• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização geoambiental e avaliação dos parâmetros que influenciam na mobilidade do HCH no meio poroso / Geoenvironmental characterization and assessment of parameters that influence the mobility of the HCH in porous medium.

Macedo, Letícia dos Santos 17 October 2014 (has links)
Este trabalho apresenta a caracterização geoambiental de solos de uma área contaminada, localizada no município de Santo André, Estado de São Paulo, Brasil. O objetivo foi determinar parâmetros experimentais para permitir o estudo de alguns aspectos do transporte do pesticida organoclorado Hexaclorociclohexano (HCH). A área de estudo contém células com cerca de 30.000 toneladas de um material contendo HCH em elevadas concentrações. As investigações de campo demonstram que há concentrações de HCH na água subterrânea. Em 2011, foram coletadas amostras deformadas e indeformadas de solo em quatro diferentes pontos superficiais da área contaminada, e posteriormente uma amostra composta da camada de solo de alteração de rocha (SAR), a fim de responder a questionamentos quanto à mobilidade do contaminante na área. A caracterização geoambiental, baseada em ensaios laboratoriais, foi realizada por meio das seguintes análises: análise granulométrica, limites de Atterberg, densidade específica, porosidade, umidade do solo, curva de retenção de água no solo, condutividade hidráulica, ensaio de adsorção, pH, condutividade elétrica, capacidade de troca catiônica (CTC), teor de matéria orgânica e teor de voláteis. O solo superficial da área é heterogêneo e a capacidade de adsorção dos solos analisados foi menor do que o esperado. Esta caracterização subsidiou o estudo de fluxo e transporte do HCH, por meio de simulação numérica, utilizando o programa Hydrus 1D. As simulações tiveram dois objetivos diferentes: no primeiro foi avaliado os resultados da simulação em comparação à situação atual no campo; no segundo foi avaliada a sensibilidade do transporte em função da alteração dos parâmetros obtidos experimentalmente Ks; Kd; s e (Van Genuchten); e dos parâmetros obtidos na literatura. Os resultados permitiram concluir que o modelo Hydrus 1D consegue representar a contaminação do HCH no solo. O parâmetro de degradação na água foi essencial para chegar em ordens de grandeza de concentrações próximas das identificadas em campo. Os parâmetros de degradação, difusividade, dispersividade e condutividade hidráulica são os que mais afetam os resultados finais de concentração do HCH na água subterrânea e, portanto, merecem atenção maior durante as futuras investigações. / This paper presents the geoenvironmental characterization of soils from a contaminated site, located in Santo André, São Paulo State, Brazil. The objective was to determine experimental parameters to allow the study of some aspects of transport of the organochlorine pesticide hexachlorocyclohexane (HCH). The study site contains trenches with about 30,000 tons of a material containing high concentrations of HCH. The site investigations show that there are HCH concentrations in groundwater. In 2011, disturbed and undisturbed soil samples were collected at four different surface points of the contaminated site, and then a sample of soil from rock alteration layer (SAR) was also composed for characterization in order to answer questions concerning the mobility of contaminant in the site. The environmental characterization based on laboratory tests, was performed by the following analyzes: grain size distribution, Atterberg limits, specific gravity, porosity, moisture content, water retention curve, hydraulic conductivity, pH, electrical conductivity, cation exchange capacity (CEC), organic matter content and volatile content. The surface soil of the area is heterogeneous and the adsorption capacity of the soils analyzed were lower than expected. This characterization allowed the study of flow and transport of HCH through numerical simulation using the Hydrus 1D software. The simulations had two different goals, the first was evaluated the simulation results compared to the current situation in the field. In a second step the sensitivity of transport due to the change of the parameters obtained experimentally Ks; Kd; s and (Van Genuchten); and parameters obtained from the literature. The results showed that the Hydrus 1D model simulates HCH contamination in soil. Water degradation parameter was essential to get orders of magnitude similar to those identified in field concentrations. The degradation, diffusivity, hydraulic conductivity and dispersivity parameters are those that most affect the final results of concentration of HCH in groundwater and therefore deserve more attention in future investigations.
2

Caracterização geoambiental e avaliação dos parâmetros que influenciam na mobilidade do HCH no meio poroso / Geoenvironmental characterization and assessment of parameters that influence the mobility of the HCH in porous medium.

Letícia dos Santos Macedo 17 October 2014 (has links)
Este trabalho apresenta a caracterização geoambiental de solos de uma área contaminada, localizada no município de Santo André, Estado de São Paulo, Brasil. O objetivo foi determinar parâmetros experimentais para permitir o estudo de alguns aspectos do transporte do pesticida organoclorado Hexaclorociclohexano (HCH). A área de estudo contém células com cerca de 30.000 toneladas de um material contendo HCH em elevadas concentrações. As investigações de campo demonstram que há concentrações de HCH na água subterrânea. Em 2011, foram coletadas amostras deformadas e indeformadas de solo em quatro diferentes pontos superficiais da área contaminada, e posteriormente uma amostra composta da camada de solo de alteração de rocha (SAR), a fim de responder a questionamentos quanto à mobilidade do contaminante na área. A caracterização geoambiental, baseada em ensaios laboratoriais, foi realizada por meio das seguintes análises: análise granulométrica, limites de Atterberg, densidade específica, porosidade, umidade do solo, curva de retenção de água no solo, condutividade hidráulica, ensaio de adsorção, pH, condutividade elétrica, capacidade de troca catiônica (CTC), teor de matéria orgânica e teor de voláteis. O solo superficial da área é heterogêneo e a capacidade de adsorção dos solos analisados foi menor do que o esperado. Esta caracterização subsidiou o estudo de fluxo e transporte do HCH, por meio de simulação numérica, utilizando o programa Hydrus 1D. As simulações tiveram dois objetivos diferentes: no primeiro foi avaliado os resultados da simulação em comparação à situação atual no campo; no segundo foi avaliada a sensibilidade do transporte em função da alteração dos parâmetros obtidos experimentalmente Ks; Kd; s e (Van Genuchten); e dos parâmetros obtidos na literatura. Os resultados permitiram concluir que o modelo Hydrus 1D consegue representar a contaminação do HCH no solo. O parâmetro de degradação na água foi essencial para chegar em ordens de grandeza de concentrações próximas das identificadas em campo. Os parâmetros de degradação, difusividade, dispersividade e condutividade hidráulica são os que mais afetam os resultados finais de concentração do HCH na água subterrânea e, portanto, merecem atenção maior durante as futuras investigações. / This paper presents the geoenvironmental characterization of soils from a contaminated site, located in Santo André, São Paulo State, Brazil. The objective was to determine experimental parameters to allow the study of some aspects of transport of the organochlorine pesticide hexachlorocyclohexane (HCH). The study site contains trenches with about 30,000 tons of a material containing high concentrations of HCH. The site investigations show that there are HCH concentrations in groundwater. In 2011, disturbed and undisturbed soil samples were collected at four different surface points of the contaminated site, and then a sample of soil from rock alteration layer (SAR) was also composed for characterization in order to answer questions concerning the mobility of contaminant in the site. The environmental characterization based on laboratory tests, was performed by the following analyzes: grain size distribution, Atterberg limits, specific gravity, porosity, moisture content, water retention curve, hydraulic conductivity, pH, electrical conductivity, cation exchange capacity (CEC), organic matter content and volatile content. The surface soil of the area is heterogeneous and the adsorption capacity of the soils analyzed were lower than expected. This characterization allowed the study of flow and transport of HCH through numerical simulation using the Hydrus 1D software. The simulations had two different goals, the first was evaluated the simulation results compared to the current situation in the field. In a second step the sensitivity of transport due to the change of the parameters obtained experimentally Ks; Kd; s and (Van Genuchten); and parameters obtained from the literature. The results showed that the Hydrus 1D model simulates HCH contamination in soil. Water degradation parameter was essential to get orders of magnitude similar to those identified in field concentrations. The degradation, diffusivity, hydraulic conductivity and dispersivity parameters are those that most affect the final results of concentration of HCH in groundwater and therefore deserve more attention in future investigations.
3

Desenvolvimento de um sistema para realização de ensaios sísmicos down-hole em conjunto com o CPT / Seismic testing down-hole in conjunction with CPT

Vitali, Osvaldo Paiva Magalhães 25 February 2011 (has links)
Quando ocorrem solicitações dinâmicas nos solos, torna-se indispensável a determinação do módulo de cisalhamento máximo (Go) para elaboração de projetos de Engenharia Geotécnica. Este parâmetro pode ser determinado a partir da velocidade de propagação das ondas S (Vs). Em campo, os ensaios mais empregadas para determinação de Vs são o cross-hole e o down-hole. O down-hole tem sido bastante empregado com a incorporação de geofones em ponteiras de piezocone. Esse ensaio tem se mostrado uma maneira rápida, econômica e muito confiável para determinação de Go, apresentando resultados consistentes com os obtidos no ensaio cross-hole. O objetivo deste trabalho é o desenvolvimento de um sistema para realização do ensaio sísmico down-hole e sua implantação. Inúmeros ensaios foram realizados no campus da Universidade Estadual Paulista, em Bauru/SP a fim de testar os procedimentos para execução do ensaio, os equipamentos utilizados e as técnicas de interpretação, onde se observou que a manutenção do eixo de vibração dos geofones paralelo a direção de aplicação do golpe foi o fator que mais influenciou na qualidade dos sinais. Para analisar a resposta dos geofones instalados na ponteira desenvolvida, realizaram-se ensaios em laboratório, onde se verificou que os geofones apresentavam resposta idêntica ao dos acelerômetro de referência. Por fim, foram realizados ensaios em três campos experimentais no interior do Estado de São Paulo, onde estão disponíveis resultados de ensaios cross-hole e ensaios down-hole realizados com equipamentos comerciais. Os resultados obtidos com o sistema desenvolvido nestes campos permitiram validar o sistema desenvolvido. / In the design stages of geotechnical engineering of a given project, it is imperative to ascertain the maximum shear modulus (Go) of those soils experiencing dynamic loads. One common method to determine Go is to measure shear wave velocity. Most field experiments are the cross-hole and down-hole tests to determine the velocity of shear waves. The downhole test has been widely used in conjunction with geophones placed behind the tip of piezocones. The down-hole test has proven to be a fast, economic, and very reliable method to determine Go, it has produced data consistent with results obtained in cross-hole tests. The objective of this work is to present a comprehensive system for the down-hole test, which includes its implementation, execution, and the interpretation of data collected. Several tests were performed at the campus of Universidade Estadual Paulista, UNESP, in Bauru, S.P. The objective of those experiments was to test the execution procedures and method of interpretation. It was observed the quality of the results obtained was chiefly dependent on maintaining the axis of vibration of the geophones parallel to the direction of application of the original blow. The analysis of the response by the geophones installed at the tip of the cone included experiments performed at the laboratory, where it was observed that the geophones responded identically to those accelerometers used as reference. Further, downhole experiments using system proposed here were performed in three experimental research sites of the state of São Paulo. The objective was to compare results to the data available in literature, which were obtained using commercial SCPT equipment and cross-hole tests. The down-hole testswere performed within the guidelines of the system proposed here and the results of the experiment served to corroborate the suitability of the developed system.
4

Desenvolvimento de um sistema para realização de ensaios sísmicos down-hole em conjunto com o CPT / Seismic testing down-hole in conjunction with CPT

Osvaldo Paiva Magalhães Vitali 25 February 2011 (has links)
Quando ocorrem solicitações dinâmicas nos solos, torna-se indispensável a determinação do módulo de cisalhamento máximo (Go) para elaboração de projetos de Engenharia Geotécnica. Este parâmetro pode ser determinado a partir da velocidade de propagação das ondas S (Vs). Em campo, os ensaios mais empregadas para determinação de Vs são o cross-hole e o down-hole. O down-hole tem sido bastante empregado com a incorporação de geofones em ponteiras de piezocone. Esse ensaio tem se mostrado uma maneira rápida, econômica e muito confiável para determinação de Go, apresentando resultados consistentes com os obtidos no ensaio cross-hole. O objetivo deste trabalho é o desenvolvimento de um sistema para realização do ensaio sísmico down-hole e sua implantação. Inúmeros ensaios foram realizados no campus da Universidade Estadual Paulista, em Bauru/SP a fim de testar os procedimentos para execução do ensaio, os equipamentos utilizados e as técnicas de interpretação, onde se observou que a manutenção do eixo de vibração dos geofones paralelo a direção de aplicação do golpe foi o fator que mais influenciou na qualidade dos sinais. Para analisar a resposta dos geofones instalados na ponteira desenvolvida, realizaram-se ensaios em laboratório, onde se verificou que os geofones apresentavam resposta idêntica ao dos acelerômetro de referência. Por fim, foram realizados ensaios em três campos experimentais no interior do Estado de São Paulo, onde estão disponíveis resultados de ensaios cross-hole e ensaios down-hole realizados com equipamentos comerciais. Os resultados obtidos com o sistema desenvolvido nestes campos permitiram validar o sistema desenvolvido. / In the design stages of geotechnical engineering of a given project, it is imperative to ascertain the maximum shear modulus (Go) of those soils experiencing dynamic loads. One common method to determine Go is to measure shear wave velocity. Most field experiments are the cross-hole and down-hole tests to determine the velocity of shear waves. The downhole test has been widely used in conjunction with geophones placed behind the tip of piezocones. The down-hole test has proven to be a fast, economic, and very reliable method to determine Go, it has produced data consistent with results obtained in cross-hole tests. The objective of this work is to present a comprehensive system for the down-hole test, which includes its implementation, execution, and the interpretation of data collected. Several tests were performed at the campus of Universidade Estadual Paulista, UNESP, in Bauru, S.P. The objective of those experiments was to test the execution procedures and method of interpretation. It was observed the quality of the results obtained was chiefly dependent on maintaining the axis of vibration of the geophones parallel to the direction of application of the original blow. The analysis of the response by the geophones installed at the tip of the cone included experiments performed at the laboratory, where it was observed that the geophones responded identically to those accelerometers used as reference. Further, downhole experiments using system proposed here were performed in three experimental research sites of the state of São Paulo. The objective was to compare results to the data available in literature, which were obtained using commercial SCPT equipment and cross-hole tests. The down-hole testswere performed within the guidelines of the system proposed here and the results of the experiment served to corroborate the suitability of the developed system.

Page generated in 0.1102 seconds