• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de desempenho do dispositivo de medida de resistividade elétrica em laboratório

Pregnolato, Marluci Cristina [UNESP] 18 August 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-08-18Bitstream added on 2015-03-03T12:06:08Z : No. of bitstreams: 1 000803388.pdf: 1529467 bytes, checksum: 2e8ae4a31ab46740cfbe1b2a2dd3da7d (MD5) / A resistividade elétrica vem sendo cada vez mais utilizada nos ensaios de investigação ambiental, sendo essa grandeza uma importante medida para a análise qualitativa da presença de contaminantes no subsolo. No entanto, muito são os fatores intervenientes na resistividade elétrica, os quais são geralmente estudados de forma isolada em laboratório para possibilitar a interpretação dos resultados de campo. Assim, o objetivo dessa dissertação de mestrado é descrever o funcionamento e as características construtivas do dispositivo de resistividade visando contribuir para a construção de um dispositivo para uso em campo e avaliar, em laboratório: a resposta do dispositivo através da obtenção das curvas de verificação desse equipamento para as temperaturas de 19 a 25ºC; realizar o estudo do potencial elétrico do dispositivo em meio aquoso para quatro concentrações diferentes; e avaliar o impacto do diâmetro do corpo de prova na obtenção da resistividade elétrica pelo módulo de resistividade e pelas placas circulares de cobre. Os resultados de potencial elétrico em meio aquoso apresentaram uma redução do raio de tensões resultantes do funcionamento do dispositivo com o aumento da concentração do meio em virtude da maior facilidade de propagação dos elétrica menores. As análises de potencial elétrico em meio aquoso possibilitaram o dimensionamento corpo de prova para realização dos ensaios em laboratório, sendo este de 155mm de diâmetro. Com os resultados obtidos para a areia estudada verificou-se que a geometria do corpo de prova se sobrepõe a técnica utilizada para a realização da medida em laboratório. Isso ocorre devido à diferente distribuição das tensões no interior dos corpos de prova, ou seja, os valores de resistividade elétrica obtidos no corpo de prova maior são inferiores aos valores obtidos no corpo de prova menor para a mesma condição de ensaio, sendo uma possível explicação... / The electrical resistivity has being used in tests for environmental site characterization once this measure is a qualitative manner to asses of the presence of contaminants in the subsurface. However, there are many intervenient factors in the electrical resistivity, which are usually studied separately in the laboratory in order to lead the interpretation of field test data. The goal of this master thesis is to describe the operation and the characteristics of resitivity device designed to contribute to the construction of in situ test tool. Furthermore, evaluate in the laboratory; the response of this tool through the curves of verification equipment for temperatures 19-25ºC; make the study of the electrical potential of these tool in an aqueous medium for four different concentrations and evaluate the impact of the diameter of test body in obtaining the electrical resistivity by the resistivity module and circular copper plates. The results electrical potential in an aqueous sample showed a reduction of the radius of the voltages resulting from the response device with the concentration of salt in the water due to the ease of propagation of electrons to values lower electrical resistivity. Analyses of the electrical potential in aqueous medium allowed the sizing test body for the tests in the laboratory, which is 155mm in diameter. The results obtained with sand studied led to conclusion the geometry of the specimen overlies the technique used to perform the measurement in a laboratory sand. It is due to different distribution of stresses within the specimens, e.g., the values of electrical resistivity obtained in the larger sample are lower than the values obtained in the lower sample of evidence for the same test condition. Probably it happens because the major sample has a greater volume of soil and so the soil available for the propagation of the stremlines and hence the electrons cross paths with lower resistance to the...
2

Análise dos potenciais de superfície gerados no solo por um sistema monofilar com retorno por terra

Caminha Júnior, Isidoro Casal [UNESP] 03 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-03Bitstream added on 2014-06-13T19:02:04Z : No. of bitstreams: 1 caminhajr_ic_dr_botfca.pdf: 615155 bytes, checksum: 4ff7ea58157517f7d519fb8bf5cd1214 (MD5) / O objetivo desta pesquisa foi analisar os dados de potenciais de superfície gerados no solo por uma rede monofilar com retorno por terra – MRT, os quais poderiam provocar fibrilação ventricular no ser humano, causada pela menor corrente de curtocircuito que vier a ser injetada no sistema de aterramento, seja pela tensão de passo, ou pelo contato com a estrutura energizada, denominada de tensão de toque. A pesquisa foi realizada na Universidade Federal de Mato Grosso do Sul no Campus de Campo Grande – MS, utilizando-se um protótipo da rede MRT, construída de acordo com as normas da Empresa Energética de Mato Grosso do Sul (ENERSUL). No período de 1996 a 1998 foram realizadas semanalmente medições dos potenciais de superfície sobre os sistemas de aterramento de alta e baixa tensão, considerando estes sistemas isolados e interligados, resultando num total de 6.864 medições de tensão de passo e 246 medições da tensão de toque. Os menores valores calculados de corrente de curto-circuito que poderiam gerar potenciais de passo e toque e provocar fibrilação ventricular no ser humano foram, indicaram que a tensão de toque é a mais perigosa. Os maiores valores de tensão de passo e tensão de toque, foram os responsáveis pelos menores valores da corrente de curto-circuito, que podem provocar a fibrilação ventricular . Estes valores ocorreram em sua maioria nas medições da tensão de passo realizadas no aterramento de alta tensão desconectado do aterramento de baixa tensão, tendo uma forte tendência destes valores no sentido sul, concordando com os menores valores de resistividade superficial. / The objective of this research was to analyze the surface potentials generated data in the soil by a single wire network with return for earth - MRT, which can provoke ventriculated fibrilation in the human being, it causing the smallest short circuit current than it comes to be injected in the ground layering system, it be for the step tension, or through contact in the structure with tension, denominated of touche tension. The research was been accomplished in the Federal University of Mato Grosso do Sul Campus of Campo Grande - MS, utiling a prototype of the MRT network built in accordance with the norms of the Energy Company of Mato Grosso do Sul (ENERSUL). In the period from 1996 to 1998 weekly readings of surface potentials on ground layering system was taken for the high and lowers tension, considering these systems isolated and joyned, resulting in a total of 6.864 readings of step tension and 246 touche tension. The smallest calculated values of short circuit current that can generate step potentials, touche, ventriculated fibrilation in the human being were, respectively, 1,92 kA and 0,46 kA, indicating that the touch tension is the most dangerous. The highest values of step tension and touch tension, it were the responsible for the smallest values of the short circuit current, that can provoke the ventriculated fibrilation. These values occurred in its majority in the readings of the step tension realized in the ground layering of the high tension disconnected of the lower tension, having a strong tendency of these values in the south direction, agreeing with the smallest values of surfacial resistivity.

Page generated in 0.1102 seconds