• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação das tomografias computadorizadas de Raios-X e Gama na análise de Solo Simulado

FONSECA, Alexandra Carolina Gomes da 18 July 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-09-28T19:45:09Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Alexandra Carolina Gomes da Fonseca.pdf: 5722261 bytes, checksum: aac23d8838fdb0e78947a6d85d46b1fb (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-11-20T22:57:58Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Alexandra Carolina Gomes da Fonseca.pdf: 5722261 bytes, checksum: aac23d8838fdb0e78947a6d85d46b1fb (MD5) / Made available in DSpace on 2018-11-20T22:57:58Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Alexandra Carolina Gomes da Fonseca.pdf: 5722261 bytes, checksum: aac23d8838fdb0e78947a6d85d46b1fb (MD5) Previous issue date: 2017-07-18 / CAPES / A aplicação das duas tomografias teve como objetivo o estudo do comportamento do feixe de Raios – X em um fantom de solo tropical, após a filtração adicional e operando em intervalos de tensões entre 100 kV a 225kV. Para esse estudo foram utilizadas duas metodologias amplamente difundidas, que formaram uma metodologia única para a caracterização de materiais minerais do solo. Os equipamentos utilizados foram um micro - CT de Raios – X e um tomógrafo industrial de Raios Gama. Além da parte experimental, o estudo contou com uma fase simulada com os softwares XCOM e SpekCalC, essa fase foi de suma importância porque serviu de referência para as análises dos dados com as duas tomografias. As medições para avaliação da qualidade do feixe foram realizadas com software SpekCalC, as mesmas foram realizadas utilizando os mesmos parâmetros da fase de medidas do tomógrafo de Raios – X, os dados de saída analisados foram camada semi-redutora, energia média, energia efetiva e coeficiente de homogeneidade. Com o tomógrafo de Raios gama foi encontrado dado de intensidade relativa para os materiais puros, e a partir deles foram obtidos os valores de coeficiente de atenuação e densidade dos materiais. Com a técnica de atenuação de Raios – X foram realizadas medidas no fantom do solo e obtidos valores da atenuação de Hounsfield. A junção das metodologias mostrou que a boa resolução de densidade da tomografia de Raios gama foi de suma importância ao longo do estudo, porque indicou as melhorias da fase de construção do fantom, além de indicar os ajustes necessários para fase de medidas. Além da boa resolução temporal e espacial da tomografia de Raios – X, que detém um menor tempo de escaneamento e uma capacidade maior de detalhamento de materiais com dimensões muito pequenas ou particuladas (como os minerais utilizados) devido a sua resolução espacial. / The application of the two tomographies had the objective of studying the behavior of the X - ray beam in a tropical soil phantom, after additional filtration and operating in voltage ranges between 100 kV and 225 kV. For this study, two widely used methodologies were used which formed a unique methodology for the characterization of soil mineral materials. The equipment used was a micro - CT of X - rays and an industrial tomograph of gamma rays. In addition to the experimental part, the study had a simulated phase with the XCOM and SpekCalC softwares this phase was of great importance because it served as reference for the analysis of the data with the two tomographies. Measurements for beam quality evaluation were performed using SpekCalC software, which were performed using the same parameters as the X-ray tomograph measurements, the output data analyzed were semi-red, medium energy, effective energy and coefficient of homogeneity. With the gamma ray tomography, relative intensity data were obtained for the pure materials, and from them the values of the attenuation coefficient and density of the materials were obtained. With the X-ray attenuation technique, measurements were made on soil phantom and Hounsfield attenuation values were obtained. The combination of methodologies showed that the good resolution of gamma ray tomography was of paramount importance during the study because it indicated the improvements of the phantom construction phase, besides indicating the necessary adjustments for the measurement phase. In addition to the good temporal and spatial resolution of X - ray tomography, which has a shorter scanning time and a greater capacity for detailing materials with very small or particulate dimensions (such as the minerals used) due to their spatial resolution.
2

Simulação por meio do código MCNPX de tomografia gama e validação com dados experimentais

GUEDES, Karlos André Negri 14 January 2016 (has links)
Submitted by Irene Nascimento (irene.kessia@ufpe.br) on 2017-06-09T18:11:57Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Dissertação - final.pdf: 1733080 bytes, checksum: f7cb6d19b01ccf4cefdfe6261cb2a5eb (MD5) / Made available in DSpace on 2017-06-09T18:11:57Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Dissertação - final.pdf: 1733080 bytes, checksum: f7cb6d19b01ccf4cefdfe6261cb2a5eb (MD5) Previous issue date: 2016-01-14 / Capes / Este trabalho apresenta simulações de Monte Carlo com objeto com forma de meia-lua, densidade e material conhecidos. Foi colocado dentro de um tubo de aço como arranjo de teste para simulação pelo código MCNPX, a fim de ser validada pelas medidas em experimentos estáticos de transmissão de raios gama e com comparação com dados teóricos. O MCNPX requer uma geometria definida para cada trajetória de fótons. Isto oferece empecilhos para o uso do código em simulação de tomografia. A solução desse problema foi escrever um programa para criar os arquivos de entrada para cada trajetória. Trabalhando nesta sequência, foi criado um banco de dados para organização da grande quantidade de dados gerados. A instalação experimental utiliza um único par fonte-detector, com fonte radioativa isotópica de Césio-137 e o detector de Nal (Tl) de cintilação acoplado a um analisador de multicanal. A análise de erros foi feita com a métrica do RMSE para avaliação da qualidade das simulações. As simulações foram validadas pelos dados experimentais e também pelos dados analíticos com erros satisfatórios segundo a métrica utilizada. / This work presents Monte Carlo simulations with object shaped like a half moon with density and material knowns. It was placed inside a steel tube as a test arrangement for simulating the MCNPX code, for validation by static experiments measurement of gamma ray transmission and compared with theoretical data. The MCNPX requires a geometry defined for each photon trajectory. This offers trammels to use the code for tomography simulation. The solution of this problem was developing a program to create input files for each trajectory. Working in this sequence, a database was created to organize large amount of data has been generated. The experimental setup uses a single source-detector pair, with a radioactive isotope Cesium source 137 and the detector NaI (Tl) scintillation coupled to a multichannel analyzer. The error analysis was made with the RMSE metric for evaluating the quality of the simulations. The simulations were validated by experimental data and also by comparison with theoretical data with satisfactory errors according to the metric used.

Page generated in 0.0636 seconds