• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Coletor solar alternativo de concreto para aquecimento de água em aplicações agrícolas e agroindustriais

Dall'Antonia Junior, Luiz Carlos [UNESP] 29 November 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-11-29Bitstream added on 2014-06-13T20:52:17Z : No. of bitstreams: 1 dallantoniajunior_lc_me_botfca.pdf: 464837 bytes, checksum: 17a18aa81cbdc6fc6cee6b24c67e95c7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho descreve a construção de um coletor solar alternativo de concreto de tração simples (areia, cimento e pedra), para aplicações agrícolas e agroindustriais. o coletor é constituído de uma área de absorção 51 m2 com 470m de mangueira de polietileno para o aquecimento da água, e o armazenador da água aquecida. O sistema coletor e armazenador foi submetido a testes experimentais onde foram determinados para as estações verão e inverno, e sob três coberturas de céu aberto, parcialmente nublada e nublada: as temperatura do absorvedor em três profundidades; ganho térmico do fluido; rendimento térmico do coletor, e desempenho do armazenador. Os resultados mostram que a temperatura do absorvedor foi maior na cobertura de céu aberto, decrescendo em seqüência de profundidade 55,74ºC, 52,10C e 49,30C respectivamente, e foi menor na cobertura de céu nublado, 48,30C, 46,20C e 44,60C respectivamente; o ganho térmico do fluido de trabalho no absorvedor foi decrescente em função do aumento comprimento do condutor: o ganho foi maior no verão e em dias de céu aberto, atingindo a temperatura máxima de 52,70C, e foi menor no inverno, em dias céu nublado, atingindo a temperatura máxima de 28,50C; o rendimento térmico do coletor foi maior em dia de céu aberto: no verão 71,4% e inverno 74%; o sistema armazenador térmico, mostrou ótimo desempenho na conservação da temperatura do fluido de trabalho. Nos dias estudados houve uma redução de 10% na temperatura final da água aquecida / This paper describes the construction of an alternative sidewalk-type solar collector made of concrete (sand, cement and stone), for agriculture and agribusiness uses. The collector consists of an absorption area of 51 m2 with 470m polyethylene tubing for water heating, and a storage for warm water. The collector and storage systems were subjected to experimental tests which were determined for summer and winter, three sky conditions: open skies, partly cloudy and overcast; three depths temperature in the absorber; thermal gain of the fluid, thermal efficiency of the collector and performance of the water storage. The temperature of the absorber was higher in open sky conditions: 55,74ºC above it, decreasing in depth sequence of 52,1ºC and 49,3ºC. This temperatures of the absorber were 48,3ºC 46,2ºC and 44,6ºC respectively in a overcast days. The thermal gain of the working fluid in the absorber was decreasing with increasing length of the conductor: the gain was higher in summer and open sky days, reaching a maximum temperature of 52.7 ºC, and lowest in winter cloudy days, reaching a maximum temperature of 28.5 ºC. The collector thermal efficiency was higher in open sky days: 71.4% in summer and 74% in winter. The warm water storage system had excellent keeping temperature performance with 10% loss in the final water temperature
2

Coletor solar alternativo de concreto para aquecimento de água em aplicações agrícolas e agroindustriais /

Dall'Antonia Junior, Luiz Carlos, 1966- January 2011 (has links)
Orientador: João Francisco Escobedo / Banca: Eduardo Nardini Gomes / Banca: Alexandre Dal Pai / Resumo: O presente trabalho descreve a construção de um coletor solar alternativo de concreto de tração simples (areia, cimento e pedra), para aplicações agrícolas e agroindustriais. o coletor é constituído de uma área de absorção 51 m2 com 470m de mangueira de polietileno para o aquecimento da água, e o armazenador da água aquecida. O sistema coletor e armazenador foi submetido a testes experimentais onde foram determinados para as estações verão e inverno, e sob três coberturas de céu aberto, parcialmente nublada e nublada: as temperatura do absorvedor em três profundidades; ganho térmico do fluido; rendimento térmico do coletor, e desempenho do armazenador. Os resultados mostram que a temperatura do absorvedor foi maior na cobertura de céu aberto, decrescendo em seqüência de profundidade 55,74ºC, 52,10C e 49,30C respectivamente, e foi menor na cobertura de céu nublado, 48,30C, 46,20C e 44,60C respectivamente; o ganho térmico do fluido de trabalho no absorvedor foi decrescente em função do aumento comprimento do condutor: o ganho foi maior no verão e em dias de céu aberto, atingindo a temperatura máxima de 52,70C, e foi menor no inverno, em dias céu nublado, atingindo a temperatura máxima de 28,50C; o rendimento térmico do coletor foi maior em dia de céu aberto: no verão 71,4% e inverno 74%; o sistema armazenador térmico, mostrou ótimo desempenho na conservação da temperatura do fluido de trabalho. Nos dias estudados houve uma redução de 10% na temperatura final da água aquecida / Abstract: This paper describes the construction of an alternative sidewalk-type solar collector made of concrete (sand, cement and stone), for agriculture and agribusiness uses. The collector consists of an absorption area of 51 m2 with 470m polyethylene tubing for water heating, and a storage for warm water. The collector and storage systems were subjected to experimental tests which were determined for summer and winter, three sky conditions: open skies, partly cloudy and overcast; three depths temperature in the absorber; thermal gain of the fluid, thermal efficiency of the collector and performance of the water storage. The temperature of the absorber was higher in open sky conditions: 55,74ºC above it, decreasing in depth sequence of 52,1ºC and 49,3ºC. This temperatures of the absorber were 48,3ºC 46,2ºC and 44,6ºC respectively in a overcast days. The thermal gain of the working fluid in the absorber was decreasing with increasing length of the conductor: the gain was higher in summer and open sky days, reaching a maximum temperature of 52.7 ºC, and lowest in winter cloudy days, reaching a maximum temperature of 28.5 ºC. The collector thermal efficiency was higher in open sky days: 71.4% in summer and 74% in winter. The warm water storage system had excellent keeping temperature performance with 10% loss in the final water temperature / Mestre
3

Estudo do rendimento térmico de um aquecedor solar parabólico redondo para viabilidade de uso comercial e residencial / Study the thermal efficiency of a solar heater round parabolic for viability of comercial and residential use

Jacob Filho, Pedro [UNESP] 05 July 2016 (has links)
Submitted by PEDRO JACOB FILHO null (pjacobf@uol.com.br) on 2016-07-20T20:06:06Z No. of bitstreams: 1 Dissertacao final corrigida pós defesa 200716.pdf: 1678965 bytes, checksum: 44aa3be37ada9a276264665cb406a1bb (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-07-22T18:44:22Z (GMT) No. of bitstreams: 1 jacobfilho_p_me_guara.pdf: 1678965 bytes, checksum: 44aa3be37ada9a276264665cb406a1bb (MD5) / Made available in DSpace on 2016-07-22T18:44:22Z (GMT). No. of bitstreams: 1 jacobfilho_p_me_guara.pdf: 1678965 bytes, checksum: 44aa3be37ada9a276264665cb406a1bb (MD5) Previous issue date: 2016-07-05 / Esta dissertação teve como objetivo a utilização de uma antena parabólica de diâmetro de 2,20 m como aquecedor solar de água de fluxo contínuo. Para a realização dos experimentos foi necessária a adequação da antena de tal modo que os raios solares refletidos passassem pelo foco da mesma, contendo uma panela de pressão pintada de preto fosco em cujo interior tem uma serpentina de cobre para absorver a radiação solar. A parte experimental contou com as medidas do valor da radiação solar, temperatura de entrada e saída da água, temperatura ambiente ao sol, temperatura no foco e a velocidade do vento. Através das medidas realizadas calculou-se a taxa da quantidade de calor e do rendimento térmico obtidos com vazões de 3,6 L/h até 36 L/h com incrementos de 3,6 L/h. Para a vazão de 25,2 L/h obteve-se o melhor rendimento térmico com 44,45%, num dia típico de intensidade solar de 800 W/m² ± 10%, sem nuvens e com velocidade do vento abaixo de 2m/s. Entretanto para um dia totalmente nublado típico a radiação solar foi de 120 W/m² ± 10% e o valor da temperatura de saída da água do aquecedor foi igual ao valor da temperatura de entrada. Verificou-se, assim, a possibilidade da antena parabólica ser empregada como aquecedor solar de água com fluxo contínuo para fins comerciais e residenciais e, também, como um sistema de pré-aquecimento de fluídos. / This dissertation had as objective the use of a satellite dish diameter of 2.20 m as solar heater continuous flow of water. For the realization of experiments was necessary the adequacy of the antenna so that the solar rays reflected receipted by focus of same, containing a pressure cooker painted black opacities in whose interior has a serpentine of copper to absorb solar radiation. The experimental part featured the measures of the value of the solar radiation, input and output temperature of water, sun ambient temperature, the temperature in the focus and wind speed. Through measurements performed it was calculated the amount of heat obtained with adequate flow of 3.6 L/h up to 36 L/h with increments of 3.6 L/h. For the flow of 25,2 L/h it was obtained the best thermal efficiency with 44.45% on a typical day of solar intensity of 800 W/m ² ± 10% without clouds and wind speed below 2 m/s. However for a day totally cloudy typical solar radiation was 120 W/m ² ± 10% and the temperature of the water heater's output was equal to the value of input temperature. It was found, so the possibility of satellite dish be used as solar water heater with continuous flow for commercial and residential purposes and also as a pre-heating system fluids.
4

Projeto, constru??o e an?lise de efici?ncia t?rmica de um sistema de aquecimento solar de ?gua de baixo custo

Gomes, Marcio Rodrigues 30 April 2010 (has links)
Made available in DSpace on 2014-12-17T14:58:00Z (GMT). No. of bitstreams: 1 MarcioRG.pdf: 2932384 bytes, checksum: c0cbe1b6236ae8739d451a6c914655ac (MD5) Previous issue date: 2010-04-30 / We studied the feasibility of using a system of Solar Water Heating (SAS) with low cost, for three configurations. In configurations I and II have the collector grid absorber composed of six PVC tubes placed in parallel on the tile cement. In configuration II, the PVC tubes were transparent cover made of plastic bottles. Configuration III uses a collector composed of 12 black HDPE pipes, supported on four cement tiles 2.44 m x 0.50 m, two by two overlapping and interspersed with a filling of glass wool, comprising an area exposed to the global radiation incident of 2.44 m2, with the top two tiles painted matte black. In this configuration, the HDPE pipes replace conventional PVC pipes painted black. The total cost of SAS for configuration III, the most economical, was around $ 150.00. For the configurations tested the system of operation was thermosyphon collector. The study showed that the proposed systems have good thermal efficiency, are easy to install and handle and have low cost compared to conventional. / Estudou-se a viabilidades de utiliza??o de um Sistema de Aquecimento Solar de ?gua (SAS) de baixo custo, para tr?s configura??es. Nas configura??es I e II o coletor possui grade absorvedora composta por seis tubos de PVC em paralelo colocados sobre uma telha de fibrocimento de 2,44 m x 0,50 m, perfazendo uma ?rea de 1,22 m2. Na configura??o II, os tubos de PVC receberam cobertura transparente confeccionadas em garrafas PETs. A configura??o III utiliza um coletor composto por 12 tubos de PEAD preto, apoiados sobre quatro telhas de fibrocimento de 2,44 m x 0,50 m, sobrepostas duas a duas e intercaladas por um recheio de l? de vidro, perfazendo uma ?rea exposta ? radia??o global incidente de 2,44m2, com as duas telhas de cima pintadas de preto fosco. Nessa configura??o, os tubos de PEAD substituem os convencionais tubos de PVC pintados de preto. O custo total desses SAS, para a configura??o III, a mais econ?mica, ficou em torno de R$ 150,00. Para as configura??es testadas o regime de funcionamento do coletor foi termossif?o. O estudo demonstrou que os sistemas propostos t?m boa efici?ncia t?rmica, s?o de f?cil instala??o e manuseio e, t?m baixo custo em rela??o aos convencionais
5

Impactos da incorporação do sistema de aquecimento solar de água na habitação de interesse social: estudos de caso em municípios de pequeno porte em Minas Gerais / Impacts of incorporating solar heating of water in social housing: case studies in small towns in Minas Gerais

Silva, Izadora Cristina Corrêa 25 February 2011 (has links)
Made available in DSpace on 2015-03-26T13:28:01Z (GMT). No. of bitstreams: 1 texto completo.pdf: 5717096 bytes, checksum: fac70b2c7ad0d5d10768b79aa66a218f (MD5) Previous issue date: 2011-02-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this paper we propose a research about the implementation of the system of solar water heating systems in social housing, from the point of view of sustainability of technology adopted. Sustainability is understood in a broad sense, involving among others, the economic, social, environmental and cultural as well as the habits and customs rooted in the resident population. Just a few examples of practical application and little literature on the deployment of technologies for energy savings in social housing, especially from the standpoint of sustainability and adaptation of the population to new technologies. To this end, we seek to identify the impacts generated by the insertion of solar collectors in social housing, produced by MG-COHAB (Housing Company of Minas Gerais) Homes Program - Housing in small towns in Minas demographic General, assessing the appropriateness of incorporating solar collectors to the habits and customs of the population and possible changes in behavior resulting from the presence of this new technology into living space. We conducted three case studies, the Homes of Mercy of Caratinga, Itatiaiuçu and Dores de Campos. It was conducted in each housing a Post-Occupancy Evaluation Behavior gauge user satisfaction with respect to the installation of solar water heaters in homes. As main results we have: user satisfaction with the financial savings generated by the solar heater and the comfort afforded by the increase of the length of the shower, due to carelessness in terms of energy consumption, lack of regular maintenance of the system solar heating by the residents, the discrepancy between the use of solar heating and reduced environmental impacts. We conclude that despite the positive impacts related to economic and cultural sustainability, residents do not relate to use of solar technology with sustainability and therefore the incorporation of solar collectors is not sufficient to create an environmental awareness. These results show that the act of incorporation of the solar heater in social housing by COHAB-MG represents important social gains, but must be accompanied by an awareness campaign in order to extend the benefits to the population, characterized as an important step towards a balanced social housing, for sustainability. / Neste trabalho propõe-se uma investigação acerca da implantação do sistema de aquecimento solar de água na habitação de interesse social, sob o ponto de vista da sustentabilidade da tecnologia adotada. Entende-se a sustentabilidade num sentido amplo, que envolve entre outros, os aspectos econômicos, sociais, ambientais e culturais bem como os hábitos e costumes arraigados na população residente. Ainda há poucos exemplos de aplicação prática e pouca literatura sobre a implantação de tecnologias visando à economia de energia na habitação de interesse social, sobretudo sob o ponto de vista da sustentabilidade e da adaptação da população às novas tecnologias utilizadas. Para tanto, busca-se identificar os impactos gerados com a inserção de coletores solares na habitação de interesse social, produzida pela COHAB-MG (Companhia de Habitação de Minas Gerais) no Programa Lares - Habitação Popular, em cidades de pequeno porte demográfico em Minas Gerais, avaliando a adequação da incorporação dos coletores solares aos hábitos e costumes da população e possíveis mudanças de comportamento decorrentes da presença dessa nova tecnologia no espaço habitacional. Foram realizados três estudos de caso, nos conjuntos habitacionais de Piedade de Caratinga, Itatiaiuçu e Dores de Campos. Efetuou-se em cada conjunto habitacional uma Avaliação Pós- Ocupação Comportamental para aferir a satisfação dos usuários com relação à instalação do aquecedor solar nas habitações. Como principais resultados encontrados têm-se: a satisfação dos usuários com a economia financeira gerada pelo aquecedor solar e com o conforto propiciado pelo aumento do tempo de uso do chuveiro, decorrente da despreocupação em relação ao consumo energético; a falta de manutenção periódica do sistema de aquecimento solar pelos moradores; a desvinculação entre o uso do aquecimento solar e a redução dos impactos ambientais. Conclui-se que, apesar dos impactos positivos relacionados com a sustentabilidade econômica e cultural, os moradores não relacionam a utilização da tecnologia solar com a sustentabilidade e, portanto, a incorporação dos coletores solares não é suficiente para criar uma consciência ambiental. Esses resultados mostram que a ação de incorporação do aquecedor solar na habitação de interesse social pela COHAB-MG representa importantes ganhos sociais, mas deve ser acompanhada de um trabalho de conscientização com a finalidade de ampliar os benefícios concedidos à população, caracterizando-se assim como um importante passo na busca de uma habitação social equilibrada, em prol da sustentabilidade.
6

O aquecedor solar brasileiro : teoria e pratica em prol de uma transferencia de tecnologia sustentavel / The Brazilian solar heater : theory and practice in favor of a sustainable transfer of technology

Gatica Rispoli, Italo Alberto 14 April 2008 (has links)
Orientador: Carlos Alberto Mariotoni / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-11T03:43:35Z (GMT). No. of bitstreams: 1 GaticaRispoli_ItaloAlberto_D.pdf: 6435454 bytes, checksum: 44d0ad6b7c73d5524af7689e79c72fd8 (MD5) Previous issue date: 2008 / Resumo: Esta pesquisa representa uma contribuição à área de recursos hídricos, energéticos e ambientais, buscando prover subsídio técnico ao planejamento energético pelo lado da demanda, atuando favoravelmente na estabilidade dos sistemas elétricos convencionais. Estudou-se a redução do custo fabril de um aquecedor solar de linha industrializada, que apresente adequado desempenho na estação fria do ano. Para isto, foi necessário revisar o tema da irradiação solar e paralelamente ensaiar protótipos e materiais. O resultado final desta pesquisa reúne subsídios aos estudantes de engenharia civil, ambiental, arquitetura, projetistas, fabricantes e vendedores da tecnologia termo solar. Ainda foi possível modelar uma linha sustentável de financiamento para a classe média brasileira sem prejuízo do banco credor. Palavras-chave: irradiação solar, energia limpa, sustentabilidade, aquecedor solar, transfer~ncia de tecnologia, tecnologia apropriada / Abstract: This research represents a contribution to the hydric resources, energetics and environmental, serving as a technical aid to the energetical planning per the demand side, acting favorably on the stability of the conventional electrical systems. It has been studied a reduction on the manufacturing cost of an industrialized solar heater that performs well during the cold season of the year, being necessary to review the solar radiation subject and at the same time test. prototypes and materiais. The final result of this research gathers aid to civil, environmental engineering students, as well to architecture students, designers, thermo solar technology makers and salespeople. It was still possible to model a sustainable credit line for the Brazilian middle class, with no loss to the bank. Key words: solar radiation, clean energy, sustainability, solar heater, technology transference, appropriated technology / Doutorado / Recursos Hidricos, Energeticos e Ambientais / Doutor em Engenharia Civil

Page generated in 0.0732 seconds