• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 5
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 32
  • 15
  • 15
  • 11
  • 11
  • 11
  • 8
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de um sistema para análise da estabilidade transitória de sistemas de energia elétrica via redes neurais

Marchiori, Sandra Cristina [UNESP] 15 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-02-15Bitstream added on 2014-06-13T19:00:51Z : No. of bitstreams: 1 marchiori_sc_dr_ilha.pdf: 677796 bytes, checksum: ad2f3ed3c028a78d1986bdec4a061832 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Esta pesquisa apresenta uma metodologia para a análise da estabilidade transitória de primeira oscilação de sistemas de energia elétrica usando uma rede neural baseada na arquitetura ART (Adaptive Resonance Theory), designada rede neural ARTMAP Euclidiana. A margem de segurança (método da energia) é empregada como critério de análise de estabilidade transitória, considerando-se, na forma preliminar, o modelo clássico e defeitos tipo curto-circuito trifásico com saída de linha de transmissão. A metodologia proposta está concebida, ainda, com a possibilidade de se considerar modelos mais elaborados (e.g., o modelo de Park), se comparados ao modelo clássico. Esta alternativa pode se tornar exeqüível, por meio do uso de um segundo módulo neural e de um índice, para fins de treinamento, gerado considerando-se uma combinação, por exemplo, da margem de segurança (análise quantitativa / qualitativa com média precisão) e de informações fornecidas por processo de simulação (análise qualitativa com alta precisão). As arquiteturas ART apresentam as características de estabilidade e plasticidade, as quais são imprescindíveis para a realização do treinamento e execução da análise de forma rápida. A versão ARTMAP Euclidiana proporciona soluções mais precisas e mais rápidas, se comparada à configuração ARTMAP nebulosa. O funcionamento da rede é constituído por três fases principais: treinamento (ou aprendizado), análise e treinamento continuado. A realização da fase de treinamento requer uma grande quantidade de processamento, enquanto que a fase de análise é efetivada, praticamente, sem esforço computacional. Esta é, portanto, a principal justificativa para o uso de redes neurais para a resolução de problemas complexos que exigem soluções rápidas, como é o caso de aplicações em tempo real... / This work presents a methodology for transient stability analysis of first swing of electrical energy systems, using a neural network based on ART (Adaptive Resonance Theory), named Euclidean ARTMAP neural network. The security margin (energy method) is used as a criterion for transient stability analysis, considering, in the preliminary form, the classical model and faults like three-phase short-circuit with outage of a transmission line. The proposed methodology is conceived, even that, with the possibility to consider more elaborated models (e.g., the Park model), when compared to the classical model. This alternative can become executable, through the use of a second neural module and an index for training, generated considering a combination, for example, the security margin (quantitative / qualitative analysis with precision average) and information provided by simulation process (qualitative analysis with precision high). The ART neural network presents stability and plasticity characteristics, which are very important for realization of the training and analysis, executed in a very fast way. The Euclidean ARTMAP version gives more accurate solutions and more fast, when compared to the Fuzzy ARTMAP. The performance of neural network is constituted of three principal phases: training (or learning), analysis and continuous training. The training phase needs a great quantity of processing time for the realization, whereas the analysis phase is effectuated almost without computational effort. Therefore, this is the principal justification to use neural network for solving complex problems that need fast solutions, as the case of real time applications ...
2

Representação de linhas de transmissão, utilizando elementos discretos de circuitos, no domínio das fases

Silva, Rodrigo Cleber da [UNESP] 02 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-02Bitstream added on 2014-06-13T18:07:16Z : No. of bitstreams: 1 silva_rc_me_ilha.pdf: 1094479 bytes, checksum: 97b67533f29314983c7862339e30e9e6 (MD5) / PROPG - Programa de Pós-Graduação / Neste trabalho será mostrado o desenvolvimento de dois modelos de linhas de transmissão, baseados em elementos discretos de circuitos, que fornecem respostas diretamente no domínio do tempo e nas fases. Os dois modelos propostos partem da hipótese de que um pequeno segmento de linha de transmissão pode ser representado por um circuito . Hipótese esta já validada para linhas monofásicas por diversos autores, e que neste trabalho será utilizada para representar pequenos segmentos de linhas bifásicas e trifásicas. Deste modo, tais linhas serão representadas por uma grande quantidade de blocos (constituídos de elementos discretos de circuitos que representam um pequeno segmento de linha) conectados em cascata. No primeiro modelo proposto, válido para representar linhas idealmente transpostas, as fases de cada um dos pequenos segmentos de linha são separados em seus modos de propagação, e as correntes e tensões são calculadas no domínio modal. No entanto a conversão fase-modo-fase está inserida nas equações de estado que descrevem as correntes e tensões ao longo da linha, sendo que não há a necessidade do usuário do modelo conhecer a teoria de representação de linhas no domínio modal. Uma vez que o modelo não usa explicitamente o processo de decomposição modal, neste trabalho o mesmo será considerado como sendo um modelo desenvolvido no domínio das fases sem o uso explícito da teoria de decomposição modal. Este modelo pode ser utilizado para representar linhas que podem ter suas fases desacopladas por matrizes reais e invariáveis em relação à frequência. A representação de pequenos segmentos de linhas por elementos discretos de circuitos também foi aplicada em linhas bifásicas e trifásicas sem plano de simetria vertical. Neste caso, devido ao fato de que as matrizes... / This paper will show the development of two models of transmission lines, based on discrete circuit elements, which provide answers directly in the time domain and phase. The two proposed models start from the assumption that a small segment of transmission line can be represented by a -circuit, this hypothesis has already been validated for single-phase by several authors and this work will be used to represent small segments of lines biphasic and triphasic. Thus, these lines will be represented by a large number of blocks (consisting of discrete circuit elements that represent a small segment of the line) in cascade. In the first model, valid for ideally transposed lines represent the phases of each small line segments are separated into their modes of propagation and the currents and voltages are calculated in the modal domain. However the conversion phase-mode-phase is inserted into the state equations describing the currents and voltages along the line being that there is no need for the user the model to know representation theory of modal lines. Since the model does not explicitly use modal decomposition process, this paper it will be considered to be a model developed in the field of the phases without the explicit use of modal decomposition theory. This model can be used to represent lines that may have decoupled phases for real matrices and invariant with respect to frequency. The representation of small line segments by discrete circuit elements has also been applied in biphasic and triphasic lines without vertical symmetry plane. In this case, due to the fact that the matrices that separate line in their modes of propagation are not real and invariant with respect to frequency, the model was developed directly in the field of the phases without the use of modal decomposition matrices
3

Desenvolvimento de um sistema para análise da estabilidade transitória de sistemas de energia elétrica via redes neurais /

Marchiori, Sandra Cristina. January 2006 (has links)
Orientador: Carlos Roberto Minussi / Banca: Antonio Padilha Feltrin / Banca: Maria do Carmo G. da Silveira / Banca: João Onofre Pereira Pinto / Banca: Arlan Luiz Bettiol / Resumo: Esta pesquisa apresenta uma metodologia para a análise da estabilidade transitória de primeira oscilação de sistemas de energia elétrica usando uma rede neural baseada na arquitetura ART (Adaptive Resonance Theory), designada rede neural ARTMAP Euclidiana. A margem de segurança (método da energia) é empregada como critério de análise de estabilidade transitória, considerando-se, na forma preliminar, o modelo clássico e defeitos tipo curto-circuito trifásico com saída de linha de transmissão. A metodologia proposta está concebida, ainda, com a possibilidade de se considerar modelos mais elaborados (e.g., o modelo de Park), se comparados ao modelo clássico. Esta alternativa pode se tornar exeqüível, por meio do uso de um segundo módulo neural e de um índice, para fins de treinamento, gerado considerando-se uma combinação, por exemplo, da margem de segurança (análise quantitativa / qualitativa com média precisão) e de informações fornecidas por processo de simulação (análise qualitativa com alta precisão). As arquiteturas ART apresentam as características de estabilidade e plasticidade, as quais são imprescindíveis para a realização do treinamento e execução da análise de forma rápida. A versão ARTMAP Euclidiana proporciona soluções mais precisas e mais rápidas, se comparada à configuração ARTMAP nebulosa. O funcionamento da rede é constituído por três fases principais: treinamento (ou aprendizado), análise e treinamento continuado. A realização da fase de treinamento requer uma grande quantidade de processamento, enquanto que a fase de análise é efetivada, praticamente, sem esforço computacional. Esta é, portanto, a principal justificativa para o uso de redes neurais para a resolução de problemas complexos que exigem soluções rápidas, como é o caso de aplicações em tempo real... / Abstract: This work presents a methodology for transient stability analysis of first swing of electrical energy systems, using a neural network based on ART (Adaptive Resonance Theory), named Euclidean ARTMAP neural network. The security margin (energy method) is used as a criterion for transient stability analysis, considering, in the preliminary form, the classical model and faults like three-phase short-circuit with outage of a transmission line. The proposed methodology is conceived, even that, with the possibility to consider more elaborated models (e.g., the Park model), when compared to the classical model. This alternative can become executable, through the use of a second neural module and an index for training, generated considering a combination, for example, the security margin (quantitative / qualitative analysis with precision average) and information provided by simulation process (qualitative analysis with precision high). The ART neural network presents stability and plasticity characteristics, which are very important for realization of the training and analysis, executed in a very fast way. The Euclidean ARTMAP version gives more accurate solutions and more fast, when compared to the Fuzzy ARTMAP. The performance of neural network is constituted of three principal phases: training (or learning), analysis and continuous training. The training phase needs a great quantity of processing time for the realization, whereas the analysis phase is effectuated almost without computational effort. Therefore, this is the principal justification to use neural network for solving complex problems that need fast solutions, as the case of real time applications ... / Doutor
4

Supervisão de tubulações por computador on-line

Silva, Reinaldo Alves da 30 August 1996 (has links)
Orientador: João Alexandre F. R. Pereira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-22T02:02:50Z (GMT). No. of bitstreams: 1 Silva_ReinaldoAlvesda_M.pdf: 2175418 bytes, checksum: 78c19688bd7822a4daae31a373f8bdfe (MD5) Previous issue date: 1996 / Resumo: Este trabalho estuda o comportamento da variação da perda de carga com o tempo obtido por um sistema de aquisição de dados em tempo real por microcomputador, interfaceando a sensores de medição da diferença de pressão ao longo da tubulação. O método escolhido para a realização destes trabalho foi o monitoramento de sinais característicos gerados por ondas negativas de pressão, que se propagam à velocidade do som no sentido a montante e a jusante do local do vazamento. Os experimentos foram realizados para diversas faixas do número de Reynolds, desde Reynolds 1000 até 12000, ou seja, o experimento cobriu do regime laminar até o turbulento. O sistema de aquisição de dados conta de quatro transdutores-transmissores de pressão, os quais medem a diferença de pressão em quatro diferentes pontos da tubulação, um multiplexador, que tem a função de escolher quais transdutores terão seus sinais transmitidos ao sinal analógico em digital, uma placa digital-digital, que, através do conversor D/D. atua na válvula solenóide simulando o vazamento em estudo e um microcomputador que recebe os dados do programa de aquisição de dados e os processam. Foi elaborado um software de filtragem dos dados amostrados, o qual minimiza ruídos provocados por operações normais em um processo de transporte de fluidos ...Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Not informed. / Mestrado / Sistemas de Processos Quimicos e Informatica / Mestre em Engenharia Química
5

Influencia do fator de atrito variavel na avaliação do escoamento transitorio em sistemas hidraulicos / It influences of the factor of variable attrition in the evaluation of the Transitory flowing in waterworks

Viaro, Vivien Luciane 04 April 2001 (has links)
Orientador: Edevar Luvizotto Jr / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-31T23:13:39Z (GMT). No. of bitstreams: 1 Viaro_VivienLuciane_M.pdf: 4505576 bytes, checksum: 18be75ce76921d4bee282a5330042a53 (MD5) Previous issue date: 2001 / Resumo: O transiente hidráulico é definido como a transição entre duas condições de escoamento permanente. Nessa transição a variação das grandezas associadas ao escoamento, principalmente a pressão, é importante no dimensionamento e exploração da instalação hidráulica. Os estudos das situações transitórias e das manobras que as provocaram, são fundamentais para se garantir a segurança operacional das instalações hidráulicas em geral. A análise do escoamento transitório em condutos forcados é feita com base nas equações da continuidade e da quantidade de movimento. Uma das imprecisões associadas à mo delação convencional está no uso de uma formulação quase-estática para o termo de atrito, a qual é válida somente para escoamento permanente. Este trabalho faz uma comparação entre os resultados obtidos em modelo fisico e os da modelação matemática, considerando ou não uma modelação especial para o termo de atrito transitório. Foram utilizados os modelos propostos por Brunone et. al. (1991) e Vardy et. al. (1993), na descrição do termo de atrito variável / Abstract: Hydraulic transient is defined as the transition between two permanent flowing conditions. In this transition, the greatness variation related to the flowing, mainly the pressure, is important to the measuring and exploration of hydraulic installation. Studies about transitory situations and the shuntings that caused them are fundamental to guarantee operational safety of the hydraulic plants in general. The transitory flowing analysis in forced conduits is based on equations of continuity and on the amount of movement. One of the imprecisions related to the conventional modeling is in using a almost-static formulation for the friction term, which is only valid for permanent flowing. This paper compares the results obtained from physical model with the one from the mathematical modeling, considering or not a special modeling for transitory friction term. The models used proposed by Brunone et. al. (1991) and Vardy et. al. (1993), to describe the variable friction term / Mestrado / Recursos Hidricos / Mestre em Engenharia Civil
6

Equivalentes de redes eléctricas para análisis de transitorios electromagnéticos

Benites Solis, Renso Alexander January 2014 (has links)
Publicación a texto completo no autorizada por el autor / Los equivalentes eléctricos para análisis de transitorios electromagnéticos convencionalmente se representan como un simple circuito equivalente basado en estudios de cortocircuito a frecuencia de la red, sin embargo ésta representación no es adecuada para estudios de transitorios electromagnéticos debido a la presencia de otras componentes de frecuencia que se presentan en eventos como: energización de líneas de transmisión, bancos de capacitores, reactores y transformadores, sobretensiones debido a descargas atmosféricas, recierres en líneas de transmisión, etc. La ocurrencia de estos eventos produce distorsión de las ondas de tensión y corriente, teniendo componentes de frecuencia desde las decenas de Hz hasta las decenas de kHz, por lo que se necesita un equivalente eléctrico que considere la respuesta del sistema en un cierto rango de frecuencias. En esta tesis se propone una metodología para obtener un equivalente que considere la dependencia de frecuencia del sistema a representar, comparado con el equivalente convencional obtenido de estudios de cortocircuito a frecuencia de la red, se analiza el caso de una energización de una línea de transmisión en alta tensión. / Tesis
7

Estudo dos efeitos da compensação série no desempenho transitório dos sistemas de energia elétrica sob o enfoque da energia /

Capellette, Renan Fernandes. January 2012 (has links)
Orientador: Laurence Duarte Colvara / Banca: Percival Bueno de Araujo / Banca: George Lauro Ribeiro de Brito / Resumo: Este trabalho analisa a influência do FACTS TCSC na função energia do sistema, mais especificamente na energia potencial. Também é abordada a influência da compensação dinâmica do TCSC na trajetória do sistema frente a uma grande perturbação, visando a melhoria da estabilidade transitória. A energia potencial é avaliada no espaço das posições angulares dos rotores das máquinas em torno de um ponto de equilíbrio estável levando em conta os efeitos da ação do TCSC. A trajetória do sistema é sobrepostas às curvas equipotenciais, e com isso é possível a avaliar os efeitos da compensação dinâmica do dispositivo nas mesmas. Através das simulações de dois sistemas testes, um sistema considerado de pequeno porte (Sistema de Quatro Máquinas) e outro de maior porte (New England) quando expostos a uma grande perturbação avalia-se a estabilidade de primeira oscilação com o intuito de determinar o tempo crítico de eliminação de uma falta no sistema. Posteriormente verifica-se a possibilidade de deslocar a trajetória do sistema com o propósito de que ela percorra um caminho mais íngreme na superfície da energia potencial, ou seja, idealmente que ela tenha orientação coincidente do gradiente da energia potencial, e analisa-se qual a influência da compensação série na energia potencial, com o intuito de obter tal direcionamento / Abstract: This dissertation examines the influence of TCSC FACTS on the power system energy function, specifically on the potential energy. The influence of dynamic compensation of the TCSC in the trajectory of the system after a major disruption in order to improve transient stability is also approached. The potential energy is evaluated in the space of machines rotor angular positions around stable equilibrium point taking into account effects of the TCSC action and the trajectory of the system is superimposed with equipotential curves and so it is possible to evaluate the effects of the dynamic compensation. Simulations are performed with two test systems, one being a (four machines system) and the other being the well-know New England system submitted to great disturbances. The stability of the first oscillation in order to determine the critical fault clearing time, is assessed. It is possible to change the system trajectory in order to traverse a more steeply path, i.e. ideally matching orientation with the potential energy gradient. The influence of series compensation in potential energy is taken into account, in order to conduct the system trajectory to the potential energy gradient orientation / Mestre
8

Representação de linhas de transmissão, utilizando elementos discretos de circuitos, no domínio das fases /

Silva, Rodrigo Cleber da. January 2012 (has links)
Orientador: Sérgio Kurokawa / Banca: Luiz Fernando Bovolato / Banca: Marcos de Araujo Paz / Resumo: Neste trabalho será mostrado o desenvolvimento de dois modelos de linhas de transmissão, baseados em elementos discretos de circuitos, que fornecem respostas diretamente no domínio do tempo e nas fases. Os dois modelos propostos partem da hipótese de que um pequeno segmento de linha de transmissão pode ser representado por um circuito . Hipótese esta já validada para linhas monofásicas por diversos autores, e que neste trabalho será utilizada para representar pequenos segmentos de linhas bifásicas e trifásicas. Deste modo, tais linhas serão representadas por uma grande quantidade de blocos (constituídos de elementos discretos de circuitos que representam um pequeno segmento de linha) conectados em cascata. No primeiro modelo proposto, válido para representar linhas idealmente transpostas, as fases de cada um dos pequenos segmentos de linha são separados em seus modos de propagação, e as correntes e tensões são calculadas no domínio modal. No entanto a conversão fase-modo-fase está inserida nas equações de estado que descrevem as correntes e tensões ao longo da linha, sendo que não há a necessidade do usuário do modelo conhecer a teoria de representação de linhas no domínio modal. Uma vez que o modelo não usa explicitamente o processo de decomposição modal, neste trabalho o mesmo será considerado como sendo um modelo desenvolvido no domínio das fases sem o uso explícito da teoria de decomposição modal. Este modelo pode ser utilizado para representar linhas que podem ter suas fases desacopladas por matrizes reais e invariáveis em relação à frequência. A representação de pequenos segmentos de linhas por elementos discretos de circuitos também foi aplicada em linhas bifásicas e trifásicas sem plano de simetria vertical. Neste caso, devido ao fato de que as matrizes... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This paper will show the development of two models of transmission lines, based on discrete circuit elements, which provide answers directly in the time domain and phase. The two proposed models start from the assumption that a small segment of transmission line can be represented by a -circuit, this hypothesis has already been validated for single-phase by several authors and this work will be used to represent small segments of lines biphasic and triphasic. Thus, these lines will be represented by a large number of blocks (consisting of discrete circuit elements that represent a small segment of the line) in cascade. In the first model, valid for ideally transposed lines represent the phases of each small line segments are separated into their modes of propagation and the currents and voltages are calculated in the modal domain. However the conversion phase-mode-phase is inserted into the state equations describing the currents and voltages along the line being that there is no need for the user the model to know representation theory of modal lines. Since the model does not explicitly use modal decomposition process, this paper it will be considered to be a model developed in the field of the phases without the explicit use of modal decomposition theory. This model can be used to represent lines that may have decoupled phases for real matrices and invariant with respect to frequency. The representation of small line segments by discrete circuit elements has also been applied in biphasic and triphasic lines without vertical symmetry plane. In this case, due to the fact that the matrices that separate line in their modes of propagation are not real and invariant with respect to frequency, the model was developed directly in the field of the phases without the use of modal decomposition matrices / Mestre
9

Caracterização e redução das oscilações espúrias resultantes da representação de linhas de transmissão por meio de elementos discretos de circuitos

Araújo, Anderson Ricardo Justo de [UNESP] 27 November 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-11-27. Added 1 bitstream(s) on 2015-06-18T12:47:22Z : No. of bitstreams: 1 000829819.pdf: 1940700 bytes, checksum: 6f56fa95a9e1b826bbe24a033df84b79 (MD5) / As soluções das equações diferenciais de uma linha de transmissão são geralmente de difícil obtenção devido a sua complexidade, especialmente quando os efeitos da frequência e solo são considerados. Considerando essa característica foram propostos dois modelos para estudar os transitórios eletromagnéticos de linha de transmissão monofásica. O primeiro é o modelo a parâmetros discretos que considera a linha de transmissão representada por uma cascata de circuitos π e as correntes e tensões ao longo da cascata são descritas por equações de estado e suas soluções são obtidas por métodos numéricos de integração desenvolvidos diretamente no domínio do tempo. O segundo é o modelo a parâmetros distribuídos que transforma as equações diferenciais no domínio do tempo em equações hiperbólicas algébricas no domínio da frequência e uma vez obtidas as soluções a, usando a Transformada Inversa de Laplace implementada numericamente, são obtidas as soluções no domínio do tempo. Observa-se a presença de oscilações espúrias nas simulações do modelo a parâmetros discretos quando a linha de transmissão é representada por cascatas de circuitos π. Neste trabalho serão analisadas as oscilações espúrias presentes nas simulações obtidas para uma linha de transmissão monofásica e trifásica de comprimento fixo e representada por distintas quantidades de circuitos π e submetida a diversas condições de energização. Será projetado um filtro passivo analógico inserido diretamente no modelo a parâmetros discretos para reduzir as oscilações espúrias nas simulações obtidas, tornando-o mais preciso e confiável para análise de transitórios eletromagnéticos em sistemas de potência / The solutions of differential equations of a transmission line are generally difficult to obtain due to the complexity of these equations. Considering this characteristics, two models have been proposed to study the electromagnetic transient in transmission line. The first model considers the discrete parameters to represents the transmission line using a cascade of π - circuit and the uses numerical integration methods developed directly in the time domain. The second model considers the distributed parameter of the transmission line. The differential equations in time domain are transformed to algebraic equations in the frequency domain and once obtained the solutions, using Inverse Laplace Transform implemented numerically, the solutions are obtained in the time domain. It was observed the presence of spurious oscillations when a transmission line is represented by a cascade of π-circuits. In this work the spurious oscillations will be analyzed using the simulations obtained from a single and three-phase transmission line. For these analyses, the transmission line is considered with fixed length and represented by different quantities of the π-circuits and the line energized by different voltage sources. It will be designed an analog low-pass filter inserted directly in the lumped parameters transmission line model to reduce spurious oscillations in the simulations, making it more accurate and reliable for the analysis in electromagnetic transients in power systems
10

Características de sistemas de transmissão tetrafásicos submetidos a transitórios lentos e rápidos

Brandt, Ivan Scherole [UNESP] 29 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-29Bitstream added on 2014-06-13T20:49:12Z : No. of bitstreams: 1 brandt_is_me_ilha.pdf: 996540 bytes, checksum: 97a4b2aa127103d8e81ea086dc41e70e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Entre tantas tecnologias alternativas desenvolvidas ao longo das últimas décadas, procurando aumentar a eficácia das técnicas convencionais ou propondo novas técnicas não convencionais na transmissão da energia elétrica a longas distâncias e lugares de difícil acesso, o estudo proposto apresenta alguns conceitos e características para sistemas de transmissão constituídos por quatro fases genéricas. O sistema de transmissão tetrafásico tem sido tema de diversos estudos e aplicações em alguns países da Europa e Ásia, apresentando algumas vantagens quando comparado ao sistema de transmissão trifásico convencional. Esse sistema pode ser facilmente integrado ao sistema trifásico por meio de transformadores, amplamente abordado por diversas referências bibliográficas. Nesse estudo foi realizado uma análise comparativa das possíveis sobretensões ocorridas nos domínios da frequência e do tempo entre os sistemas de transmissão trifásico e tetrafásico, avaliando as características elétricas e as respostas transitórias eletromagnética e impulsiva, mostrando novas vantagens sobre esta tecnologia, fornecendo uma avaliação completa sobre o tema / Among the many alternative technologies developed over the past decades, seeking to increase the effectiveness of conventional techniques or proposing new non-conventional techniques in the transmission of electricity over long distances and places of difficult access, the proposed study presents some concepts and features to transmission systems that are constituted of four generic phases. The four-phase transmission system has been subject of numerous studies and applications in some countries in Europe and Asia, presenting some advantages compared to the conventional three-phase transmission system. This system can be easily integrated into the three-phase system through transformers, thoroughly approached by several bibliographical references. In this study was made a comparative analysis of the possible overvoltages that occurred in the areas of frequency and time between the transmission systems of three-phase and four-phase, evaluating the electrical characteristics and the transient answers, electromagnetic and impulsive, showing new advantages over this technology, providing a complete evaluation of this issue

Page generated in 0.0469 seconds