1 |
Analysis of Radiation Effect from Fire of Fuel TankLin, Mu-Shiung 12 July 2000 (has links)
None
|
2 |
Boilover in liquid hydrocarbon tank firesBuang, Azizul January 2014 (has links)
Boilover is a violent ejection of certain liquid hydrocarbons due to prolonged burning during a storage tank fire. It happens due to vaporization of the water sub-layer that commonly resides at the base of a storage tank, resulting in the ejection of hot fuel from the tank, enormous fire enlargement, formation of a fireball and an extensive ground fire. Boilover is a very dangerous accidental phenomenon, which can lead to serious injuries especially to emergency responders. The boilover can occur several hours after the fuel in a storage tank caught fire. The delayed boilover occurrence is an unknown strong parameter when managing the emergency response operations. Modelling and simulation of the boilover phenomenon will allow the prediction of the important characteristics features of such an event and enable corresponding safety measures to be prepared. Of particular importance is the time from ignition to the occurrence of boilover. In order to establish a tool for the prediction of the boilover events, it is essential to understand what happens within the fuel during a fire. Such understanding is important in order to recognize and determine the mechanisms for the hot zone formation and growth which are essentials, especially for predicting the onset time of boilover. Accordingly, boilover experiments and tests were planned and carried out at field scale by the Large Atmospheric Storage Tank FIRE (LASTFIRE) project with the intentions to evaluate the nature and consequences of a boilover, and to establish a common mechanism that would explain the boilover occurrence. Undertaking field scale experiments, however, is difficult to carry out so often due to high costs and high safety concerns. In order to obtain more detailed measurements and visual records of the behaviour of the liquids in the pool, a novel laboratory scale rig has been designed, built and commissioned at Loughborough University. The vessels used in the field scale tests and the laboratory scale rig were instrumented with a network of thermocouples, in order to monitor the distribution in temperature throughout the liquid and its variation with time. The temperature distribution variation as a function of time enabled the recognition of the phases of the evolution of the hot zone and hence the mechanism of boilover. The rig has allowed well defined and repeatable experiments to be performed and hence enable to study and assess boilover in a reproducible manner. In addition, visualisation of the fuel behaviour during the experiments could be obtained to better understand the formation and growth of hot zone, the boiling of water layer and hence the boilover occurrence. A number of small and larger scale experiments had been completed to obtain a wide spectrum of results, evaluating the effect of tank diameters, fuel depth, and water depth on the rate and extent of the boilover. The analysis of the results had elucidated further the processes of the hot zone formation and its growth, and hence mechanisms involved in the boilover occurrence. The important observation was that there are three stages observed in the mechanism of boilover incidence. At the start of the fire there is a stage when the hot zone is formed. This is followed by a period when the bottom of the hot zone moves downwards at a pseudo constant rate in which the distillation process (vaporisation of the fuel s lighter ends) is taking place. The final stage involved the heating up of the lowest fuel layer consisting of components with very high boiling points and occurrence of boilover. Based on the observations of the mechanisms involved in the hot zone formation and its growth, predictive calculations were developed which focus on the provision of an estimate on the time to boilover upon the establishment of a full surface fire and an estimate of the amount of fuel remaining in the tank prior to the occurrence of the boilover. A predictive tool was developed in order to provide predictions on the important parameters associated with a boilover event i.e. the time to boilover, the amount of fuel remaining in the tank prior to boilover and hence the quantity of fuel that would be ejected during boilover and the consequences of a boilover i.e. fire enlargement, fireball effects and the ground area affected by the expulsion of oil during a boilover event. The predictive tool developed is capable of providing good estimates of onset time to boilover and predicts consequences of the boilover. The tool predicting the time to boilover of the LASTFIRE field scale test and the laboratory scales tests was shown to produce predictions that correlated with the observed time to boilover. Apart from the time to boilover, the predictive calculation is also able to provide an estimate of fuel amount remained in the tank at the instance of boilover occurrence. Consequently, the tool is capable of predicting the quantity of burning fuel being ejected and hence the area affected by the extensive ground fire surrounding the tank. The predictive results are conservatives but yet show good agreement with observed time to boilover in real boilover incidents. Certain considerations in the development of safe and effective fire fighting strategies in handling fire scenario with a potential of boilover occurrence, can be assessed using the predictive tool developed.
|
3 |
Zdroje vody a čerpací stanoviště pro požární techniku v okrese Písek. / Water resources and water pumping sites for fire equipment in Písek district.VIKTORA, Vladimír January 2011 (has links)
In my diploma thesis I have created the updated version of water sources and pumping sites for fire equipment in the Písek district. I acquired large volumes of data by a detailed physical inspection of possible water sources in all villages in the Písek district. In my thesis I have mentioned water sources only in those villages that are classified into fire protection units, category II and III. The complete summary of all water sources and water pumping sites is on the attached CD. The data contain the name of the village, type of water source, GPS coordinates, additional information about the water source and any additional notes regarding repairs, distances from the village, etc. Photo documentation and the map section were produced for each water source. In many villages, there are hydrant networks which, in those villages where there is no water source, can have a substantial effect on fire safety. The thesis also includes the list of all hydrant networks in the Pisek district, including the owners and operators. The thesis can be used for the Operating and Information Centre of the Fire Brigade for the South Bohemian region which, for the demand for water for rescue and liquidation can send the unit directly to the water source according to the ascertained data. For some water sources, below the table in the note, there may be corrections or improvements that lead to a better use of these sources. The thesis monitors the existing status of the water and pumping sites for fire equipment in the Pisek district. I compared the acquired data with data from South Bohemian Region Regulation No.4/2003 at 2.12.2003. It results from the compared data that permanent updating and communication on the part of the municipalities with the Fire Brigade is necessary. In many places, water sources are closed and new water points originate with the possibility to pump this basic and main extinguishing agent.
|
Page generated in 0.0139 seconds