Spelling suggestions: "subject:"thermocouples"" "subject:"hermocouples""
1 |
Measurement of low velocity by means of thermocouples.Boulos, Roland Nicolas. January 1970 (has links)
No description available.
|
2 |
A dual-junction thermocouple probe for compensated temperature measurement in reacting flows /Scattergood, Thomas R., January 1992 (has links)
Thesis (M.S.)--Virginia Polytechnic Institute and State University, 1992. / Vita. Abstract. Includes bibliographical references (leaves 100-101). Also available via the Internet.
|
3 |
Measurement of low velocity by means of thermocouples.Boulos, Roland Nicolas. January 1970 (has links)
No description available.
|
4 |
Materials for thermocouplesScervini, Michele January 2012 (has links)
No description available.
|
5 |
Application des capteurs thermiques implantés pour la détection du profil de gelée dans la cuve d'électrolyse /Boily, Pascal, January 2001 (has links)
Mémoire (M.Eng.)--Université du Québec à Chicoutimi, 2001. / Document électronique également accessible en format PDF. CaQCU
|
6 |
DESIGN AND DEVELOPMENT OF HIGHLY ACCURATE TEMPERATURE MEASUREMENT INSTRUMENTATION FOR USE IN HOSTILE ENVIRONMENTHanna, Ghassan Faraj, 1957- January 1986 (has links)
No description available.
|
7 |
An experimental and analytical analysis of a heated thermocouple flow deviceFranz, Scott C. 09 February 1994 (has links)
The topic of this thesis is to discuss an
investigation made for a fluid velocity measuring device.
The OSU thermal hydraulic testing facility is interested
in using a small probe to measure fluid velocities in the
annular region of a model nuclear reactor vessel. A
heater with a thermocouple embedded into the center of
the heated region was considered for this application.
The philosophy of using such a device is as follows.
The temperature of the heater would be monitored closely.
Power fed to the heater would be modulated to keep the
temperature of the heater constant. The flow of water
passing across the heater would draw more or less heat
from the heater. The power used can then be related
directly to the velocity of the water.
Data for this type of experiment was taken in the
summer of 1992. A mathematical model to describe the
velocity probe behavior was developed to examine this
type of application in different situations. The data
was used to test the adequacy of the model.
Analysis of the experimental data show this system
is good for measuring steady state systems but is
sluggish during large changes in system flow velocity.
Results from the numerical model showed that it is has
good results predicting steady state data but exhibits
difficulty in reproducing hysteresis effects. / Graduation date: 1994
|
8 |
Design, fabrication, packaging and testing of thin film thermocouples for boiling studiesSinha, Nipun 02 June 2009 (has links)
Boiling is the most efficient form of heat transfer. Thermo-fluidic
transport mechanisms at different length and time scales govern the nature
of boiling. This study was conducted to enhance the understanding of the
surface temperature variations and fluctuations during boiling.
Microfabricated thin film thermocouples were used in this study.
The main aim of this study was to develop a repeatable procedure for
fabrication of thin film thermocouples and to test them by measuring surface
temperatures during various boiling regimes. Since thin film thermocouples
are known to provide reliable measurements at very fast response rates,
they were selected for this study. Small temperature fluctuations at high
sampling rates were studied in boiling experiments conducted using PF-5060
as the boiling medium. An experimental apparatus was fabricated for
conducting these experiments and it contained a viewing chamber whichblock for sensing the temperature during boiling on its surface. The small
size of these thermocouples was another big advantage as they were
expected to cause minimal interference to the temperature distribution and
the transport phenomenon during boiling.
This thesis reports the design evolution of the thermocouples
according to the need of packaging and describes the fabrication process with
sufficient detail so that it can be easily reproduced given the same facilities
and environment. The results of testing show that they can be used for
monitoring and analyzing surface temperature variations and fluctuations
during various boiling regimes with better temporal resolution.
housed the copper block used for providing the heat for boiling. The
substrate with thin film thermocouples was placed on top of this copper block for sensing the temperature during boiling on its surface. The small
size of these thermocouples was another big advantage as they were
expected to cause minimal interference to the temperature distribution and
the transport phenomenon during boiling.
This thesis reports the design evolution of the thermocouples
according to the need of packaging and describes the fabrication process with
sufficient detail so that it can be easily reproduced given the same facilities
and environment. The results of testing show that they can be used for
monitoring and analyzing surface temperature variations and fluctuations
during various boiling regimes with better temporal resolution.
|
9 |
The correlation length of temperature fluctuations measured in air using thermocouplesKulkarni, Rohan A. January 2005 (has links)
Thesis (M.S.)--State University of New York at Binghamton, Department or Electrical and Computer Engineering, 2005. / Includes bibliographical references (p. 37).
|
10 |
The influence of method of junction formation and heat treatment on the electromotive force produced by a thermocoupleReynolds, Elbert Brunner, January 1957 (has links)
Thesis (Ph. D.)--University of Wisconsin--Madison, 1957. / Typescript. Abstracted in Dissertation abstracts, v. 17 (1957) no. 8, p. 1724-1725. Vita. eContent provider-neutral record in process. Description based on print version record.
|
Page generated in 0.0648 seconds