• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Commande tolérante aux défauts des systèmes non linéaires représentés par des modèles de Takagi-Sugeno / Fault tolerant control for Takagi-Sugeno nonlinear systems

Bezzaoucha, Souad 25 October 2013 (has links)
Cette thèse porte sur la représentation T-S des systèmes non linéaires et les non-linéarités qui leur sont associées (saturation et paramètres variants dans le temps) pour la commande et le diagnostic. Ainsi, une nouvelle approche utilisant la transformation par secteurs non linéaires permet de ré-écrire le système sous forme polytopique en prenant en compte la présence de paramètres variants dans le temps. Cette forme polytopique est ensuite utile pour la synthèse d'observateurs assurant l'estimation simultanée de l'état et des paramètres du système. Une application au diagnostic est également considérée en comparant les valeurs des paramètres estimés en ligne avec leurs valeurs nominales supposées connues et représentatives du mode de fonctionnement non défaillant. Concernant la commande, la contrainte de saturation est représentée sous forme de modèle T-S et est intégrée au modèle du système. La synthèse de plusieurs lois de commande assurant la stabilité du système bouclé, en prenant en compte les limites de saturation est proposée. La poursuite de modèle de référence est également traitée avec la mise en évidence des conditions structurelles de poursuite pour les modèles non linéaires sous forme T-S. L'accent est mis sur les différents critères de choix de commande en fonction des buts recherchés / A first contribution of this thesis is to propose a systematic procedure to deal with the state and parameter estimation for nonlinear time-varying systems. It consists in transforming the original system into a T-S model with unmeasurable premise variables using the sector nonlinearity transformation. Then a joint state and parameter observer is designed and the convergence conditions of the joint state and parameter estimation errors are established. The second contribution of this thesis is the stabilization problem under saturation constraints. In fact, we aim to present a new approach for the saturation nonlinearity study, where the sector nonlinearity transformation is used to represent the nonlinear behaviour of a saturated actuator under a T-S form. The T-S representation of the saturation is used to integrate the limitation constraints into the control synthesis, such that the system stability is ensured and the controller gains are calculated according to the saturation level. The model reference tracking control problem is also addressed. It aims to highlight the encoutered difficulties and the proposed solutions to achieve the tracking objective. Through analytical studies, by presenting clear structural conditions and control strategies, we try to point and answer some major interogations, that are : "how the model reference is to be chosen ? " and "which tracking criterion to consider to achieve a certain objective ? ". The case of constrained control input is also considered with a special focus on the anticipation for the saturated control
2

Estimation et diagnostic de systèmes non linéaires décrits par un modèle de Takagi-Sugeno / Estimation and diagnosis of non linear systems described by Takagi-Sugeno models

Ichalal, Dalil 24 November 2009 (has links)
Cette thèse traite le problème de l'estimation d'état, du diagnostic et de commande tolérante aux défauts des systèmes non linéaires représentés par un modèle de Takagi-Sugeno (T-S) à variables de prémisse non mesurables. De nombreux algorithmes pour la synthèse d'observateurs robustes vis-à-vis des perturbations, des imperfections de modélisation et des entrées inconnues sont présentés en se basant sur quatre types d'observateurs : les observateursproportionnels, les observateurs à entrées inconnues, les observateurs proportionnel intégral (PI) et multi-intégral (PMI). Par la suite, ces derniers sont utilisés pour le diagnostic de fautes affectant des systèmes non linéaires. Ceci est réalisé au moyen de trois stratégies. La première utilise l'observateur à entrée inconnue par découplage afin de rendre l'observateur insensible à certains défauts et permettre de détecter et d'isoler les défauts en construisant des bancs d'observateurs. En raison des conditions structurelles souvent insatisfaites, le découplage total des défauts de l'erreur d'estimation d'état n'est pas réalisable. Afin de s'affranchir de ces contraintes, la seconde stratégie utilise les observateurs PI et PMI pour estimer simultanément l'état et les défauts du système. La troisième stratégie qui utilise le formalisme H8 vise à concevoir un générateur de résidus minimisant l'influence des perturbations et maximisant l'influence des défauts. Un choix adéquat des paramètres du générateur de résidus permet la détection, la localisation et l'estimation des défauts. Enfin, une loi de commande tolérante aux défauts par poursuite de trajectoire d'un modèle de référence estproposée en exploitant les observateurs PI et PMI / This thesis deals with state estimation, fault diagnosis and fault tolerant control of nonlinear systems represented by a Takagi-Sugeno model with unmeasurable premise variables. The problem of state estimation of nonlinear systems with T-S model with unmeasurable premise variable is explored. Algorithms for robust observers synthesis with respect to perturbations, modeling uncertainties and unknown inputs are afterward presented. These algorithms are based on four kinds of observers called proportional, unknown input observers (UIOs), proportional-integral (PI) and multiple-integral (PMI) . The application on model-based diagnosis is studied based on three strategies. The first one uses unknown input observer to decouple some faults and makes the observers insensitive to certain faults. This allows to detect and isolate faults by constructing observers banks. Due to strong structural conditions on designing UIOs decoupling the faults on the state estimation error is not possible. To avoid this problem, the second strategy uses PI and PMI observers in order to estimate simultaneously the state and the faults of the system. The third strategy uses the H8 formalism. This aims to minimize the influence of perturbations and to maximize the effects of faults on the residual signal. An adequate choice of the residual generator parameters allows to detect, to isolate and to estimate the faults affecting the system. Lastly, a fault tolerant control law is proposed by reference trajectory tracking based on the use of PI and PMI observers
3

Contribution à l'étude de la stabilité et à la stabilisation des réseaux DC à récupération d'énergie / Contribution to the stability analysis and stabilization of DC microgrid with energy storage capability

Magne, Pierre 30 April 2012 (has links)
Ce mémoire est consacré à l'étude du phénomène d'instabilité pouvant apparaître sur les bus continus des réseaux DC. En effet, l'interaction entre les différents sous-systèmes électriques (source, charge, filtre) composant le réseau DC peut conduire, sous certaines conditions, à l'instabilité du système. A partir de la modélisation des charges sous forme de "Charge à Puissance Constante" (notée CPL), des méthodes d'études permettant l'analyse de la stabilité "petit-signal" et "grand-signal" des systèmes électriques sont présentées. Celles-ci permettent de mettre en évidence le fait qu'un réseau DC ne peut pas fournir n'importe quelle puissance à ses charges sans devenir instable. Ces puissances limites dépendent à la fois de la structure du réseau et des valeurs de ses éléments passifs et de sa tension de bus. Afin de pouvoir augmenter l'amortissement/les marges de stabilité du système, des méthodes de stabilisation sont présentées dans ce mémoire. Elles proposent d'adapter les commandes des charges de manière à assurer sa stabilité. Ceci se fait grâce à l'addition d'un signal stabilisant sur la référence de chaque charge. Ce signal n'est visible que durant les régimes transitoires de la charge afin de ne pas modifier le point de fonctionnement demandé. Néanmoins, plus on voudra stabiliser une charge et plus son signal stabilisant sera important. Un bon compromis doit donc être trouvé afin d'assurer la stabilité du système sans altérer les performances dynamiques des charges. Deux approches différentes sont proposées afin de générer ces commandes stabilisantes. La première se base sur la mise en place d'un stabilisateur centralisé. Deux méthodes centralisées sont alors proposées : la première s'appuie sur la théorie des multimodèles de Takagi-Sugeno alors que la seconde s'appuie sur la théorie de Lyapunov. Cette dernière permettra d'orienter les efforts de stabilisation sur les charges souhaitées pour par exemple, les diriger principalement vers les organes de récupération d'énergie. La seconde approche se base sur la mise en place d'un système de stabilisation multi-agent. Celui-ci présente une structure décentralisée où chaque agent correspond à un bloc de stabilisation. Ceux-ci vont compenser localement les impacts déstabilisants de leur charge respective et leurs actions combinées permettront d'assurer la stabilité du système. De plus, on propose d'utiliser un algorithme d'optimisation sous contraintes qui permettra de donner un dimensionnement du système minimisant les efforts de stabilisation tout en considérant des cas de défaut tels que la perte de l'un des agents ou la reconfiguration du réseau / This thesis is devoted to the analysis of the instability phenomenon that may appear on the DC bus of DC microgrids. Indeed, interaction between the different electrical subsystems of the grid (source, load, filters) can lead, under certain conditions, to the system instability. From the "Constant Power Load" (CPL) hypothesis for the loads, this thesis presents studying methods for "small-signal" and "large-signal" stability analysis of electrical systems. This highlights that a DC microgrid cannot power the loads more than a maximum limit without becoming unstable. This power limitation depends on the structure of the grid, the value of its passive components, and its bus voltage. In order to improve the microgrid stability, stabilization methods are presented in this thesis. They propose to adapt the loads control to ensure the system stability. This is achieved by the addition of a stabilizing signal to the reference of each load. This signal is only visible during the load power transient mode to not change the requested operating point. However, a good trade-off must be found to ensure system stability without affecting the dynamic performance of its loads. Two approaches are investigated to generate the stabilizing commands. The first one is based on the establishment of a centralized stabilization block. Two centralized methods have been developed: the first one is based on the Takagi-Sugeno theory while the second is based on the Lyapunov theory. This latest permits to guide the stabilizing effort on the desired loads. For example, stabilizing effort can be oriented on the energy storage device. The second approach is based on the establishment of a multi-agent stabilizing system. It consists of a decentralized structure in which each agent corresponds to a stabilization block. These will locally compensate the destabilizing impact of their respective load on the microgrid, and their combined actions ensure the system stability. To design the system, the use of a constrained optimization algorithm is proposed. This permits to minimize stabilization efforts while considering faulty events such as the failure of one of the agents or a reconfiguration of the microgrid

Page generated in 0.1357 seconds