• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Temperaturas da superfície da bolsa escrotal antes e após colheita de sêmen mensuradas com termografia digital por infravermelho em Nelore (Bos taurus indicus) / Scrotal Surface Temperature before and after semen collection with digital infrared thermography in Nellore (Bos taurus indicus)

Souza, Camila Dutra de 19 March 2015 (has links)
Made available in DSpace on 2016-01-26T18:55:43Z (GMT). No. of bitstreams: 1 Camila Dutra de Souza.pdf: 334960 bytes, checksum: 3cdea75c6dcdafa19c8495c26e9b78e6 (MD5) Previous issue date: 2015-03-19 / The objective was to study the surface temperature of the scrotum with digital infrared thermography before and after semen collection, and the correlation of these temperatures with semen quality in Nelore bulls bred extensively. 80 Nelore bulls, with an average age of 60 months, of which was collected semen by electroejaculation and digital infrared thermograms (E-40®, FLIR) of the scrotum, before and after collection of semen and measurement of rectal temperature. The data were subjected to analysis of variance and means compared by Tukey at 5% and the correlations were obtained by Pearson at 5%. There were differences (P>0.05) between the surface temperatures of the scrotum, before and after semen collection, between the anatomical points analyzed, where, spermatic cords temperature (T1), temperatures of dorsal, medial and ventral thirds of the testicles (T2, T3 and T4), and epididymal tail temperature. However, there was no difference (P>0.05) comparing times before and after semen collection between the temperatures of each anatomical point of the scrotum. There was decrease in scrotal surface temperature in the dorso-ventral axis, where the difference between spermatic cord temperature (T1) and epididymal tails temperature was 4.04ºC, resulting in a good quality semen. There was correlation between T2 x total defects (r=0,30; P<0,05); T3 x minor defects (r=0,35; P<0,05); T3 x major defects (r=0,30; P<0,05) and T3 x total defects (r=0,42; P<0,05); T4 x minor defects (r=0,30; P<0,05); T4 x major defects (r=0,28; P<0,05) and T4 x total defects (r=0,37; P<0,05); T5 x major defects (r=0,29; P<0,05) e T5 x total defects (r=0,28; P<0,05). There was correlation between rectal temperature RT x T1 (r=0,51; P<0,05); RT x T2 (r=0,43; P<0,05); RT x T3 (r=0,37; P<0,05); RT x T4 (r=0,33; P<0,05) and RT x T5 (r=0,32; P<0,05). The digital infrared thermography is a complementary exam of image with accuracy in the measurements of the scrotal surface temperature indicated before and after semen collection of the bulls bred extensively. Therefore, is recommended this technique as of the screening to detect the adequate scrotal thermoregulation in the breeding bulls selection. / Objetivou-se estudar a temperatura da superfície da bolsa escrotal por meio da termografia digital por infravermelho antes e após a colheita de sêmen bem como a correlação dessas temperaturas com a qualidade do sêmen em touros Nelore criados extensivamente. Foram utilizados 80 touros Nelore, com idade média de 60 meses, dos quais foi coletado o sêmen por eletroejaculação e termografias digitais por infravermelho (E40®, Flir) da bolsa escrotal foram realizadas antes e após a colheita do sêmen e mensurada a temperatura retal. Os dados foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey a 5% e as correlações obtidas pelo coeficiente de Pearson a 5%. Houve diferenças (P<0,05) para as temperaturas da superfície da bolsa escrotal, antes e após a colheita de sêmen, entre os pontos anatômicos estudados, sendo: (T1) temperaturas dos cordões espermáticos, (T2, T3 e T4) temperaturas dos terços dorsal, médio e ventral dos testículos, respectivamente e (T5) temperaturas das caudas dos epidídimos. No entanto, não houve diferença (P>0.05) entre os momentos, antes e após a colheita de sêmen entre as temperaturas dos pontos anatômicos da bolsa escrotal. Houve redução na temperatura da superfície da bolsa escrotal no eixo dorso-ventral, sendo a diferença entre a temperatura do cordão espermático (T1) e cauda do epidídimo (T5) de 4,04ºC, resultando na boa qualidade do sêmen. Houve correlação entre: T2 x defeitos espermáticos totais (r=0,30; P<0,05); T3 x defeitos menores (r=0,35; P<0,05); T3 x defeitos maiores (r=0,30; P<0,05) e T3 x defeitos totais (r=0,42; P<0,05); T4 x defeitos menores (r=0,30; P<0,05); T4 x defeitos maiores (r=0,28; P<0,05) e T4 x defeitos totais (r=0,37; P<0,05); T5 x defeitos maiores (r=0,29; P<0,05) e T5 x defeitos totais (r=0,28; P<0,05). Houve correlação entre temperatura retal (TR) x T1 (r=0,51; P<0,05); TR x T2 (r=0,43; P<0,05); TR x T3 (r=0,37; P<0,05); TR x T4 (r=0,33; P<0,05) e TR x T5 (r=0,32; P<0,05). A termografia digital por infravermelho é um exame de imagem complementar com acurácia nas mensurações da temperatura da superfície da bolsa escrotal indicada antes ou após a colheita de sêmen de bovinos criados extensivamente. Portanto, recomenda-se essa técnica como de triagem na detecção da termorregulação escrotal adequada na seleção de reprodutores.
2

Termografia digital por infravermelho no estudo de características reprodutivas de touros nelore (Bos taurus indicus) / Digital Infrared thermography in study of reproductive characteristics in Nellore bulls (Bos taurus indicus)

Souza, Camila Dutra de 19 March 2015 (has links)
Made available in DSpace on 2016-07-18T17:53:15Z (GMT). No. of bitstreams: 1 Camila Dutra de Souza.pdf: 334649 bytes, checksum: 4696659c0bafe83a9b94130700f561b2 (MD5) Previous issue date: 2015-03-19 / The objective was to study the surface temperature of the scrotum with digital infrared thermography before and after semen collection, and the correlation of these temperatures with semen quality in Nelore bulls bred extensively. 80 Nelore bulls, with an average age of 60 months, of which was collected semen by electroejaculation and digital infrared thermograms (E-40®, FLIR) of the scrotum, before and after collection of semen and measurement of rectal temperature. The data were subjected to analysis of variance and means compared by Tukey at 5% and the correlations were obtained by Pearson at 5%. There were differences (P>0.05) between the surface temperatures of the scrotum, before and after semen collection, between the anatomical points analyzed, where, spermatic cords temperature (T1), temperatures of dorsal, medial and ventral thirds of the testicles (T2, T3 and T4), and epididymal tail temperature. However, there was no difference (P>0.05) comparing times before and after semen collection between the temperatures of each anatomical point of the scrotum. There was decrease in scrotal surface temperature in the dorso-ventral axis, where the difference between spermatic cord temperature (T1) and epididymal tails temperature was 4.04ºC, resulting in a good quality semen. There was correlation between T2 x total defects (r=0,30; P<0,05); T3 x minor defects (r=0,35; P<0,05); T3 x major defects (r=0,30; P<0,05) and T3 x total defects (r=0,42; P<0,05); T4 x minor defects (r=0,30; P<0,05); T4 x major defects (r=0,28; P<0,05) and T4 x total defects (r=0,37; P<0,05); T5 x major defects (r=0,29; P<0,05) e T5 x total defects (r=0,28; P<0,05). There was correlation between rectal temperature RT x T1 (r=0,51; P<0,05); RT x T2 (r=0,43; P<0,05); RT x T3 (r=0,37; P<0,05); RT x T4 (r=0,33; P<0,05) and RT x T5 (r=0,32; P<0,05). The digital infrared thermography is a complementary exam of image with accuracy in the measurements of the scrotal surface temperature indicated before and after semen collection of the bulls bred extensively. Therefore, is recommended this technique as of the screening to detect the adequate scrotal thermoregulation in the breeding bulls selection. / Objetivou-se estudar a temperatura da superfície da bolsa escrotal por meio da termografia digital por infravermelho antes e após a colheita de sêmen bem como a correlação dessas temperaturas com a qualidade do sêmen em touros Nelore criados extensivamente. Foram utilizados 80 touros Nelore, com idade média de 60 meses, dos quais foi coletado o sêmen por eletroejaculação e termografias digitais por infravermelho (E40®, Flir) da bolsa escrotal foram realizadas antes e após a colheita do sêmen e mensurada a temperatura retal. Os dados foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey a 5% e as correlações obtidas pelo coeficiente de Pearson a 5%. Houve diferenças (P<0,05) para as temperaturas da superfície da bolsa escrotal, antes e após a colheita de sêmen, entre os pontos anatômicos estudados, sendo: (T1) temperaturas dos cordões espermáticos, (T2, T3 e T4) temperaturas dos terços dorsal, médio e ventral dos testículos, respectivamente e (T5) temperaturas das caudas dos epidídimos. No entanto, não houve diferença (P>0.05) entre os momentos, antes e após a colheita de sêmen entre as temperaturas dos pontos anatômicos da bolsa escrotal. Houve redução na temperatura da superfície da bolsa escrotal no eixo dorso-ventral, sendo a diferença entre a temperatura do cordão espermático (T1) e cauda do epidídimo (T5) de 4,04ºC, resultando na boa qualidade do sêmen. Houve correlação entre: T2 x defeitos espermáticos totais (r=0,30; P<0,05); T3 x defeitos menores (r=0,35; P<0,05); T3 x defeitos maiores (r=0,30; P<0,05) e T3 x defeitos totais (r=0,42; P<0,05); T4 x defeitos menores (r=0,30; P<0,05); T4 x defeitos maiores (r=0,28; P<0,05) e T4 x defeitos totais (r=0,37; P<0,05); T5 x defeitos maiores (r=0,29; P<0,05) e T5 x defeitos totais (r=0,28; P<0,05). Houve correlação entre temperatura retal (TR) x T1 (r=0,51; P<0,05); TR x T2 (r=0,43; P<0,05); TR x T3 (r=0,37; P<0,05); TR x T4 (r=0,33; P<0,05) e TR x T5 (r=0,32; P<0,05). A termografia digital por infravermelho é um exame de imagem complementar com acurácia nas mensurações da temperatura da superfície da bolsa escrotal indicada antes ou após a colheita de sêmen de bovinos criados extensivamente. Portanto, recomenda-se essa técnica como de triagem na detecção da termorregulação escrotal adequada na seleção de reprodutores.

Page generated in 0.0595 seconds