• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

ANÁLISE MICROSCÓPICA E DA RUGOSIDADE DE SUPERFÍCIE DE FIOS ORTODÔNTICOS ESTÉTICOS, ANTES E APÓS DEFLEXÃO

Pedro, Adriana Correia 25 April 2011 (has links)
Made available in DSpace on 2016-08-03T16:31:17Z (GMT). No. of bitstreams: 1 Adriana Correia pag 1 - 30.pdf: 478369 bytes, checksum: ae6323176f9acdf91b9fe5c7217f35f3 (MD5) Previous issue date: 2011-04-25 / The aim of this study was evaluate surface topography of esthetic orthodontic wires, before and after three-point bending test. The sample consisted of 70 lenghts of wires 0,014 round section, 10 of which commercial brand assessed: Orthocosmetic Elastinol (Masel), Flexy Super Elastic Esthetic (Orthometric), InVu (TP Orthodontics) and ProForm Nitanium (Ortho Organizers) Teflon® coated NiTi wires; Optis (TP Orthodontics) a fiber-reinforced plastic orthodontic wire named FRP; Niticosmetic (Tecnident) epoxy resin-coated NiTi wire; and Nitinol SE (3M Unitek) uncoated NiTi wire, used as control group. Surface topography of each wire was measured with a contact stylus perfilometer and with optical microscope, before and after being submitted to deflection, on side force was applied and on the opposite side. Each wire was 3,1mm deflected, at a speed of 1mm/min, with a 5N load cell, at 36&#8304;C + 1&#8304;C. Three criteria variance analysis (p<0,05) showed significant difference between assessed wires and Tukey s test showed Optis wire (TP Orthodontics) had increased parameters Ra, Rt and Rz mean values, after deflection. Niticosmetic (Tecnident) wire had increased average roughness (Ra) values. InVu (TP Orthodontics) was the only wire that showed greater values of roughness, on the side force was applied. Visual analysis with optical microscopy revealed surface alterations in all esthetic wires evaluated, after three-point bending test, since coating delamination, observed in Orthocosmetic Elastinol and InVu wires, permanent risks on surface, as seen in Flexy Super Elastic Esthetic, Niticosmetic and ProForm Nitanium, and even incomplete fracture, as in Optis wire. This study concluded that Niticosmetic wire showed similar surface topography to uncoated NiTi wire, and the other esthetic wires assessed had greater roughness and visual surface alterations. / O objetivo deste estudo foi avaliar a topografia de superfície dos fios estéticos, antes e após teste de deflexão. A amostra foi composta por 70 corpos de prova de fios 0,014 redondos, sendo 10 de cada uma das marcas comerciais avaliadas: Orthocosmetic Elastinol (Masel), Flexy Super Elastic Esthetic (Orthometric), InVu (TP Orthodontics) e ProForm Nitanium (Ortho Organizers) fios de NiTi revestidos por Teflon®; Optis (TP Orthodontics) fio de resina reforçado por fibra de vidro ou FRP; Niticosmetic (Tecnident) fio de NiTi revestido por resina epoxídica; e Nitinol SE (3M Unitek) fio de NiTi superelástico, usado para controle. A topografia de superfície de cada fio foi avaliada por rugosímetro e por microscópio óptico, antes e após ser submetido a ensaio de deflexão, no lado em que a força foi aplicada e no lado oposto a este. Cada fio foi defletido em 3,1mm, a uma velocidade de 1mm/min, com célula de carga de 5N a 36&#8304;C + 1&#8304;C. A análise de variância a três critérios (p<0,05) mostrou diferença significante entre os fios e o teste de Tukey mostrou que o fio Optis (TP Orthodontics) apresentou aumento nos parâmetros de rugosidade Ra, Rt e Rz, após a deflexão. O fio Niticosmetic (Tecnident) apresentou aumento na rugosidade média (Ra). O fio InVu (TP Orthodontics) foi o único que mostrou aumento na rugosidade no lado em que a força foi aplicada. A análise visual por meio de microscopia óptica revelou alterações na superfície em todos os fios estéticos após o teste de deflexão, desde delaminações do revestimento, observadas nos fios Orthocosmetic Elastinol e InVu, riscos permanentes na superfície, como visto nos fios Flexy Super Elastic Esthetic, Niticosmetic e ProForm Nitanium, e até mesmo fratura incompleta, no fio Optis. Concluiu-se que o fio Niticosmetic apresentou topografia de superfície similar ao fio metálico, e os demais fios estéticos apresentaram maior rugosidade e alterações visuaisna superfície.
2

Medida de topografia de superfície usando a técnica de deslocamento de fase / Measurement of Surface Topography using the Phase Shift Technique.

Soga, Diogo 08 December 2000 (has links)
Neste trabalho, medimos o perfil 3D de superfícies (microtopografia) utilizando uma técnica de interferometria óptica: Phase-Shi,ftzng (Deslocamento de Fase). Utilizamos um interferômetro do tipo Twyman-Green para produzir fi.guras de interferência da superfície analisada. Essas imagens foram armazenadas usando-se uma câmera CCD ligada à um microcomputador. Para obter a microtopografia, calculamos o Mapa de Fase a partir das imagens digitalizadas usando um programa de microcomputador. Posteriormente um outro programa removeu a ambiguidade da função tangente (unwrapping), pela Técnica do Autômato Celular, usada no cáiculo do Mapa de Fase. Então efetuamos os cálculos para determinar a microtopografia da superfície. Depois fizemos a análise da microtopografia, levantando informações relevantes para a sua caracterização. Analisamos objetos com alta refletividade (espelhos planos e redes de Ronchi) e obtivemos bons resultados. Também comparamos alguns dos resultados obtidos com a técnica de Deslocamento de Fase com os resultados obtidos pela análise de Franjas de Igual Espessura. / In this work we measured the 3D profile of surfaces (microtopography) using a optical interferometric technique: Phase-Shifting. We used a interferometer of type Twyman-Green to produce interferograms from analyzed surface. These images was captured using a CCD camera that was linked to a microcomputer. To obtain a microtopography, we calculated the Phase Map using the digitalized images and a software of microcomputer. Then another program removed the wrapping of tangent fuction, using the Cellular-Automata Technique, that was used to calculate the Phase Map. So we calculated the microtopography of the surface. After we did the analyses of the microtopography, find out some important informations of its description. We studied objects with high reflectivity (plane mirrors and Ronchi ruting) and we obtained good results. Also we compared some results with that obtained by analyses of Fringes of Equal Thickness\'
3

Medida de topografia de superfície usando a técnica de deslocamento de fase / Measurement of Surface Topography using the Phase Shift Technique.

Diogo Soga 08 December 2000 (has links)
Neste trabalho, medimos o perfil 3D de superfícies (microtopografia) utilizando uma técnica de interferometria óptica: Phase-Shi,ftzng (Deslocamento de Fase). Utilizamos um interferômetro do tipo Twyman-Green para produzir fi.guras de interferência da superfície analisada. Essas imagens foram armazenadas usando-se uma câmera CCD ligada à um microcomputador. Para obter a microtopografia, calculamos o Mapa de Fase a partir das imagens digitalizadas usando um programa de microcomputador. Posteriormente um outro programa removeu a ambiguidade da função tangente (unwrapping), pela Técnica do Autômato Celular, usada no cáiculo do Mapa de Fase. Então efetuamos os cálculos para determinar a microtopografia da superfície. Depois fizemos a análise da microtopografia, levantando informações relevantes para a sua caracterização. Analisamos objetos com alta refletividade (espelhos planos e redes de Ronchi) e obtivemos bons resultados. Também comparamos alguns dos resultados obtidos com a técnica de Deslocamento de Fase com os resultados obtidos pela análise de Franjas de Igual Espessura. / In this work we measured the 3D profile of surfaces (microtopography) using a optical interferometric technique: Phase-Shifting. We used a interferometer of type Twyman-Green to produce interferograms from analyzed surface. These images was captured using a CCD camera that was linked to a microcomputer. To obtain a microtopography, we calculated the Phase Map using the digitalized images and a software of microcomputer. Then another program removed the wrapping of tangent fuction, using the Cellular-Automata Technique, that was used to calculate the Phase Map. So we calculated the microtopography of the surface. After we did the analyses of the microtopography, find out some important informations of its description. We studied objects with high reflectivity (plane mirrors and Ronchi ruting) and we obtained good results. Also we compared some results with that obtained by analyses of Fringes of Equal Thickness\'
4

Influência da natureza e topografia da superfície na micro-abrasão e micro-abrasão-corrosão / Influence of nature and surface topography on micro-abrasion and micro-abrasion-corrosion

Ardila, Miguel Angel Narvaez 06 September 2017 (has links)
CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / O trabalho tem como objetivo contribuir ao entendimento do efeito das caraterísticas superficiais no desgaste abrasivo com e sem efeito corrosivo. Utilizou-se o equipamento de micro-abrasão-corrosão desenvolvido no Laboratório de Tribologia e Materiais (LTM). Foi utilizado nos testes: amostras de aço inoxidável austenítico AISI 304, partículas abrasivas de sílica e velocidade de rotação de 150 rpm. Para a parte corrosiva foi usada solução eletrolítica com 1N de H2SO4. Para a influência da topografia de superfície do corpo de prova o aço AISI 304 foi preparado em lixas de carbeto de silício de granulometria #80 e #4000, e com disposições de lixamento perpendicular e paralelo com respeito ao sentido de rotação da esfera. Esferas de zircônia (Ø 25,4 mm) foram usadas como contra-corpos. Para avaliar a influência da natureza e evolução topográfica da superfície do contra-corpo usaram-se cinco contra-corpos esféricos (Ø 25,4 mm): um cerâmico (nitreto de silício, Si3N4), um metálico (aço AISI 52100) e três polímeros termoplásticos (polipropileno, PP, poliacetal, POM, e poliamida 6,6, PA 6,6); para os testes de micro-abrasão-corrosão foram usados um cerâmico (Si3N4) e um polímero termoplástico (PP). Foi acompanhada a evolução topográfica ao longo dos testes nos contra-corpos por meio de interferometria e perfilometría. O deslizamento das partículas abrasivas foi predominante nas calotas geradas em todos os testes realizados. A topografia de superfície do corpo e contra-corpo mostrou ter relação com a taxa de desgaste na micro-abrasão e micro-abrasão-corrosão. Topografia de superfície com parâmetros de rugosidade maiores apresentam maiores taxas de desgaste, tendo maior sensibilidade na micro-abrasão-corrosão. Atribuiu-se que, com maiores valores dos parâmetros de rugosidade, consegue-se maior efetividade no arraste e participação de partículas abrasivas no contato. / The aim of this work is to contribute to the understanding of the effect of surface characteristics on abrasive wear with and without corrosive effect. The micro-abrasion-corrosion apparatus developed at the Tribology and Materials Laboratory (LTM) was used. The following tests were used: AISI 304 austenitic stainless steel test specimens (body), silica abrasive particles and rotational speed of 150 rpm. For the corrosive analysis, an 1N H2SO4 electrolytic solution was used. For the influence of the surface topography of the specimen, the AISI 304 steel was grinded using silicon carbide (SiC) (#80 and # 4000), and tested with perpendicular and parallel arrangements with respect to the direction of rotation of the sphere. Zirconia balls (Ø 25.4 mm) were used as counter bodies. In order to analyze the influence of the nature and topographic evolution of the counter-body surface, five spherical counter bodies (Ø 25.4 mm) were used in the micro-abrasion tests: one ceramic (silicon nitride, Si3N4), one metal (AISI steel 52100) and three thermoplastic polymers (polypropylene, PP, polyacetal, POM and polyamide 6.6, PA 6.6); For the micro-abrasion-corrosion tests one ceramic (silicon nitride) and one thermoplastic polymer (PP) were used. The topographic evolution of the counter bodies was monitored along the tests through interferometry and profilometry. The grooving of the abrasive particles was predominant in the wear scars generated in all tests performed. The surface topographies of the body and counter-body showed to have relation with the wear rate in the micro-abrasion and micro-abrasion-corrosion tests. Higher roughness parameters induced higher wear rates, and show greater sensitivity in micro-abrasion-corrosion. It was attributed that higher values of the roughness parameters achieved greater effectiveness in the drag and participation of abrasive particles in the contact. / Tese (Doutorado)

Page generated in 0.0832 seconds