• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 11
  • 10
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise da produção de lodo de esgoto e da capacidade de disposição do aterro sanitário do Aurá na região metropolitana de Belém para os próximos 20 anos

CUNHA, Débora Suely Anjos 01 July 2009 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T12:29:01Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseProducaoLodo.pdf: 4416450 bytes, checksum: 55ede069de533de6e6b7cf44b8a528d3 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-20T11:13:19Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseProducaoLodo.pdf: 4416450 bytes, checksum: 55ede069de533de6e6b7cf44b8a528d3 (MD5) / Made available in DSpace on 2017-03-20T11:13:19Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseProducaoLodo.pdf: 4416450 bytes, checksum: 55ede069de533de6e6b7cf44b8a528d3 (MD5) Previous issue date: 2009-07-01 / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / A Região Metropolitana de Belém possui poucas e incompletas informações sobre a produção e destino final de lodo de esgoto, pois apenas pequena parte do lodo gerado nos tanques sépticos e nas ETEs coletivas é desaguado e disposto sem controle no Aterro Sanitário do Aurá, portanto, é muito comum o lançamento indevido de lodo em corpos d`água e no solo, o que agrava os problemas de poluição/contaminação na área urbana. Sendo assim, esse trabalho tem como objetivo analisar o aumento da produção de lodo e avaliar o seu impacto no Aterro Sanitário do Aurá. A pesquisa foi desenvolvida na Região Metropolitana de Belém, que é composta pelos municípios de Belém, Ananindeua, Benevides, Marituba e Santa Bárbara do Pará. Tendo sido dividida em duas fases. Na Fase I foram estimados os volumes de lodo de esgoto (bruto e desaguado) de tanques sépticos e de ETEs na RMB no período de 2009 a 2030, sendo a Fase II destinada à análise da capacidade do aterro sanitário do Aurá como local de disposição deste lodo. Durante a mesma foi constatado que apesar do aumento do volume de lodo desaguado não ter grande impacto no volume de resíduos sólidos domiciliares no período estudado, a falta de áreas disponíveis no Aterro Sanitário do Aurá é um problema que deve ser resolvido com a máxima brevidade, pois, caso contrário, os resíduos sólidos domiciliares e o lodo de esgoto gerados na Região Metropolitana de Belém, não serão dispostos adequadamente, já que a previsão é o rápido comprometimento do volume livre do Aterro Sanitário do Aurá. / Belém Metropolitan Region has few and incomplete informations about production and destination of sewage sludge, because just little part of the sludge generated in septic tank and collective Sewage Works is throwed away without control in Aurá Sanitary Landfill. Because of this, is usual to throw the sludge in water bodies and in the ground, worsen the problems of pollution/contamination in the urban areas. Therefore, this work has the objective of analyzing the increase of production of sludge and evaluate the impact in the Aurá Sanitary Landfill. The search was developed in Belém Metropolitan Region, composed by Belém, Ananindeua, Benevides, Marituba and Santa Bárbara do Pará. It was divided in 2 stages. In the first stage it was estimated the production of the sludge (brute and drained) of septic tanks and in the collective Sewage Works during 2009 to 2030, and the second one was the availability of an area to disposal in the Aurá Sanitary Landfill. In the period studied, it was verified that by the way of the increase of the content of sludge drainage doesn’t has too many impact in the content of the residence solid waste, the deficiency of the available areas in the Aurá Sanitary Landfill is a problem that has to be solved as soon as possible, otherwise residence solid waste and sewage sludge produced in Belém Metopolitan Region won’t be well disposal, as a matter of fact that the prevision is the fast implicate of the free content of Aurá Sanitary Landfill.
12

Caracterização e pré-tratamento de lodo de fossas e de tanques sépticos / Characterization and treatment of sludge originated from septic tanks

Borges, Nayara Batista 27 November 2009 (has links)
Fossas e tanques sépticos são sistemas de pequeno porte utilizados para tratamento parcial do esgoto sanitário produzido nas áreas urbana e rural, quando não beneficiados por sistema de esgotamento sanitário. Tal utilização se justifica principalmente por ser tecnologia que não exige muita dedicação operacional e ser de simples implantação. Apesar da vasta utilização dessas unidades no Brasil, há pouca informação sobre a caracterização, as condições de coleta, transporte, tratamento e destino final de resíduo (lodo) produzido nesses sistemas. Nesse sentido, o presente trabalho tem como objetivo a caracterização do lodo produzido nessas unidades; e, também, a concepção, o desenvolvimento e a avaliação de uma unidade piloto para pré-tratamento de lodo de fossas e tanques sépticos. Essa unidade, constituída por grade, desarenador e flotador, foi instalada no Campus da Universidade de São Paulo, junto da Estação de Tratamento de Esgoto do Campus - área 1, e vista à remoção de sólidos grosseiros, areia e materiais flutuantes, antes de seu lançamento na Estação de Tratamento de Esgoto do Campus. Foi feita a caracterização do lodo de tanques sépticos coletado in situ e do lodo proveniente dos caminhões limpa-fossas, descarregando em tanque pulmão de 15000 litros. A caracterização do lodo proveniente dos caminhões limpa-fossas foi realizada em duas campanhas (coletas), sendo uma feita na primeira visita ao local pré-definido, e outra realizada aproximadamente seis meses após a primeira coleta. Com intuito de aprimorar o método de análise das amostras do lodo in situ, com finalidade de melhor fragmentar o material particulado, foi testado o uso de ultrassom. Também, foi realizada a caracterização do lodo de fossas e tanques sépticos na Central de Recebimento de Resíduos na cidade de Campinas-SP - SANASA - Sociedade de Abastecimento de Água e Saneamento AS. Para tanto, foram coletadas amostras compostas de lodo descarregado por 24 caminhões. Foi feito teste complementar, com a finalidade de estudar a degradação do lodo flotado por processos anaeróbio e aeróbio. Mediante essas caracterizações pode-se constatar a grande heterogeneidade da composição do lodo e a elevada carga orgânica, que devem ser ponderados com relação a impactos no meio ambiente e em Estações de Tratamento de Esgoto. Contudo, nota-se a importância do pré-tratamento desse lodo antes de ser lançado em ETEs. A unidade piloto foi operada com diferentes taxas de aplicação superficial (80; 110; 140 e 200 \'M POT.3\'/\'M POT.2\'.dia), quando foram obtidas remoções de 91,7% de sólidos suspensos; 89,3% de DQO e 81,9% de óleos e graxas. Pelos resultados obtidos foi demonstrada a eficiência do sistema de flotação na remoção de óleos e graxas e dos sólidos suspensos. A digestão aeróbia do lodo flotado mostrou-se eficiente quando foi aplicado inócuo com período de aeração superior a 20 dias, sendo que foram obtidas eficiências de 88,3% e 90% para remoção de DQO e de óleos e graxas, respectivamente. / Septic tanks are small structures used for partial treatment of wastewater produced from urban and rural areas. It utilization is justify mainly by simplicity of construction and for being a technology that requires low operational dedication. Although it is a technology vastly used in Brazil, there is not much information about the characteristics of the waste dumped in there, and the conditions of collection, transport, and final destination of the sludge generated in the system. The objective of this research was characterize the sludge originated from septic tanks and to design, construct and evaluate a treatment unit model to be used for prior treatment of the sludge generated in those septic tanks. This unit, composed by a sieve, a degritter, and a flotation device, was assembled in the São Paulo University Campus, near the area 1 from the campus Wasterwater Treatment Plant (WWTP). It had the purpose to remove har solid particle, sand and the floating material before their entry in the Wasterwater Treatment Plant. Was made to characterize the sludge septic tank collected in situ and the sludge originated from the Septic Pumper Truck, unloaded into a tank of 15000 L. Furthermore, the characterization of the sludge originated from the Septic Pumper Truck was performed twice, once in the material collected in the first visit to the defined location and the other in the material collected about six months after the first collection. The use of ultrasound was tested to ameliorate the fragmentation of the particulate material and to improve the method of analysis of the sludge in situ. Additionally, it was characterized the sludge from septic tanks in the Waste Reception Center from the city of Campinas, São Paulo State - SANASA - Society of Water Supply and Sanitation in composite samples collected from 24 trucks during the unloading. Septic Pumper Truck in th Waste Receptation Center. A complementing test was performed in order to text the degradation of the floated sludge by anaerobic and aerobic processes. The characterizations revealed a great heterogeneity in the composition of the sludge and the high organic content, which should be taken in consideration regarding the impacts in the environment and in the WWTP. This underlines the importance of treatment of the sludge prior to discharging into the WWTP. The pilot plant was managed to work at different rates of surface sludge application (80, 110, 140 and 200 \'M POT.3\'/\'M POT.2\'.day). The 110 \'M POT.3\'/\'M POT.2\'.day rate displayed the highest efficiency with the removal of 91.7% of suspended solids, 89.3% of the chemical oxygen demand, and 81 9% of oils and waxes. The results showed the efficiency of the flotation system in the removal of suspended solids, oil and greases. The aerobic digestion of the floated material was efficient when it received inoculation with aeration period greater than 20 days, which allowed CDO the removal of 88.3% and 90% of oil and greases.
13

Caracterização e pré-tratamento de lodo de fossas e de tanques sépticos / Characterization and treatment of sludge originated from septic tanks

Nayara Batista Borges 27 November 2009 (has links)
Fossas e tanques sépticos são sistemas de pequeno porte utilizados para tratamento parcial do esgoto sanitário produzido nas áreas urbana e rural, quando não beneficiados por sistema de esgotamento sanitário. Tal utilização se justifica principalmente por ser tecnologia que não exige muita dedicação operacional e ser de simples implantação. Apesar da vasta utilização dessas unidades no Brasil, há pouca informação sobre a caracterização, as condições de coleta, transporte, tratamento e destino final de resíduo (lodo) produzido nesses sistemas. Nesse sentido, o presente trabalho tem como objetivo a caracterização do lodo produzido nessas unidades; e, também, a concepção, o desenvolvimento e a avaliação de uma unidade piloto para pré-tratamento de lodo de fossas e tanques sépticos. Essa unidade, constituída por grade, desarenador e flotador, foi instalada no Campus da Universidade de São Paulo, junto da Estação de Tratamento de Esgoto do Campus - área 1, e vista à remoção de sólidos grosseiros, areia e materiais flutuantes, antes de seu lançamento na Estação de Tratamento de Esgoto do Campus. Foi feita a caracterização do lodo de tanques sépticos coletado in situ e do lodo proveniente dos caminhões limpa-fossas, descarregando em tanque pulmão de 15000 litros. A caracterização do lodo proveniente dos caminhões limpa-fossas foi realizada em duas campanhas (coletas), sendo uma feita na primeira visita ao local pré-definido, e outra realizada aproximadamente seis meses após a primeira coleta. Com intuito de aprimorar o método de análise das amostras do lodo in situ, com finalidade de melhor fragmentar o material particulado, foi testado o uso de ultrassom. Também, foi realizada a caracterização do lodo de fossas e tanques sépticos na Central de Recebimento de Resíduos na cidade de Campinas-SP - SANASA - Sociedade de Abastecimento de Água e Saneamento AS. Para tanto, foram coletadas amostras compostas de lodo descarregado por 24 caminhões. Foi feito teste complementar, com a finalidade de estudar a degradação do lodo flotado por processos anaeróbio e aeróbio. Mediante essas caracterizações pode-se constatar a grande heterogeneidade da composição do lodo e a elevada carga orgânica, que devem ser ponderados com relação a impactos no meio ambiente e em Estações de Tratamento de Esgoto. Contudo, nota-se a importância do pré-tratamento desse lodo antes de ser lançado em ETEs. A unidade piloto foi operada com diferentes taxas de aplicação superficial (80; 110; 140 e 200 \'M POT.3\'/\'M POT.2\'.dia), quando foram obtidas remoções de 91,7% de sólidos suspensos; 89,3% de DQO e 81,9% de óleos e graxas. Pelos resultados obtidos foi demonstrada a eficiência do sistema de flotação na remoção de óleos e graxas e dos sólidos suspensos. A digestão aeróbia do lodo flotado mostrou-se eficiente quando foi aplicado inócuo com período de aeração superior a 20 dias, sendo que foram obtidas eficiências de 88,3% e 90% para remoção de DQO e de óleos e graxas, respectivamente. / Septic tanks are small structures used for partial treatment of wastewater produced from urban and rural areas. It utilization is justify mainly by simplicity of construction and for being a technology that requires low operational dedication. Although it is a technology vastly used in Brazil, there is not much information about the characteristics of the waste dumped in there, and the conditions of collection, transport, and final destination of the sludge generated in the system. The objective of this research was characterize the sludge originated from septic tanks and to design, construct and evaluate a treatment unit model to be used for prior treatment of the sludge generated in those septic tanks. This unit, composed by a sieve, a degritter, and a flotation device, was assembled in the São Paulo University Campus, near the area 1 from the campus Wasterwater Treatment Plant (WWTP). It had the purpose to remove har solid particle, sand and the floating material before their entry in the Wasterwater Treatment Plant. Was made to characterize the sludge septic tank collected in situ and the sludge originated from the Septic Pumper Truck, unloaded into a tank of 15000 L. Furthermore, the characterization of the sludge originated from the Septic Pumper Truck was performed twice, once in the material collected in the first visit to the defined location and the other in the material collected about six months after the first collection. The use of ultrasound was tested to ameliorate the fragmentation of the particulate material and to improve the method of analysis of the sludge in situ. Additionally, it was characterized the sludge from septic tanks in the Waste Reception Center from the city of Campinas, São Paulo State - SANASA - Society of Water Supply and Sanitation in composite samples collected from 24 trucks during the unloading. Septic Pumper Truck in th Waste Receptation Center. A complementing test was performed in order to text the degradation of the floated sludge by anaerobic and aerobic processes. The characterizations revealed a great heterogeneity in the composition of the sludge and the high organic content, which should be taken in consideration regarding the impacts in the environment and in the WWTP. This underlines the importance of treatment of the sludge prior to discharging into the WWTP. The pilot plant was managed to work at different rates of surface sludge application (80, 110, 140 and 200 \'M POT.3\'/\'M POT.2\'.day). The 110 \'M POT.3\'/\'M POT.2\'.day rate displayed the highest efficiency with the removal of 91.7% of suspended solids, 89.3% of the chemical oxygen demand, and 81 9% of oils and waxes. The results showed the efficiency of the flotation system in the removal of suspended solids, oil and greases. The aerobic digestion of the floated material was efficient when it received inoculation with aeration period greater than 20 days, which allowed CDO the removal of 88.3% and 90% of oil and greases.

Page generated in 0.0309 seconds