• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento e avaliação de um sistema de resfriamento evaporativo, por aspersão intermitente, na cobertura de aviarios usando modelos de escala distorcida

Rodrigues, Edmundo Henrique Ventura 30 April 1998 (has links)
Orientador: Irenilza de Alencar Naas / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-23T15:56:13Z (GMT). No. of bitstreams: 1 Rodrigues_EdmundoHenriqueVentura_D.pdf: 9133463 bytes, checksum: 0d45f7fc68559e693bda777695d1f2bf (MD5) Previous issue date: 1998 / Resumo: A avicultura tecnificada está exigindo dada vez mais o controle das condições de conforto térmico das instalações, devido ao uso de aves de alto potencial genético, alto nível energético das dietas e aumento das taxas de ocupação. O objetivo geral deste trabalho foi desenvolver um sistema de resftiamento na cobertura, de natureza evaporativa, com uso de aspersão intermitente e de uma telha absorvente d' água, em instalações destinadas à produção de frangos de corte. Foram testados quatro tratamentos: TI - cobertura com telhas onduladas de cimento-amianto, capeadas com argamassa absorvente de cimento-vermiculita, sujeita à aspersão intermitente (5 minutos molhando / 10 minutos secando); T2 - cobertura com telhas onduladas de cimento-amianto sujeita à aspersão intermitente; T3 - cobertura com telhas onduladas de cimento-amianto, capeadas com argamassa absorvente de cimento-vermiculita; T4 - cobertura com telhas onduladas de cimento-amianto (testemunha). A avaliação das condições ambientais foi feita, para condições climáticas de meia estação correspondente a clima quente e seco, em modelos reduzidos em escala distorcida, que simulavam as instalações avícolas, por meio da temperatura de globo negro (Tgn),índice de temperatura de globo e umidade (ITGU) e da carga térmica radiante (CTR). A produtividade zootécnica foi avaliada por meio do ganho - de peso, pelo programa computacional Pro-Frango, para as condições ambientais propiciadas pelo sistema de resmamento desenvolvido. Tanto para a condição de ventilação natural deficiente, quanto para a condição de ventilação natural mais acentuada, a Tgn,o ITGU e a CTR apresentaram diferenças de grande magnitude e estatisticamente significativas,entre os tratamentos que usaram o sistema de resfriamento com uso de microaspersão intermitente e os que não usaram. Quando se comparam os tratamentos que utilizaram o sistema de resfriamento, verifica-se que as diferenças entre as grandezas térmicas analisadas, já não se apresentaram tão acentuadas, embora sejam até significativas estatisticamente para algumas horas do dia. Como comportamento geral, pode-se afirmar que, pela parte da manhã, o tratamento com uso de aspersão e capeamento absorvente nas telhas, apresentou valores de Tgn, ITGU e CTR que indicam melhores condições de conforto térmico. Na parte intermediária do dia ocorre uma inversão de comportamento, sendo o tratamento com aspersão e sem capeamento o que apresentou melhores condições de conforto térmico. No final da tarde, ocorre nova inversão de comportamento, com o tratamento com micro-aspersão e capeamento das telhas apresentando valores de Tgn,ITGU e CTR mais favoráveis. Sob o ponto de vista econômico sugere-se o uso da micro-aspersão intermitente e da telha ondulada de cimento-amianto, tendo o sistema o potencial de propiciar o retorno econômico seguinte: a) O acréscimo de ganho de peso diário, durante a última semana de criação (42 aos 49 dias), variou de 58 g/dia.ave, para uma instalação com ventilação deficiente, a 28 g/dia.ave, para uma instalação bem ventilada, sujeita ao efeito de vento e termossifiío;para casos de ventilação muito deficiente verificou-se que o sistema se paga com a criação de 4 lotes de frangos, enquanto que, para situações de melhores condições de ventilação natural, verificou-se que o sistema se paga com a criação de cerca de 8 lotes de frangos / Abstract: Technical poultry production is presently requiring more environmental control on the thermal cornfort characteristics because of the use of high potential genetic birds, diets energy high levei, and an increase of birds density. The general objective of this research was to develop a system for roof cooling based on the evaporative cooling concept, using intermittent dripping and a water absorbent tile, for poultry production houses. The evaluation of environrnental aspects was based on the warm and dry season climatic conditions, using small and distorted scale models simulating the poultry houses. The thermal evaluation was proceeded using the black globe temperature (Tg), the black globe and humidity index (BGHI), and thermal radiation load (TRL). The zootechnical response was based on the weight gain measurements using the software Pro-Frango, for the environrnental conditions results. For the insufficient natural ventilation system as well as for the well naturally ventilated one the Tg, BGHI and TRL showed higWy statistical significant differences, when comparing the treatments of using the system with the system of roof cooling, and the one that does not uses the cooling system. When comparing both treatments that used cooling roof it can be found that the differences are not as higWy significant, even though it can be found statistical significantfor some hours ofthe day. As a general behavior it can be said that, during the mornings the treatment of cooling roof using intermittent dripping and a water absorbent tile showed Tg, BGHI and TRL values that indicates better thermal cornfort conditions. This behavior repeats again during the late afternoon. During midday it happened an inversion on the thermal behavior showing that the treatment using dripping and without tile absorbent covering got the best results. Regarding the economical aspect it can be suggested the use of dripping on fiber cement roof for offering the following benefit: a) the increase on weight gain during the last week of production (42-49 days) varied ITom 58g/day.bird to a house poorly ventilated, to 28g/day.birdfor a well ventilated house; b) for poorly ventilated houses it was verified that the system has economical profit after 4 flocks, while for better naturally ventilated conditions the systems presents economicalprofit after 8 flocks / Doutorado / Construções Rurais e Ambiencia / Doutor em Engenharia Agrícola
2

Análise de desempenho térmico de telhas de fibrocimento tratadas com revestimentos brancos e submetidas à aspersão de água / Analysis thermal performance of fiber cement tiles treated with white coatings and submitted to water spraying

Teixeira, Carla Fernanda Barbosa, 1977- 06 May 2013 (has links)
Orientador: Lucila Chebel Labaki. / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-23T11:44:35Z (GMT). No. of bitstreams: 1 Teixeira_CarlaFernandaBarbosa_D.pdf: 4846787 bytes, checksum: a2bbec42880bcecfdd43b8f22e0fecf7 (MD5) Previous issue date: 2013 / Resumo: A busca por materiais, tecnologias ou meios que tornem as edificações mais eficientes energeticamente é uma meta de pesquisadores, educadores e projetistas não só no Brasil, mas também no mundo. O uso de cores claras em coberturas tem sido bastante estudado como estratégia de resfriamento para climas quentes. Este trabalho tem como objetivo analisar o desempenho térmico de acabamentos de cor branca em coberturas e estimar o consumo de energia para um ambiente com cobertura branca. Adicionado ao emprego de acabamentos refletivos, empregou-se a aspersão de água pluvial sobre os acabamentos empregados. A caracterização do desempenho de acabamentos de tinta na cor branca requisitou a realização de ensaios para determinar as características dos acabamentos nas superfícies das telhas: emissividade, refletância solar e absorção de água aspergida. Para tanto, a revisão bibliográfica do assunto foi necessária para investigar metodologias aplicadas in pesquisas realizadas no mundo. Em telhas de fibrocimento foram aplicadas tintas imobiliárias comuns (de diferentes composições químicas, porém de mesma cor branca) associadas à aspersão de água e expostas a intempéries ambientais. Temperaturas superficiais internas das telhas e variáveis meteorológicas foram coletadas e analisadas, conjuntamente com dados dos ensaios de refletância solar, emissividade térmica e absorção de água na superfície das telhas de fibrocimento. Os resultados para a técnica refletiva de acabamentos de cor clara comprovaram as expectativas, no entanto, quando esta técnica foi associada à aspersão de água nas superfícies, os resultados foram otimizados. Esses resultados ilustram a necessidade da atenção na especificação do tipo de acabamento branco. Estimou-se, através de simulação térmica, a influência do acabamento branco no consumo de energia anual de um ambiente. O propósito deste trabalho é contribuir com informações adicionais em relação ao acabamento de cor branca, atenuando as temperaturas da cobertura de uma edificação, como demonstrar que o emprego de água pluvial pode atenuar o volume escoado pelas vias na estação chuvosa / Abstract: The search for materials, technologies and ways that can get constructions more energy efficient has been a concern of researches, educators and designers not only in Brazil, but also in the world. The use of light colors on roofing has been studied a lot; like cooling strategy for hot climates. The aim of this work is to analyze thermal performance of white coatings on roofing and to estimate energy savings in a room with white coating on roofing. Evaporative cooling, added to reflective cooling, was used through rain-water spraying on coating surfaces. Some testing on coatings as thermal emissivity, solar reflectance and absorption of sprayed water were requested for characterization of coatings thermal performance. In consequence of that literature review related to these themes was necessary to investigate methodologies applied in researches which have been done in the world. Commercial and ordinary paintings (of different chemical compositions, but with same color: white) were applied on fiber cement tiles in association to water spraying in weather conditions. Inside-surface temperatures and meteorological data were collected and analyzed together with solar reflectance, thermal emissivity and water absorption by tile coatings. Results of reflective technique proved expectations and illustrated that some attention is requested to choose the kind of white painting. However, when these coatings received water spraying on surfaces, they got the best results. The white coatings influences were considered through an annual thermal simulation energy saving. This work has the purpose to contribute with existing additional information in relation to white painting available, in order to get less roofing temperatures as well as to show that the rain water usage could be a tool for decreasing drained water on streets in rainy season / Doutorado / Arquitetura, Tecnologia e Cidade / Doutora em Arquitetura, Tecnologia e Cidade

Page generated in 0.0886 seconds