• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Identification expérimentale de modèles de zones cohésives à partir de techniques d'imagerie thermomécanique / Identification of cohesive zone models using thermomechanical imaging techniques

Wen, Shuang 14 December 2012 (has links)
Ce travail porte sur l'identification de modèles de zones cohésives. Ces modèles, proposés initialement dans les années 60 sont maintenant de intensivement utilisés dans les simulations numériques pour rendre compte de l'initiation et de la propagation de fissures pour différents matériaux et structures.L'identification de ces modèles reste encore aujourd'hui une problématique délicate. Les développements récents de techniques d'imagerie permettent d'accéder à des champs de mesures locales (e.g. déformation et température, …). On se propose dans ce travail d'utiliser la richesse des informations issues de ces techniques d'imagerie pour mettre en place une procédure d'identification qui prenne en compte à la fois le développement de la localisation (effet de structure) mais aussi la nature des différentes irréversibilités mises en jeu (comportement thermo-mécanique). On s'intéresse à des comportements élasto-plastiques endommageables de matériaux ductiles. L'endommagement est associé à un comportement cohésif de l'interface entre les éléments volumiques supposés purement élasto-plastiques.La procédure d'identification comporte deux étapes. La première consiste à caractériser la forme et les paramètres de la loi cohésive sur des essais de traction standard à partir d'une analyse des champs mécaniques localement développés. La seconde étape consiste à vérifier la cohérence thermo-mécanique du modèle identifié en confrontant les mesures calorimétriques déduites des champs de température avec les prévisions du modèle identifié.Cette méthode est appliquée avec succès sur différents matériaux (acier Dual Phase et cuivre). Une attention particulière est portée sur la caractérisation de la longueur caractéristique qui est nécessairement introduite dans l'identification. On montre que cette longueur peut être estimée au regard des différents paramètres introduits dans les traitements d'images.Cette méthode est appliquée sur différents matériaux (acier et cuivre). Une attention particulière est portée sur la caractérisation de la longueur caractéristique qui est nécessairement introduite dans l'identification. On montre que cette longueur peut-être corrélée à l'échelle d'identification des processus d'endommagement sous-jacents. Ainsi les modèles cohésifs identifiés sont fournis au modélisateur avec l'échelle physique à laquelle ils résument l'endommagement volumique du matériau. / This work deals with the identification of cohesive zone models. These models were intially proposed in the 1960s. They are now more and more frequently used in numerical simulations to account for crack initiation and propagation in different materials and structures.The identification of these models still remains a delicate issue. The recent developments in imaging techniques now allow reaching local measurement fields (e.g. strain, temperature,…). We propose here to use the large amount of information given by these techniques to set up an identification procedure accounting for either the localization development (structural effect) and also the character of the different irreversibility sources encountered (thermo-mechanical behavior). We study damageable elasto-plastic ductile materials. Damage is associated to a cohesive behavior of the interface between volumic elements supposed to remain purely elasto-plastic.The identification procedure involves two steps. The first one consists in characterizing the shape and the parameters of the cohesive zone on tensile tests by analyzing the mechanical fields locally developed. The second one consists in checking the thermo-mechanical consistency of the identified model by confronting the calorimetric measurements deduced from temperature fields with the previsions of the identified model.This method is applied on different materials (Dual Phase steel and copper). A specific caution is conferred to the characterization of the characteristic length necessarily introduced by the identification. It is shown that this length can be estimated regarding the different parameters introduced in the image processing.
2

Développement d'un implant à géométrie variable pour le traitement des fractures du fémur proximal chez les personnes âgées / Development of an adjustable implant for proximal femoral fractures in the elderly

Billard, Rémi 21 February 2014 (has links)
Les fractures du fémur proximal de la personne âgée sont généralement fixées par des dispositifs d’ostéosynthèse. Pour les fractures particulières dites inter-trochantériennes, il est possible de fixer la fracture de manière intra-médullaire (à l’intérieur de l’os) ou de manière extra-médullaire (en dehors de l’os). Pour chaque type de traitement, les hôpitaux sont équipés des deux systèmes de fixation. Les différences de morphologie des individus impliquent l’existence de multiples références d’implants et donc de surcoûts en termes d’équipement. Dans ce travail de thèse, un implant original adaptable à la plupart des morphologies a été développé. Cet implant permettra non seulement d’offrir aux chirurgiens une souplesse au cours des interventions chirurgicales mais aussi de réduire de manière significative les stocks d’implants dans les hôpitaux. Le comportement mécanique de l’implant est étudié dans différents cas de fractures par deux approches complémentaires, une méthode numérique par Éléments Finis et une approche expérimentale mettant en oeuvre des techniques de stéréo-corrélation à partir d’images de caméras rapides. Les résultats des calculs numériques sont confrontés à ceux issus d’essais réalisés sur des fémurs synthétiques, puis cadavériques en laboratoire d’anatomie. Les comparaisons avec des implants existants montrent que ce nouveau concept d’implant permet une fixation plus stable des fragments osseux et une bonne compression du foyer de fracture. / Proximal femoral fractures in the elderly are generally fixed with osteosynthetic devices. For specific fractures called intertrochanteric, it is possible to fix the fracture in an intramedullary way (inside the bone) or in an extramedullary way (outside the bone). For each type of treatment, hospitals are equipped with the two fixing systems. The differences in physical characteristics between individuals imply the existence of multiple references implants and therefore additional costs in terms of equipment. In this thesis work,an original implant adaptable to most people has been developed. This implant will provide surgeons greater flexibility during surgery but also significantly reduce stocks implants in hospitals. The mechanical behavior of the implant is studied in different cases of fractures by two complementary approaches,a finite element analysis and an experimental study employing stereo-image correlation technique from images of high speed cameras. The results of the numerical calculation are compared with those derived from tests on synthetic femurs, then cadaver in anatomy laboratory. Comparisons with existing implants show that this new implant concept allows for a more stable fixation of bone fragments and a good compression of the fracture.

Page generated in 0.0914 seconds