• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da dureza e do grau de conversão de resinas compostas : efeito de fonte de luz e material /

Ribeiro, Benícia Carolina Iaskieviscz. January 2010 (has links)
Orientador: José Roberto Cury Saad / Banca: Margareth Oda / Banca: Anísio Lima da Silva / Banca: Celso Luiz de Angelis Porto / Banca: José Cláudio Martins Segalla / Resumo: A evolução dos materiais odontológicos, a interação de resinas compostas e aparelhos fotopolimerizadores motivaram a realização deste estudo. Foram selecionadas quatro resinas compostas fotopolimerizáveis indicadas para restaurações diretas, sendo três microhíbridas: Vit-l-escenceTM (Ultradent®), Amelogen® Plus (Ultradent®) e Opallis (FGM) e outra de nanopartículas: FiltekTM Z350 (3M ESPE Dental Products), todas indicadas para dentina e na cor A2. Construiram-se corpos-de-prova com dimensões de 4 mm de diâmetro e 2 mm de profundidade (ISO 4049), os quais foram polimerizados por diferentes aparelhos fotoativadores. Para o primeiro estudo, utilizou-se o Led Ultra Lume Led 2 (Ultradent®) e uma luz halógena (Ultralux - Dabi Atlante), esta com diferentes ponteiras condutoras de luz. Decorridas 24 horas, os corpos-de-prova foram submetidos ao ensaio de dureza utilizando-se um aparelho MMTT-3 Microhardness Tester (Buehler Lake Bluff, Illinois USA), com o qual foram realizadas quatro aferições na superfície do topo da amostra (dureza 1) e mais quatro na superfície de base (dureza 2) oposta à fonte de luz. Para o segundo estudo, novos corpos-de-prova foram confeccionados da mesma maneira, utilizando-se a luz halógena (Ultralux Dabi Atlante) com ponteira de vidro, um LED de terceira geração (Ultra Lume Led 5 Ultradent®) e dois leds de segunda geração: Radii-Cal (SDI) e Elipar Free LightTM 2 da 3M ESPETM. Os corpos-deprova foram submetidos ao mesmo teste, em dois tempos: imediato e após 24 horas. Para a terceira pesquisa, pela qual se avaliou o grau de conversão por FT-IR, empregando-se o espectrofotômetro Nexus FT- IR, confeccionou-se do mesmo modo outros corpos-de-prova e, decorridas 24 horas, estes foram triturados e misturados com KBr para a obtenção de pastilhas. Como parâmetro, confeccionou-se mais 20 pastilhas com resinas não curadas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Our study was motivated by the evolution of dental materials, and the interaction between composite resin and light curing units. We selected four light-curing composite resins suitable for direct restorations, in shade A2, three microhybrid (Vit-l-escenceTM - Ultradent®) (Amelogen® Plus - Ultradent ®) (Opallis - FGM) and one nanoparticles (FiltekTM Z350 - 3M ESPE Dental Products), all indicated for dentin. All specimens were built with dimensions of 4mm diameter and 2mm deep, (ISO 4049) which were irradiated by different light-curing units. For the first study, we used the Led Ultra Lume Led 2 (Ultradent®), and a halogen light (Ultralux - Dabi Atlante) with the last having different conductive tips of light. At 24 hours, samples were tested in microhardness through the device MMTT-3 Microhardness Tester (Buehler Lake Bluff, Illinois USA) where 4 measurements were performed in the top surface (hardness 1) and 4 more in the base area (hardness 2), opposite to the source of light. For the second study, new specimens were prepared in the same way, using the Light Halogen (Ultralux Dabi Atlante) with a glass pipette, a third-generation led (Ultra Lume Led 5 Ultradent®) and two second-generation LEDs: Radii-Cal (SDI) and Elipar Free LigthTM 2 (3M ESPETM). The samples were subjected to the same test in two stages: immediate and after 24 hours. For the third study, which evaluated the degree of conversion by FT-IR, using the spectrophotometer Nexus FT-IR, samples were built in the same manner and after 24 hours they were powdered and mixed with KBr, to obtain tablets. As a parameter, 20 more tablets were prepared with uncured resin. Data were collected and subjected to statistical analysis. In the first study, it was concluded that the led device (second generation) allowed polymerization and the resulting hardness values were equivalent to the halogen unit for three of the four... (Complete abstract click electronic access below) / Doutor
2

Análise de queilite actínica por espectroscopia micro FT-IR /

Carvalho, Luis Felipe das Chagas e Silva de. January 2011 (has links)
Orientador: Janete Dias Almeida / Banca: Luiz Antonio Guimarães Cabral / Banca: Cristina Kurachi / Banca: Luciane Dias de Oliveira / Banca: Fábio Ramôa Pires / Resumo: A queilite actínica (QA) é uma lesão considerada potencialmente cancerizável, localizada principalmente em lábio inferior e causada pela exposição crônica à radiação UV. A Espectroscopia FT-IR fornece informações moleculares através de fenômenos ópticos observado pela vibração de suas moléculas. Tem sido empregada em estudos biológicos para a caracterização de alterações neoplásicas. No entanto, são escassos os estudos que envolvam processos potencialmente cancerizáveis. Objetivou-se avaliar QAs através da espectroscopia micro FT-IR com relação aos seus aspectos moleculares para região de fingerprint (900-1800 cm-1) e altos números de onda (2800-3600 cm-1), e ainda verificar a análise dos componentes principais (PCA) e regressão logística binária (RLB) como modelo de diagnóstico. Foram avaliadas 14 amostras de QA e 14 amostras de mucosas normal (MN), obtendo-se 5 espectros por amostra, totalizando 140 espectros avaliados (70 de cada grupo). Os resultados demonstrados pela análise dos componentes principais revelaram pelo gráfico de scree plot que os dez primeiros PCs deveriam ser utilizados na análise. As maiores variações observadas pelo gráfico de loading plot relacionaram-se aos modos vibracionais do colágeno, ácidos nucléicos, lipídios e água confinada. O modelo de regressão logística binária mostrou 80,6% de pares concordantes para região de fingerprint e 81,7% de pares concordantes para a região de altos números de onda. Concluiu-se que a espectroscopia micro FT-IR provê características moleculares importantes das 19 amostras de QA, evidenciadas tanto na região de fingerprint como na de altos números de onda. / Abstract: Actinic cheilitis (AC) is a potentially precancerous lesion, located primarily in lower lip caused by chronic exposure to UV radiation. The FT-IR spectroscopy provides molecular information through optical properties observed by the vibration of its molecules. This technique has been used in biological studies for characterization of neoplastic tissues. However, there are few studies involving potentially cancerous processes. This study aimed to evaluate molecular changes on AC through micro FT-IR spectroscopy in fingerprint (900-1800 cm-1) and high wave numbers (2800-3600 cm- 1) region, and also to verify the principal components analysis (PCA) and binary logistic regression (BLR) as a model of diagnosis. We evaluated 14 samples of AC and 14 samples of normal mucosa (NM), resulting in 5 spectra per sample, totalling 140 spectra analyzed (70 from each group). The results demonstrated by PCA revealed by scree plot graph showed that the first ten principal components (PCs) should be used in the analysis. The largest variations observed by loading graph plot related to the vibrational modes of collagen, nucleic acids, lipids and confined water. The BLR model showed 80.6% of concordant pairs for the fingerprint region and 81.7% of concordant pairs of high wave numbers region. It was concluded that the micro FT-IR spectroscopy provides important molecular features of AC samples, evidenced both in the fingerprint and in the highwave numbers region. / Doutor

Page generated in 0.0969 seconds