• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 25
  • 25
  • 9
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Radiation force modeling for ICESat precision orbit determination

Webb, Charles Edward, 1968- 22 August 2011 (has links)
Not available / text
22

Desenvolvimento de sistema automatizado de baixo custo para coleta e armazenamento de dados de variáveis climáticas: aplicações no ambiente agrícola / Development of a low-cost, automated system for collecting and storing climate data: applications in an agricultural environment

Palmieri, Anderson Marcelli 11 December 2009 (has links)
As variáveis climáticas como temperatura do ar, umidade relativa do ar e radiação solar exercem grande influência sobre a produção agrícola, sendo capazes de ocasionar perdas durante o processo produtivo, acarretando em um aumento considerável no preço do produto final. Desse modo, a presente pesquisa teve por objetivo, desenvolver um sistema automatizado de baixo custo, tendo como base o microcontrolador Basic Step 1, o qual gerenciou um circuito eletrônico capaz de coletar e armazenar dados das respectivas variáveis climáticas, em um dispositivo de memória flash com conexão USB (pen drive). Além disso, o equipamento conta com o Data Basic - Software, o qual foi elaborado de modo a permitir ao usuário a análise dos dados coletados, com fácil visualização, devido à sua interface gráfica, bem como seu manuseio pelo fato de estabelecer uma conexão com planilha eletrônica (EXCEL). Os resultados mostraram a viabilidade do uso do sistema automatizado (Data-Basic) o qual funcionou com regularidade e precisão ao coletar e armazenar o sinal de tensão contínua enviado pelos 3 sensores. Assim, os dados coletados pelos sensores de umidade relativa do ar e temperatura, HIH 4000 e LM35, respectivamente demonstraram-se confiáveis, evidenciando a viabilidade do uso do equipamento, embora o sensor de radiação solar tenha demonstrado fragilidade e necessidade de uma pré-calibração antes de sua instalação. O custo de montagem do equipamento foi cerca de 50% menor em relação aos data loggers portáteis e apresentou fácil manutenção, pois permite a troca de placas como a do Basic Step1 ou do módulo de gravação PenBS, sem contar que os sensores são externos o que facilita também sua substituição caso seja necessário. Desse modo, pôde-se concluir a viabilidade de utilização deste instrumento mediante o seu baixo custo de produção, porém para longos períodos de coleta, recomenda-se a utilização de uma bateria externa a fim de se evitar a perda de dados pela falta de energia da rede elétrica, além disso, durante o processo de instalação, devem ser tomadas precauções no sentido de evitar a oxidação dos sensores e erros de medida, que podem afetar diretamente a qualidade dos dados coletados. / Climate variables such as air temperature, air humidity and solar radiation have a significant impact on agricultural yield. These variables affect the production process, and have a considerable influence on final product prices. The objective of this research, therefore, was to develop a low-cost, automated system, based on the Basic Step 1 microcontroller, to collect and store climate data in a flash memory device with USB connection (pen drive). In addition, the system includes the Data Basic Software, developed to enable the user to visualize the data in a graphical user interface and to manipulate the data in a spreadsheet (EXCEL). The results demonstrated the viability of the automated system (Data-Basic), which worked with regularity and precision in measuring and storing continuous voltage signals from 3 sensors. The measured data from the air humidity and temperature sensors, HIH4000 and LM35, were reliable, showing the viability of the system, while the radiation sensor was fragile and required pre calibration before installation. The cost of mounting the equipment was approximately 50% of that of a portable data logger. The system is easy to maintain, allows for the replacement of elements such as the microcontroller (Basic Step 1) or the storage module (PenBS), and has external sensors which can be replaced if necessary. It is feasibility to use this tool because of its low production cost. However, for extended periods of data collection, it is recommended that an external battery be added to prevent data loss during power outages. During the installation process, precautions should be taken to prevent the oxidation of the sensors, which would result in measurement errors, directly affect the quality of data collected.
23

Desenvolvimento de sistema automatizado de baixo custo para coleta e armazenamento de dados de variáveis climáticas: aplicações no ambiente agrícola / Development of a low-cost, automated system for collecting and storing climate data: applications in an agricultural environment

Anderson Marcelli Palmieri 11 December 2009 (has links)
As variáveis climáticas como temperatura do ar, umidade relativa do ar e radiação solar exercem grande influência sobre a produção agrícola, sendo capazes de ocasionar perdas durante o processo produtivo, acarretando em um aumento considerável no preço do produto final. Desse modo, a presente pesquisa teve por objetivo, desenvolver um sistema automatizado de baixo custo, tendo como base o microcontrolador Basic Step 1, o qual gerenciou um circuito eletrônico capaz de coletar e armazenar dados das respectivas variáveis climáticas, em um dispositivo de memória flash com conexão USB (pen drive). Além disso, o equipamento conta com o Data Basic - Software, o qual foi elaborado de modo a permitir ao usuário a análise dos dados coletados, com fácil visualização, devido à sua interface gráfica, bem como seu manuseio pelo fato de estabelecer uma conexão com planilha eletrônica (EXCEL). Os resultados mostraram a viabilidade do uso do sistema automatizado (Data-Basic) o qual funcionou com regularidade e precisão ao coletar e armazenar o sinal de tensão contínua enviado pelos 3 sensores. Assim, os dados coletados pelos sensores de umidade relativa do ar e temperatura, HIH 4000 e LM35, respectivamente demonstraram-se confiáveis, evidenciando a viabilidade do uso do equipamento, embora o sensor de radiação solar tenha demonstrado fragilidade e necessidade de uma pré-calibração antes de sua instalação. O custo de montagem do equipamento foi cerca de 50% menor em relação aos data loggers portáteis e apresentou fácil manutenção, pois permite a troca de placas como a do Basic Step1 ou do módulo de gravação PenBS, sem contar que os sensores são externos o que facilita também sua substituição caso seja necessário. Desse modo, pôde-se concluir a viabilidade de utilização deste instrumento mediante o seu baixo custo de produção, porém para longos períodos de coleta, recomenda-se a utilização de uma bateria externa a fim de se evitar a perda de dados pela falta de energia da rede elétrica, além disso, durante o processo de instalação, devem ser tomadas precauções no sentido de evitar a oxidação dos sensores e erros de medida, que podem afetar diretamente a qualidade dos dados coletados. / Climate variables such as air temperature, air humidity and solar radiation have a significant impact on agricultural yield. These variables affect the production process, and have a considerable influence on final product prices. The objective of this research, therefore, was to develop a low-cost, automated system, based on the Basic Step 1 microcontroller, to collect and store climate data in a flash memory device with USB connection (pen drive). In addition, the system includes the Data Basic Software, developed to enable the user to visualize the data in a graphical user interface and to manipulate the data in a spreadsheet (EXCEL). The results demonstrated the viability of the automated system (Data-Basic), which worked with regularity and precision in measuring and storing continuous voltage signals from 3 sensors. The measured data from the air humidity and temperature sensors, HIH4000 and LM35, were reliable, showing the viability of the system, while the radiation sensor was fragile and required pre calibration before installation. The cost of mounting the equipment was approximately 50% of that of a portable data logger. The system is easy to maintain, allows for the replacement of elements such as the microcontroller (Basic Step 1) or the storage module (PenBS), and has external sensors which can be replaced if necessary. It is feasibility to use this tool because of its low production cost. However, for extended periods of data collection, it is recommended that an external battery be added to prevent data loss during power outages. During the installation process, precautions should be taken to prevent the oxidation of the sensors, which would result in measurement errors, directly affect the quality of data collected.
24

Avaliação das doses efetivas e efetivas coletivas da radiação natural na região de Ribeirão Preto (SP) / Effective Dose and Collective Effective Dose Evaluation from Natural Radiation in the Region of Ribeirão Preto (SP)

Cavalcante, Fernanda 29 March 2012 (has links)
Medidas da radiação gama ambiental foram feitas em algumas regiões da cidade de Ribeirão Preto-SP, de forma a contribuir para o conhecimento acerca dos níveis desse tipo de radiação no estado de São Paulo e no território brasileiro. Escolheu-se determinar as médias anuais de dose efetiva e dose efetiva coletiva, uma vez que estas grandezas levam em conta o risco de possíveis efeitos biológicos associados a exposição à radiação ionizante. Para determinar os valores dessas grandezas, os diversos setores censitários das regiões selecionadas foram mapeados e avaliados individualmente, de acordo com a taxa de dose média absorvida no ar e número de habitantes de cada setor. Utilizou-se um sistema de detecção da radiação gama baseado em cintilador plástico e GPS, que possibilitaram a medida da taxa de dose absorvida no ar a cada segundo, para as coordenadas geográficas selecionadas. Embora este sistema tenha sido desenvolvido para a detecção de fontes artificiais perdidas, ou seja, não tem o objetivo principal de fazer medidas dosimétricas da radiação gama natural, teve seus modos de leitura calibrados e comparados com resultados da literatura (com uma incerteza média de 8,7 %). Dos resultados obtidos, dos mapeamentos realizados nas regiões consideradas, as médias anuais da dose efetiva e dose efetiva coletiva para ambientes ao ar livre foram encontradas com os valores 0,034 ± 0,004 mSv/ano e 25,62 ± 9,25 homem.mSv/ano respectivamente, sendo a primeira cerca da metade da média mundial da dose efetiva recomendada pela UNSCEAR. As médias obtidas são baixas quando comparadas às encontradas em outros estudos sobre dose de radiação gama ao ar livre no estado de São Paulo e em outras regiões do território brasileiro (sendo, de 1,7 até 5,6 vezes menor). / Gamma environmental radiation measurements were done for some urban regions in the city of Ribeirão Preto-SP, in order to contribute with this knowledge on the annual ambiental values of this type of radiation in the São Paulo state and in the Brazilian territory. The quantities chosen were effective dose and effective collective dose, once they take into account the possible biologic damage related to the ionizing radiation energy absorbed. For the assessments of these quantities, selected census sectors were initially mapped out, regarding their average absorbed dose in air and the number of inhabitants living in each one of the sectors. The detector system used is based on an organic plastic scintillator and a GPS, that allows to obtain the absorbed dose rate for each second and their respective geographic coordinates. Even though this system was developed to detect missing artificial gamma sources, in other words, its main function is not for dosimetric measurements, both display modes were calibrated in exposure rate (R/h) and absorbed dose rate (Gy/h) and their readings were compared to results from the literature (with an average uncertainty of 8.7%). From the mapping results of the selected regions, the annual average effective dose and effective collective dose for outdoor environments were obtained, respectively as 0.034 ± 0.004 mSv/year and 25.62 ± 9.25 man.mSv/year. The value for the first average dose is lower (about half) than the worldwide average value published by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), also lower than the values from other regions in the national territory, regarding the gamma dose rate in outdoor environments (from 1.7 up to 5.6 times lower).
25

Avaliação das doses efetivas e efetivas coletivas da radiação natural na região de Ribeirão Preto (SP) / Effective Dose and Collective Effective Dose Evaluation from Natural Radiation in the Region of Ribeirão Preto (SP)

Fernanda Cavalcante 29 March 2012 (has links)
Medidas da radiação gama ambiental foram feitas em algumas regiões da cidade de Ribeirão Preto-SP, de forma a contribuir para o conhecimento acerca dos níveis desse tipo de radiação no estado de São Paulo e no território brasileiro. Escolheu-se determinar as médias anuais de dose efetiva e dose efetiva coletiva, uma vez que estas grandezas levam em conta o risco de possíveis efeitos biológicos associados a exposição à radiação ionizante. Para determinar os valores dessas grandezas, os diversos setores censitários das regiões selecionadas foram mapeados e avaliados individualmente, de acordo com a taxa de dose média absorvida no ar e número de habitantes de cada setor. Utilizou-se um sistema de detecção da radiação gama baseado em cintilador plástico e GPS, que possibilitaram a medida da taxa de dose absorvida no ar a cada segundo, para as coordenadas geográficas selecionadas. Embora este sistema tenha sido desenvolvido para a detecção de fontes artificiais perdidas, ou seja, não tem o objetivo principal de fazer medidas dosimétricas da radiação gama natural, teve seus modos de leitura calibrados e comparados com resultados da literatura (com uma incerteza média de 8,7 %). Dos resultados obtidos, dos mapeamentos realizados nas regiões consideradas, as médias anuais da dose efetiva e dose efetiva coletiva para ambientes ao ar livre foram encontradas com os valores 0,034 ± 0,004 mSv/ano e 25,62 ± 9,25 homem.mSv/ano respectivamente, sendo a primeira cerca da metade da média mundial da dose efetiva recomendada pela UNSCEAR. As médias obtidas são baixas quando comparadas às encontradas em outros estudos sobre dose de radiação gama ao ar livre no estado de São Paulo e em outras regiões do território brasileiro (sendo, de 1,7 até 5,6 vezes menor). / Gamma environmental radiation measurements were done for some urban regions in the city of Ribeirão Preto-SP, in order to contribute with this knowledge on the annual ambiental values of this type of radiation in the São Paulo state and in the Brazilian territory. The quantities chosen were effective dose and effective collective dose, once they take into account the possible biologic damage related to the ionizing radiation energy absorbed. For the assessments of these quantities, selected census sectors were initially mapped out, regarding their average absorbed dose in air and the number of inhabitants living in each one of the sectors. The detector system used is based on an organic plastic scintillator and a GPS, that allows to obtain the absorbed dose rate for each second and their respective geographic coordinates. Even though this system was developed to detect missing artificial gamma sources, in other words, its main function is not for dosimetric measurements, both display modes were calibrated in exposure rate (R/h) and absorbed dose rate (Gy/h) and their readings were compared to results from the literature (with an average uncertainty of 8.7%). From the mapping results of the selected regions, the annual average effective dose and effective collective dose for outdoor environments were obtained, respectively as 0.034 ± 0.004 mSv/year and 25.62 ± 9.25 man.mSv/year. The value for the first average dose is lower (about half) than the worldwide average value published by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), also lower than the values from other regions in the national territory, regarding the gamma dose rate in outdoor environments (from 1.7 up to 5.6 times lower).

Page generated in 0.3231 seconds