Spelling suggestions: "subject:"bistatic converters"" "subject:"12static converters""
11 |
Controle de microrredes CC baseado em droop adaptativo de tensão – simulação em tempo real com control-hardware-in-loopFerreira, Rodrigo Arruda Felício 13 March 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-25T15:30:19Z
No. of bitstreams: 1
rodrigoarrudafelicioferreira.pdf: 7303630 bytes, checksum: 971316c74f1313f54e1c09c837c93e74 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-26T12:05:46Z (GMT) No. of bitstreams: 1
rodrigoarrudafelicioferreira.pdf: 7303630 bytes, checksum: 971316c74f1313f54e1c09c837c93e74 (MD5) / Made available in DSpace on 2017-04-26T12:05:46Z (GMT). No. of bitstreams: 1
rodrigoarrudafelicioferreira.pdf: 7303630 bytes, checksum: 971316c74f1313f54e1c09c837c93e74 (MD5)
Previous issue date: 2015-03-13 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta um estudo sobre alguns dos aspectos relacionados às microrredes em corrente contínua, uma alternativa para utilização de fontes renováveis de energia em sistemas de geração distribuída. Considerando que a manutenção da tensão no barramento principal das microrredes, no qual as fontes e as cargas são conectadas, é uma das questões mais importantes para a operação de modo satisfatório destes sistemas, um sistema de controle descentralizado de tensão integrando técnicas de controle por droop de tensão e de controle por modos deslizantes é proposto. Uma microrrede CC de 10 kW conectada à rede CA e composta por arranjos fotovoltaicos e bancos de baterias, dimensionada para atender uma parcela das cargas eletrônicas e de iluminação do Instituto Federal de Educação, Ciência e Tecnologia – Campus Juiz de Fora, é modelada e simulada em tempo real utilizando o conceito de simulação CHIL. Resultados experimentais utilizando controladores externos como dispositivos em teste são utilizados para analisar o comportamento do sistema em diferentes condições e para validação da metodologia proposta. Além disso, é apresentado um estudo das técnicas de análise de estabilidade de tensão para sistemas em corrente contínua. Por fim, é apresentada uma metodologia baseada em síntese de elementos reativos utilizando conversores estáticos para estabilização ativa de sistemas CC simplificados, contendo uma fonte e uma carga do tipo potência constante. / This work presents aspects related to DC microgrids, an alternative way of using renewable energy sources in a decentralized fashion. Whereas the maintenance of the microgrid main bus voltage, in which the sources and loads are connected, is one of the most important issues for the satisfactory operation of these systems, a novel methodology for regulating DC bus voltage integrating voltage droop control and sliding mode control techniques is proposed. A grid-connected 10 kW DC microgrid containing photovoltaic arrays and a battery bank, sized to meet a portion of electronic and lighting loads of the Federal Institute of Education, Science and Technology - Campus Juiz de Fora, is modeled and simulated in real time using the concept of CHIL simulation. Experimental results using external controllers as hardware under test are used to analyze system behavior under different conditions and to validate the proposed methodology. Furthermore, a study regarding voltage stability analysis techniques applied to DC systems is presented. Finally, a methodology based on synthesis of reactive elements using static converters for active stabilization of simplified CC systems, containing one source and one constant power load, is presented.
|
12 |
Controladores discretos de tensão baseados no princípio do modelo interno aplicados a inversores trifásicos PWM / Discrete-time voltage controllers based on the internal model principle used in three-phase pwm invertersBotterón, Fernando 09 December 2005 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This thesis contributes to the analysis, project and implementation of discrete-time controllers based on the Internal Model Principle, aiming to improve the performance of three-leg three-phase PWM inverters with insulating output transformer usually found in the output stage of medium power double-conversion UPS. Initially, an investigation about issues concerning to the discrete-time models of three-phase inverters with space vector modulation and the LC filter have
been carried out. This investigation shows the impact of different switching sequences, sampling instants and filter cut-off frequency on the harmonic spectrum of sampled variables used for feedback. This is a concern when the switching frequency is low to limit the switching losses as in medium and high power UPS. In this way, this thesis proposes sampling methods that make possible to reduce the low order harmonics on the interest variables, which is relevant when state feedback is used. These methods allow to obtain discrete-time average linear models useful for the controller design. In addition, the saturation of the insulating transformer is addressed in details. The dc component arising from the digital implementation and from the circuit measures non idealities, and then amplified by an inadequate choice of the controller, may lead the transformer to saturate. In order to solve this problem, and in accordance with the Internal Model Principle, internal models adequate to the plant under consideration as well as discrete-time voltage controllers in stationary and synchronous frames which are not prone to amplify the dc component, are proposed. Another goal of this thesis is the improvement of the UPS output voltage transient
response due to linear and non linear load steps. This is obtained considering the sampling methods before mentioned, combined with internal models with reduced number of poles and low sampling rate. It is demonstrated that it is possible to improve significantly the output voltage transient responses, as well as to satisfy the rigorous classification of the standard IEC62040-3 for UPS without degrading the steady state performance. In addition, these control structures have enough stability margins, as proved in each case, and they results in simple and attractive solutions to be implemented in 8 or 16 bits fixed-point arithmetic microcontrollers and DSP with reduced memory space. The feasibility of the proposed solutions is verified with experimental results demonstrating
both transient and steady-state performances. Finally, a comparative analysis of the proposed control structures, over the light of the standard IEC62040-3, is presented. / A presente tese de doutorado contribui para a análise, projeto e implementação de controladores discretos baseados no Princípio do Modelo Interno, com o intuito de aprimorar o
desempenho de inversores trifásicos PWM a três braços com transformador isolador usualmente utilizados no estágio de saída de UPS de dupla conversão de média potência. Inicialmente se realiza uma investigação sobre os aspectos relacionados à obtenção do modelo discreto de inversores trifásicos com modulação space vector e do filtro de saída. Essa investigação mostra o impacto de diferentes seqüências de comutação, instantes de amostragem e freqüência de corte do filtro no conteúdo harmônico das variáveis amostradas usadas para realimentação. Isso é uma
preocupação quando a freqüência de comutação é baixa para limitar as perdas em UPS de média e alta potência. Nesse sentido essa tese propõe métodos de amostragem que possibilitam reduzir as harmônicas de baixa ordem nas variáveis de interesse o que adquire importância quando se realiza a realimentação dos estados da planta. Esses métodos permitem a obtenção de modelos médios lineares úteis para o projeto do controlador. Além disso, a saturação do transformador de isolação é analisada em detalhe. A componente contínua oriunda da implementação digital e das não idealidades dos circuitos de medição, e amplificada por uma escolha inadequada do controlador, pode levar o transformador à saturação. Com o intuito de solucionar esse problema, e de acordo com a teoria do Princípio do Modelo Interno, são propostos modelos internos adequados à planta
em questão bem como controladores discretos de tensão em eixos estacionários e síncronos, que não tem tendência a amplificar a componente contínua. Outro dos objetivos dessa tese é o aprimoramento da resposta transitória das tensões de saída da UPS na presença de degraus de carga linear e não linear. Isso é obtido considerando-se os métodos de amostragem mencionados acima, combinado com modelos internos com número de pólos e taxa de amostragem reduzidos. Demonstra-se que é possível aprimorar significativamente a resposta transitória das tensões de
saída bem como satisfazer a exigente classificação da norma IEC62040-3 para UPS, sem degradar o desempenho de regime permanente. Além disso, essas estruturas de controle possuem suficiente margem de estabilidade, como provado em cada caso, e estas resultam em soluções simples e atrativas para serem implementadas em microcontroladores e DSP de aritmética de ponto fixo, com palavras de 8 e 16 bits e capacidade reduzida de memória. A viabilidade prática das propostas realizadas é verificada com resultados experimentais em regime permanente e transitório. Finalmente, apresenta-se uma análise comparativa das estruturas de controle propostas, sob o enfoque da norma IEC62040-3.
|
Page generated in 0.1024 seconds