• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Novo MÃtodo e Modelos Para Estudos de Fluxo de PotÃncia e de Curto-circuito / New method and models for power flow and short circuit studies.

Adriano Aron Freitas de Moura 18 January 2013 (has links)
nÃo hà / Este trabalho apresenta um novo mÃtodo de fluxo de potÃncia linear o fluxo de potÃncia linear V-teta tambÃm apresenta uma nova modelagem do gerador sÃncrono para estudos de fluxo de potÃncia trifÃsico em redes de distribuiÃÃo desequilibradas radiais e uma modelagem do gerador eÃlico sÃncrono em componentes de fase para estudos de curto-circuito em sistemas de distribuiÃÃo radiais Os resultados revelam que 1) Para o fluxo de potÃncia linear V-teta à possÃvel o cÃlculo de forma desacoplada e linear dos fluxos de potÃncia ativa e reativa no sistema Assim os erros obtidos com o fluxo de potÃncia linear V-teta sÃo em geral menores que os erros obtidos no mÃtodo clÃssico de fluxo de potÃncia CC e espera-se que o mesmo seja usado em muitas aplicaÃÃes onde o mÃtodo clÃssico de fluxo de potÃncia CC à atualmente utilizado 2) Uma nova modelagem à proposta considerando o gerador sÃncrono diretamente conectado a rede elÃtrica Uma outra modelagem jà existente na literatura considerando a conexÃo do gerador atravÃs de retificador e inversor tambÃm à usada As duas modelagens sÃo utilizadas para a realizaÃÃo de estudos de impacto dos sistemas de excitaÃÃo dos geradores sÃncronos em sistemas de distribuiÃÃo com modelagem trifÃsica Os resultados sÃo obtidos utilizando-se o sistema IEEE-13 barras A modelagem do gerador sÃncrono em componentes de fase sob condiÃÃes desequilibradas permite: a) calcular as injeÃÃes ou consumo de potÃncias ativa/reativa de cada fase na mÃquina, b) simular o gerador sÃncrono como barra do tipo PQ e como barra do tipo PV Juntamente com esses estudos uma anÃlise inÃdita e detalhada de desequilÃbrio de tensÃo inclusive com uma demonstraÃÃo matemÃtica à apresentada 3) A representaÃÃo em componentes de fase do gerador eÃlico sÃncrono nos cÃlculos de faltas de sistemas de distribuiÃÃo radiais obtÃm resultados mais precisos do que o mÃtodo tradicional das componentes simÃtricas uma vez que valores de impedÃncias mÃtuas de diferentes valores podem ser considerados na anÃlise do sistema / This thesis presents a new method of linear power flow linear power flow V-theta it also presents a new model of synchronous generator for power flow studies in three phase unbalanced radial distribution networks and modeling of wind synchronous generator in phase components for studies of short-circuit in radial distribution systems The results reveal that 1) For the linear power flow V-theta is possible to calculate like a linear and uncoupled form the active and reactive power flows in the system Thus the errors obtained with the linear power flow V-theta are usually smaller than the errors obtained in classical method of DC power flow and it is expected that the linear power flow V-theta can be used in many applications where the classical method of DC power flow is currently used 2) A new model is proposed, considering the synchronous generator directly connected to the power grid Another existing literature modeling considering the connection from the generator through rectifier and inverter is also used The two modeling are used to perform impact studies of synchronous generators excitation systems for distribution systems with three-phase modeling The results are obtained using the IEEE 13 bus - test system The modeling of synchronous generator in phase components under unbalanced conditions allow: a) calculate the active / reactive power injections in each phase of the machine b) simulate the synchronous generator as PQ bus-type and as PV bustype Along with these studies an unprecedented and detailed analysis of voltage unbalance including a mathematical proof is presented 3) the representation of synchronous windmill generators in phase components calculations in short-circuits of radial distribution systems get more accurate results than the traditional method of symmetrical components since values of mutual impedances of different values can be considered in the analysis of the system
2

Controladores Robustos LQG/LTR com AÃÃo Integral Aplicados ao Controle de Geradores EÃlicos Interligados ao Sistema de DistribuiÃÃo de Energia ElÃtrica Baseados em MÃquinas de InduÃÃo Duplamente Alimentada / Robust Controller LQG/LTR with Integral Action Applied to Control of Wind Generators connected to Distribution Power System based on Doubly Fed Induction Machine

Vandilberto Pereira Pinto 27 January 2012 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Na presente tese, propÃe-se um controlador robusto LQG/LTR (Linear Quadratic Gaussian with Loop Transfer Recovery) com aÃÃo integral (LQG/LTRI) em uma nova aplicaÃÃo para o ajuste dos controladores do conversor do lado da mÃquina e do conversor do lado rede elÃtrica em um sistema de conversÃo eÃlica utilizando um gerador de induÃÃo duplamente alimentado (Doubly-Fed Induction Generator - DFIG). A metodologia de controle proposta assegura a robustez em relaÃÃo à rejeiÃÃo do erro de rastreamento, insensibilidade a variaÃÃes paramÃtricas, alÃm de permitir que erros de medida e modelagem sejam incorporados no projeto. Testes de robustez e desempenho foram realizados para variaÃÃes dos parÃmetros internos da mÃquina e variaÃÃes de referÃncia de velocidade. Resultados de simulaÃÃo e experimentais, obtidos em um protÃtipo de laboratÃrio com uma mÃquina de 2kW sÃo apresentados para validar e demonstrar o bom desempenho e robustez do controlador proposto comparado com os controladores clÃssicos Proporcional-Integral (PI) em um sistema de geraÃÃo eÃlica com mÃquinas DFIG. / It is proposed in this thesis a LQG/LTR robust controller (Linear Quadratic Gaussian with Loop Transfer Recovery) with integral action (LQG/LTRI) in a new application for gain tuning for the rotor side converter and grid side converter in a wind energy conversion system (WECS) with Doubly-Fed Induction Generator(DFIG). The proposed control method assures the robustness with respect to the tracking error rejection, insensitivity to parameter variations and permits that measurement and modeling errors are incorporated in the project. Robustness and performance tests were performed for variations of machine internal parameters and speed. Simulation and experimental results, obtained from a laboratory prototype that uses a 2 kW machine are presented to validate and demonstrate the robustness and performance of the proposed controller through the comparison with the proportional and integral (PI) controller employed in a wind energy conversion system with DFIG.

Page generated in 0.1218 seconds