• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo experimental da refração não linear em vapor de césio utilizando a técnica z-scan

Silva Júnior, Valdeci Mestre da 13 October 2011 (has links)
Made available in DSpace on 2015-05-14T12:14:02Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 4030478 bytes, checksum: 03b24ba7a8957d1ad2df45e0035eccad (MD5) Previous issue date: 2011-10-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The z-scan technique consists in measurement of the variation of the radial intensity of a Gaussian laser beam induced by self-focusing or self-defocusing while propagating through a nonlinear medium. These variations are deduced through detection of the beam transmitted through a small, fixed aperture. After the seminal work by Sheik-Bahae et al. [30] in 1990, a lot of work has been done studying the nonlinearity of solids. By comparison, very little has been done with resonant atomic vapors, but rich results were obtained due to the very high atomic susceptibilities at resonance [33, 42]. In this work we report our measurements using a focused laser beam sent through a thermal cesium vapor. We have carried out many runs of z-scan for different frequencies of the laser tuned in the wings of the cesium Doppler-broadened D2 transition (6S1/2-6P3/2 at 852 nm) and observed the changes in the radiation transmitted through a fixed aperture. / A técnica de z-scan (varredura z) consiste na medição da variação da intensidade de um feixe laser Gaussiano induzida por auto-focalização ou auto-desfocalização quando o feixe se propaga através de um meio não-linear. Estas variações são medidas através da detecção do feixe transmitido por uma abertura pequena, fixa. Após o trabalho seminal de Sheik-Bahae e outros [30] em 1990, muitos trabalhos foram feitos estudando a não-linearidade de sólidos com esta técnica. Por comparação, muito pouco tem sido feito com vapores atômicos ressonantes, mas resultados ricos foram obtidos devido às susceptibilidades atômicas muito elevadas na ressonância [33,42]. Neste trabalho relatamos nossas medições utilizando um feixe laser focalizado enviado através de um vapor térmico de césio. Nós realizamos muitas varreduras z para diferentes freqüências do laser nas asas da transição D2 com alargamento Doppler do césio (6S1/2 6P3/2 em 852 nanômetros) e observamos as mudanças na radiação transmitida através de uma abertura fixa.
2

Novos resultados teóricos e experimentais para a técnica Z-scan / Novel theoretical and experimental results to Z-scan technique

Chaves, Anderson Silva 30 June 2010 (has links)
O índice de refração não-linear n2 é o parâmetro chave da não-linearidade de terceira ordem em materiais ópticos. Um método simples, direto e sensível para medição do índice de refração não-linear (n2) é a técnica Z-scan proposta Sheik-Bahae et al 1. Nesse trabalho, um estudo sistemático quanto a esta técnica foi realizado. Utilizando a integral de difração de Fresnel-Kirchhoff, foi possível analisar a técnica investigando a influência do raio de abertura da íris. Foram obtidas expressões analíticas inéditas quando consideramos baixas não-linearidades induzidas por amostras finas. Esses resultados mostraram que o valor de n2 obtido é aproximadamente 36% maior do que n2 obtido por Sheik-Bahae para abertura linear de S=0,5, por exemplo.Extensões da técnica foram feitas, onde simulações para testar a viabilidade de medidas Z-scan no campo próximo e com dois feixes foram realizadas, de onde também foi possível encontrar resultados analíticos inéditos. Esses resultados teóricos foram testados tanto para feixe único quanto duplo em alguns experimentos, sendo obtido um bom acordo. Por fim, um novo método para medição do índice de refração não-linear não-degenerado foi proposto, em que é possível obter n2 no comprimento de onda do feixe de prova, num experimento com dois feixes. Esse resultado é importante uma vez que, em muitos casos, não é possível a realização de uma medida Z-scan convencional, devido ao fato da amostra não absorver o comprimento de onda do feixe de prova. Um resultado de n2 para rubi em 633nm foi obtido em bom acordo com resultados prévios da literatura, em que foram utilizadas técnicas de maior complexidade experimental. / The nonlinear refractive index n2 is the key parameter of the third order nonlinearity of optical materials. A simple, direct and sensitive measurement of nonlinear refractive index n2 is so-called Z-scan technique proposed by Sheik Bahae et al 1. In this work, a systematic study on this technique was performed. Based on Fresnel-Kirchhoff diffraction integral formula, it was possible to analyze the technique in order to investigate the influence of the apertures radius. We obtained unpublished analytical expressions when we consider small nonlinearities induced by thin samples. These results showed that the value of n2 obtained is about 36% larger than n2 obtained by Sheik-Bahae when the linear opening is 50%, for example.Extensions about the technique were made. Simulations were performed in order to test the feasibility of near-field Z-scan and two-color Z-scan measurements. Again it was also possible to find unpublished analytical results. The theoretical results were tested in some experiments and good agreement was found. Finally, a new method for measuring the nondegenerate refractive index was proposed. So, there is the possibility to obtain n2 at the wavelength of the probe beam in a two-color Z-scan experiment. This result is important since in many cases is impossible to perform a conventional z-scan measurement, due to the fact that the sample does not absorb the wavelength of the probe beam. A result of n2 for ruby at 633nm was obtained in good agreement with previous studies.
3

Novos resultados teóricos e experimentais para a técnica Z-scan / Novel theoretical and experimental results to Z-scan technique

Anderson Silva Chaves 30 June 2010 (has links)
O índice de refração não-linear n2 é o parâmetro chave da não-linearidade de terceira ordem em materiais ópticos. Um método simples, direto e sensível para medição do índice de refração não-linear (n2) é a técnica Z-scan proposta Sheik-Bahae et al 1. Nesse trabalho, um estudo sistemático quanto a esta técnica foi realizado. Utilizando a integral de difração de Fresnel-Kirchhoff, foi possível analisar a técnica investigando a influência do raio de abertura da íris. Foram obtidas expressões analíticas inéditas quando consideramos baixas não-linearidades induzidas por amostras finas. Esses resultados mostraram que o valor de n2 obtido é aproximadamente 36% maior do que n2 obtido por Sheik-Bahae para abertura linear de S=0,5, por exemplo.Extensões da técnica foram feitas, onde simulações para testar a viabilidade de medidas Z-scan no campo próximo e com dois feixes foram realizadas, de onde também foi possível encontrar resultados analíticos inéditos. Esses resultados teóricos foram testados tanto para feixe único quanto duplo em alguns experimentos, sendo obtido um bom acordo. Por fim, um novo método para medição do índice de refração não-linear não-degenerado foi proposto, em que é possível obter n2 no comprimento de onda do feixe de prova, num experimento com dois feixes. Esse resultado é importante uma vez que, em muitos casos, não é possível a realização de uma medida Z-scan convencional, devido ao fato da amostra não absorver o comprimento de onda do feixe de prova. Um resultado de n2 para rubi em 633nm foi obtido em bom acordo com resultados prévios da literatura, em que foram utilizadas técnicas de maior complexidade experimental. / The nonlinear refractive index n2 is the key parameter of the third order nonlinearity of optical materials. A simple, direct and sensitive measurement of nonlinear refractive index n2 is so-called Z-scan technique proposed by Sheik Bahae et al 1. In this work, a systematic study on this technique was performed. Based on Fresnel-Kirchhoff diffraction integral formula, it was possible to analyze the technique in order to investigate the influence of the apertures radius. We obtained unpublished analytical expressions when we consider small nonlinearities induced by thin samples. These results showed that the value of n2 obtained is about 36% larger than n2 obtained by Sheik-Bahae when the linear opening is 50%, for example.Extensions about the technique were made. Simulations were performed in order to test the feasibility of near-field Z-scan and two-color Z-scan measurements. Again it was also possible to find unpublished analytical results. The theoretical results were tested in some experiments and good agreement was found. Finally, a new method for measuring the nondegenerate refractive index was proposed. So, there is the possibility to obtain n2 at the wavelength of the probe beam in a two-color Z-scan experiment. This result is important since in many cases is impossible to perform a conventional z-scan measurement, due to the fact that the sample does not absorb the wavelength of the probe beam. A result of n2 for ruby at 633nm was obtained in good agreement with previous studies.

Page generated in 0.0373 seconds