181 |
The design, fabrication, characterization, and modeling of a novel semiconductor device : the metal oxide semiconductor bipolar junction transistorOkada, David N January 1986 (has links)
Typescript. / Thesis (Ph. D.)--University of Hawaii at Manoa, 1986. / Bibliography: leaves 308-310. / Photocopy. / xxix, 310 leaves, bound ill. 29 cm
|
182 |
Single-electron transistors for detection of charge motion in the solid stateBrenner, Rolf, Physics, Faculty of Science, UNSW January 2004 (has links)
This work investigates advanced single-electron transistor (SET) devices for detection of charge motion in solid-state systems. In particular, novel, nanoscale twin-SET and double-island SET (DISET) detectors are introduced as sensitive charge detectors. Some advantages over conventional SET detectors in terms of noise performance, sensitivity and versatility are pointed out. With the prospect of present, transistor-based microelectronics facing serious limitations due to quantum effects and heat dissipation, alternative computing paradigms ??? such as quantum computers, quantum-dot cellular automata and single-electronics ??? have emerged, promising an extension of highlevel integration and computing power beyond the above limitations. The most promising proposals are based on solid-state systems, and readout of a computational result often requires ultra-sensitive charge detectors capable of sensing the motion of single charges on fast timescales. SETs have been shown to combine all these qualities. However, random fluctuations of the background charge in solid-state systems can affect SETs and cause errors during readout. A twin-SET detector is presented that consists of two independent SETs, which were used to detect controlled single electron transfers on a small, floating metal double-dot. By cross-correlating the two SET signals, rejection of random charge noise is successfully demonstrated, thus decreasing the error probability during readout. Detection of single-electron transfer in a double-dot is also demonstrated using a double-island SET. In addition, conductance suppression in this novel DISET detector allows the detection of electrostatically degenerate charge con- figurations of a double-dot, which cannot be achieved with single-island SETs. We consider the noise performance of the DISET, and an intuitive definition of the DISET charge sensitivity suggests that under certain conditions, DISETs can have a better charge sensitivity than conventional SETs, which would be attractive for quantum limited measurements. Finally we present the first study of a DISET operated at radio-frequencies (rf-DISET), compatible with charge detection on ms timescales. This capability is a prerequisite when reading out the charge state of quantum mechanical systems. A very good charge sensitivity (5.6 x 10i6 e/pHz) and noise temperature (2.1 K) of the rf-DISET setup are reported.
|
183 |
Single-electron transistors for detection of charge motion in the solid stateBrenner, Rolf, Physics, Faculty of Science, UNSW January 2004 (has links)
This work investigates advanced single-electron transistor (SET) devices for detection of charge motion in solid-state systems. In particular, novel, nanoscale twin-SET and double-island SET (DISET) detectors are introduced as sensitive charge detectors. Some advantages over conventional SET detectors in terms of noise performance, sensitivity and versatility are pointed out. With the prospect of present, transistor-based microelectronics facing serious limitations due to quantum effects and heat dissipation, alternative computing paradigms ??? such as quantum computers, quantum-dot cellular automata and single-electronics ??? have emerged, promising an extension of highlevel integration and computing power beyond the above limitations. The most promising proposals are based on solid-state systems, and readout of a computational result often requires ultra-sensitive charge detectors capable of sensing the motion of single charges on fast timescales. SETs have been shown to combine all these qualities. However, random fluctuations of the background charge in solid-state systems can affect SETs and cause errors during readout. A twin-SET detector is presented that consists of two independent SETs, which were used to detect controlled single electron transfers on a small, floating metal double-dot. By cross-correlating the two SET signals, rejection of random charge noise is successfully demonstrated, thus decreasing the error probability during readout. Detection of single-electron transfer in a double-dot is also demonstrated using a double-island SET. In addition, conductance suppression in this novel DISET detector allows the detection of electrostatically degenerate charge con- figurations of a double-dot, which cannot be achieved with single-island SETs. We consider the noise performance of the DISET, and an intuitive definition of the DISET charge sensitivity suggests that under certain conditions, DISETs can have a better charge sensitivity than conventional SETs, which would be attractive for quantum limited measurements. Finally we present the first study of a DISET operated at radio-frequencies (rf-DISET), compatible with charge detection on ms timescales. This capability is a prerequisite when reading out the charge state of quantum mechanical systems. A very good charge sensitivity (5.6 x 10i6 e/pHz) and noise temperature (2.1 K) of the rf-DISET setup are reported.
|
184 |
Single-electron transistors for detection of charge motion in the solid stateBrenner, Rolf, Physics, Faculty of Science, UNSW January 2004 (has links)
This work investigates advanced single-electron transistor (SET) devices for detection of charge motion in solid-state systems. In particular, novel, nanoscale twin-SET and double-island SET (DISET) detectors are introduced as sensitive charge detectors. Some advantages over conventional SET detectors in terms of noise performance, sensitivity and versatility are pointed out. With the prospect of present, transistor-based microelectronics facing serious limitations due to quantum effects and heat dissipation, alternative computing paradigms ??? such as quantum computers, quantum-dot cellular automata and single-electronics ??? have emerged, promising an extension of highlevel integration and computing power beyond the above limitations. The most promising proposals are based on solid-state systems, and readout of a computational result often requires ultra-sensitive charge detectors capable of sensing the motion of single charges on fast timescales. SETs have been shown to combine all these qualities. However, random fluctuations of the background charge in solid-state systems can affect SETs and cause errors during readout. A twin-SET detector is presented that consists of two independent SETs, which were used to detect controlled single electron transfers on a small, floating metal double-dot. By cross-correlating the two SET signals, rejection of random charge noise is successfully demonstrated, thus decreasing the error probability during readout. Detection of single-electron transfer in a double-dot is also demonstrated using a double-island SET. In addition, conductance suppression in this novel DISET detector allows the detection of electrostatically degenerate charge con- figurations of a double-dot, which cannot be achieved with single-island SETs. We consider the noise performance of the DISET, and an intuitive definition of the DISET charge sensitivity suggests that under certain conditions, DISETs can have a better charge sensitivity than conventional SETs, which would be attractive for quantum limited measurements. Finally we present the first study of a DISET operated at radio-frequencies (rf-DISET), compatible with charge detection on ms timescales. This capability is a prerequisite when reading out the charge state of quantum mechanical systems. A very good charge sensitivity (5.6 x 10i6 e/pHz) and noise temperature (2.1 K) of the rf-DISET setup are reported.
|
185 |
Single-electron transistors for detection of charge motion in the solid stateBrenner, Rolf, Physics, Faculty of Science, UNSW January 2004 (has links)
This work investigates advanced single-electron transistor (SET) devices for detection of charge motion in solid-state systems. In particular, novel, nanoscale twin-SET and double-island SET (DISET) detectors are introduced as sensitive charge detectors. Some advantages over conventional SET detectors in terms of noise performance, sensitivity and versatility are pointed out. With the prospect of present, transistor-based microelectronics facing serious limitations due to quantum effects and heat dissipation, alternative computing paradigms ??? such as quantum computers, quantum-dot cellular automata and single-electronics ??? have emerged, promising an extension of highlevel integration and computing power beyond the above limitations. The most promising proposals are based on solid-state systems, and readout of a computational result often requires ultra-sensitive charge detectors capable of sensing the motion of single charges on fast timescales. SETs have been shown to combine all these qualities. However, random fluctuations of the background charge in solid-state systems can affect SETs and cause errors during readout. A twin-SET detector is presented that consists of two independent SETs, which were used to detect controlled single electron transfers on a small, floating metal double-dot. By cross-correlating the two SET signals, rejection of random charge noise is successfully demonstrated, thus decreasing the error probability during readout. Detection of single-electron transfer in a double-dot is also demonstrated using a double-island SET. In addition, conductance suppression in this novel DISET detector allows the detection of electrostatically degenerate charge con- figurations of a double-dot, which cannot be achieved with single-island SETs. We consider the noise performance of the DISET, and an intuitive definition of the DISET charge sensitivity suggests that under certain conditions, DISETs can have a better charge sensitivity than conventional SETs, which would be attractive for quantum limited measurements. Finally we present the first study of a DISET operated at radio-frequencies (rf-DISET), compatible with charge detection on ms timescales. This capability is a prerequisite when reading out the charge state of quantum mechanical systems. A very good charge sensitivity (5.6 x 10i6 e/pHz) and noise temperature (2.1 K) of the rf-DISET setup are reported.
|
186 |
Analysis techniques for nanometer digital integrated circuitsRamalingam, Anand, January 1900 (has links)
Thesis (Ph. D.)--University of Texas at Austin, 2007. / Vita. Includes bibliographical references.
|
187 |
Development of a statistical model for NPN bipolar transistor mismatchLamontagne, Maurice. January 2007 (has links)
Thesis (M.S.) -- Worcester Polytechnic Institute. / Keywords: statistical model; mismatch; bipolar transistor. Includes bibliographical references (p.29).
|
188 |
Charge transport in polymer semiconductorsBasu, Debarshi, January 1900 (has links)
Thesis (Ph. D.)--University of Texas at Austin, 2007. / Vita. Includes bibliographical references.
|
189 |
Improved RF noise modeling for silicon-germanium heterojunction bipolar transistorsXia, Kejun Niu, Guofu. January 2006 (has links) (PDF)
Dissertation (Ph.D.)--Auburn University, 2006. / Abstract. Vita. Includes bibliographic references.
|
190 |
Single-electron transistors for detection of charge motion in the solid state /Brenner, Rolf. January 2004 (has links)
Thesis (Ph. D.)--University of New South Wales, 2004. / Also available online.
|
Page generated in 0.0257 seconds