1

Experiments on special-shaped CFST stub columns under axial compression

Ren, Q-X., Han, L-H., Lam, Dennis, Hou, C. January 2014 (has links)
This paper is an attempt to study the behavior of axially loaded concrete filled steel tubular (CFST) stub columns with special-shaped cross-sections, i.e. triangular, fan-shaped, D-shaped, 1/4 circular and semi-circular. A total of forty-four specimens including CFST stub columns and reference hollow steel tubular stub columns were tested. The effects of the changing steel tube wall thickness and the infill of concrete on the behavior of the composite columns were investigated. The results showed that the tested special-shaped CFST stub columns behaved in a ductile manner, and the composite columns showed an outward local buckling model near the middle section. Generally, the failure modes of these five kinds of special-shaped specimens were similar to those of the square CFST stub columns. Finally, simplified model for predicting the cross-sectional strength of the special-shaped CFST sections was discussed and proposed.
2

Compression Stability of High Strength Steel Sections with Low Strain-Hardening

YANG, Demao January 2003 (has links)
Thin-walled steel sections made from high strength thin cold-reduced G550 steel to Australian Standard AS 1397-1993 under compression are investigated experimentally and theoretically in this thesis. This thesis describes three series of compression tests performed on box-section stub columns, box-section long columns and lipped channel section columns cold-formed from high strength steel plates in 0.42 mm or 0.60 mm thickness with nominal yield stress of 550 MPa. The tests presented in this thesis formed part of an Australian Research Council research project entitled: Compression Stability of High Strength Steel Sections with Low Strain-Hardening. For the fix-ended stub column tests, a total of 94 lipped-square and hexagonal section stub columns were tested to study the influence of low strain hardening of G550 steel on the compressive section capacities of the column members. For the pin-ended long column tests, a total of 28 box-section columns were tested to study the stability of members with sections which undergo local instability at loads significantly less than the ultimate loads. For the fix-ended lipped channel section columns, a total of 21 stub and long columns were tested to study the failure resulting from local and distortional buckling with interaction between the modes. A numerical simulation on the three series of tests using the commercial finite element computer program ABAQUS is also presented as part of this thesis. The post-buckling behaviour of thin-walled compression members is investigated. The effect of changing variables, such as geometric imperfections and end boundary conditions is also investigated. The ABAQUS analysis gives accurate simulations of the tests and is in good agreement to the experimental results. Theoretical studies using finite strip methods are presented in this thesis to investigate the buckling behaviour of cold-formed members in compression. The theoretical studies provide valuable information on the local and distortional buckling stresses for use in the interaction buckling studies. The finite strip models used are the semi-analytical and spline models. As expected for the stub columns tests, the greatest effect of low strain hardening was for the stockier sections where material properties play an important role. For the more slender sections where elastic local buckling and post-local buckling are more important, the effect of low strain hardening does not appear to be as significant. The pin-ended and fix-ended long column tests show that interaction, which is between local and overall buckling in the box sections, and between local and distortional buckling in the open channel sections, has a significant effect on their member capacities. The results of the successful column tests and ABAQUS simulation have been compared with the design procedures in the Australian & New Zealand Standard for Cold-Formed Steel Structures AS&NZS 4600 and the North American Specification for Cold-Formed Steel Structural Members prepared by the American Iron and Steel Institute. The stub column tests show that the current design rules give too conservative predictions on the compressive section capacities of the column members; whereas the long column tests show that the current column design rules are unconservative if used in their current form for G550 steel. Three design proposals are presented in this thesis to account for the effects of high strength thin steels on the section and member capacities.
3

Compression Stability of High Strength Steel Sections with Low Strain-Hardening

YANG, Demao January 2003 (has links)
Thin-walled steel sections made from high strength thin cold-reduced G550 steel to Australian Standard AS 1397-1993 under compression are investigated experimentally and theoretically in this thesis. This thesis describes three series of compression tests performed on box-section stub columns, box-section long columns and lipped channel section columns cold-formed from high strength steel plates in 0.42 mm or 0.60 mm thickness with nominal yield stress of 550 MPa. The tests presented in this thesis formed part of an Australian Research Council research project entitled: Compression Stability of High Strength Steel Sections with Low Strain-Hardening. For the fix-ended stub column tests, a total of 94 lipped-square and hexagonal section stub columns were tested to study the influence of low strain hardening of G550 steel on the compressive section capacities of the column members. For the pin-ended long column tests, a total of 28 box-section columns were tested to study the stability of members with sections which undergo local instability at loads significantly less than the ultimate loads. For the fix-ended lipped channel section columns, a total of 21 stub and long columns were tested to study the failure resulting from local and distortional buckling with interaction between the modes. A numerical simulation on the three series of tests using the commercial finite element computer program ABAQUS is also presented as part of this thesis. The post-buckling behaviour of thin-walled compression members is investigated. The effect of changing variables, such as geometric imperfections and end boundary conditions is also investigated. The ABAQUS analysis gives accurate simulations of the tests and is in good agreement to the experimental results. Theoretical studies using finite strip methods are presented in this thesis to investigate the buckling behaviour of cold-formed members in compression. The theoretical studies provide valuable information on the local and distortional buckling stresses for use in the interaction buckling studies. The finite strip models used are the semi-analytical and spline models. As expected for the stub columns tests, the greatest effect of low strain hardening was for the stockier sections where material properties play an important role. For the more slender sections where elastic local buckling and post-local buckling are more important, the effect of low strain hardening does not appear to be as significant. The pin-ended and fix-ended long column tests show that interaction, which is between local and overall buckling in the box sections, and between local and distortional buckling in the open channel sections, has a significant effect on their member capacities. The results of the successful column tests and ABAQUS simulation have been compared with the design procedures in the Australian & New Zealand Standard for Cold-Formed Steel Structures AS&NZS 4600 and the North American Specification for Cold-Formed Steel Structural Members prepared by the American Iron and Steel Institute. The stub column tests show that the current design rules give too conservative predictions on the compressive section capacities of the column members; whereas the long column tests show that the current column design rules are unconservative if used in their current form for G550 steel. Three design proposals are presented in this thesis to account for the effects of high strength thin steels on the section and member capacities.
4

Numerical Investigation of Local Buckling Behavior of High Strength Steel Wide Flange Columns

Dileep Bengaluru Chandrashekhar, FNU 25 May 2022 (has links)
No description available.
5

Experimental and Analytical Studies of the Behavior of Cold-Formed Steel Roof Truss Elements

Nuttayasakul, Nuthaporn 01 December 2005 (has links)
Cold-formed steel roof truss systems that use complex stiffener patterns in existing hat shape members for both top and bottom chord elements are a growing trend in the North American steel framing industry. When designing cold-formed steel sections, a structural engineer typically tries to improve the local buckling behavior of the cold-formed steel elements. The complex hat shape has proved to limit the negative influence of local buckling, however, distortional buckling can be the controlling mode of failure in the design of chord members with intermediate unbraced lengths. The chord member may be subjected to both bending and compression because of the continuity of the top and bottom chords. These members are not typically braced between panel points in a truss. Current 2001 North American Specifications (NAS 2001) do not provide an explicit check for distortional buckling. This dissertation focuses on the behavior of complex hat shape members commonly used for both the top and bottom chord elements of a cold-formed steel truss. The results of flexural tests of complex hat shape members are described. In addition, stub column tests of nested C-sections used as web members and full scale cold-formed steel roof truss tests are reported. Numerical analyses using finite strip and finite element procedures were developed for the complex hat shape chord member in bending to compare with experimental results. Both elastic buckling and inelastic postbuckling finite element analyses were performed. A parametric study was also conducted to investigate the factors that affect the ultimate strength behavior of a particular complex hat shape. The experimental results and numerical analyses confirmed that modifications to the 2001 North American Specification are necessary to better predict the flexural strength of complex hat shape members, especially those members subjected to distortional buckling. Either finite strip or finite element analysis can be used to better predict the flexural strength of complex hat shape members. Better understanding of the flexural behavior of these complex hat shapes is necessary to obtain efficient, safe design of a truss system. The results of these analyses will be presented in the dissertation. / Ph. D.
6

Behaviour of inclined, tapered and STS square CFST stub columns subjected to axial load

Lam, Dennis, Dai, Xianghe, Han, L-H., Ren, Q-X., Li, W. January 2012 (has links)
This paper describes the finite element method using ABAQUS to model the axial compressive behaviour of inclined, tapered and straight-tapered-straight (STS) concrete filled steel tubular stub (CFST) columns with square hollow sections. The accuracy of the numerical model was verified by comparing the numerical predictions with experimental study of the 200×200×3.75 RHS filled with C60 concrete with inclined angle of 0-9° and tapered angle of 0-4°. The results show that the compressive behaviours, load vs. strain relationship and failure mode predicted by the numerical simulations were agreeable with experimental results. After the validation, a parametric study was performed with 3 typical steel hollow sections (200×200×3.75 RHS, 300×300×6.3 RHS and 400×400×8.0 RHS) and extended the inclined angle and tapered angle to 0-15° and 0-12° respectively. The parametric study highlights some of the behaviour observed in test and extends the application range. In addition, reduction factor for calculating the axial capacity of this form of CFST columns are proposed.

Page generated in 0.0355 seconds