• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Requisitos para aplicação e avaliação de confiabilidade metrologica em laboratorio de metrologia

Franco, Samuel Mendes 28 June 1996 (has links)
Orientador: Olivio Novaski / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-21T17:29:38Z (GMT). No. of bitstreams: 1 Franco_SamuelMendes_M.pdf: 17660947 bytes, checksum: f85537ef30834eb17e44fdec1b84b206 (MD5) Previous issue date: 1996 / Resumo: Para atender as atuais exigências metrológicas, um laboratório de metrologia deve assegurar que as medições sejam realizadas com a exatidão pretendida, caso este laboratório, pretenda ser reconhecido como capacitado para realizar calibrações e ensaios específicos. O objetivo deste trabalho é apresentar os requisitos para aplicação e avaliação de confiabilidade metrológica em laboratório de metrologia e, através destes requisitos, avaliar a comprovação metrológica de um laboratório de metrologia pertencente à RBC (Rede Brasileira de Calibração) para a calibração de blocos padrão. Neste sentido, foi determinada a incerteza de medição, aplicada aos blocos padrão, e avaliado o resultado obtido pelo cálculo, com o fornecido pela recomendação do INMETRO. Observou-se que, os valores recomendados, fornecidos pelo INMETRO podem ser utilizados, desde que, as diferenças, em relação às expressões determinadas, sejam pequenas / Abstract: To answer the present is metrological requirements a metrological laboratory shall assure that the measurements are performed accórding to the intended accuracy, in case this laboratory want to be recognized competent to carry out specific calibrations or tests. The goal of this work is to report the requirements for application and evaluation of metrological traceability in metrology laboratory and through these requirements to evaluate the metrological confirmation of a metrology laboratory belonging to RBC (Rede Brasileira de Calibração) to the gauge blocks calibration. In this sense the measurement uncertainty was determined, applied to gauge blocks, and evaluated the result obtained through calculuses with the one provided for recommendation of INMETRO was evaluated. It was observed that the recommended values provided for INMETRO can be used since that, the differences related to the determined expressions, are small / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
2

Caracterizações especiais de combustíveis fóssil e renovável / Special characterizations of fossil and renewable fuels

Lopes, Milena Savioli, 1985- 16 August 2018 (has links)
Orientador: Maria Regina Wolf Maciel / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-16T09:42:59Z (GMT). No. of bitstreams: 1 Lopes_MilenaSavioli_M.pdf: 2642176 bytes, checksum: 41aa3694413f6af27a3d7d75233a5cc6 (MD5) Previous issue date: 2010 / Resumo: Atualmente, as técnicas de medição e o desenvolvimento de novos processos e produtos demandam análises cada vez mais sofisticadas, para atender às especificações de mercado e ambientais. A escolha do método de análise, o seu entendimento teórico e a correta metodologia de execução devem ser avaliados adequadamente para que a exatidão dos resultados seja a maior possível. Pesquisas têm sido continuamente realizadas na busca de métodos analíticos confiáveis, cada vez mais rápidos e, na medida do possível, de menores custos. Pretende-se, assim, chamar a atenção para este tipo de abordagem, que garante a qualidade de resultados e formação de recursos humanos em área tecnológica. Neste contexto, o objetivo dessa dissertação de mestrado foi realizar um estudo sobre técnicas de caracterização e análises físico-químicas de propriedades consideradas fundamentais. Uma compilação de equipamentos e sua respectiva teoria foram estudadas a fim de agregar conhecimento. Como matérias-primas, foram escolhidos três produtos dos mais importantes, hoje, como aplicações: petróleo, biodiesel e óleo fúsel. Os resultados mostraram que as técnicas estudadas de DSC e Reômetro necessitam um maior cuidado na realização dos experimentos; cuidados estes que vão desde a operação do equipamento, até mesmo a introdução da amostra. Outras, como o viscosímetro capilar e o titulador volumétrico de Karl Fischer são, consideravelmente, simples, fornecendo resultados rápidos e precisos / Abstract: Currently, measurement techniques and development of new products and processes require increasingly sophisticated analysis, to meet market specifications and environmental issues. The choice of method of analysis, their theoretical understanding and correct implementation methodology should be evaluated properly, so that the accuracy of the results is the highest possible. Research has been conducted continuously in search of reliable analytical methods, increasingly fast and as far as possible to lower costs. The aim is thus to draw attention to this type of approach, which ensures the quality of results and training of human resources in the technological area. In this context, the objective of this dissertation was to conduct a study on characterization techniques and physico-chemical properties to be essential. A compilation of equipment and accompanying theory were studied in order to aggregate knowledge. As raw materials, were chosen three of the most important products today as applications: Petroleum, biodiesel and fusel oil. The results showed that the techniques studied of DSC and Rheometer require greater care in carrying out the experiments, care ranging from those operating the equipment, even the introduction of the sample. Others, like the viscometer capillary and volumetric Karl Fischer titrator are pretty simple, providing fast and accurate results / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química
3

Contribuições à caracterização estatística do canal de rádio móvel e estimação de parâmetros por máxima verossimilhança / Contributions to the statistical characterization of mobile radio channel and parameter estimation by maximum likelihood

Ribeiro, Antonio Marcelo Oliveira, 1970- 23 August 2018 (has links)
Orientador: Evandro Conforti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-23T23:28:57Z (GMT). No. of bitstreams: 1 Ribeiro_AntonioMarceloOliveira_D.pdf: 6175407 bytes, checksum: 03c529ed2452256d1369e23e047687ec (MD5) Previous issue date: 2013 / Resumo: Os efeitos provocados pelo ambiente de propagação sobre o sinal transmitido, assim como as condições impostas pela mobilidade do receptor, afetam diretamente a qualidade de serviço em sistemas de comunicação sem fios. Portanto, é necessário compreender e analisar os efeitos de degradação que o canal terá sobre um dado sistema de comunicação de dados e, dessa forma, avaliar a necessidade de medidas para mitigar os eventuais efeitos prejudiciais do canal. Neste trabalho, apresenta-se uma caracterização estatística do canal de rádio móvel, a partir de medições em campo nas bandas de 1800, 2500 e 3500 MHz, através de uma técnica simples de aquisição da envoltória do sinal. Em particular, são calculadas, para a envoltória, funções de distribuição de probabilidade, taxas de cruzamentos, duração de desvanecimento e sua distribuição, funções de correlação espacial e em frequência, tempo de coerência e largura de banda de coerência. Realiza-se, igualmente, uma análise comparativa destes resultados com os seguintes modelos estatísticos: Rayleigh, Nakagami, Rice, Weibull, Hoyt (Nakagami-q) e ?-?. Além disso, é dada ênfase à estimação de parâmetros dos modelos de canal de rádio, através de dois métodos: momentos (MoM) e máxima verossimilhança (ML). Neste contexto, obtém-se expressões para a variância e o intervalo de confiança, assintóticos, de estimadores ML, baseadas na informação de Fisher que uma amostra aleatória contém a respeito do parâmetro a ser estimado. De forma geral, foi observado um bom ajuste entre as medidas em campo e correspondentes curvas teóricas, para estatísticas de primeira e segunda ordem da envoltória. As medições em campo deste trabalho mostraram que os estimadores ML agruparam mais as curvas teóricas, em torno da curva experimental, quando comparados aos estimadores MoM. Adicionalmente, a matriz de covariância dos estimadores ML para ? e ?, obtida a partir das medições em campo, mostrou que a variância do estimador de ? é, pelo menos, dez vezes maior que aquela do estimador de ?. Igualmente, valores medidos de correlação espacial apresentaram bom ajuste aos modelos teóricos, em termos de uma tendência geral de variação. Em particular, curvas de distribuição cumulativa do tempo de coerência, , para medidas em campo em 3500MHz, mostraram que é maior que 1,7 ms, para 90% do tempo, quando o receptor se move a 30 km/h. Por fim, medidas em campo da largura de banda de coerência, em 1800MHz, revelaram que um valor de ?f < 60 kHz irá garantir um nível de correlação da envoltória maior que 0,9, para 90% do tempo / Abstract: The propagation environment effects on the transmitted signal as well as the conditions imposed by the receiver mobility directly affect the quality of service (QoS) in wireless communication systems. Therefore, it is necessary to understand and analyze the degradation effects inflicted by the channel on a given data communication system, in order to evaluate the measures to mitigate these deleterious effects. In this thesis, we present a statistical characterization of the mobile radio channel based on field measurements performed over the 1800, 2500, and 3500 MHz bands, using a simple technique for acquiring the signal envelope. In particular, envelope statistics for probability distribution functions were calculated, as well as the crossing rates, duration of fading and its distribution, spatial and frequency correlation functions, coherence time, and coherence bandwidth. A comparative analysis of these results was also carried out against the following statistical models: Rayleigh, Nakagami, Rice, Weibull, Hoyt (Nakagami-q), and ?-?. Also, emphasis is given to the parameter estimation of radio channel models using two methods: moments (MoM) and maximum likelihood (ML). In this context, expressions for the asymptotic variance and confidence interval of ML estimators were obtained, based on the Fisher information a random sample contains over the parameter to be estimated. In general, there was a good fit between the field measurements and corresponding theoretical curves for envelope statistics of first and second order. Field measurements of this work have shown that ML estimators grouped more the theoretical curves around the experimental one, when compared to MoM estimators. Additionally, the covariance matrix of ML estimators for ? and ?, obtained from field measurements, showed that the variance of ? estimator is at least ten times greater than the one of ? estimator. Moreover, measured values of spatial correlation showed a good .t to the theoretical models, in terms of a general tendency of variation. Particularly, cumulative distribution curves of the coherence time , for field measurements at 3500MHz, showed that is greater than 1,7 ms for 90% of time when the receiver is moving at 30 km/h. Finally, 1800- MHz field measurements of coherence bandwidth revealed that a value of ?f < 60 kHz will ensure a level of envelope correlation greater than 0.9 for 90% of time / Doutorado / Telecomunicações e Telemática / Doutor em Engenharia Elétrica

Page generated in 0.0572 seconds