• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 522
  • 314
  • 129
  • 76
  • 51
  • 7
  • Tagged with
  • 1083
  • 470
  • 254
  • 195
  • 171
  • 149
  • 131
  • 126
  • 120
  • 116
  • 97
  • 90
  • 89
  • 87
  • 86
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Temporospatial characteristics of error correction /

Fiehler, Katja. January 2004 (has links)
Zugl.: Leipzig, University, Diss., 2004.
142

Entwicklung eines Detektors für die hochauflösende Positronen-Emissions-Tomographie basierend auf Lutetium-Oxyorthosilikat-Szintillatoren, Lawinen-Photodioden-Matrizen, integrierter Elektronik und Doppellagenauslese

Pichler, Bernd-Jürgen. January 2001 (has links) (PDF)
München, Techn. Univ., Diss., 2001.
143

Hoch auflösende zweidimensionale SEEING-NMR an Aluminium- und Kupfer-Systemen verschiedener Geometrien

Hesse, Kathrin. Unknown Date (has links) (PDF)
Universiẗat, Diss., 2002--Dortmund.
144

Optische Tomographie durch Auswertung der spektralen Modulation von Weißlichtinterferenz

Stiller, Henning. Unknown Date (has links) (PDF)
Universiẗat, Diss., 2005--Hamburg. / Erscheinungsjahr an der Haupttitelstelle: 2004.
145

Three-dimensional facial measurement by portrait holography and texture based focus detection

Frey, Susanne. Unknown Date (has links)
University, Diss., 2005--Düsseldorf.
146

MRT-Myokarduntersuchungen zur Vitalität und Perfusion mit P792 im Vergleich zu Gd-DOTA an Schweinen nach Induktion eines akuten Herzinfarktes

Kaufels, Nicola. January 1900 (has links)
Freie Universiẗat, Diss., 2005--Berlin. / Dateiformat: zip, Dateien im PDF-Format. Erscheinungsjahr an der Haupttitelstelle: 2005.
147

Kernspintomographische Untersuchungen nach Obliteration der Stirnhöhlen mit autogenem Fettgewebe /

Sengstock, Reinhard. January 2000 (has links)
Thesis (doctoral)--Universität, Marburg, 2000.
148

Imagerie micro-onde en milieu biologique : application au diagnostic médical.

Kom, Martin, January 1900 (has links)
Th. 3e cycle--Électronique--Grenoble--I.N.P, 1981. N°: D3 144.
149

Localized growth and characterization of silicon nanowires / Croissance localisée et caractérisation de nanofils de silicium

Xu, Tao 25 September 2009 (has links)
Les nanofils de silicium semblent très prometteurs pour utilisation comme éléments d'assemblage des composants à l'échelle nanométrique grâce à leur compatibilité avec la technologie conventionnelle du silicium. Ce travail de thèse se focalise sur la croissance épitaxialle et la caractérisation de nanofils de silicium. Dans la première partie, les nanofils de silicium sont fabriqués par la méthode Vapeur-liquide-Solide (VLS) à partir de catalyseurs d'or, en utilisant deux techniques: dépôt chimique en phase vapeur (CVD) et épitaxie par jets moléculaire (MBE). Les catalyseurs d'or sont déposés sur le substrat de Si (111) en ultravidel pour avoir un meilleur contrôle de leur distribution. La morphologie et la direction de croissance de nanofils ont été contrôlées en ajustant les paramètres de croissance. De plus, l'orientation de nanofils dans la direction <111> favorise l'intégration de nanofils dans les composants, alors que les dopants peuvent être incorporés en utilisant les gaz appropriés. Dans la deuxième partie, nous avons réussi à observer les structures atomiques de la surface de nanofils orientés <111> par microscopie à l'effet tunnel (STM) à basse température. Ensuite, les mécanismes physiques concernant l'origine de la morphologie de nanofils ont été étudiés En plus de l'analyse de la surface de nanofils, la tomographie pal" sonde atomique (TAP) a été utilisée pour caractériser la distribution des impuretés dans le volume de nanofils de silicium dopés au bore. Enfin, les résultats ont été comparés avec les conductivités mesurées sur les nanofils individuels. / Silicon nanowires are of interest for use as building blocks in the: bottom-up assembly of nanoscale devices due to their compatibility with conventional silicon technology. This thesis focuses on the epitaxial growth and characterization of silicon nanowires. ln the first part, we have investigated the gold islandassisted Vapour-Liquid-Solid (VLS) silicon nanowire growth using Chemical Vapour Deposition (CVD) and Molecular Bearn Epitaxy (MBE) techniques. The gold islands were deposited in Ultra High Vacuum (UHV) on Si (Ill) substrate to get a better control of their distribution. The morphology and growth direction of nanowires can be controlled by regulating growth conditions. Moreov(:r, the controlled <Ill> orientation can favour the integration of silicon nanowires into devices, while dopants can be incorporated by using appropriate gas. ln the second part, we have succeeded to observe the atomic structures of the <lll>-Si nanowire faceted sidewalls by scanning tunnelling microscopy (STM) at low temperature. Then, the physical mechanisms at the origin of the nanowire morphology have been discussed. ln addition to the surface analysis, three-dimensional atom probe tomography (APT) characterizations were performed to study the impurity distribution in the volume of boron-doped silicon nanowires. Finally, such results were compared to the conductivities of single nanowires measured.
150

Étude et calibration d’un hydrophone embarqué sur un flotteur dérivant - application à la sismologie / Study and calibration of a hydrophone mounted on a drifting float - seismological application

Joubert, Cécile 18 May 2015 (has links)
Dans ce travail, nous proposons une étude générale des hydrophones, leur fonctionnement suivant le principe de la piézoélectricité, les éléments les constituant ainsi que les brevets et les hydrophones existants. Nous modélisons les courbes de sensibilité à la réception et à l'émission avec le logiciel COMSOL que nous comparons avec des hydrophones en notre possession. Avec ces modèles, nous proposons le design d'un hydrophone potentiel, large bande, viable à de grandes immersions (>6000 m). Nous testons deux nouvelles méthodes de calibration d'hydrophone à basses fréquences (< 2 Hz) que nous appliquons aux hydrophones des flotteurs MERMAID. Dans la méthode «dynamique», la réponse de l'hydrophone est étudiée suite à l'application d'une brève surpression (1000 Pa avec tτ < 1 s), réalisée par le déplacement vertical de l'hydrophone dans l'eau. La méthode «statique» permet d'étudier la réponse du système d'acquisition complet. L'hydrophone est placé dans un caisson étanche dans lequel une surpression est générée par l'ajout d'une colonne d'eau placée au-dessus. Nous déterminons les pôles et zéros de la chaîne d'acquisition des flotteurs. La correction des sismogrammes enregistrés par trois flotteurs MERMAID déployés en mer Méditerranée, nous permet d'estimer la pression générée par le séisme de Barcelonnette à environ 400 Pa (7 avril 2014, Mw = 4,8). Nous validons les données acquises par les MERMAID dans une étude sismologique. Nous étudions les données de six mois d'enregistrements par les trois flotteurs déployés en mer Ligure, développons un protocole de pré-traitement des données que nous validons avec une étude tomographique. / In this work, we propose a general study of hydrophones focusing on their operation, based on the piezoelectric principle, the different elements that compose them and the available hydrophones and patents. We model reception and emission sensibility curves with COMSOL software and compare with hydrophones at our disposal, allowing us to qualitatively estimate the sensitivity. We propose a design for a potential broadband hydrophone, viable at large depths (> 6000 m). We test new methods of hydrophone calibration at low frequencies (< 2 Hz) and apply them to the MERMAID floats hydrophone. In the «dynamic» method, the hydrophone response is studied with a brief pressure variation (1000 Pa with tτ < 1 s), performed by a winch, which vertically moves the hydrophone into water. The «static» method allows us to study the full system response. The hydrophone is placed in a calibration chamber in which a pressure variation is performed with an additional water column. We have determined poles and zeros applicable to the MERMAID. The correction of seismograms recorded by three MERMAID floats, deployed in the Mediterranean Sea, allows us to estimate the pressure variation produced by the Barcelonnette earthquake which is around 400 Pa (April 7, 2014, , Mw = 4,8). We validate the data acquired by the MERMAID in a seismological study. We study data of six months of acquisition of the three floats deployed in the Ligurian Basin, develop a preprocessing method of these data and validate with a tomographic study.

Page generated in 0.052 seconds