Spelling suggestions: "subject:"sparging"" "subject:"parging""
1 |
The role of colloidal particles on the migration of air bubbles in porous mediaHan, Ji-seok 15 May 2009 (has links)
The contamination of groundwater and soils has been a big issue of great interest and importance to human health. When organic compounds from leaking underground storage tanks or accidental spills on the surface infiltrate into the subsurface environment, they migrate downward through the unsaturated zone. These contaminants are dissolved into groundwater and move with groundwater flow. Thus, there is a need for remediation technologies. Air sparging is relatively cost-effective, as well as an efficient and safe technique for recovering organic contaminants in the subsurface. This technique introduces air into the subsurface system to enhance the volatilization and bioremediation of the contaminant in the groundwater system. In this operating system, the movement of air phase can take place either as a continuous air phase or as discrete air bubbles. However, the present research focused on continuous air phase assumption and mass balance equations of individual phases rather than taking into account the movement of air bubbles and colloidal particle capture on discrete air-water interface. Generally colloidal particles are treated as suspended particles in the water, so the hypothesis is that the rising air bubble can collect the particles and transport them up to the water table where the pump extracts the dirty bubbles from the groundwater system to the processing unit on the ground surface. This dissertation developed a pore-scale study to model the migration of discrete air phase in the presence of colloidal particles captured on the air-water interface. The model was based on the pore-scale balance equation for forces acting on a bubble rising in a porous medium in the presence of colloids. A dimensional analysis of the phenomenon was also conducted to provide a more generalized methodology to evaluate the effect of individual forces acting on an air bubble. The results indicate that the proposed model can predict the terminal velocity of a rising bubble without or with colloidal particles and provide the effect of numbers of colloidal particles, properties of colloidal particles, and solid grain size. The results showed that the terminal velocity of a discrete bubble was affected by the attachment of particles on a bubble, and then the volatile organic compound (VOC) removal rate was changed by the various radii of a bubble and the number of colloidal particles on a bubble.
|
2 |
The role of colloidal particles on the migration of air bubbles in porous mediaHan, Ji-seok 15 May 2009 (has links)
The contamination of groundwater and soils has been a big issue of great interest and importance to human health. When organic compounds from leaking underground storage tanks or accidental spills on the surface infiltrate into the subsurface environment, they migrate downward through the unsaturated zone. These contaminants are dissolved into groundwater and move with groundwater flow. Thus, there is a need for remediation technologies. Air sparging is relatively cost-effective, as well as an efficient and safe technique for recovering organic contaminants in the subsurface. This technique introduces air into the subsurface system to enhance the volatilization and bioremediation of the contaminant in the groundwater system. In this operating system, the movement of air phase can take place either as a continuous air phase or as discrete air bubbles. However, the present research focused on continuous air phase assumption and mass balance equations of individual phases rather than taking into account the movement of air bubbles and colloidal particle capture on discrete air-water interface. Generally colloidal particles are treated as suspended particles in the water, so the hypothesis is that the rising air bubble can collect the particles and transport them up to the water table where the pump extracts the dirty bubbles from the groundwater system to the processing unit on the ground surface. This dissertation developed a pore-scale study to model the migration of discrete air phase in the presence of colloidal particles captured on the air-water interface. The model was based on the pore-scale balance equation for forces acting on a bubble rising in a porous medium in the presence of colloids. A dimensional analysis of the phenomenon was also conducted to provide a more generalized methodology to evaluate the effect of individual forces acting on an air bubble. The results indicate that the proposed model can predict the terminal velocity of a rising bubble without or with colloidal particles and provide the effect of numbers of colloidal particles, properties of colloidal particles, and solid grain size. The results showed that the terminal velocity of a discrete bubble was affected by the attachment of particles on a bubble, and then the volatile organic compound (VOC) removal rate was changed by the various radii of a bubble and the number of colloidal particles on a bubble.
|
3 |
Ultrafiltration Fouling: Impact of Backwash Frequency and Air SpargingLi, Lan 26 June 2014 (has links)
A bench-scale study was performed to optimize backwash frequency and air sparging conditions during ultrafiltration (UF) of natural surface waters in order to maximize water production and minimize irreversible fouling as well as operating and maintenance costs. Surface shear stress representing different air sparging conditions (continuous coarse bubble, discontinuous coarse bubble, and large pulse bubble sparging) was applied in combination with various backwash frequencies (0.5, 2 and 6 h) and fouling was assessed. Results indicated that air sparging with discontinuous coarse bubbles or large pulse bubbles significantly reduced the irreversible fouling rate while providing cost savings when compared to the baseline condition, which assumed a 0.5 h-backwash frequency and no air sparging during filtration. Cost savings were more pronounced at lower backwash frequencies, due to value associated with extra water produced over longer filtration times and longer membrane life resulted from fewer recovery chemical cleans because of lower irreversible fouling.
|
4 |
Ultrafiltration Fouling: Impact of Backwash Frequency and Air SpargingLi, Lan 26 June 2014 (has links)
A bench-scale study was performed to optimize backwash frequency and air sparging conditions during ultrafiltration (UF) of natural surface waters in order to maximize water production and minimize irreversible fouling as well as operating and maintenance costs. Surface shear stress representing different air sparging conditions (continuous coarse bubble, discontinuous coarse bubble, and large pulse bubble sparging) was applied in combination with various backwash frequencies (0.5, 2 and 6 h) and fouling was assessed. Results indicated that air sparging with discontinuous coarse bubbles or large pulse bubbles significantly reduced the irreversible fouling rate while providing cost savings when compared to the baseline condition, which assumed a 0.5 h-backwash frequency and no air sparging during filtration. Cost savings were more pronounced at lower backwash frequencies, due to value associated with extra water produced over longer filtration times and longer membrane life resulted from fewer recovery chemical cleans because of lower irreversible fouling.
|
5 |
Development of a Novel Air Sparging DeviceHobert, Andrew Reid 31 January 2015 (has links)
Column flotation is commonly employed in the processing and recovery of fine mineral particles due to an increase in flotation selectivity unattainable using conventional flotation methods. Such an increase in selectivity is due to the employment of wash water, minimizing hydraulic entrainment of fine gangue particles, and the presence of quiescent operating conditions assisted by the use of various air sparging technologies. High performance air spargers increase the probability of collision and attachment between air bubbles and particles, thereby improving recovery of fine and coarse mineral particles otherwise misplaced to the tailings fraction in conventional flotation cells. Although many high-pressure spargers, including the static mixer and cavitation tube, are currently employed for the aeration of column cells, a low pressure sparger capable of providing equivalent performance while resisting a reduction in aeration efficiency does not exist.
In light of escalated energy requirements for operation of air compressors necessary to provide high pressure air to existing external and internal spargers, a low-pressure and porous sparger capable of resisting plugging and scaling was developed. Following the design, construction, and optimization of such a prototype, air holdup and flotation performance testing was completed to verify the viability of the sparger as a replacement to existing aerators. Performance evaluations suggest that the sparger is capable of providing similar functionality to currently employed sparging technologies, but further work is required with regards to manipulation of the porous medium to prevent sparger fouling and sustain high aeration efficiencies. / Master of Science
|
6 |
NAPL Recovery Using CO<sub>2</sub>-Supersaturated Water Injection: Distribution of the CO<sub>2</sub> Gas PhaseDoughty, Cynthia January 2006 (has links)
Gas inFusion? is a novel remedial technology that dissolves CO<sub>2</sub> into water under pressure for NAPL recovery. As the supersaturated liquid flows through the porous medium gas evolution occurs in situ as the system returns to thermodynamic equilibrium. The evolution of gas bubbles leads to NAPL recovery by two mechanisms: 1) volatilization and 2) mobilization by the NAPL spreading in a film around the rising bubbles. Laboratory experiments by Li demonstrated that injecting the supersaturated water into a porous medium minimized the buoyancy driven flow of gas and the fingering phenomena that limit typical gas sparging. The distribution of carbon dioxide at partial pressures (p<sub>CO2</sub>) above the applicable hydrostatic pressure and the evolved gas phase were determined in two field experiments conducted in the relatively homogeneous fine to medium sand at CFB Borden. First, CO<sub>2</sub>-supersaturated water was injected into a single point located approximately 4 metres below ground surface. Then this injection was repeated with pumping of two nearby wells to see if the lateral distribution of CO<sub>2</sub> gas could be controlled hydraulically. Groundwater monitoring of p<sub>CO2</sub> above the hydrostatic pressure and geophysical surveys (neutron measurements, surface ground penetrating radar (GPR), and cross-borehole GPR) to find zones of induced gas content were supported by hydraulic monitoring and physical observations of gas bubble distribution at the water table. <br /><br /> Based on the results of these tests, enhanced CO<sub>2</sub> levels above the hydrostatic pressure were observed up to 5. 5-7. 0 m from the injection point and the gas phase up to ~5. 3 m. It was not possible to determine the impact hydraulic control had on the lateral distribution of CO<sub>2</sub> due to problems with the experiment. The distribution of the gas phase was heterogeneous with CO<sub>2</sub> gas pockets forming below low permeability layers, as evidenced by surface GPR, permeameter tests, and grain size analyses. These gas pockets accumulated until sufficient pressure built up to overcome the displacement pressure of these lower permeability layers. At this point there is evidence of CO<sub>2</sub> breakthrough in the cross-borehole GPR data and physical observations of gas bubbles at the water table. These observations are consistent with previous investigations, which indicate that although the Borden aquifer is homogeneous, distinct horizontal layering is present with sufficient variations in permeability/displacement pressure to trap and cause some lateral spreading of a gas phase. The evidence of channeling and the impact of heterogeneities on gas distribution are consistent with air sparging studies.
|
7 |
Pulsed Biosparging of the E10 Gasoline Source in the Borden AquiferLambert, Jennifer January 2008 (has links)
Air sparging is a technique used to remediate gasoline contamination. In sparging, air is injected below the target zone and removes contamination via two separate mechanisms; volatilization and biodegradation. In volatilization, the air contacts the contamination as it moves upward. The contaminant will partition to the vapor phase based on its volatility and will be removed as the air reaches the atmosphere. For biodegradation, the oxygen in the airstream is used for microbial activity. Pulsed air sparging, otherwise known as pulsed biosparging, has been found to be more effective than continuous air sparging. Pulsed biosparging enhances treatment because it induces groundwater movement and mixing.
The general mechanisms for treatment of gasoline sources using air sparging are relatively well characterized. However, air flow through the subsurface and the total hydrocarbon mass lost are difficult to predict and quantify. This project was intended to quantify the mass lost through volatilization and through biodegradation at the E10 gasoline source using pulsed biosparging, and to determine the effect of the source zone removal on downgradient dissolved BTEX concentrations.
The remedial system consisted of two major components: the air sparging system, with three injection points; and a soil gas collection system. The soil gas collection system was comprised of an airtight box that covered the source area and the monitoring wells upgradient and downgradient of the source. Off-gas from the soil gas collection system was monitored continuously using a PID. The off-gas was also sampled frequently for BTEX, pentane, and hexane to determine the hydrocarbon mass removed; and for O2 and CO2 to determine biodegradation rates.
The remedial system ran for approximately 280 hours over 33 days. Of the estimated 22.3 kg of gasoline residual in the source zone, 4.6 kg or 21% of the residual was removed via volatilization and 4.9 kg or 22% of the residual was removed via biodegradation. Leakage outside the system was estimated at less than 0.1% of the total mass. Groundwater samples were collected when the last sparged air was calculated to arrive at the row 2 downgradient fence. The average BTEX groundwater concentration after sparging was 40% of the pre-sparging concentration. The benzene mass discharge decreased 27%, the ethylbenzene mass discharge decreased 65%, the p/m-xylene mass discharge decreased 6%, and the o-xylene mass discharge decreased 5%. The mass discharge for naphthalene and TMB isomers increased 19%. However, these values fit in with long-term groundwater concentration trends. Additional sampling is recommended to determine if the sparging made a significant impact on mass discharge leaving the source.
|
8 |
NAPL Recovery Using CO<sub>2</sub>-Supersaturated Water Injection: Distribution of the CO<sub>2</sub> Gas PhaseDoughty, Cynthia January 2006 (has links)
Gas inFusion? is a novel remedial technology that dissolves CO<sub>2</sub> into water under pressure for NAPL recovery. As the supersaturated liquid flows through the porous medium gas evolution occurs in situ as the system returns to thermodynamic equilibrium. The evolution of gas bubbles leads to NAPL recovery by two mechanisms: 1) volatilization and 2) mobilization by the NAPL spreading in a film around the rising bubbles. Laboratory experiments by Li demonstrated that injecting the supersaturated water into a porous medium minimized the buoyancy driven flow of gas and the fingering phenomena that limit typical gas sparging. The distribution of carbon dioxide at partial pressures (p<sub>CO2</sub>) above the applicable hydrostatic pressure and the evolved gas phase were determined in two field experiments conducted in the relatively homogeneous fine to medium sand at CFB Borden. First, CO<sub>2</sub>-supersaturated water was injected into a single point located approximately 4 metres below ground surface. Then this injection was repeated with pumping of two nearby wells to see if the lateral distribution of CO<sub>2</sub> gas could be controlled hydraulically. Groundwater monitoring of p<sub>CO2</sub> above the hydrostatic pressure and geophysical surveys (neutron measurements, surface ground penetrating radar (GPR), and cross-borehole GPR) to find zones of induced gas content were supported by hydraulic monitoring and physical observations of gas bubble distribution at the water table. <br /><br /> Based on the results of these tests, enhanced CO<sub>2</sub> levels above the hydrostatic pressure were observed up to 5. 5-7. 0 m from the injection point and the gas phase up to ~5. 3 m. It was not possible to determine the impact hydraulic control had on the lateral distribution of CO<sub>2</sub> due to problems with the experiment. The distribution of the gas phase was heterogeneous with CO<sub>2</sub> gas pockets forming below low permeability layers, as evidenced by surface GPR, permeameter tests, and grain size analyses. These gas pockets accumulated until sufficient pressure built up to overcome the displacement pressure of these lower permeability layers. At this point there is evidence of CO<sub>2</sub> breakthrough in the cross-borehole GPR data and physical observations of gas bubbles at the water table. These observations are consistent with previous investigations, which indicate that although the Borden aquifer is homogeneous, distinct horizontal layering is present with sufficient variations in permeability/displacement pressure to trap and cause some lateral spreading of a gas phase. The evidence of channeling and the impact of heterogeneities on gas distribution are consistent with air sparging studies.
|
9 |
Pulsed Biosparging of the E10 Gasoline Source in the Borden AquiferLambert, Jennifer January 2008 (has links)
Air sparging is a technique used to remediate gasoline contamination. In sparging, air is injected below the target zone and removes contamination via two separate mechanisms; volatilization and biodegradation. In volatilization, the air contacts the contamination as it moves upward. The contaminant will partition to the vapor phase based on its volatility and will be removed as the air reaches the atmosphere. For biodegradation, the oxygen in the airstream is used for microbial activity. Pulsed air sparging, otherwise known as pulsed biosparging, has been found to be more effective than continuous air sparging. Pulsed biosparging enhances treatment because it induces groundwater movement and mixing.
The general mechanisms for treatment of gasoline sources using air sparging are relatively well characterized. However, air flow through the subsurface and the total hydrocarbon mass lost are difficult to predict and quantify. This project was intended to quantify the mass lost through volatilization and through biodegradation at the E10 gasoline source using pulsed biosparging, and to determine the effect of the source zone removal on downgradient dissolved BTEX concentrations.
The remedial system consisted of two major components: the air sparging system, with three injection points; and a soil gas collection system. The soil gas collection system was comprised of an airtight box that covered the source area and the monitoring wells upgradient and downgradient of the source. Off-gas from the soil gas collection system was monitored continuously using a PID. The off-gas was also sampled frequently for BTEX, pentane, and hexane to determine the hydrocarbon mass removed; and for O2 and CO2 to determine biodegradation rates.
The remedial system ran for approximately 280 hours over 33 days. Of the estimated 22.3 kg of gasoline residual in the source zone, 4.6 kg or 21% of the residual was removed via volatilization and 4.9 kg or 22% of the residual was removed via biodegradation. Leakage outside the system was estimated at less than 0.1% of the total mass. Groundwater samples were collected when the last sparged air was calculated to arrive at the row 2 downgradient fence. The average BTEX groundwater concentration after sparging was 40% of the pre-sparging concentration. The benzene mass discharge decreased 27%, the ethylbenzene mass discharge decreased 65%, the p/m-xylene mass discharge decreased 6%, and the o-xylene mass discharge decreased 5%. The mass discharge for naphthalene and TMB isomers increased 19%. However, these values fit in with long-term groundwater concentration trends. Additional sampling is recommended to determine if the sparging made a significant impact on mass discharge leaving the source.
|
10 |
Remediation of BTEX Contaminated Site by Air SpargingWang, Liang-wei 19 August 2004 (has links)
In this field-scale study, air sparging (AS) system was applied at a petroleum-hydrocarbon spill site to remediate contaminated soil and groundwater in situ. The objective of this study was to evaluate the effectiveness of the AS system on volatile organic compounds (VOC) removal via the volatilization mechanism. Moreover, the AS system would also enhance the in situ bioremediation process due to the increased oxygen concentration in the subsurface.
Results from the preliminary site characterization show that high concentrations of benzene and toluene were present in the subsurface in the western part of the site. Up to 15.62 and 30,957 mg/Kg of benzene and toluene were detected in soil samples, respectively. Moreover, up to 0.068 and 4.8 mg/L of benzene and toluene were observed in groundwater samples, respectively. The following remediation activities were conducted during the one-year investigation and remediation period:
1. Construction of four recovery wells were for light non-aqueous phase liquid (LNAPL) and contaminated groundwater extraction to prevent the expansion of VOC plume. The extracted groundwater was delivered to the wastewater treatment plant for treatment before discharge.
2. Installation of ten air sparging wells to enhance the removal of VOC through volatilization and biodegradation processes.
3. Conduction of (1) soil gas survey, (2) soil and groundwater sampling and analyses, and microbial enumeration periodically to evaluate the effectiveness of AS on VOC removal.
Results from the field-scale study indicate that the AS system is able to effectively contain the plume. This can be confirmed by the following findings: (1) decrease in VOC concentrations in both soil and groundwater, (2) increase in carbon dioxide and increase in oxygen concentrations in the soil gas samples, and (3) increase in bacterial population in soil samples. Results from this study indicate that AS system can effectively contain the plume and manage this petroleum hydrocarbon spill site.
|