• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 5
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The effects of laterality on obstacle crossing performance in unilateral trans-tibial amputees

De Asha, Alan R., Buckley, John 02 March 2015 (has links)
yes / Background Unilateral trans-tibial amputees have bilaterally reduced toe clearance, and an increased risk of foot contact, while crossing obstacles compared to the able-bodied. While the able-bodied tend to lead with a ‘preferred’ limb it is equivocal whether amputees prefer to lead with the intact or prosthetic limb. This study determined the effects of laterality, compared to side of amputation, on amputees' obstacle crossing performance. To help understand why laterality could affect performance we also assessed knee proprioception for both limbs. Methods Foot placement and toe clearance parameters were recorded while nine amputees crossed obstacles of varying heights leading with both their intact and prosthetic limbs. Joint-position sense was also assessed. Participants self-reported which limb was their preferred (dominant) limb. Findings There were no significant differences in foot placements or toe clearance variability across lead-limb conditions. There were no significant differences in toe clearance between intact and prosthetic lead-limbs (p = 0.28) but toe clearance was significantly higher when amputees led with their preferred compared to non-preferred limb (p = 0.025). There was no difference in joint-position sense between the intact and residual knees (p = 0.34) but joint-position sense tended to be more accurate for the preferred, compared to non-preferred limb (p = 0.08). Interpretation Findings suggest that, despite the mechanical constraints imposed by use of a prosthesis, laterality may be as important in lower-limb amputees as it is in the able bodied. This suggests that amputees should be encouraged to cross obstacles leading with their preferred limb. / Engineering and Physical Sciences Research Council
2

Biomechanical adaptations of lower-limb amputee-gait : effects of the echelon hydraulically damped foot : segmental kinetic and kinematic responses to hydraulically damped prosthetic ankle-foot components in unilateral, trans-tibial amputees

De Asha, Alan Richard January 2013 (has links)
The aim of this thesis was to determine the biomechanical adaptations made by active unilateral trans-tibial amputees when they used a prosthesis incorporating a hydraulically-damped, articulating ankle-foot device compared to non-hydraulically attached devices. Kinematic and kinetic data were recorded while participants ambulated over a flat and level surface at their customary walking speeds and at speeds they perceived to be faster and slower using the hydraulic device and their habitual foot. Use of the hydraulic device resulted in increases in self-selected walking speeds with a simultaneous reduction in intact-limb work per meter travelled. Use of the device also attenuated inappropriate fluctuations in the centre-of-pressure trajectory beneath the prosthetic foot and facilitated increased residual-knee loading-response flexion and prosthetic-limb load bearing during stance. These changes occurred despite the hydraulic device absorbing more, and returning less, energy than the participants’ habitual ankle-foot devices. The changes were present across all walking speeds but were greatest at customary walking speeds. The findings suggest that a hydraulic ankle-foot device has mechanical benefits, during overground gait, for active unilateral trans-tibial amputees compared to other attachment methods. The findings also highlight that prosthetic ankle-foot device ‘performance’ can be evaluated using surrogate measures and without modelling an ‘ankle joint’ on the prosthetic limb.
3

The effects of walking speed on minimum toe clearance and on the temporal relationship between minimum clearance and peak swing-foot velocity in unilateral trans-tibial amputees

De Asha, Alan R., Buckley, John 04 1900 (has links)
yes / Background: Minimum toe clearance is a critical gait event because it coincides with peak forward velocity of the swing foot, and thus, there is an increased risk of tripping and falling. Trans-tibial amputees have increased risk of tripping compared to able-bodied individuals. Assessment of toe clearance during gait is thus clinically relevant. In able-bodied gait, minimum toe clearance increases with faster walking speeds, and it is widely reported that there is synchronicity between when peak swing-foot velocity and minimum toe clearance occur. There are no such studies involving lower-limb amputees. Objectives: To determine the effects of walking speed on minimum toe clearance and on the temporal relationship between clearance and peak swing-foot velocity in unilateral trans-tibial amputees. Study design: Cross-sectional. Methods: A total of 10 trans-tibial participants walked at slow, customary and fast speeds. Minimum toe clearance and the timings of minimum toe clearance and peak swing-foot velocity were determined and compared between intact and prosthetic sides. Results: Minimum toe clearance was reduced on the prosthetic side and, unlike on the intact side, did not increase with walking speed increase. Peak swing-foot velocity consistently occurred (~0.014 s) after point of minimum toe clearance on both limbs across all walking speeds, but there was no significant difference in the toe–ground clearance between the two events. Conclusion: The absence of speed related increases in minimum toe clearance on the prosthetic side suggests that speed related modulation of toe clearance for an intact limb typically occurs at the swing-limb ankle. The temporal consistency between peak foot velocity and minimum toe clearance on each limb suggests that swing-phase inter-segmental coordination is unaffected by trans-tibial amputation. Clinical relevance The lack of increase in minimum toe clearance on the prosthetic side at higher walking speeds may potentially increase risk of tripping. Findings indicate that determining the instant of peak swing-foot velocity will also consistently identify when/where minimum toe clearance occurs.
4

Biomechanics of ramp descent in unilateral trans-tibial amputees: Comparison of a microprocessor controlled foot with conventional ankle–foot mechanisms

Struchkov, Vasily, Buckley, John 05 December 2015 (has links)
Yes / Background Walking down slopes and/or over uneven terrain is problematic for unilateral trans-tibial amputees. Accordingly, ‘ankle’ devices have been added to some dynamic-response feet. This study determined whether use of a microprocessor controlled passive-articulating hydraulic ankle–foot device improved the gait biomechanics of ramp descent in comparison to conventional ankle–foot mechanisms. Methods Nine active unilateral trans-tibial amputees repeatedly walked down a 5° ramp, using a hydraulic ankle–foot with microprocessor active or inactive or using a comparable foot with rubber ball-joint (elastic) ‘ankle’ device. When inactive the hydraulic unit's resistances were those deemed to be optimum for level-ground walking, and when active, the plantar- and dorsi-flexion resistances switched to a ramp-descent mode. Residual limb kinematics, joints moments/powers and prosthetic foot power absorption/return were compared across ankle types using ANOVA. Findings Foot-flat was attained fastest with the elastic foot and second fastest with the active hydraulic foot (P < 0.001). Prosthetic shank single-support mean rotation velocity (p = 0.006), and the flexion (P < 0.001) and negative work done at the residual knee (P = 0.08) were reduced, and negative work done by the ankle–foot increased (P < 0.001) when using the active hydraulic compared to the other two ankle types. Interpretation The greater negative ‘ankle’ work done when using the active hydraulic compared to other two ankle types, explains why there was a corresponding reduction in flexion and negative work at the residual knee. These findings suggest that use of a microprocessor controlled hydraulic foot will reduce the biomechanical compensations used to walk down slopes.
5

Biomechanical adaptations of lower-limb amputee-gait: Effects of the echelon hydraulically damped foot. Segmental kinetic and kinematic responses to hydraulically damped prosthetic ankle-foot components in unilateral, trans-tibial amputees.

De Asha, Alan R. January 2013 (has links)
The aim of this thesis was to determine the biomechanical adaptations made by active unilateral trans-tibial amputees when they used a prosthesis incorporating a hydraulically-damped, articulating ankle-foot device compared to non-hydraulically attached devices. Kinematic and kinetic data were recorded while participants ambulated over a flat and level surface at their customary walking speeds and at speeds they perceived to be faster and slower using the hydraulic device and their habitual foot. Use of the hydraulic device resulted in increases in self-selected walking speeds with a simultaneous reduction in intact-limb work per meter travelled. Use of the device also attenuated inappropriate fluctuations in the centre-of-pressure trajectory beneath the prosthetic foot and facilitated increased residual-knee loading-response flexion and prosthetic-limb load bearing during stance. These changes occurred despite the hydraulic device absorbing more, and returning less, energy than the participants’ habitual ankle-foot devices. The changes were present across all walking speeds but were greatest at customary walking speeds. The findings suggest that a hydraulic ankle-foot device has mechanical benefits, during overground gait, for active unilateral trans-tibial amputees compared to other attachment methods. The findings also highlight that prosthetic ankle-foot device ‘performance’ can be evaluated using surrogate measures and without modelling an ‘ankle joint’ on the prosthetic limb.

Page generated in 0.0372 seconds