1

Gestão da manutenção de transformadores de distribuição visando à qualidade no fornecimento de energia elétrica

CORRAL, Maria Filomena Brito do 14 November 2008 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-01-08T21:51:00Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_GestaoManutencaoTransformadores.pdf: 3483668 bytes, checksum: d1b2aaf5f5bf3bbf9ec75f4b1d4fe4c7 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-01-17T15:43:39Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_GestaoManutencaoTransformadores.pdf: 3483668 bytes, checksum: d1b2aaf5f5bf3bbf9ec75f4b1d4fe4c7 (MD5) / Made available in DSpace on 2013-01-17T15:43:39Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_GestaoManutencaoTransformadores.pdf: 3483668 bytes, checksum: d1b2aaf5f5bf3bbf9ec75f4b1d4fe4c7 (MD5) Previous issue date: 2008 / Este trabalho tem como objetivo a gestão eficiente da manutenção em transformadores, que se encontram operando na rede elétrica de distribuição, permitindo ações efetivas que preservem a qualidade de energia entregue ao consumidor, procurando atender deste modo os critérios estabelecidos pelo PRODIST – Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional. O método aplicado para atingir este objetivo é a criação de um sistema de informações, que permita ao gestor da área de manutenção da distribuição de uma rede elétrica, tomar decisões considerando as interrupções ocorridas, o impacto que causaram no valor do FEC - Freqüência Equivalente de Interrupção por Unidade Consumidora e no carregamento dos transformadores. Entende-se que com isso as medidas mitigadoras serão tomadas em tempo hábil, podendo preservar a qualidade do fornecimento. / This paper has the objective of showing the efficient management of the maintenance in power transformers that are operating in the electrical distribution grid, allowing effective actions which preserve the quality of the energy delivered to consumers, considering the criteria established in PRODIST – Electrical Energy Distribution Procedures in the Brazilian Electrical System. The applied method to reach this objective is the creation of an information system, which allows that the distribution maintenance manager to take decisions considering the occured interruptions and the impact caused in FEC – Equivalent Frequency of Interruptions for unit consumer and in loading of transformers. It is understood that the mitigation actions will be taken in sufficient time, being able to preserve the quality of the supply.
2

Estimação relativa de tempo de vida de transformadores de distribuição, considerando cargas não lineares / Relative estimation of distribution transformers lifetime, considering nonlinear loads

Santos, Adriano Machado dos 29 July 2014 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2015-11-18T18:03:32Z No. of bitstreams: 2 Dissertação - Adriano Machado dos Santos - 2014.pdf: 9004500 bytes, checksum: 8843f32793f823e988a7913fedb9b4ca (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-11-19T14:25:06Z (GMT) No. of bitstreams: 2 Dissertação - Adriano Machado dos Santos - 2014.pdf: 9004500 bytes, checksum: 8843f32793f823e988a7913fedb9b4ca (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-11-19T14:25:06Z (GMT). No. of bitstreams: 2 Dissertação - Adriano Machado dos Santos - 2014.pdf: 9004500 bytes, checksum: 8843f32793f823e988a7913fedb9b4ca (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-07-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Electricity customers’ devices, connected to the secondary distribution network linked to distribution transformers belonging to the electrical energy distributor, modernize every year. These devices usually consist of components capable of processing energy and produce distortion at the load current. Thus these devices are typified as non-linear load and its effects influence the operation of the distribution transformers with implications for its lifetime. Therefore, this work presents the study of the influence of non-sinusoidal signals (distorted signals) in the lifetime of distribution transformers. In this sense equations are presented that allows to calculate transformers losses, their operating temperatures and estimate the percentage loss of life. To obtain results a computer program was developed in the numerical programming platform MATLAB based on the presented mathematical model. The developed program is supplied by data obtained from field as well as laboratory measurements. Results are also obtained by simulations. The focus of this study is the distribution system of the urban perimeter of the city Goiânia-GO. / Os aparelhos pertencentes aos consumidores de energia elétrica, ligados à rede de distribuição secundária conectados em transformadores de distribuição da distribuidora de energia elétrica, se modernizam a cada ano. Os referidos aparelhos normalmente são constituídos por componentes capazes de processar a energia e produzir distorção na corrente de alimentação. Deste modo estes aparelhos são tipificados como carga não linear e seus efeitos influenciam o funcionamento dos transformadores de distribuição com implicações no seu tempo de vida. Assim sendo, este trabalho apresenta estudo da influência de sinais não senoidais (sinais distorcidos) no tempo de vida destes transformadores. Neste sentido é apresentado equacionamento que permite calcular as perdas do transformador, suas temperaturas de operação e estimar a perda de vida percentual. Para a obtenção de resultados foi desenvolvido um programa computacional na plataforma de programação numérica MATLAB com base no modelo matemático apresentado. O programa desenvolvido é suprido por dados obtidos através de medições em campo e também de laboratório. Resultados são obtidos também por realização de simulações. O foco deste estudo é o sistema de distribuição do perímetro urbano da cidade de Goiânia-GO.
3

OTIMIZAÇÃO DO PROJETO DE TRANSFORMADORES DE DISTRIBUIÇÃO QUE EMPREGAM NÚCLEO AMORFO E ÓLEO VEGETAL ISOLANTE. / DEVELOPMENT DISTRIBUTION TRANSFORMER HIGH EFFICIENCY AND LOW RATIO WEIGHT/POWER USING AMORPHOUS CORE AND INSULATING VEGETABLE OIL

Silva, Paulo Roberto da 27 August 2015 (has links)
This paper presents a methodology for optimizing the distribution transformers project, considering the capitalized cost, employing concurrently in your project amorphous core and insulating vegetable oil. The use of amorphous core technology provides a significant reduction of the load losses as the use of the insulating vegetable oil which is a non-toxic fluid and rapidly biodegradable when in contact with the environment, it allows increasing the machine's operating temperature . The use of these two materials have provided considerable percentage improvements in efficiency and cost / power compared to conventional distribution transformers manufactured. The methodology is aimed to create and select designs that have a lower total cost, namely the sum of the transformer manufacturing cost capitalized cost of losses during the useful life envisaged for the equipment. In addition, it presents the case study of a 75 kVA designed distribution transformer and manufactured with amorphous core and insulating vegetable oil, routine employed optimization (developed in VBA Excel), the theoretical results obtained from the optimized design and the experimental results. / Este trabalho apresenta uma metodologia de otimização do projeto de transformadores de distribuição, considerando o custo capitalizado, que empregam concomitantemente em seu projeto núcleo amorfos e óleo vegetal isolante. O emprego da tecnologia de núcleo amorfo proporciona significativa redução das perdas em vazio, enquanto a utilização do óleo vegetal isolante, que é um fluído não tóxico e de rápida biodegradação quando em contato com o meio ambiente, possibilita o aumento da temperatura de operação do equipamento. A utilização desses dois materiais propiciaram melhoras percentuais consideráveis na eficiência e na relação custo/potência em comparação aos transformadores de distribuição convencionalmente fabricados. A metodologia visa criar e selecionar projetos que tenham um menor custo total, ou seja, a soma do custo de fabricação do transformador com o custo capitalizado das perdas durante a vida útil considerada para o equipamento.Além disso, é apresentado o estudo de caso de um transformador de distribuição de 75 kVA projetado e fabricado com o núcleo amorfo e óleo vegetal isolante, a rotina de otimização empregada (desenvolvida em VBA Excel), os resultados teóricos obtidos a partir do projeto otimizado e os resultados experimentais.

Page generated in 0.094 seconds