• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise da superfície de titânio sob ação do laser com e sem deposição de hidroxiapatita

Sisti, Karin Ellen [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T18:55:02Z : No. of bitstreams: 1 sisti_ke_me_araca.pdf: 3618905 bytes, checksum: 81667dd0274261a8682b5422aae8f08f (MD5) / Universidade Estadual Paulista (UNESP) / O longo tempo de espera entre a cirurgia e a instalação da prótese sobre implante dentário, sempre preocupou os pesquisadores. Proposição: Estudar a superfície de implantes utilizando discos de titânio irradiados com feixe de laser. Método: A amostra foi irradiada com feixes de laser de alta intensidade (Nd-YAG), posteriormente depositado hidróxiapatita e submetido a tratamento térmico. Foi analisada sob MEV (Microscópio Eletrônico de Varredura) e realizada análise morfológica qualitativa com microfotografias em vários aumentos. Resultados: A superfície irradiada com laser apresentou deformidade superficial e característica isomórfica; a aplicação de hidroxiapatita pelo método de biomimético aumentou quantitativamente a área da superfície de titânio; a amostra demonstrou características não encontradas nos implantes disposto no mercado. Conclusões: deposição de hidroxiapatita, melhor característica isomórfica e aumento quantitativo da área superficial estudada. / Background: Delay between surgery and dentistry prosthesis is the important factory to studier. Proposition: The aim of this study has been to analyze the surface of titanium implants in the odontology. Methods: Titanium discs were treated with laser high insensitive (Nd-YAG), and deposited hydroxyapatite with thermal treatment. Sample received Morphological analyze qualitative for micrographies with many size in SEM (Scanning Electron Microscopy). Results: Surface laser irradiation shows roughness and isomorphic characteristic. The hydroxyapatite amplified the titanium surface area by method bio mimetic. Sample shows characteristics don t have in the market. Conclusions: The treatment surface showed hydroxyapatite, good isomorphic characteristic, amplification the titanium surface area.
2

Análise microbiológica comparativa da ação de diferentes agentes descontaminantes sobre superfícies de titânio / Microbiological comparison of different decontaminant agents on rough and smooth titanium surfaces: microbiological analysis

Blagitz, Renata Rodrigues de Freitas 26 September 2011 (has links)
Os implantes de titânio estabeleceram-se, ao longo do tempo, como uma opção de tratamento com grande índice de sucesso. Entretanto, falhas são passíveis de ocorrer, devido à exposição de suas superfícies ao meio bucal, imediatamente ou até muito tempo passado de sua implantação. Estas superfícies de titânio podem se infectar por bactérias e seus produtos, de forma semelhante à que ocorre na superfície de raízes dentais. Tais contaminantes intensificam a resposta inflamatória, além de alterar a estrutura superficial do implante podendo dar origem às doenças peri-implantares, como a mucosite peri-implantar e a peri-implantite. Para o tratamento destas doenças, diversos métodos de descontaminação de superfícies de implantes têm sido propostos, incluindo o uso substâncias anti-sépticas, jatos abrasivos, ácidos, antibióticos e lasers. O objetivo foi avaliar comparativamente a capacidade de descontaminação do peróxido de hidrogênio a 1,5 % (H2O2), do gluconato de clorexidina a 0,12% (CLX) e do soro fisiológico (SF) já que, até o momento, nenhuma metodologia está estabelecida como padrão ouro para a limpeza superficial. Placa bacteriana foi colhida de sítios de doença periodontal crônica para contaminação de discos de titânio de superfícies lisas e rugosas. Posteriormente, os discos foram submersos em 10 mL das substâncias estudadas por 1 minuto, friccionados com swab e enxaguados em solução fisiológica. Discos controle (C) foram somente enxaguados em soro fisiológico. Desta forma resultaram os seguintes grupos de estudo, constituídos de 5 discos de cada tipo de superfície lisa (L) e rugosa (R): H2O2 R , CLXR, SFR, CR, H2O2L, CLXL , SFL e CL. A avaliação do potencial descontaminante das substâncias foi realizada através da quantificação do crescimento bacteriano pela contagem das unidades formadoras de colônia (UFCs) após semeadura em Agar-brucella e incubação em jarra de CO2 a 37oC por 24 horas. Os resultados após descontaminação foram comparados através da análise de variância a dois critérios (ANOVA) e o nível de significância adotado para todos os testes foi de 5%. Os resultados obtidos permitiram concluir que: as bactérias da periodontite crônica têm capacidade de contaminar e aderir aos discos de titânio nos dois tipos de superfícies estudados; as superfícies lisas e rugosas não diferem entre si quanto aos procedimentos de contaminação e de descontaminação propostos; a clorexidina, o peróxido de hidrogênio e o soro fisiológico apresentaram-se eficientes na descontaminação das superfícies de titânio contaminadas in vitro; houve ligeira superioridade na descontaminação pelo tratamento com a clorexidina de ambas as superfícies de titânio avaliadas. / Actually, the titanium implants are a successful option of treatment in Dentistry. However, failures are possible to occur due to surface exposition to oral environment immediately or lately after its implantation. The titanium implants surfaces can be infected by bacteria and its products similarly to dental roots surfaces. The contaminants turn the inflammatory response tissues more intensive and them alter the surface structure of the implant and cause periimplant diseases like mucositis and peri-implantitis. Several methods of treatment for those diseases have been proposed in the literature, including antiseptics rinses, abrasives air powder, acids, antibiotics and lasers. The aim of this work was to comparatively evaluate the potential for decontamination of the hydrogen peroxide at 1,5% (H2O2), the 0,12% chlorhexidine gluconate (CLX) and the saline solution (SF) as cleaning methods, once until this moment there is not a gold standard method established for this purpose. Bacterial plaque harvested from sites of chronic periodontal disease was used to contaminate smooth and rough surfaces of titanium. Subsequently, decontamination procedures were realized by submerging the discs in 10 ml of the studied substances for 1 minute, cleaned by rubbing with swab and washed on saline solution. Control discs (C) were only washed in saline solution. The following test groups composed by 5 discs of each surface, smooth (L) and rough (R):, were then originated: H2O2 R , CLXR, SFR, CR, H2O2L, CLXL , SFL and CL. The decontaminant potential of studied substances was realized by counting the colony forming units after seeding in Agar-brucella, under anaerobiosis condition for 24 hours under 37oC. The data analysis was made by Variance Analysis (ANOVA) at 5% of significance level. The results lead to the following conclusions: the chronic periodontal biofilm adhesion was possible on smooth and rough titanium surfaces; the surface characteristic had no significant influence on contamination and decontamination method, independently of the substance used; clorhexidine, hydrogen peroxide and saline solution were efficient on decontaminating both types of titanium surfaces in vitro with slightly superiority to clorhexidine.
3

Análise microbiológica comparativa da ação de diferentes agentes descontaminantes sobre superfícies de titânio / Microbiological comparison of different decontaminant agents on rough and smooth titanium surfaces: microbiological analysis

Renata Rodrigues de Freitas Blagitz 26 September 2011 (has links)
Os implantes de titânio estabeleceram-se, ao longo do tempo, como uma opção de tratamento com grande índice de sucesso. Entretanto, falhas são passíveis de ocorrer, devido à exposição de suas superfícies ao meio bucal, imediatamente ou até muito tempo passado de sua implantação. Estas superfícies de titânio podem se infectar por bactérias e seus produtos, de forma semelhante à que ocorre na superfície de raízes dentais. Tais contaminantes intensificam a resposta inflamatória, além de alterar a estrutura superficial do implante podendo dar origem às doenças peri-implantares, como a mucosite peri-implantar e a peri-implantite. Para o tratamento destas doenças, diversos métodos de descontaminação de superfícies de implantes têm sido propostos, incluindo o uso substâncias anti-sépticas, jatos abrasivos, ácidos, antibióticos e lasers. O objetivo foi avaliar comparativamente a capacidade de descontaminação do peróxido de hidrogênio a 1,5 % (H2O2), do gluconato de clorexidina a 0,12% (CLX) e do soro fisiológico (SF) já que, até o momento, nenhuma metodologia está estabelecida como padrão ouro para a limpeza superficial. Placa bacteriana foi colhida de sítios de doença periodontal crônica para contaminação de discos de titânio de superfícies lisas e rugosas. Posteriormente, os discos foram submersos em 10 mL das substâncias estudadas por 1 minuto, friccionados com swab e enxaguados em solução fisiológica. Discos controle (C) foram somente enxaguados em soro fisiológico. Desta forma resultaram os seguintes grupos de estudo, constituídos de 5 discos de cada tipo de superfície lisa (L) e rugosa (R): H2O2 R , CLXR, SFR, CR, H2O2L, CLXL , SFL e CL. A avaliação do potencial descontaminante das substâncias foi realizada através da quantificação do crescimento bacteriano pela contagem das unidades formadoras de colônia (UFCs) após semeadura em Agar-brucella e incubação em jarra de CO2 a 37oC por 24 horas. Os resultados após descontaminação foram comparados através da análise de variância a dois critérios (ANOVA) e o nível de significância adotado para todos os testes foi de 5%. Os resultados obtidos permitiram concluir que: as bactérias da periodontite crônica têm capacidade de contaminar e aderir aos discos de titânio nos dois tipos de superfícies estudados; as superfícies lisas e rugosas não diferem entre si quanto aos procedimentos de contaminação e de descontaminação propostos; a clorexidina, o peróxido de hidrogênio e o soro fisiológico apresentaram-se eficientes na descontaminação das superfícies de titânio contaminadas in vitro; houve ligeira superioridade na descontaminação pelo tratamento com a clorexidina de ambas as superfícies de titânio avaliadas. / Actually, the titanium implants are a successful option of treatment in Dentistry. However, failures are possible to occur due to surface exposition to oral environment immediately or lately after its implantation. The titanium implants surfaces can be infected by bacteria and its products similarly to dental roots surfaces. The contaminants turn the inflammatory response tissues more intensive and them alter the surface structure of the implant and cause periimplant diseases like mucositis and peri-implantitis. Several methods of treatment for those diseases have been proposed in the literature, including antiseptics rinses, abrasives air powder, acids, antibiotics and lasers. The aim of this work was to comparatively evaluate the potential for decontamination of the hydrogen peroxide at 1,5% (H2O2), the 0,12% chlorhexidine gluconate (CLX) and the saline solution (SF) as cleaning methods, once until this moment there is not a gold standard method established for this purpose. Bacterial plaque harvested from sites of chronic periodontal disease was used to contaminate smooth and rough surfaces of titanium. Subsequently, decontamination procedures were realized by submerging the discs in 10 ml of the studied substances for 1 minute, cleaned by rubbing with swab and washed on saline solution. Control discs (C) were only washed in saline solution. The following test groups composed by 5 discs of each surface, smooth (L) and rough (R):, were then originated: H2O2 R , CLXR, SFR, CR, H2O2L, CLXL , SFL and CL. The decontaminant potential of studied substances was realized by counting the colony forming units after seeding in Agar-brucella, under anaerobiosis condition for 24 hours under 37oC. The data analysis was made by Variance Analysis (ANOVA) at 5% of significance level. The results lead to the following conclusions: the chronic periodontal biofilm adhesion was possible on smooth and rough titanium surfaces; the surface characteristic had no significant influence on contamination and decontamination method, independently of the substance used; clorhexidine, hydrogen peroxide and saline solution were efficient on decontaminating both types of titanium surfaces in vitro with slightly superiority to clorhexidine.

Page generated in 0.0674 seconds