Spelling suggestions: "subject:"bthermal compression"" "subject:"bthermal 8compression""
1 |
An Evaluation and Redesign of a Thermal Compression EvaporatorDay, Benjamin Marc 15 May 2009 (has links)
Evaporators separate liquids from solutions. For maximum efficiency, designers reduce the temperature difference between the heating and heated media using multiple-stage evaporators. This efficiency requires increased size and bulk. A vendor claimed its thermal compression evaporator achieved high efficiency with only two stages. It did not function as claimed. This project investigated the evaporator's design to identify its problems and propose an alternative design with a minimized footprint. The analysis showed theoretical flaws and design weaknesses in the evaporator, including violation of the first law of thermodynamics. An alternative thermal compressor design was created through computational fluid dynamics using spreadsheet methods developed in house, aided by the software product FLUENT. Detailed component sizing was done using the software product HYSYS. The proposed redesign achieved four to one efficiency with two stage thermal compression, using one half of the space of a traditional system of similar performance.
|
2 |
THERMAL DEGRADATION OF AMINES FOR CO<sub>2</sub> CAPTUREHuang, Quanzhen 01 January 2015 (has links)
In the selection of candidates for CO2 absorption, solvent thermal degradation has become a general concern due to the significant impact on operational cost and the intention to use thermal compression from high temperature stripping to minimize the overall process energy. In this research, the impact of flue gas contaminants on Monoethanolamine (MEA) thermal degradation was investigated at elevated temperatures consistent with those in the CO2 stripper. Nitrite, fly ash, sulfate and thiosulfate were each added to 5.0 M MEA and the contaminant-containing MEA solutions were degraded at 125 °C, 135 °C and 145 °C. MEA degrades significantly more in the presence of nitrite (5000 ppm) than MEA alone at the same amine molar concentration for all three temperatures. MEA degradation activation energy of MEA-nitrite solution is approximately one-seventh of that of MEA solution without nitrite. Fly ash was observed to inhibit nitrite-induced MEA degradation and greatly increase the MEA degradation activation energy of MEA-nitrite solution. Fly ash, sodium sulfate and sodium thiosulfate by themselves were not shown to impact MEA thermal degradation rate.
Sodium salts of glycine, sarcosine, alanine and ß-alanine were thermally degraded at 125 °C, 135 °C and 145 °C, respectively, to discover the structural reasons for their thermal stability. These four amino acids have enhanced thermal degradation rates compared to MEA. The stability order for amino acid salts tested to date is: sarcosinate > alaninate > ß-alaninate. Calculated activation energies for the degradation processes are lower than that of MEA. ß-Alaninate (ß-Ala) thermal degradation generates ß-Ala dimer (major degradation product), ß-Ala dimer carbamate and tetrahydro-1,3-oxazin-6-one.
Functional groups, amine orders and steric effect were investigated for their impact on amine thermal degradation. Primary amines with chain structures showed a thermal stability trend as diamine > alkanolamine > amino acid salt. For alknolamine and diamine structural isomers, the primary amines are more stable than the secondary amines. Steric hindrance around the amine group plays a global positive role in protecting amines against thermal degradation.
|
3 |
Development Of An Activated Carbon+ HFC 134a Adsorption Refrigeration SystemNitinkumar, D Banker 12 1900 (has links)
The demands facing the refrigeration industry are minimal usage of conventional energy sources for compression and avoidance of ozone depleting substances. One of the approaches to combat these issues is the use of thermally driven solid sorption compression with non-ozone depleting refrigerant. In this context, the research work presented in this thesis is devoted to a comprehensive thermodynamic analysis and development of a laboratory model of an activated carbon+ HFC 134a adsorption refrigeration system. The cooling load catered to by the laboratory model is 2-5 W, mainly for thermal management of electronics.
A complete thermodynamic analysis is carried out for the desorption temperatures varying from 75 to 90 oC, evaporating temperatures from -20 to 15oC and adsorption/condensing temperatures from 25 to 40 oC. A program on MatLab platform is developed for theoretical modeling. A new concept of thermal compression uptake efficiency (u) which is analogous to volumetric efficiency of a positive displacement compressor is introduced to consider the effect of void volume. The thesis also covers an investigation of two-stage and hybrid (thermal+ mechanical) cycle compression systems. It is possible to identify the conditions under which a two-stage gives a better performance than a single-stage one. It also shows that hybrid cycle system gives the best performance and saves ~40% of power compared to operation under the same conditions run with a single-stage mechanical compression refrigeration system.
A heat transfer analysis of the thermal compressor is carried out to evaluate non-uniformities in bed temperature. As a part of it, the thermal conductivity of the bed under adsorbed state has been calculated.
A laboratory model of activated carbon+ HFC 134a adsorption refrigeration system is fabricated to meet a 2-5 Watts cooling load based on the results from theoretical calculations. Experimental results show a fair match in the trends for the COP with analysis. The main aim of the research was to examine how effective the adsorption refrigeration system is in reducing the temperature rise of the heater used to simulate the electronic component. The heater that would have stabilized at 81, 97, 103 and 112 oC without any cooling for heat inputs of 3, 4, 4.4 and 4.9 W, respectively, would attain a cyclic steady state around 24, 26, 28, 31 oC. The influence of cycle time on the performance of the systems is also investigated.
It is concluded that an activated carbon+ HFC 134a adsorption refrigeration system can be a good supplement to conventional compression refrigeration systems. In situations where heat recovery imminent this system could be a good choice. For waste heat recovery and suppression of infrared signatures of electronic components, it is ideally suited where COP becomes immaterial.
|
4 |
Development And Investigation of Two-Stage Silica Gel + Water Adsorption Cooling Cum Desalination SystemMitra, Sourav January 2016 (has links) (PDF)
The present research work caters to two important needs of rural India: i) desalination of subsoil/coastal brackish water and ii) basic refrigeration for short term preservations of agro-produce, medicines etc. Fortunately, such places are blessed with abundant solar insolation and/or low grade thermal energy (< 100°C) is available which may be tapped for this purpose instead of relying solely on grid electricity. Both the objectives of desalination and cooling are realized by evaporating brackish water at a low pressure (~1 kPa) and thermally compressing the water vapour to a higher pressure before condensing it. Adsorption route is chosen for compression where silica gel is the adsorbent and water to be desalinated as the refrigerant. The objective of this study is to develop a laboratory prototype of a two-stage adsorption cooling cum desalination system driven by low grade heat source. The entire system is air-cooled which is necessitated by non-availability of heat exchange grade cooling water.
Initially various experimental and theoretical studies are carried out for characterizing silica gel + water pair which is fundamental to the system design. RD type silica gel is used in this study due to its high uptake capabilities. The uptakes for this adsorption pair at various pressure and temperature conditions are measured using a specially designed isothermal adsorber cell connected to an evaporator. Subsequently, a modelling study of adsorption kinetics is performed for a monolayer of silica gel in order to estimate the adsorption time scale. This time scale is used as an input for the scaling analysis of columnar packed silica gel bed. The scaling analysis showed that the thermal diffusion time scale limits the adsorption process. It also showed that for a given thermal length scale, the bed has a unique vapour flow length scale beyond which the adsorption phenomenon gets limited due to pressure drop. The scaling results are validated by simulation studies.
A shell-and-tube heat exchanger is chosen for the adsorber which closely mimics the columnar silica gel packing studied in scaling analysis. The heat exchanger is designed for radial entry of vapour. A modelling study is performed on ANSYS® Fluent platform for optimising the tube pitch by minimising the overall thermal capacitance of the bed. The shell diameter is determined for this tube pitch based on the vapour flow length criterion established through scaling. To experimentally study the effect of pressure drop on bed performance, the radial entry of vapour is closed for 1 bed/stage (out of the 4 beds/stage) enforcing the vapour to flow along the longer axial dimension.
The system is generously instrumented for precise measurements and control over the various experimental parameters. For the functioning of the adsorber system, various vapour valves and water (heat transfer fluid) valves need to be operated in a cyclical and synchronized manner. Individual components are fitted with pressure, temperature and water flow sensors. The entire operation and data acquisition for the adsorption system has been automated using National Instruments® (NI) PXIe controller executing an in-house developed code written on NI Labview® platform. To simulate solar/waste heat input, multiple electrical heaters are used in this study and a constant temperature bath is used to simulate the cooling load at the evaporator.
Prior to conducting experiments a 4-bed lumped dynamic model is developed based on the design data of the system to simulate the two-stage system performance for various input conditions. The study helped to optimise the performance of a two-stage system. The study also compares the two-stage and single-stage system performance for various ambient temperatures (25–40°C). The study revealed that for pressure lifts higher than 5 kPa a two-stage system is preferable.
A detailed experimental study is conducted on the developed prototype by operating it in various conditions namely 2, 3 and 4–bed modes for single and two-stage operations; with 1.0–1.7 kPa evaporator pressures, half cycle time varying between 1200–3000s and source temperature in the range of 75–85°C. The system is operated indoors during summer conditions wherein the ambient temperature is found to be 36±1°C which is significantly higher than the design point of 25°C. This resulted in lower than expected throughput; however, the system performance variation is qualitatively similar to as predicted by the lumped model. A comparison between the experimental and simulated bed temperature revealed that the thermal wave during the switching of hot/cold water plays a significant role causing a large deviation from the simulation results. A comparative study is carried out between the beds with radial vapour flow to that with axial flow and the results validate the scaling criterion. Experimental results also depict that two-stage operation is favourable when the pressure lift required is larger than 5 kPa. Such large pressure lift is encountered when air-cooling is used in a tropical country like India.
|
5 |
Technologie výroby uhlíkových kompozitů lisováním za tepla / Technology of manufacturing of carbon fibre composites by hot formingPřikryl, Pavel January 2019 (has links)
This master’s thesis deals with the composite materials and especially aims on the carbon and glass fiber composites. It points out different composition types and manufacturing methods which reflect in the different mechanical properties, final quality of the manufactured part and also in the manufacturing time. The practical part includes two particular manufacturing methods using prepregs, one cured in an autoclave and one by hot compression moulding.
|
Page generated in 0.0616 seconds