• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The suitability of estrogen and androgen bioassays for the measurement of endocrine activity in different water matrices

Ngcobo, Silindile January 2017 (has links)
Endocrine disrupting chemicals (EDCs) are ubiquitous in the environment and their presence in water bodies is documented. They discharge into surface water (SW) unmonitored, posing a threat to both aquatic and terrestrial lives. This is a challenge as not all populations have access to treated drinking water (TDW). The EDC contaminated serves as a route of exposure, together with ineffective treatment plants. Given the complexity of the endocrine system, EDCs may mimic or antagonise natural hormones or disrupt their synthesis, metabolism and excretion. The associated health effects include testicular dysgenesis syndrome, metabolic disorders and cancers. Policy and internationally standardised test methods are however sti ll limited. This study therefore aimed to assess the suitability of two assays used for screening estrogenic activity and one for androgenic activity in different water sources. The study consisted of two phases. In phase 1, water sample (tap, surface and treated wastewater) were collected from a catchment area in Pretoria. The samples and a spiked MilliQ laboratory water sample were extracted with solid phase extraction (SPE) and sent to Germany for distribution to participating laboratories. Samples (n=24) from six different countries were received to test for androgenic activity in the MDA-kb2 reporter gene assay. In phase 2, SW and TDW samples were collected from April 2015 until March 2016. The samples were filtered, extracted using SPE and assayed with the YES assay, T47D-KBluc reporter gene assay for estrogenic activity and MDA-kb2 reporter gene assay for androgenic activity. In phase 1, androgenic activity was detected in 4 out of 24 (21%) samples and ranged from 0.23 ± 0.040 ng/L to 0.008 ± 0.001 ng/L DHTEqs. In phase 2, estrogenic activity was detected in 16 out of 24 (67%) SW samples in the T47DKBluc reporter gene assay and ranged from 0.31 ± 0.05 pg/L to 10.51 ± 5.74 pg/L EEqs. It was below the detection limit (dl) in the YES assay. Androgenic activity was detected in 4 out of 24 (17%) SW samples, ranging from 0.0033 ± 0.0050 ng/L to 0.090 ± 0.040 ng/L DHTEqs. Androgenic and estrogenic activity was higher i n pretreatment samples compared to post-treatment in both treatment plants. In phase 1, the MDA-kb2 reporter gene assay was successfully applied to water samples from different sources. Androgenic activity was highest in treated wastewater. In phase 2, treatment plants proved to be effective in removing estrogens detected in the SW samples, as the TDW samples were below the dl. Estrogenic activity is within the ranges reported in other studies. Positive samples were below the 0.7 ng/L proposed trigger value for health risk assessments. Detected androgenic activity was lower in TDW samples compared to the SW samples supplying the two treatment plants indicating that they were both effective in removing the androgenic activity detected. Few studies have reported androgenic activity in tap water. This study strengthens the argument for using a battery of assays when monitoring endocrine activity as EDCs occur at low concentrations in mixtures. / Dissertation (MSc)--University of Pretoria, 2017. / School of Health Systems and Public Health (SHSPH) / MSc / Unrestricted

Page generated in 0.3759 seconds