Spelling suggestions: "subject:"steel, structural"" "subject:"ateel, structural""
21 |
A study of plastic analysis of steel structuresLoh, C. Y. January 1963 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1963. / Typescript. eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaf [75]).
|
22 |
Second-order analysis for imperfect structures /Koon, Chi Ming. January 2004 (has links) (PDF)
Thesis (Ph.D.) - University of Queensland, 2004. / Includes bibliography.
|
23 |
The effect of high level cyclic stresses on the fatigue properties of structural steelHubbard, Ralph Burnett, January 1963 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1963. / Typescript. eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 21-24).
|
24 |
Performance evaluation of friction damped braced steel frames under simulated earthquake loadsFiliatrault, André January 1985 (has links)
This thesis presents the results obtained from qualification tests of a new friction damping system, which has been proposed in order to improve the response of Moment Resisting Frames and Braced Moment Resisting Frames during severe earthquakes. The system basically consists of a special inexpensive mechanism containing friction brake lining pads introduced at the intersection of frame cross-braces. The main objective is to study the performance of a 3 storey Friction Damped Braced Frame model under simulated
earthquake loads.
The main members of the test frame were chosen from available hot-rolled sections and the mass selected to provide the expected fundamental frequency of a three storey Moment Resisting Frame. The seismic testing was performed on an earthquake simulator table. The experimental results are compared with the findings of an inelastic time-history dynamic analysis. Two different computer models were used for this purpose. The first one is based on an equivalent hysteretic model and is only approximate,
since it does not take into account the complete behaviour of the friction devices. A more refined computer model was then developed and the results from the two models are compared. It is found that the simpler approximate model overestimates the energy dissipated by the devices, but the inaccuracy is relatively small (10-20% in resulting member forces).
To quantify the performance of the Friction Damped Braced Frame relative
to conventional aseismic systems, an equivalent viscous damping study is made. Viscous damping is added to the Moment Resisting Frame and the Braced Moment Resisting Frame until their responses become similar to the response of the Friction Damped Braced Frame. The results show that for this purpose 38% of critical damping must be added to the Moment Resisting Frame and 12% to the Braced Moment Resisting Frame. The new system becomes more efficient as the intensity of the earthquake increases.
The economical potential of the new damping system is investigated by designing a reduced size Friction Damped Braced Frame having response characteristics which are similar to those of conventional structural systems with heavier members. For the model frames studied, the results show that if the effects of wind, live and torsion loads are neglected, it is possible to reduce the members sizes of the Friction Damped Braced Frame by 47% and still achieve a superior performance under strong earthquake, in comparison to the seismic response of the two other conventional frames with their original, heavier members.
The results, both analytical and experimental, clearly indicate the superior performance of the friction damped braced frame compared to conventional building systems. Even an earthquake record with a peak acceleration of 0.9 g causes no damage to the Friction Damped Braced Frame, while the Moment Resisting Frame and the Braced Moment Resisting frame undergo large inelastic deformations. / Applied Science, Faculty of / Civil Engineering, Department of / Graduate
|
25 |
Behaviour of bolted double angle beam connections subjected to eccentric loadsChung Wing, Philip T. C. January 1979 (has links)
No description available.
|
26 |
Cold-formed steel compression members with perforations.Abdel-Rahman, Nabil Mahmoud. January 1997 (has links)
Thesis (Ph.D) -- McMaster University, 1997. / Includes bibliographical references. Also available via World Wide Web.
|
27 |
Welded beam to column connection : the effect of axial loading and bending.Wesselingh, Bernard. January 1975 (has links) (PDF)
Thesis (M.E.) -- University of Adelaide, Department of Civil Engineering, 1978.
|
28 |
Minimum weight design of light gage steel membersSeaburg, Paul Allen. January 1969 (has links)
Thesis (Ph. D.)--University of Wisconsin--Madison, 1969. / Vita. Typescript. eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
29 |
Data for standard curve chord steel roof trussesBush, William Hewitt. January 1930 (has links) (PDF)
Thesis (Professional Degree)--University of Missouri, School of Mines and Metallurgy, 1930. / The entire thesis text is included in file. Typescript. Illustrated by author. Title from title screen of thesis/dissertation PDF file (viewed October 12, 2009)
|
30 |
Distortion-induced fatigue cracking of girder-to-crossbeam connection /Aljutaili, Dhari S. January 1900 (has links)
Thesis (M.S.)--Oregon State University, 2008. / Printout. Includes bibliographical references (leaves 32-33). Also available on the World Wide Web.
|
Page generated in 0.0696 seconds