• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comportement de l'interface sols-structure sous sollicitations cycliques : application au calcul des fondations profondes

Tali, Brahim 14 October 2011 (has links) (PDF)
Ce travail de thèse porte sur l'étude du comportement de l'interface sol-structure sous sollicitations cycliques. Pour cela, un important programme expérimental à la sonde-pieu, mise en place dans des massifs de sable siliceux en chambre d'étalonnage, a été réalisé. On s'est intéressé, particulièrement, à l'évolution du frottement latéral et de la résistance enpointe à grand nombre de cycles (100 000 cycles), en faisant varier l'état initial du massif (état de densité et contrainte de consolidation) et les paramètres de chargement (amplitude du déplacement cyclique). Lors des essais à déplacement contrôlé, un renforcement important du frottement latéral à grand nombre de cycles a été observé pour les faibles valeurs de résistance en pointe initiale. Ce renforcement n'a quasiment pas été observé avant par les auteurs, car l'accent a été mis sur la phase de dégradation (autour de 1000cycles). Il est attribué à une forte dilatance partiellement empêchée. En revanche, pour les fortes valeurs de résistance en pointe, le renforcement à grand nombre de cycles diminue considérablement. Cette diminution est liée à l'effet des particules fines créées lors du fonçage. Celles-ci jouent le rôle de cimentation/scellement de la surface latérale de la sonde pieu en diminuant sa rugosité. Par ailleurs, des essais à force contrôlée ont été réalisés afin d'étudier la stabilité des pieux. Enfin, des lois empiriques d'évolution du frottement latéral et de la résistance en pointe ont été proposées afin de reproduire les évolutions observées expérimentalement. Ces lois d'évolution ont été intégrées dans un modèle de calcul de pieu sous chargement cyclique de type t-z. Les premières simulations effectuées montrent un bon accord entre le modèle et les résultats expérimentaux à petit nombre de cycles
2

Etude en chambre d'étalonnage du frottement sol-pieu sous grands nombres de cycles. Application au calcul des fondations profondes dans les sols fins saturés / Study of soil-pile friction, in a calibration chamber, under large number of cycles. Application to design of deep foundations in saturated clays

Muhammed, Rawaz Dlawar 07 October 2015 (has links)
Ce travail de thèse porte sur l’étude du comportement de l’interface sol-pieu sous sollicitations cycliques dans les sols fins. Dans ce cadre, un important programme expérimental a été réalisé en chambre d’étalonnage, à partir d’une sonde-pieu et d’un piézocône testés dans des massifs d’argile saturée. Pour réaliser cette étude, on a, en particulier, développé un consolidomètre prototype pour la reconstitution des massifs d’argile. On s’est intéressé plus particulièrement, lors de chargements cycliques réalisés à déplacement contrôlé, aux évolutions du frottement local mobilisé à l’interface sol-pieu et de la résistance en pointe. L’étude expérimentale a permis de mettre en évidence l’influence des paramètres clés sur le comportement observé et, plus spécifiquement, sur l’évolution des propriétés de frottement d’interface. On s’est intéressé, en particulier, à l’influence de l’amplitude du chargement cyclique, de la fréquence des sollicitations, ainsi que du nombre de cycles appliqués. L’accent a été mis sur le cas des grands nombres de cycles, typiquement quelques centaines de milliers, encore peu étudié dans la littérature. Il faut également ajouter l’étude de l’influence du niveau des contraintes initiales appliquées au massif. Les résultats expérimentaux ont permis de mettre en évidence, après une phase de dégradation initiale, une phase de renforcement du frottement local. Ce type de comportement n’a pas encore été décrit dans la littérature. La phase de dégradation est attribuée à l’augmentation progressive de la surpression interstitielle à l’interface au cours des cycles, tandis que la phase de renforcement est attribuée à la dissipation progressive de la surpression interstitielle. Par ailleurs, un essai de chargement cyclique sur un piézocône a été réalisé afin de quantifier précisément la variation des surpressions interstitielles à l’interface sol-pieu et dans le massif, lors des différentes phases de chargement, et ainsi valider les interprétations faites concernant les phases de dégradation et de renforcement. / This Ph.D. dissertation focuses on the behavior of the pile-soil interface under cyclic loading. In this context, an experimental program was conducted on the Navier calibration chamber using an instrumented pile-probe and a piezocone installed in saturated clay samples. In order to carry out this study, we developed, In particular a slurry consolidomètre prototype to reconstitute fully saturated clay samples. Special attention was given, during displacement controlled cyclic tests, to local friction evolution mobilized at the pile-soil interface and mobilized tip résistance. The experimental study has allowed the demonstration of the influence of the key parameters on the observed behavior and more specifically, on the local friction at the interface. We examined, in particular, the influence of amplitude of cyclic displacement, the frequency of cyclic loading and the applied number of cycles. Emphasis was put on the case of large number of a few hundred thousand of cycles that is still little studied in the literature. We also study the influence of initial consolidation pressure. The experimental results allowed us to identify, after an initial phase of stress softening, a new phase of stress hardening of local friction. This behavior is not yet described in the literature. The stress softening phase is related to the progressive generation of pore water pressure while the stress hardening, for its part, is related to a gradual dissipation of the generated pore water pressure. Furthermore, a complete sequence of monotonic and cyclic tests were conducted on a piezocone in order to quantify, in a precise manner, the generated pore water pressure at the pile-soil interface during different loading phases and thus validate interpretations given for stress-softening and stress-hardening phases based on the observed results.
3

Comportement de l'interface sols-structure sous sollicitations cycliques : application au calcul des fondations profondes / Behaviour of the soil-structure interface under cyclic axial loading : application to the deeps fondations computation

Tali, Brahim 14 October 2011 (has links)
Ce travail de thèse porte sur l'étude du comportement de l'interface sol-structure sous sollicitations cycliques. Pour cela, un important programme expérimental à la sonde-pieu, mise en place dans des massifs de sable siliceux en chambre d'étalonnage, a été réalisé. On s'est intéressé, particulièrement, à l'évolution du frottement latéral et de la résistance enpointe à grand nombre de cycles (100 000 cycles), en faisant varier l'état initial du massif (état de densité et contrainte de consolidation) et les paramètres de chargement (amplitude du déplacement cyclique). Lors des essais à déplacement contrôlé, un renforcement important du frottement latéral à grand nombre de cycles a été observé pour les faibles valeurs de résistance en pointe initiale. Ce renforcement n'a quasiment pas été observé avant par les auteurs, car l'accent a été mis sur la phase de dégradation (autour de 1000cycles). Il est attribué à une forte dilatance partiellement empêchée. En revanche, pour les fortes valeurs de résistance en pointe, le renforcement à grand nombre de cycles diminue considérablement. Cette diminution est liée à l'effet des particules fines créées lors du fonçage. Celles-ci jouent le rôle de cimentation/scellement de la surface latérale de la sonde pieu en diminuant sa rugosité. Par ailleurs, des essais à force contrôlée ont été réalisés afin d'étudier la stabilité des pieux. Enfin, des lois empiriques d'évolution du frottement latéral et de la résistance en pointe ont été proposées afin de reproduire les évolutions observées expérimentalement. Ces lois d'évolution ont été intégrées dans un modèle de calcul de pieu sous chargement cyclique de type t-z. Les premières simulations effectuées montrent un bon accord entre le modèle et les résultats expérimentaux à petit nombre de cycles / We study in this present work the behavior of the soil-structure interface under large number of cycles (100 000 cycles). An important program with a probe-pile jacked into the beds of sand was carried out in calibration chamber. We interested particularly on the evolution of local skin friction and tip resistance at different initial state of beds (initial density and confining pressure) and the parameters of the load (cyclic displacement amplitude). We conducted an important part of the experimental work under axial cyclic displacement controlled test which allows studying the large number of cycles. After the degradation phase, already observed by several authors (about 1000 cycles), an important re-increase in the skin friction at large cyclic number was observed at low values of initial tip resistance.This re-increase is attributed to a high dilation of sand around the probe. However, for high values of initial tip resistance there is almost not re-increase in the skin friction. This is due tothe formation of a shear band around the probe made of crushed sand. These reduce theroughness of the probe by cementing/sealing. In addition to the displacement-controlled tests, we conducted the load-controlled tests in order to study the stability of the pile. The results showed a good agreement with the displacement-controlled tests. Finally, empirical model of evolution of skin friction and tip resistance have been proposed in order to reproduce the experimental results. This model was incorporated into a computational model of pile under cyclic axial loading. The first simulations showed a good agreement with the experimental results at low number of cycles

Page generated in 0.0398 seconds