (SCE-UA) algorithm was employed to obtain the optimal operating rule for the pumping system and the objective function was formulated to represent the energy costs for 20 years of operation plus the pumping system installation costs (pipeline, upper reservoir and pumping system). In addition, indexes and indicators were calculated to facilitate the understanding and evaluation of the energy efficiency of pumping systems. Based on the analysis of the results of the systems whose operation was optimized, and the results of indexes and indicators, criteria and equations were established that can be used to analyze the operation, design and energy efficiency of water pumping systems. Also, a methodology was developed to estimate the minimum energy that a pumping system can consume if all the energy efficiency criteria are met, that is, when all the quantities that compose the energy calculation are determined from optimized criteria. This methodology was applied in two scenarios: projects of water pumping systems and diagnosis of existing water pumping systems. In the first approach, the indicator was useful to infer about energy consumption and, even, to define the optimum diameter of the most heavily weighted pipeline. In the second approach, the indicator has the potential to be used in the definition of the baseline of the system and may help decision making and hydropower management of these systems.
6

Comportamento elétrico, mecânico e hidráulico de um sistema de bombeamento sob o enfoque da eficiência energética

Guimarães, Ronaldo 24 January 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This thesis aims to present a methodology for comparing the performance electrical, mechanical and hydraulic under the focus of the energy efficiency of pumping systems controlled by valves of strangulation or by the frequency converters. The trigger is held by engines of the line standard or high efficiency. Therefore, this paper presents the simulation in domain of time from a computer platform called ATP (Alternative Transient Program). Complementing the aspects earlier, the validation of proposal modeling, is performed by comparing the simulated values and those from the tests. Finally, it should be emphasized that the laboratory experiments were performed in the laboratory for energy efficiency of the Faculty of Electrical Engineering of the Federal University of Uberlândia. / Esta dissertação tem por objetivo apresentar uma metodologia de comparação do desempenho elétrico, mecânico e hidráulico, sob o enfoque da eficiência energética, de sistemas de bombeamento controlados por válvulas de estrangulamento ou por inversores de freqüência. O acionamento é realizado pelos motores da linha padrão ou de alto rendimento. Neste sentido, este trabalho apresenta a simulação no domínio do tempo a partir de uma plataforma computacional denominada ATP (Alternative Transient Program). Complementando os aspectos anteriores, a validação da modelagem proposta, é realizada através da comparação entre os valores simulados e aqueles oriundos dos ensaios experimentais. Finalmente, deve-se destacar que os experimentos laboratoriais foram executados no laboratório de eficiência energética da Faculdade de Engenharia Elétrica da Universidade Federal de Uberlândia. / Mestre em Ciências