• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Conception réalisation et mise en oeuvre d'un scintillomètre : influence de la vapeur d'eau dans la bande 940nm / Designing and making a scintillometer : influence of water vapour in the 940nm band

Solignac, Pierre-Adrien 09 December 2009 (has links)
L'atmosphère et la surface terrestre interagissent en permanence par le biais des échanges d'énergie et de matière. Ces flux jouent un rôle important dans l'étude de l'hydrologie des surfaces ou de l'écologie terrestre, ou bien encore l'étude des phénomènes météorologiques et climatiques. En effet, ils représentent les conditions aux limites des différents compartiments du système Terre et la quantification de ces échanges à différentes échelles spatiales est indispensable pour les modèles de prévision. Les mesures de flux d'énergie sont très répandues pour des mesures très localisées, in situ et au sol. Cependant, peu d'instruments de mesures permettent d'obtenir des flux intégrés sur des distances de l'ordre de la centaine de mètres à quelques kilomètres, c'est-à-dire des distances correspondant à la représentativité des pixels des images satellitaires. On compte parmi eux les scintillomètres, instrument de mesure optique, permettant de calculer les flux intégrés de chaleur sensible à partir des mesures de paramètres caractérisant l'intensité turbulente de l'atmosphère tels que le paramètre de structure de l'indice de réfraction de l'air Cn². La présence de vapeur d'eau dans l'atmosphère peut cependant perturber le signal de ces instruments. L'objectif de ce travail est le développement et la mise en oeuvre d'un scintillomètre optique permettant de mettre en évidence la contribution de l'absorption par la vapeur d'eau sur les scintillations. Les études menées à partir du développement instrumental ne s'orienteront qu'autour de la bande d'absorption à 940nm, longueur d'onde d'émission de certains scintillomètres LAS (Large Aperture Scintillometer). Au début de ma thèse, un prototype de scintillomètre, type LAS, a été conçu de façon à maitriser complètement la technologie : partie optique électronique et le traitement du signal reçu. Celui-ci a ensuite été installé au-dessus d'un site de cultures dans les environs de Toulouse, au cours des années 2007 et 2008. Les résultats obtenus avec ce prototype ont permis d'optimiser le choix de la méthode de calcul H à partir du Cn², en fonction du rapport de Bowen (rapport du flux de chaleur sensible sur le flux de chaleur latente). Les variations de l'intensité lumineuse de l'onde, menant au Cn², sont principalement dues à des effets de réfraction et de dispersion, maissont aussi sensibles à l'absorption de la vapeur d'eau. Afin de quantifier l'influence de 'absorption sur le signal Cn², j'ai utilisé 2 approches : une première approche par filtrage numérique (‘Gabor Transform'), et une seconde, par méthode chromatique. Cette dernière a nécessité de modifier considérablement le système optique du prototype LAS. Les résultats obtenus expérimentalement montrent que la contribution de l'absorption à la mesure du Cn² est en moyenne assez faible, mais qu'elle peut prendre de forte valeur, principalement lors de faibles flux H. La quantification de l'absorption par méthode hromatique est pour l'instant limité au développement technique de l'instrument. / Atmosphere, soil and vegetation are in interactions by the bias of energetic or matter exchanges. This latters have an important impact on hydrology, ecology, meteorology. Actually, they represent the boundary conditions of the Earth-Atmosphere system. Then, the quantification of these exchanges or fluxes is necessary to understand large scales phenomena and to improve forecasting models. Numerous devices are able to quantify these fluxes at local scales, but few are available to measure them over kilometres, which mean at the resolution of remote sensing datas. Amongst them, we can notice the scintillometers that are able to calculate sensible heat fluxes over distances from hundred meters to few kilometres. Actually, these devices are sensitive to variations of the refractive index of air, mainly due to turbulent eddies, defined by the structure parameter of refractive index : Cn². However, this measurement can be altered by the presence of water vapour in the air. Thus, the aim of this work is to design and make a scintillometer which is able to quantify the water vapour contribution on the Cn² measurement. In this thesis, we will focus on this contribution in the 940nm band which is the wavelength of various scintillometers LAS (Large Aperture Scintillometers). At the beginning of my PhD thesis, un scintillometer prototype has been realised in order to master the technology : optics, electronics, signal processing…This latter has been set up over crops at a few kilometres from Toulouse, between 2007 and 2008. Thanks to the results of this scintillometer, we optimize the choice on the Cn² to H algorithm, according to the Bowen ratio ß (ratio of sensible to latent heat flux). Variations of the light beam, leading to the Cn², are mainly due to refraction and dispersion effect. However, absorption can be important. In order to quantify the contribution of absorption on the Cn², 2 methods are suggested : one based on signal processing aspect (Gabor filtering), and the second one on two wavelengths propagation. To realize this latter the optics and electronics of the device have been really modified. Results show that absorption contribution is small, but can be important for low H values. Finally, the quantification of absorption by two wavelengths approach is nowadays bounded to instrumental development.
2

Séparation aveugle de source : de l'instantané au convolutif / Blind source separation : from instantaneous to convolutive

Feng, Fangchen 29 September 2017 (has links)
La séparation aveugle de source consiste à estimer les signaux de sources uniquement à partir des mélanges observés. Le problème peut être séparé en deux catégories en fonction du modèle de mélange: mélanges instantanés, où le retard et la réverbération (effet multi-chemin) ne sont pas pris en compte, et des mélanges convolutives qui sont plus généraux mais plus compliqués. De plus, le bruit additif au niveaux des capteurs et le réglage sous-déterminé, où il y a moins de capteurs que les sources, rendent le problème encore plus difficile.Dans cette thèse, tout d'abord, nous avons étudié le lien entre deux méthodes existantes pour les mélanges instantanés: analyse des composants indépendants (ICA) et analyse des composant parcimonieux (SCA). Nous avons ensuite proposé une nouveau formulation qui fonctionne dans les cas déterminés et sous-déterminés, avec et sans bruit. Les évaluations numériques montrent l'avantage des approches proposées.Deuxièmement, la formulation proposés est généralisés pour les mélanges convolutifs avec des signaux de parole. En intégrant un nouveau modèle d'approximation, les algorithmes proposés fonctionnent mieux que les méthodes existantes, en particulier dans des scénarios bruyant et / ou de forte réverbération.Ensuite, on prend en compte la technique de décomposition morphologique et l'utilisation de parcimonie structurée qui conduit à des algorithmes qui peuvent mieux exploiter les structures des signaux audio. De telles approches sont testées pour des mélanges convolutifs sous-déterminés dans un scénario non-aveugle.Enfin, en bénéficiant du modèle NMF (factorisation en matrice non-négative), nous avons combiné l'hypothèse de faible-rang et de parcimonie et proposé de nouvelles approches pour les mélanges convolutifs sous-déterminés. Les expériences illustrent la bonne performance des algorithmes proposés pour les signaux de musique, en particulier dans des scénarios de forte réverbération. / Blind source separation (BSS) consists of estimating the source signals only from the observed mixtures. The problem can be divided into two categories according to the mixing model: instantaneous mixtures, where delay and reverberation (multi-path effect) are not taken into account, and convolutive mixtures which are more general but more complicated. Moreover, the additive noise at the sensor level and the underdetermined setting, where there are fewer sensors than the sources, make the problem even more difficult.In this thesis, we first studied the link between two existing methods for instantaneous mixtures: independent component analysis (ICA) and sparse component analysis (SCA). We then proposed a new formulation that works in both determined and underdetermined cases, with and without noise. Numerical evaluations show the advantage of the proposed approaches.Secondly, the proposed formulation is generalized for convolutive mixtures with speech signals. By integrating a new approximation model, the proposed algorithms work better than existing methods, especially in noisy and/or high reverberation scenarios.Then, we take into account the technique of morphological decomposition and the use of structured sparsity which leads to algorithms that can better exploit the structures of audio signals. Such approaches are tested for underdetermined convolutive mixtures in a non-blind scenario.At last, being benefited from the NMF model, we combined the low-rank and sparsity assumption and proposed new approaches for under-determined convolutive mixtures. The experiments illustrate the good performance of the proposed algorithms for music signals, especially in strong reverberation scenarios.

Page generated in 0.0746 seconds