• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização hidrogeológica e critérios para construção de poços na Bacia Sedimentar Paraíba

DANTAS, José Wellington Stanford 31 January 2012 (has links)
Submitted by Danielle Karla Martins Silva (danielle.martins@ufpe.br) on 2015-03-11T17:58:02Z No. of bitstreams: 2 DISSERTAÇÃO José Wellington stanford Dantas.pdf: 7648763 bytes, checksum: 89d94ec267f78931f8fa8f796abbdb01 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-11T17:58:02Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO José Wellington stanford Dantas.pdf: 7648763 bytes, checksum: 89d94ec267f78931f8fa8f796abbdb01 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012 / Este trabalho tem o objetivo de contribuir com informações que possam colaborar com o processo de controle, proteção e utilização racional das águas subterrâneas dos Aquíferos Beberibe, Barreiras e Aluvionar do Rio Mumbaba, dentro dos limites da Região Metropolitana de João Pessoa. A pesquisa consistiu na realização de testes de bombeamento em diversos poços para a determinação de parâmetros hidrodinâmicos desses aquíferos e avaliação das possíveis interferências ocasionadas pela falta de planejamento da locação dos poços. A metodologia utilizada consistiu de testes de produção para verificar a eficiência dos poços e de testes de aquífero para determinar a sua capacidade produtiva. Na caracterização hidrodinâmica dos poços e aquíferos, recorreu-se a ensaios de vazão (teste de aquífero e de vazão), bem como a pesquisa bibliográfica e inventário de poços tubulares. Os resultados obtidos demonstram aspectos relevantes quanto à hidrodinâmica e à geometria dos Aquíferos estudados, agregando conhecimentos para melhor orientar a perfuração e a elaboração de projetos de poços tubulares e contribuindo para o planejamento, o gerenciamento, a conservação e a proteção das águas subterrâneas desses aquíferos e de outros da Região. Outro resultado importante observado foi que o histórico dos níveis estáticos de todos os poços estudados se manteve constante, demonstrando a eficiência da recarga, apesar dos fatores antrópicos adversos.
2

Boas práticas de fabricação e o processo de validação no desenvolvimento e produção de kit imunodiagnóstico / Good manufacturing practices and the validation process in the development and production of an Immunodiagnostic kit

Meneghisse, Claudia Solimeo 05 November 2007 (has links)
A produção de kits para diagnóstico in vitro deve ser feita seguindo-se a legislação vigente de Boas Práticas de Fabricação e Controle (BPF). O objetivo deste trabalho foi elaborar um procedimento para desenvolvimento, produção e validação de um produto para diagnóstico in vitro, de acordo com a legislação vigente. Adotamos como modelo um kit imunoenzimático para Doença de Chagas. Dentro dos requisitos de BPF, a validação é uma etapa importante, pois tem por objetivos, dentre outros: auxiliar no estabelecimento de procedimentos de produção e controle de qualidade, avaliar desvios e dimensionar possíveis erros, avaliar o desempenho quanto à utilidade médica dos resultados obtidos e estabelecer condições ideais de uso. No estabelecimento dos requisitos para validação devem-se considerar as características do método utilizado, a utilidade clínica e diagnóstica dos resultados e as condições de uso do kit. Os parâmetros para validação devem ser definidos considerando a finalidade do uso do produto. Os resultados obtidos em três lotes pilotos demonstraram que o kit pode ser utilizado tanto com soro como com plasma, as amostras podem ser congeladas e descongeladas antes do uso por até 5 ciclos, o índice de concordância com kit comercial é de 0,9 (ótimo) e o kit mantém-se estável por pelo menos 7 dias à 37ºC, o que neste trabalho foi equivalente a pelo menos um ano na sua condição ideal de armazenamento de 2 a 8ºC. Além disso, o kit apresentou 100% de sensibilidade, 99% de especificidade, com coeficiente de variação 15,2% tanto na repetitividade como na reprodutibilidade de amostras positivas. Quanto à análise de interferentes, amostras hemolisadas e a presença de fator reumatóide podem interferir nos resultados e anticorpos anti-Leishmania na amostra podem dar reação cruzada. Conclui-se que o procedimento elaborado e o kit desenvolvido e validado atenderam aos requisitos pré-estabelecidos, de acordo com as regras de BPF vigentes. / The production of an in vitro diagnostic kit should be done following current Good Manufacturing Practices (GMP). The objective of this work was to establish a procedure for the development, production and validation of an in vitro diagnostic product in accordance with current regulations governing Medical Devices. An enzyme-linked immunoassay kit for Chagas\' disease was used as a model. Validation is a very important step contained within GMP requirements. Validation provides documented evidence that processes and product batches are consistent, it aids in the establishment of production and quality control procedures, evaluate deviations and identify possible mistakes, evaluate the performance and medical usefulness of the product based on the obtained results, and establish ideal conditions of use and storage. In order to establish validation requirements for product development, it is necessary to consider the characteristics of the assay method, the clinical and diagnostic usefulness of the results and the conditions of use of the kit. The parameters for validation should be defined considering the purpose of the use of the product. In the case of this Chagas assay, results obtained in three pilot lots demonstrated that the kit could be used with both serum and plasma, samples could be frozen and thawed before use for up to 5 cycles. The agreement index when compared with a commercially licensed kit is 0,9 (optimum correlation). The kit remained stable for at least 7 days at 37ºC, which is equivalent to at least one year stability in its ideal storage condition of 2 to 8ºC. The kit presented 100% sensitivity and 99% specificity, with variation coefficient of 15,2% for both repeatability and reproducibility of the positive samples. Interference analysis indicated that: hemolyzed samples and the presence of reumathoid factor could interfere with test results. Antibodies anti-Leishmania in the test sample can cross react with T. cruzi proteins. In conclusion: the established procedure for development and validation of chagas kit, and the actual developed and validated kit are in accordance with pre-established current GMP requirements.
3

Boas práticas de fabricação e o processo de validação no desenvolvimento e produção de kit imunodiagnóstico / Good manufacturing practices and the validation process in the development and production of an Immunodiagnostic kit

Claudia Solimeo Meneghisse 05 November 2007 (has links)
A produção de kits para diagnóstico in vitro deve ser feita seguindo-se a legislação vigente de Boas Práticas de Fabricação e Controle (BPF). O objetivo deste trabalho foi elaborar um procedimento para desenvolvimento, produção e validação de um produto para diagnóstico in vitro, de acordo com a legislação vigente. Adotamos como modelo um kit imunoenzimático para Doença de Chagas. Dentro dos requisitos de BPF, a validação é uma etapa importante, pois tem por objetivos, dentre outros: auxiliar no estabelecimento de procedimentos de produção e controle de qualidade, avaliar desvios e dimensionar possíveis erros, avaliar o desempenho quanto à utilidade médica dos resultados obtidos e estabelecer condições ideais de uso. No estabelecimento dos requisitos para validação devem-se considerar as características do método utilizado, a utilidade clínica e diagnóstica dos resultados e as condições de uso do kit. Os parâmetros para validação devem ser definidos considerando a finalidade do uso do produto. Os resultados obtidos em três lotes pilotos demonstraram que o kit pode ser utilizado tanto com soro como com plasma, as amostras podem ser congeladas e descongeladas antes do uso por até 5 ciclos, o índice de concordância com kit comercial é de 0,9 (ótimo) e o kit mantém-se estável por pelo menos 7 dias à 37ºC, o que neste trabalho foi equivalente a pelo menos um ano na sua condição ideal de armazenamento de 2 a 8ºC. Além disso, o kit apresentou 100% de sensibilidade, 99% de especificidade, com coeficiente de variação 15,2% tanto na repetitividade como na reprodutibilidade de amostras positivas. Quanto à análise de interferentes, amostras hemolisadas e a presença de fator reumatóide podem interferir nos resultados e anticorpos anti-Leishmania na amostra podem dar reação cruzada. Conclui-se que o procedimento elaborado e o kit desenvolvido e validado atenderam aos requisitos pré-estabelecidos, de acordo com as regras de BPF vigentes. / The production of an in vitro diagnostic kit should be done following current Good Manufacturing Practices (GMP). The objective of this work was to establish a procedure for the development, production and validation of an in vitro diagnostic product in accordance with current regulations governing Medical Devices. An enzyme-linked immunoassay kit for Chagas\' disease was used as a model. Validation is a very important step contained within GMP requirements. Validation provides documented evidence that processes and product batches are consistent, it aids in the establishment of production and quality control procedures, evaluate deviations and identify possible mistakes, evaluate the performance and medical usefulness of the product based on the obtained results, and establish ideal conditions of use and storage. In order to establish validation requirements for product development, it is necessary to consider the characteristics of the assay method, the clinical and diagnostic usefulness of the results and the conditions of use of the kit. The parameters for validation should be defined considering the purpose of the use of the product. In the case of this Chagas assay, results obtained in three pilot lots demonstrated that the kit could be used with both serum and plasma, samples could be frozen and thawed before use for up to 5 cycles. The agreement index when compared with a commercially licensed kit is 0,9 (optimum correlation). The kit remained stable for at least 7 days at 37ºC, which is equivalent to at least one year stability in its ideal storage condition of 2 to 8ºC. The kit presented 100% sensitivity and 99% specificity, with variation coefficient of 15,2% for both repeatability and reproducibility of the positive samples. Interference analysis indicated that: hemolyzed samples and the presence of reumathoid factor could interfere with test results. Antibodies anti-Leishmania in the test sample can cross react with T. cruzi proteins. In conclusion: the established procedure for development and validation of chagas kit, and the actual developed and validated kit are in accordance with pre-established current GMP requirements.

Page generated in 0.0528 seconds