• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 313
  • 8
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 321
  • 321
  • 321
  • 128
  • 122
  • 105
  • 93
  • 79
  • 67
  • 58
  • 57
  • 40
  • 40
  • 39
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Optimal power flow solutions using the gradient projection method

Salgado, Roberto de Souza January 1989 (has links)
Tese (doutorado) - University of Manchester. Institute of Science and Technology / Made available in DSpace on 2012-10-16T02:32:19Z (GMT). No. of bitstreams: 0
2

Placement and control of static compensators for power system stability

Silveira e Silva, Aguinaldo January 1990 (has links)
Tese (doutorado) - University of Manchester. Institute of Science and Technology / Made available in DSpace on 2012-10-16T02:57:10Z (GMT). No. of bitstreams: 0
3

Erros topologicos na estimação de Estados em sistemas de potencia: abordagem geometrica, detectabilidade e identificação

Leão, Jose Augusto January 1990 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina. Centro Tecnologico / Made available in DSpace on 2012-10-16T02:58:19Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T16:37:59Z : No. of bitstreams: 1 79161.pdf: 2828601 bytes, checksum: 202014ba9a2a7717df5e2057704620ed (MD5) / A atenção do trabalho se concentra no tratamento de erros de topologia na estimação de estados em sistemas de potência. O problema da estimação de estados em sistemas de potência de erros grosseiros são analisados com o uso de argumentos geométricos. Os efeitos dos erros de topologia são estudados e interpretados geometricamente. As condições para a detectabilidade dos erros são estabelecidas com o uso do conceito de medidas críticas. Um método para a detecção e localização de erros topológicos baseados na análise de sensibilidade dos resíduos com respeito aos fluxos nas linhas é proposto e testado. O método também permite o discernimento entre erros grosseiros em medidas e erros de topologia.
4

Identificação de transações não-reveladas em ambiente desregulamentado /

Agudelo Arbeláez, Angela María January 2000 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-17T11:21:36Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T19:00:00Z : No. of bitstreams: 1 152595.pdf: 2630278 bytes, checksum: f2826c0668cc41d18f1ca312638f5f08 (MD5) / Este trabalho aborda a identificação de transações bilaterais não-reveladas que podem afetar a área de controle de um Operador Independente do Sistema (OIS) , cuja função é monitorar a rede elétrica para assegurar uma operação segura do sistema de potência. Para realizar isto, o OIS deve estar informado de todas as transações que podem acontecer dentro da sua área de controle. No entanto, isto nem sempre acontece, e as áreas de controle afetadas podem não ser notificadas da existência de certas transações. Tais situações podem resultar em grandes fluxos de potência, incrementos das perdas da rede e outras conseqüências negativas à operação do sistema de potência. O método proposto baseia-se no uso da estimação de estados, que é a ferramenta básica para monitoração de sistemas de potência em tempo real, a qual é modificada para incluir as TBNRs como variáveis de estado. A extensão para identificação de TBNRs é baseada na ferramenta estatística de testes de hipóteses, centrada no uso do teorema de Bayes
5

Utilização de índices de estabilidade transitória para redespacho de geração

Oliveira, Edni Nunes de [UNESP] 08 April 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-04-08Bitstream added on 2014-06-13T19:42:06Z : No. of bitstreams: 1 oliveira_en_dr_ilha.pdf: 924867 bytes, checksum: 97724e35ffd43b7d1c06414d3ecb95d8 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Índices que mostram o quanto um sistema de energia elétrica é estável ou instável, frente a uma contingência, têm sido o objetivo de vários estudos de estabilidade transitória. Índices baseados nos conceitos de coerência, conversão transitória de energia entre energia cinética e potencial, e três índices baseados em produtos escalares entre variáveis de estado (obtidas a partir de simulações passo a passo no domínio do tempo), foram relatados como promissores. A experiência mostra que quando estes índices são aplicados individualmente, obtêm-se bons resultados apenas para casos especiais. Neste sentido, a composição destes índices (a qual considera a influência dos vários índices) é sugerida, e experiências com o uso da média aritmética destes têm apresentado melhores resultados. No entanto, é esperado que uma composição em que se valorizem os melhores índices resulte em melhor desempenho. Desta forma, este trabalho apresenta uma composição através da média ponderada, onde a composição dos índices é obtida pela soma de cada índice individual multiplicado pelo seu respectivo peso, sendo que, os pesos são obtidos a partir de um tratamento estatístico. Os índices obtidos de forma ponderada são comparados com a composição pela média. Este modo de classificação das contingências conduz a uma conclusão rápida e confiável sobre a estabilidade do sistema. Uma vez obtido uma lista de contingências perigosas, o problema consiste em proceder a realocação de geração a fim de estabilizar o sistema frente às contingências, o que leva a questão de quanto se retirar de cada máquina crítica e o quanto realocar em cada máquina não-crítica. Assim, para resolver este problema, neste trabalho é apresentada uma proposta de realocação de geração de modo iterativo, por meio de análise de sensibilidade da margem de energia. Essa realocação é... / Indices that report how much an electrical power system is stable or unstable front to a contingency, has been the object of several studies of transient stability. Indices based on the concepts of coherence, transient energy conversion between kinetic and potential energy, and three indices based in dot products of state variables (obtained starting from simulations step by step in the time domain), it has been told as promising. The experience shows that when these indices are applied individually, it is obtained good results only in special cases. In this sense the composition of these indices (which consider the influence of several indices) have been suggested, and experiences with the use of the average arithmetic of these it has been presenting better results. However, it is expected that a composition in that is valued the best indices result in better performance. This way this work presents a composition of form pondered, where the composition of the indices is obtained by the sum of each individual indices multiplied by its respective weigh. The calculations of the weights were obtained starting from a statistical. The obtained indices of pondered form were compared with the composition by the arithmetic average. This way of classification of the contingencies drives to a fast and reliable conclusion about the stability of the system. Once obtained a list of dangerous contingencies the problem consists in proceeding the shifted of generation to end of stabilizing the system front to contingencies, what takes the subject of as to leave of each critical machine and in which machines and how much to shift in the machines no-critics and in which machines. So, to solve this problem, in this work a proposal of rescheduling of generation in an iterative scheme is presented, by means of it analyzes of sensitivity of the margin of energy. That it is accomplished of the critics generators for the ...
6

Utilização de índices de estabilidade transitória para redespacho de geração /

Oliveira, Edni Nunes de. January 2004 (has links)
Orientador: Antonio Padilha Feltrin / Banca: Arlan Luiz Bettiol / Banca: Walmir de Freitas Filho / Banca: Carlos Roberto Minussi / Banca: Laurence Duarte Colvara / Resumo: Índices que mostram o quanto um sistema de energia elétrica é estável ou instável, frente a uma contingência, têm sido o objetivo de vários estudos de estabilidade transitória. Índices baseados nos conceitos de coerência, conversão transitória de energia entre energia cinética e potencial, e três índices baseados em produtos escalares entre variáveis de estado (obtidas a partir de simulações passo a passo no domínio do tempo), foram relatados como promissores. A experiência mostra que quando estes índices são aplicados individualmente, obtêm-se bons resultados apenas para casos especiais. Neste sentido, a composição destes índices (a qual considera a influência dos vários índices) é sugerida, e experiências com o uso da média aritmética destes têm apresentado melhores resultados. No entanto, é esperado que uma composição em que se valorizem os melhores índices resulte em melhor desempenho. Desta forma, este trabalho apresenta uma composição através da média ponderada, onde a composição dos índices é obtida pela soma de cada índice individual multiplicado pelo seu respectivo peso, sendo que, os pesos são obtidos a partir de um tratamento estatístico. Os índices obtidos de forma ponderada são comparados com a composição pela média. Este modo de classificação das contingências conduz a uma conclusão rápida e confiável sobre a estabilidade do sistema. Uma vez obtido uma lista de contingências perigosas, o problema consiste em proceder a realocação de geração a fim de estabilizar o sistema frente às contingências, o que leva a questão de quanto se retirar de cada máquina crítica e o quanto realocar em cada máquina não-crítica. Assim, para resolver este problema, neste trabalho é apresentada uma proposta de realocação de geração de modo iterativo, por meio de análise de sensibilidade da margem de energia. Essa realocação é ... / Indices that report how much an electrical power system is stable or unstable front to a contingency, has been the object of several studies of transient stability. Indices based on the concepts of coherence, transient energy conversion between kinetic and potential energy, and three indices based in dot products of state variables (obtained starting from simulations step by step in the time domain), it has been told as promising. The experience shows that when these indices are applied individually, it is obtained good results only in special cases. In this sense the composition of these indices (which consider the influence of several indices) have been suggested, and experiences with the use of the average arithmetic of these it has been presenting better results. However, it is expected that a composition in that is valued the best indices result in better performance. This way this work presents a composition of form pondered, where the composition of the indices is obtained by the sum of each individual indices multiplied by its respective weigh. The calculations of the weights were obtained starting from a statistical. The obtained indices of pondered form were compared with the composition by the arithmetic average. This way of classification of the contingencies drives to a fast and reliable conclusion about the stability of the system. Once obtained a list of dangerous contingencies the problem consists in proceeding the shifted of generation to end of stabilizing the system front to contingencies, what takes the subject of as to leave of each critical machine and in which machines and how much to shift in the machines no-critics and in which machines. So, to solve this problem, in this work a proposal of rescheduling of generation in an iterative scheme is presented, by means of it analyzes of sensitivity of the margin of energy. That it is accomplished of the critics generators for the ... / Doutor
7

Uma proposta para mitigação do risco de congestionamento da transmissão em sistemas hidrotérmicos

Sória, Rodrigo Vieira January 2008 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica / Made available in DSpace on 2012-10-24T02:41:40Z (GMT). No. of bitstreams: 1 254903.pdf: 1266224 bytes, checksum: 4f17773e0b335f22d0b5c743aa9cb181 (MD5) / Este trabalho apresenta uma proposta de gerenciamento do congestionamento da transmissão para sistemas hidrotérmicos com objetivo de minimizar o risco da comercialização de energia elétrica associado à incerteza de custos advindos do congestionamento da transmissão. Nesta proposta são definidas regras básicas para oferta de Contratos de Congestionamento da Transmissão, financiados com recursos do Excedente Financeiro, os quais constituem mecanismos de proteção financeira que permite aos agentes do mercado adquirir ex-ante uma capacidade para transmissão de energia elétrica. As regras elaboradas têm por princípios os fundamentos de mercado e se dividem em duas fases. A primeira fase é dedicada exclusivamente aos agentes que compartilham a energia elétrica gerada pelo pool de usinas hidrelétricas do sistema e consiste na distribuição gratuita desses contratos. A segunda fase é de livre participação para todos os agentes do mercado e consiste na realização de leilões periódicos para aquisição de tais contratos. Um exemplo de aplicação numérica, emulado a partir de um cenário baseado em estudos da operação real do sistema, é apresentado com propósito de analisar a estrutura para alocação dos Contratos de Congestionamento da Transmissão e demonstrar os resultados obtidos. This work presents a proposal of transmission congestion management for hydrothermal systems with the objective of minimizing the energy commercialization risk associated with the uncertainty of costs by transmission congestion. In this proposal there are defined basic rules to offer the Contracts of Congestion of the Transmission, which are financed by resources of the merchandising, which constitute mechanisms of hedge that allows market players to acquire ex-ante a capacity for transmission of energy. The elaborated rules follow the market foundations and they are divided into two phases. The first phase is dedicated to players that share the electricity produced by the pool of hydro electrics units of the system, which consists of the free distribution of these contracts. The second phase is open to all market players and consists of the accomplishment of periodic auctions for acquisition of such contracts. An example of numerical application, emulated with data based on studies of the real operation of the system, is presented with the purpose of analyzing the structure of allocation of the Contracts of Congestion of the Transmission and also with the aim of illustrating the proposed application.
8

Análise de bifurcações locais em sistemas elétricos de potência

Lerm, Andre Arthur Perleberg January 2000 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-18T00:06:14Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T18:02:52Z : No. of bitstreams: 1 170964.pdf: 3996205 bytes, checksum: 57ef03befbe88ec8a3a07c302dad9fb3 (MD5) / Este trabalho apresenta uma metodologia para a determinação de diagramas de bifurcação em sistemas elétricos de potência reais. Esta metodologia prevê a determinação dos pontos de equilíbrio de um sistema elétrico a partir do seu conjunto de equações algébrico-diferencial, em que os valores de referência dos reguladores automáticos de tensão e outros controladores sejam mantidos constantes ao longo de toda a análise efetuada. Este procedimento permite que as curvas potência/tensão obtidas sejam equivalentes aos diagramas de bifurcação da teoria de bifurcações, tornando a análise coerente com esta. A proposição de análise de sistemas reais, por outro lado, fundamenta-se no uso de uma modelagem realista dos componentes que possuem uma participação decisiva no processo de instabilidade de um sistema, tais como reguladores de tensão, limitadores de sobrecorrente de campo, limitadores de subcorrente de campo e compensadores de corrente reativa. A metodologia proposta é utilizada na simulação de dois sistemas elétricos. O primeiro, refere-se a um sistema hipotético de 3 barras, útil para a compreensão de alguns fenômenos relacionados ao processo de instabilidade de um sistema elétrico. O segundo sistema refere-se ao sistema sul brasileiro reduzido, com a representação de 213 barras e 20 geradores. Os geradores deste sistema possuem representação detalhada de RATs, ESPs, limitadores de tensão e corrente de campo, bem como limites de corrente de armadura. Os resultados obtidos e apresentados através de diversas figuras demonstram a importância da modelagem proposta no processo de identificação de margens de estabilidade realistas para um sistema elétrico.
9

Implementação de modelos de cargas especiais em programas de fluxo de potência

Freitas, Luiz Carlos de January 1985 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-15T23:11:38Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T15:05:52Z : No. of bitstreams: 1 191506.pdf: 4715798 bytes, checksum: 1dc4073ef22b8d9b7602f149ab0f484e (MD5)
10

Ajuste coordenado dos sinais estabilizadores em sistemas de potencia multimaquinas

Teive, Raimundo Celeste Ghizoni January 1991 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina. Centro Tecnologico, Programa de Pós-Graduação em Engenharia Elétrica / Made available in DSpace on 2012-10-16T04:26:54Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T17:20:34Z : No. of bitstreams: 1 84643.pdf: 3005294 bytes, checksum: 56179868e12b89b77600ae5d5862c515 (MD5) / A presente dissertação apresenta um método de ajuste dos parâmetro dos sinais estabilizadores de sistemas de potência (ESP) derivados da velocidade e da potência elétrica em sistemas de potência multimáquinas. O ajuste é feito de forma coordenada, considerando as interações dinâmicas entre as máquinas, e visa posicionar os auto-valores associados aos modos eletro-mecânicos instáveis ou pouco amortecidos do sistema. A estrutura de controle adotada e descentralizada, isto é, composta de controladores locais (ESP's) que medem saídas locais e atuam somente sobre entradas locais. O método para posicionamento de pólos é interativo sendo que, em cada iteração, os valores de todos os controladores selecionados são ajustados. Considera-se que o numerador da função de transferência do ESP é quadrático, admitindo-se tanto o caso de zeros reais quanto de zeros complexos. Neste último caso, o problema de determinação dos parâmetros da função de transferência do ESP torna-se subdeterminado, e uma técnica de projeções ortogonais é aplicada para determinar o ajuste que apresenta o mínimo desvio em relação a um ajuste proposto. O método também permite o ajuste dos parâmetros dos ESP's quando o número de estabilizadores é menor do que o número de máquinas, dada a seleção prévia das máquinas a serem equipadas com ESP. A validação do método proposto é feita através de sua aplicação a três sistemas.

Page generated in 0.0881 seconds