• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • No language data
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

HUMAN CARDIOVASCULAR RESPONSES TO ARTIFICIAL GRAVITY TRAINING

Stenger, Michael Brian 01 January 2005 (has links)
Human cardiovascular adaptations to microgravity include decreased plasma volume, exercise capacity, baroreflex function as well as decreased orthostatic tolerance upon return to a gravity environment. Several countermeasures have been proposed and tested, although currently none have been developed to prevent post-spaceflight orthostatic intolerance (OI). Artificial gravity (AG) generated by short-radius centrifugation (SRC) has been proposed as a countermeasure to OI as well as other cardiovascular alterations. Methods: Fifteen men and fourteen women underwent three weeks of daily (5 days a week) exposure to intermittent (1.0 to 2.5 Gz) artificial gravity on a 1.9m human powered centrifuge (HPC) at the NASA Ames Research Center. Half the subjects exercised (active) to power the HPC while half rode passively (passive). A combination head-up tilt (HUT) and lower body negative pressure (LBNP) test was used to determine orthostatic tolerance before and after training. Oscillatory LBNP (OLBNP) was used at seven frequencies (0.01 to 0.15 Hz) for two minutes each to assess the dynamic responses of the cardiovascular system to orthostatic stress, before and after AG training. Results: Training improved overall tolerance in the group of subjects by 13% (pandlt;0.05); men were more tolerant than were women (pandlt;0.05); and active subjects were more improved than passive subjects (pandlt;0.05). Mechanisms of improvement appear to be through decreased total peripheral resistance (TPR) and increased stroke volume after training, and increased responsiveness of TPR to fluid shifts (faster changes in TPR to changes in calfcircumference [CC] and OLBNP after training). There was no change in spontaneous baroreflex sensitivity (BRS, calculated by sequence method) or number of sequences per number of heart beats (NNS), although BRS analysis did indicate that stimulation to the cardiac baroreceptors during 1.0 Gz and 2.5 Gz centrifugation was no different than supine control and 70?? HUT, respectively. Taken together, these results suggest that AG training improved tolerance through training of local mechanisms in the peripheral vasculature, or extrinsic control of peripheral vascular resistance, rather than through changes of autonomic control of heart rate.
2

HUMAN CARDIOVASCULAR RESPONSES TO ARTIFICIAL GRAVITY VARIABLES: GROUND-BASED EXPERIMENTATION FOR SPACEFLIGHT IMPLEMENTATION

Howarth, Mark 01 January 2014 (has links)
One countermeasure to cardiovascular spaceflight deconditioning being tested is the application of intermittent artificial gravity provided by centripetal acceleration of a human via centrifuge. However, artificial gravity protocols have not been optimized for the cardiovascular system, or any other physiological system for that matter. Before artificial gravity protocols can be optimized for the cardiovascular system, cardiovascular responses to the variables of artificial gravity need to be quantified. The research presented in this document is intended to determine how the artificial gravity variables, radius (gravity gradient) and lower limb exercise, affect cardiovascular responses during centrifugation. Net fluid (blood) shifts between body segments (thorax, abdomen, upper leg, lower leg) will be analyzed to assess the cardiovascular responses to these variables of artificial gravity, as well as to begin to understand potential mechanism(s) underlying the beneficial orthostatic tolerance response resulting from artificial gravity training. Methods: Twelve healthy males experienced the following centrifuge protocols. Protocol A: After 10 minutes of supine control, the subjects were exposed to rotational 1 Gz at radius of rotation 8.36 ft (2.54 m) for 2 minutes followed by 20 minutes alternating between 1 and 1.25 Gz. Protocol B: Same as A, but lower limb exercise (70% V02max) preceded ramps to 1.25 Gz. Protocol C: Same as A but radius of rotation 27.36 ft (8.33 m). Results: While long radius without exercise presented an increased challenge for the cardiovascular system compared to short radius without exercise, it is likely at the expense of more blood “pooling” in the abdominal region. Whereas short radius with exercise provided a significant response compared to short radius without exercise. More fluid loss occurred from the thorax and with the increased fluid loss from the thorax blood did not “pool” in the abdominal region but instead was essentially “mobilized” to the upper and lower leg. The exercise fluid shift profile presented in this document is applicable to not only artificial gravity protocol design but also proposes a mechanistic reason as to why certain artificial gravity protocols are more effective than others in increasing orthostatic tolerance.

Page generated in 0.0646 seconds