Avaliação da conversão da energia fotovoltaica em sistemas isolados

OLIVEIRA, Kleber Carneiro de January 2007 (has links)
Made available in DSpace on 2014-06-12T17:39:29Z (GMT). No. of bitstreams: 2 arquivo6912_1.pdf: 2837512 bytes, checksum: b5cc7e4c872a99fdbcdd55d799817492 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / Esta dissertação apresenta a importância do uso da energia solar fotovoltaica em relação ao impacto ambiental causado pelas fontes de energia convencionais. O fato da energia solar fotovoltaica ser uma energia livre de poluentes e crescente devido à diminuição dos preços dos painéis fotovoltaicos a deixa em condições de competir com as outras fontes de energia. São apresentados aspectos gerais sobre geração fotovoltaica e são discutidos o princípio de funcionamento, o processo de fabricação, os tipos de células solares e as características elétricas dos módulos fotovoltaicos. Também é dada ênfase a um estudo sobre como obter o ponto de máxima potência nos painéis fotovoltaicos. Os métodos de rastreamento do ponto de máxima potência dos módulos fotovoltaicos são discutidos detalhadamente. Resultados de simulações são apresentados com a finalidade de avaliar os métodos apresentados. Algumas variações dos métodos são apresentadas e um resumo dos resultados de simulações é apresentado em tabelas. Os métodos de rastreamento são comparados com o objetivo de implementar a melhor técnica a ser aplicada ao sistema fotovoltaico. Além disso, são apresentadas algumas topologias de conversores que podem ser usadas em um sistema fotovoltaico. Estas topologias são comparadas em termos de eficiência do sistema, já levando em conta o método de rastreamento escolhido anteriormente. Para isso, um breve estudo de perdas nos dispositivos semicondutores também é desenvolvido. Finalmente, é apresentado o sistema fotovoltaico escolhido para um sistema de irrigação
2

Desenvolvimento de um sistema de aquecimento ambiente para uma caravana baseado num bomba de calor

Castro, Márcio Filipe Gonçalves January 2010 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2010
3

Comparação do desempenho de duas bombas acopladas diretamente a geradores fotovoltaicos / Performance comparison of two pumps directcly coupled to photovoltaic generators

Steigleder, Marco Antônio January 2006 (has links)
No Brasil, assim como em outros países que recebem abundantes quantidades de radiação solar durante todo o ano, há um grande potencial para os sistemas que usam a tecnologia fotovoltaica para promover o bombeamento de água. Entretanto, a escolha dos conjuntos de motores e bombas mais adequados para cada situação passa pela análise do desempenho dos sistemas de bombeamento. Portanto, devem ser analisadas tanto as melhores configurações de geradores fotovoltaicos destinados a operar os conjuntos formados pelos motores e bombas, quanto às eficiências das bombas e da conversão fotovoltaica. Nesse trabalho são apresentadas medidas e comparações do desempenho de dois sistemas de bombeamento diretamente acoplados a geradores fotovoltaicos. Para tanto, foi construída uma bancada destinada a realizar uma série de experimentos. Um dos sistemas usou uma bomba centrífuga acoplada a um gerador fotovoltaico formado por três módulos fotovoltaicos. O outro, utilizou uma bomba volumétrica de diafragma acoplada a um único módulo fotovoltaico. Os experimentos foram conduzidos em duas etapas distintas. A primeira foi feita com os motores acoplados a uma fonte de potência em corrente contínua e serviu para a determinação das curvas de desempenho de cada uma das bombas, das curvas dos sistemas, assim como das curvas de corrente (I) e de tensão (V) de cada um dos motores que acionavam as bombas. A segunda foi realizada com os sistemas acoplados diretamente aos geradores fotovoltaicos. A determinação da configuração dos geradores fotovoltaicos destinados a acionar os diferentes sistemas de bombeamento em análise nesse trabalho foi feita por meio da sobreposição das curvas de corrente e tensão dos motores e dos módulos fotovoltaicos. A parte experimental, estando os sistemas acoplados aos geradores, constou de medidas realizadas em intervalos de tempo de cinco segundos, para cada bomba e em várias alturas, das seguintes variáveis: temperatura ambiente, irradiância, temperatura dos módulos, corrente e tensão do motor, rotação do motor, temperatura da água, diferencial de pressão entre entrada e saída da bomba e vazão. As diversas alturas foram simuladas por meio da abertura e/ou fechamento de uma válvula de controle de vazão colocada na extremidade tubulação de descarga, operada manualmente. Os procedimentos adotados nessa dissertação permitiram caracterizar os sistemas de bombeamento propostos, assim como determinar quais os arranjos mais adequados para operar cada sistema. Verificou-se que o melhor arranjo para operar o conjunto motor e bomba centrífuga foi aquele formado por três módulos fotovoltaicos ligados em paralelo, enquanto que a melhor opção para operar o conjunto motor e bomba de diafragma foi com somente um módulo fotovoltaico. De posse dos dados medidos foi possível determinar as eficiências: instantâneas, máximas instantâneas e diárias da conversão fotovoltaica assim como dos conjuntos motores e bombas, em diferentes alturas. Relativamente à conversão fotovoltaica, verificou-se que o conjunto motor e bomba centrífuga operou com eficiência instantânea máxima de 5,74% e eficiência diária de 4,70%, enquanto que o conjunto motor e bomba volumétrica de diafragma operou com eficiência instantânea máxima de 7,66% e eficiência diária de 5,82%. Relativamente à eficiência dos conjuntos motores e bombas, verificou-se que o conjunto motor e bomba centrífuga operou com eficiência instantânea máxima de 19,19% e eficiência diária de 16,79%, enquanto que o conjunto motor e bomba volumétrica de diafragma operou com eficiência instantânea máxima de 38,88% e eficiência diária de 34,30%. Verificou-se ainda que a altura foi determinante na eficiência do conjunto motor e bomba centrífuga e pouco influenciou na eficiência do conjunto motor e bomba de diafragma. Além dessas, outras considerações sobre o comportamento dos sistemas de bombeamento ao longo de um dia também foram ser registrados, tais como: limiares de irradiância para início e final de vazão, correntes de pico ou de arranque dos motores e correntes de início de vazão ou escoamento. / In Brazil as well as in other countries which receive a great amount of solar radiation during all year long there is a great potential for the systems which use the photovoltaic technology for water pumping. However, the performance of the motors and pumps should be accordingly analyzed for each situation. Therefore, should be analyzed the best configurations of photovoltaic arrays which will be used to drive the motors and pumps as well as the efficiency of the pumps and of the photovoltaic conversion. This work shows the measurements made during the experiences and compares the performance of two water pumping systems directly coupled to the photovoltaic arrays. A laboratory test facility was built to evaluate the photovoltaic pumping systems. One of the systems used a centrifugal pump directly coupled to an array assembled with three photovoltaic modules. The other system used a volumetric diaphragm pump directly coupled to an only one photovoltaic module. The experiences were made in two stages. On the first stage the motors and pump were coupled to a DC power source. In this stage all the experiments and data were used to evaluate the characteristic performance of the pumps as well as their current and voltage performances. On the second stage the motors and pumps were directly coupled to the photovoltaic arrays. The determination of the best array to be used to drive the different sets of motors and pumps were made by superimposing the current and voltage curves of the motors to the current and voltage curves of the photovoltaic arrays. The following measurements of the variables were made with the motors and pumps directly coupled to the photovoltaic arrays: weather temperature, solar radiation, cell and module temperature, current and voltage of the motors, velocity of the motors in rpm, water temperature, pressure differential between entrance and exit of the pump and water flow. All the experiences were made for several pump heads and the measurements were made at each five seconds. The several pump heads were simulated by a control valve manually operated. The procedures adopted in that work allowed characterizing the proposed pumping systems, as well as determining which the arrays more adapted to operate each system. It was verified that the best array to operate the motor and centrifugal pump set was that formed by three photovoltaic modules connected in parallel, while the best option to operate the motor and diaphragm pump set was with only a photovoltaic module. With all the measured data was possible to determinate the instantaneous efficiency, the maximum instantaneous efficiency and the daily efficiency of the photovoltaic conversion as well as of the motors and pumps sets. Relatively to the photovoltaic conversion, it was verified that motor and centrifugal pump set operated with a maximum instantaneous efficiency of 5,74% and a daily efficiency of 4,70%, while motor and volumetric diaphragm pump operated with a maximum instantaneous efficiency of 7,66% and a daily efficiency of 5,82%. Relatively to the efficiency of motors and pumps sets, it was verified that the motor and centrifugal pump set operated with a maximum instantaneous efficiency of 19,19% and a daily efficiency of 16,79%, while the group motor and bomb diaphragm volumetric operated with a maximum instantaneous efficiency of 38,88 % and a daily efficiency of 34,30%. It was also verified that the head pumping is strongly decisive in the efficiency of motor and centrifugal pump set and little influenced in the efficiency of motor and volumetric diaphragm pump set. A series of considerations about the behavior of the pumping systems along the day could also be registered, such as: irradiance threshold for the beginning and flow stop, peak current of the motors and current for the beginning of flow.
4

Comparação do desempenho de duas bombas acopladas diretamente a geradores fotovoltaicos / Performance comparison of two pumps directcly coupled to photovoltaic generators

Steigleder, Marco Antônio January 2006 (has links)
No Brasil, assim como em outros países que recebem abundantes quantidades de radiação solar durante todo o ano, há um grande potencial para os sistemas que usam a tecnologia fotovoltaica para promover o bombeamento de água. Entretanto, a escolha dos conjuntos de motores e bombas mais adequados para cada situação passa pela análise do desempenho dos sistemas de bombeamento. Portanto, devem ser analisadas tanto as melhores configurações de geradores fotovoltaicos destinados a operar os conjuntos formados pelos motores e bombas, quanto às eficiências das bombas e da conversão fotovoltaica. Nesse trabalho são apresentadas medidas e comparações do desempenho de dois sistemas de bombeamento diretamente acoplados a geradores fotovoltaicos. Para tanto, foi construída uma bancada destinada a realizar uma série de experimentos. Um dos sistemas usou uma bomba centrífuga acoplada a um gerador fotovoltaico formado por três módulos fotovoltaicos. O outro, utilizou uma bomba volumétrica de diafragma acoplada a um único módulo fotovoltaico. Os experimentos foram conduzidos em duas etapas distintas. A primeira foi feita com os motores acoplados a uma fonte de potência em corrente contínua e serviu para a determinação das curvas de desempenho de cada uma das bombas, das curvas dos sistemas, assim como das curvas de corrente (I) e de tensão (V) de cada um dos motores que acionavam as bombas. A segunda foi realizada com os sistemas acoplados diretamente aos geradores fotovoltaicos. A determinação da configuração dos geradores fotovoltaicos destinados a acionar os diferentes sistemas de bombeamento em análise nesse trabalho foi feita por meio da sobreposição das curvas de corrente e tensão dos motores e dos módulos fotovoltaicos. A parte experimental, estando os sistemas acoplados aos geradores, constou de medidas realizadas em intervalos de tempo de cinco segundos, para cada bomba e em várias alturas, das seguintes variáveis: temperatura ambiente, irradiância, temperatura dos módulos, corrente e tensão do motor, rotação do motor, temperatura da água, diferencial de pressão entre entrada e saída da bomba e vazão. As diversas alturas foram simuladas por meio da abertura e/ou fechamento de uma válvula de controle de vazão colocada na extremidade tubulação de descarga, operada manualmente. Os procedimentos adotados nessa dissertação permitiram caracterizar os sistemas de bombeamento propostos, assim como determinar quais os arranjos mais adequados para operar cada sistema. Verificou-se que o melhor arranjo para operar o conjunto motor e bomba centrífuga foi aquele formado por três módulos fotovoltaicos ligados em paralelo, enquanto que a melhor opção para operar o conjunto motor e bomba de diafragma foi com somente um módulo fotovoltaico. De posse dos dados medidos foi possível determinar as eficiências: instantâneas, máximas instantâneas e diárias da conversão fotovoltaica assim como dos conjuntos motores e bombas, em diferentes alturas. Relativamente à conversão fotovoltaica, verificou-se que o conjunto motor e bomba centrífuga operou com eficiência instantânea máxima de 5,74% e eficiência diária de 4,70%, enquanto que o conjunto motor e bomba volumétrica de diafragma operou com eficiência instantânea máxima de 7,66% e eficiência diária de 5,82%. Relativamente à eficiência dos conjuntos motores e bombas, verificou-se que o conjunto motor e bomba centrífuga operou com eficiência instantânea máxima de 19,19% e eficiência diária de 16,79%, enquanto que o conjunto motor e bomba volumétrica de diafragma operou com eficiência instantânea máxima de 38,88% e eficiência diária de 34,30%. Verificou-se ainda que a altura foi determinante na eficiência do conjunto motor e bomba centrífuga e pouco influenciou na eficiência do conjunto motor e bomba de diafragma. Além dessas, outras considerações sobre o comportamento dos sistemas de bombeamento ao longo de um dia também foram ser registrados, tais como: limiares de irradiância para início e final de vazão, correntes de pico ou de arranque dos motores e correntes de início de vazão ou escoamento. / In Brazil as well as in other countries which receive a great amount of solar radiation during all year long there is a great potential for the systems which use the photovoltaic technology for water pumping. However, the performance of the motors and pumps should be accordingly analyzed for each situation. Therefore, should be analyzed the best configurations of photovoltaic arrays which will be used to drive the motors and pumps as well as the efficiency of the pumps and of the photovoltaic conversion. This work shows the measurements made during the experiences and compares the performance of two water pumping systems directly coupled to the photovoltaic arrays. A laboratory test facility was built to evaluate the photovoltaic pumping systems. One of the systems used a centrifugal pump directly coupled to an array assembled with three photovoltaic modules. The other system used a volumetric diaphragm pump directly coupled to an only one photovoltaic module. The experiences were made in two stages. On the first stage the motors and pump were coupled to a DC power source. In this stage all the experiments and data were used to evaluate the characteristic performance of the pumps as well as their current and voltage performances. On the second stage the motors and pumps were directly coupled to the photovoltaic arrays. The determination of the best array to be used to drive the different sets of motors and pumps were made by superimposing the current and voltage curves of the motors to the current and voltage curves of the photovoltaic arrays. The following measurements of the variables were made with the motors and pumps directly coupled to the photovoltaic arrays: weather temperature, solar radiation, cell and module temperature, current and voltage of the motors, velocity of the motors in rpm, water temperature, pressure differential between entrance and exit of the pump and water flow. All the experiences were made for several pump heads and the measurements were made at each five seconds. The several pump heads were simulated by a control valve manually operated. The procedures adopted in that work allowed characterizing the proposed pumping systems, as well as determining which the arrays more adapted to operate each system. It was verified that the best array to operate the motor and centrifugal pump set was that formed by three photovoltaic modules connected in parallel, while the best option to operate the motor and diaphragm pump set was with only a photovoltaic module. With all the measured data was possible to determinate the instantaneous efficiency, the maximum instantaneous efficiency and the daily efficiency of the photovoltaic conversion as well as of the motors and pumps sets. Relatively to the photovoltaic conversion, it was verified that motor and centrifugal pump set operated with a maximum instantaneous efficiency of 5,74% and a daily efficiency of 4,70%, while motor and volumetric diaphragm pump operated with a maximum instantaneous efficiency of 7,66% and a daily efficiency of 5,82%. Relatively to the efficiency of motors and pumps sets, it was verified that the motor and centrifugal pump set operated with a maximum instantaneous efficiency of 19,19% and a daily efficiency of 16,79%, while the group motor and bomb diaphragm volumetric operated with a maximum instantaneous efficiency of 38,88 % and a daily efficiency of 34,30%. It was also verified that the head pumping is strongly decisive in the efficiency of motor and centrifugal pump set and little influenced in the efficiency of motor and volumetric diaphragm pump set. A series of considerations about the behavior of the pumping systems along the day could also be registered, such as: irradiance threshold for the beginning and flow stop, peak current of the motors and current for the beginning of flow.
5

Comparação do desempenho de duas bombas acopladas diretamente a geradores fotovoltaicos / Performance comparison of two pumps directcly coupled to photovoltaic generators

Steigleder, Marco Antônio January 2006 (has links)
No Brasil, assim como em outros países que recebem abundantes quantidades de radiação solar durante todo o ano, há um grande potencial para os sistemas que usam a tecnologia fotovoltaica para promover o bombeamento de água. Entretanto, a escolha dos conjuntos de motores e bombas mais adequados para cada situação passa pela análise do desempenho dos sistemas de bombeamento. Portanto, devem ser analisadas tanto as melhores configurações de geradores fotovoltaicos destinados a operar os conjuntos formados pelos motores e bombas, quanto às eficiências das bombas e da conversão fotovoltaica. Nesse trabalho são apresentadas medidas e comparações do desempenho de dois sistemas de bombeamento diretamente acoplados a geradores fotovoltaicos. Para tanto, foi construída uma bancada destinada a realizar uma série de experimentos. Um dos sistemas usou uma bomba centrífuga acoplada a um gerador fotovoltaico formado por três módulos fotovoltaicos. O outro, utilizou uma bomba volumétrica de diafragma acoplada a um único módulo fotovoltaico. Os experimentos foram conduzidos em duas etapas distintas. A primeira foi feita com os motores acoplados a uma fonte de potência em corrente contínua e serviu para a determinação das curvas de desempenho de cada uma das bombas, das curvas dos sistemas, assim como das curvas de corrente (I) e de tensão (V) de cada um dos motores que acionavam as bombas. A segunda foi realizada com os sistemas acoplados diretamente aos geradores fotovoltaicos. A determinação da configuração dos geradores fotovoltaicos destinados a acionar os diferentes sistemas de bombeamento em análise nesse trabalho foi feita por meio da sobreposição das curvas de corrente e tensão dos motores e dos módulos fotovoltaicos. A parte experimental, estando os sistemas acoplados aos geradores, constou de medidas realizadas em intervalos de tempo de cinco segundos, para cada bomba e em várias alturas, das seguintes variáveis: temperatura ambiente, irradiância, temperatura dos módulos, corrente e tensão do motor, rotação do motor, temperatura da água, diferencial de pressão entre entrada e saída da bomba e vazão. As diversas alturas foram simuladas por meio da abertura e/ou fechamento de uma válvula de controle de vazão colocada na extremidade tubulação de descarga, operada manualmente. Os procedimentos adotados nessa dissertação permitiram caracterizar os sistemas de bombeamento propostos, assim como determinar quais os arranjos mais adequados para operar cada sistema. Verificou-se que o melhor arranjo para operar o conjunto motor e bomba centrífuga foi aquele formado por três módulos fotovoltaicos ligados em paralelo, enquanto que a melhor opção para operar o conjunto motor e bomba de diafragma foi com somente um módulo fotovoltaico. De posse dos dados medidos foi possível determinar as eficiências: instantâneas, máximas instantâneas e diárias da conversão fotovoltaica assim como dos conjuntos motores e bombas, em diferentes alturas. Relativamente à conversão fotovoltaica, verificou-se que o conjunto motor e bomba centrífuga operou com eficiência instantânea máxima de 5,74% e eficiência diária de 4,70%, enquanto que o conjunto motor e bomba volumétrica de diafragma operou com eficiência instantânea máxima de 7,66% e eficiência diária de 5,82%. Relativamente à eficiência dos conjuntos motores e bombas, verificou-se que o conjunto motor e bomba centrífuga operou com eficiência instantânea máxima de 19,19% e eficiência diária de 16,79%, enquanto que o conjunto motor e bomba volumétrica de diafragma operou com eficiência instantânea máxima de 38,88% e eficiência diária de 34,30%. Verificou-se ainda que a altura foi determinante na eficiência do conjunto motor e bomba centrífuga e pouco influenciou na eficiência do conjunto motor e bomba de diafragma. Além dessas, outras considerações sobre o comportamento dos sistemas de bombeamento ao longo de um dia também foram ser registrados, tais como: limiares de irradiância para início e final de vazão, correntes de pico ou de arranque dos motores e correntes de início de vazão ou escoamento. / In Brazil as well as in other countries which receive a great amount of solar radiation during all year long there is a great potential for the systems which use the photovoltaic technology for water pumping. However, the performance of the motors and pumps should be accordingly analyzed for each situation. Therefore, should be analyzed the best configurations of photovoltaic arrays which will be used to drive the motors and pumps as well as the efficiency of the pumps and of the photovoltaic conversion. This work shows the measurements made during the experiences and compares the performance of two water pumping systems directly coupled to the photovoltaic arrays. A laboratory test facility was built to evaluate the photovoltaic pumping systems. One of the systems used a centrifugal pump directly coupled to an array assembled with three photovoltaic modules. The other system used a volumetric diaphragm pump directly coupled to an only one photovoltaic module. The experiences were made in two stages. On the first stage the motors and pump were coupled to a DC power source. In this stage all the experiments and data were used to evaluate the characteristic performance of the pumps as well as their current and voltage performances. On the second stage the motors and pumps were directly coupled to the photovoltaic arrays. The determination of the best array to be used to drive the different sets of motors and pumps were made by superimposing the current and voltage curves of the motors to the current and voltage curves of the photovoltaic arrays. The following measurements of the variables were made with the motors and pumps directly coupled to the photovoltaic arrays: weather temperature, solar radiation, cell and module temperature, current and voltage of the motors, velocity of the motors in rpm, water temperature, pressure differential between entrance and exit of the pump and water flow. All the experiences were made for several pump heads and the measurements were made at each five seconds. The several pump heads were simulated by a control valve manually operated. The procedures adopted in that work allowed characterizing the proposed pumping systems, as well as determining which the arrays more adapted to operate each system. It was verified that the best array to operate the motor and centrifugal pump set was that formed by three photovoltaic modules connected in parallel, while the best option to operate the motor and diaphragm pump set was with only a photovoltaic module. With all the measured data was possible to determinate the instantaneous efficiency, the maximum instantaneous efficiency and the daily efficiency of the photovoltaic conversion as well as of the motors and pumps sets. Relatively to the photovoltaic conversion, it was verified that motor and centrifugal pump set operated with a maximum instantaneous efficiency of 5,74% and a daily efficiency of 4,70%, while motor and volumetric diaphragm pump operated with a maximum instantaneous efficiency of 7,66% and a daily efficiency of 5,82%. Relatively to the efficiency of motors and pumps sets, it was verified that the motor and centrifugal pump set operated with a maximum instantaneous efficiency of 19,19% and a daily efficiency of 16,79%, while the group motor and bomb diaphragm volumetric operated with a maximum instantaneous efficiency of 38,88 % and a daily efficiency of 34,30%. It was also verified that the head pumping is strongly decisive in the efficiency of motor and centrifugal pump set and little influenced in the efficiency of motor and volumetric diaphragm pump set. A series of considerations about the behavior of the pumping systems along the day could also be registered, such as: irradiance threshold for the beginning and flow stop, peak current of the motors and current for the beginning of flow.
6

Desenvolvimento de um sistema de refrigeração ambiente para uma caravana baseado em pilhas termoeléctricas assistidas por painéis fotovoltaicos

Silva, Marco Filipe Pinto da January 2010 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2010
7

Programa computacional para dimensionamento e simulação de sistemas fotovoltaicos autônomos

Vera, Luis Horacio January 2004 (has links)
Nas últimas décadas, sistemas de suprimento de energia que utilizam recursos renováveis têm sido estudados e empregados como opção para o fornecimento de energia elétrica em comunidades isoladas em áreas remotas. Devido aos avanços da tecnologia fotovoltaica associada à diminuição de custos e maior conhecimento de seu desempenho, os sistemas fotovoltaicos apresentam-se como uma opção promissora. Neste trabalho apresenta-se o desenvolvimento de um programa computacional de dimensionamento e simulação de sistemas fotovoltaicos autônomos na linguagem de programação Visual Basic 5.0, chamado PVSize, capaz de propor, para uma certa configuração de sistema, o número de baterias e módulos com seu risco de déficit de energia. Este programa tem como finalidade facilitar a interação com o usuário, e poderá ser utilizado como uma ferramenta auxiliar no processo de escolha dos elementos do sistema e estabelecer a melhor configuração através de um acompanhamento anual com base horária dos parâmetros envolvidos. Estes elementos são caracterizados através da implementação de modelos matemáticos propostos por diferentes autores que descrevem o seu desempenho individual. A integração destes modelos através de uma metodologia apropriada levou ao desenvolvimento de um programa completo de dimensionamento e simulação de sistemas fotovoltaicos autônomos. O potencial energético solar é obtido a partir de informações das características climatológicas locais, utilizadas para gerar séries de dados de radiação a partir de modelos estatísticos O programa permite projetar sistemas de suprimento de energia elétrica que atenderão cargas comunitárias (iluminação pública e de escolas, bombeamento de água, refrigeração em centros de saúde, irrigação, telecomunicações, e mais) e cargas residenciais (iluminação, refrigeração, lazer, etc.) tornando-se uma ferramenta importante para o projeto de sistemas fotovoltaicos autônomos. A comparação dos valores obtidos através de PVSize e outros programas computacionais desenvolvidos por estabelecimentos conceituados na área apresentou uma ótima concordância. Desta forma fica demonstrada a adequação do PVSize para o dimensionamento e simulação de sistemas fotovoltaicos autônomos.
8

Programa computacional para dimensionamento e simulação de sistemas fotovoltaicos autônomos

Vera, Luis Horacio January 2004 (has links)
Nas últimas décadas, sistemas de suprimento de energia que utilizam recursos renováveis têm sido estudados e empregados como opção para o fornecimento de energia elétrica em comunidades isoladas em áreas remotas. Devido aos avanços da tecnologia fotovoltaica associada à diminuição de custos e maior conhecimento de seu desempenho, os sistemas fotovoltaicos apresentam-se como uma opção promissora. Neste trabalho apresenta-se o desenvolvimento de um programa computacional de dimensionamento e simulação de sistemas fotovoltaicos autônomos na linguagem de programação Visual Basic 5.0, chamado PVSize, capaz de propor, para uma certa configuração de sistema, o número de baterias e módulos com seu risco de déficit de energia. Este programa tem como finalidade facilitar a interação com o usuário, e poderá ser utilizado como uma ferramenta auxiliar no processo de escolha dos elementos do sistema e estabelecer a melhor configuração através de um acompanhamento anual com base horária dos parâmetros envolvidos. Estes elementos são caracterizados através da implementação de modelos matemáticos propostos por diferentes autores que descrevem o seu desempenho individual. A integração destes modelos através de uma metodologia apropriada levou ao desenvolvimento de um programa completo de dimensionamento e simulação de sistemas fotovoltaicos autônomos. O potencial energético solar é obtido a partir de informações das características climatológicas locais, utilizadas para gerar séries de dados de radiação a partir de modelos estatísticos O programa permite projetar sistemas de suprimento de energia elétrica que atenderão cargas comunitárias (iluminação pública e de escolas, bombeamento de água, refrigeração em centros de saúde, irrigação, telecomunicações, e mais) e cargas residenciais (iluminação, refrigeração, lazer, etc.) tornando-se uma ferramenta importante para o projeto de sistemas fotovoltaicos autônomos. A comparação dos valores obtidos através de PVSize e outros programas computacionais desenvolvidos por estabelecimentos conceituados na área apresentou uma ótima concordância. Desta forma fica demonstrada a adequação do PVSize para o dimensionamento e simulação de sistemas fotovoltaicos autônomos.
9

Programa computacional para dimensionamento e simulação de sistemas fotovoltaicos autônomos

Vera, Luis Horacio January 2004 (has links)
Nas últimas décadas, sistemas de suprimento de energia que utilizam recursos renováveis têm sido estudados e empregados como opção para o fornecimento de energia elétrica em comunidades isoladas em áreas remotas. Devido aos avanços da tecnologia fotovoltaica associada à diminuição de custos e maior conhecimento de seu desempenho, os sistemas fotovoltaicos apresentam-se como uma opção promissora. Neste trabalho apresenta-se o desenvolvimento de um programa computacional de dimensionamento e simulação de sistemas fotovoltaicos autônomos na linguagem de programação Visual Basic 5.0, chamado PVSize, capaz de propor, para uma certa configuração de sistema, o número de baterias e módulos com seu risco de déficit de energia. Este programa tem como finalidade facilitar a interação com o usuário, e poderá ser utilizado como uma ferramenta auxiliar no processo de escolha dos elementos do sistema e estabelecer a melhor configuração através de um acompanhamento anual com base horária dos parâmetros envolvidos. Estes elementos são caracterizados através da implementação de modelos matemáticos propostos por diferentes autores que descrevem o seu desempenho individual. A integração destes modelos através de uma metodologia apropriada levou ao desenvolvimento de um programa completo de dimensionamento e simulação de sistemas fotovoltaicos autônomos. O potencial energético solar é obtido a partir de informações das características climatológicas locais, utilizadas para gerar séries de dados de radiação a partir de modelos estatísticos O programa permite projetar sistemas de suprimento de energia elétrica que atenderão cargas comunitárias (iluminação pública e de escolas, bombeamento de água, refrigeração em centros de saúde, irrigação, telecomunicações, e mais) e cargas residenciais (iluminação, refrigeração, lazer, etc.) tornando-se uma ferramenta importante para o projeto de sistemas fotovoltaicos autônomos. A comparação dos valores obtidos através de PVSize e outros programas computacionais desenvolvidos por estabelecimentos conceituados na área apresentou uma ótima concordância. Desta forma fica demonstrada a adequação do PVSize para o dimensionamento e simulação de sistemas fotovoltaicos autônomos.
10

Estudo e desenvolvimento de um algoritmo de detec??o da opera??o ilhada para sistemas PV, aplicado a um microinversor baseado no conversor Zeta / Study and development of an antiislanding algorithm for PV systems, applied to a microinverter based on Zeta converter

Guisso, Igor Luiz 31 August 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-10-18T19:21:33Z No. of bitstreams: 1 DIS_IGOR_LUIZ_GUISSO_COMPLETO.pdf: 4785487 bytes, checksum: 7d003aa07dc904952fcd4789cfe92045 (MD5) / Made available in DSpace on 2016-10-18T19:21:33Z (GMT). No. of bitstreams: 1 DIS_IGOR_LUIZ_GUISSO_COMPLETO.pdf: 4785487 bytes, checksum: 7d003aa07dc904952fcd4789cfe92045 (MD5) Previous issue date: 2015-08-31 / This work presents a study and a development of a microinverter, based on Zeta converter, as well as, the development of an islanding detection algorithm, based on the reduction of the maximum duty cycle of the converter. The objective is to achieve a reduction on the output voltage of the microinverter, so that it is possible to detect the islanding operation when the power grid is offline. In order to validate the proposed study the project of Zeta converter is presented, as well as, the implementation of the islanding algorithm in Matlab/Simulink? platform. The algorithm developed, in this project, presents outstanding results, since the variation of the microinverter output voltage amplitude resulted in an effective technique to detect islanding, as observed by simulations, which were performed in accordance with the standard IEEE 929. / Este trabalho apresenta o estudo e o desenvolvimento de um microinversor baseado no conversor Zeta e de um algoritmo de detec??o da opera??o ilhada, baseado na redu??o do ciclo de trabalho m?ximo do conversor. O objetivo ? conseguir uma redu??o na tens?o de sa?da do microinversor, para que seja poss?vel detectar a opera??o ilhada, caso a rede el?trica de distribui??o n?o esteja mais presente. A fim de validar o estudo proposto, foi apresentado o projeto do conversor Zeta e tamb?m a implementa??o do algoritmo de detec??o da opera??o ilhada em ambiente Matlab/Simulink?. O algoritmo desenvolvido apresentou ?timo desempenho, uma vez que a varia??o na amplitude da tens?o de sa?da do microinversor resultou em uma t?cnica efetiva para a detec??o da opera??o ilhada, considerando ensaios de laborat?rio realizados segundo a norma IEEE 929, e n?o resultou em degrada??o adicional da forma de onda da corrente entregue ? rede el?trica pelo microinversor.