• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do tratamento combinado de lixiviado de aterro sanitário e esgoto sanitário em sistema de lodos ativados / Evaluation of the combined treatment of landfill leachate and domestic sewage in activated sludge system

Albuquerque, Edilincon Martins de 05 June 2012 (has links)
Um dos principais resíduos gerados nos aterros é o lixiviado, que possui elevada concentração de matéria orgânica biodegradável e refratária e de matéria inorgânica, como nitrogênio amoniacal e metais pesados. O tratamento combinado de lixiviado com esgoto sanitário tem sido utilizado em algumas estações de tratamento de esgoto (ETE) brasileiras. No entanto, o processo ainda sofre vários questionamentos e incertezas, especialmente sobre os efeitos da adição do lixiviado sobre o sistema de tratamento. Nesse contexto, o presente trabalho visou avaliar a eficiência do tratamento combinado de lixiviado/esgoto em sistema de lodos ativados, em diferentes condições. Na primeira etapa desta pesquisa, foram realizados experimentos de tratabilidade em escala de bancada (regime de batelada) utilizando as proporções volumétricas de 0% (controle), 0,2%, 2% e 5% de lixiviado em diferentes condições experimentais. Dentre eles, o Experimento 2 (lixiviado pré-tratado por alcalinização e air stripping) se mostrou mais viável tecnicamente, alcançando eficiências de remoção da DBO, da DQO e do COD acima de 97, 82, 60%, respectivamente, até a proporção de 2% de lixiviado pré-tratado. Na segunda etapa da pesquisa, foi avaliada a tratabilidade utilizando reatores em escala piloto (regime contínuo) tratando esgoto sanitário com 2% (P1) e 0% (P2-controle) de lixiviado pré-tratado, com relação microrganismo-alimento de 0,22 kgDBO/kgSSV.dia, tempo de detenção hidráulica de 24 horas e idade do lodo de 20 dias. Os resultados indicaram viabilidade do tratamento nas condições estudadas com 2% de lixiviado pré-tratado, cujas eficiências médias de remoção da DBO, da DQO, do COD foram de 93, 84 e 60%, respectivamente. Esta pesquisa foi desenvolvida com apoio financeiro (Processo N° 2010/51955-2) da Fundação de Amparo à Pesquisa de São Paulo (FAPESP). / The leachate is one of the main wastes generated in landfills, it has a high concentration of biodegradable and refractory organic matter and inorganic matter, such as ammonia and heavy metals. The combined treatment of leachate with sewage has been used in various sewage treatment plants in Brazil. However, there are still many questions and uncertainties about the process, especially the effects of adding leachate on the treatment system. In this context, this study aimed at evaluating the efficiency of combined treatment of leachate/sewage in activated sludge under different conditions. In the first stage of this research, treatability experiments were carried out in a bench scale (SBR) using the volumetric proportions of 0% (control), 0.2%, 2% and 5% leachate under different experimental conditions. The Experiment 2 (leachate pretreated by alkalinization and air stripping) was more technically feasible, achieving efficiencies of removal of BOD, COD and DOC above 97, 82, 60%, respectively, until the proportion of 2% pre-treated leachate. In the second stage of the research was evaluated the treatability using pilot-scale reactors (continuous flow) for sewage treatment with 2% (P1) and 0% (P2-control) leachate pretreated. The operational parameters adopted were food-microorganism rate of 0.22 kgDBO/ kgSSV.d, hydraulic retention time of 24 hours and the sludge retention time of 20 days. The results indicated the viability of the combined treatment with 2% leached pretreated, whose average efficiency of removing BOD, COD, DOC were 93, 84 and 60% respectively. This research was developed with financial support (case No. 2010/2-51955) of Fundação de Amparo à Pesquisa de São Paulo (FAPESP).
2

Avaliação do tratamento combinado de lixiviado de aterro sanitário e esgoto sanitário em sistema de lodos ativados / Evaluation of the combined treatment of landfill leachate and domestic sewage in activated sludge system

Edilincon Martins de Albuquerque 05 June 2012 (has links)
Um dos principais resíduos gerados nos aterros é o lixiviado, que possui elevada concentração de matéria orgânica biodegradável e refratária e de matéria inorgânica, como nitrogênio amoniacal e metais pesados. O tratamento combinado de lixiviado com esgoto sanitário tem sido utilizado em algumas estações de tratamento de esgoto (ETE) brasileiras. No entanto, o processo ainda sofre vários questionamentos e incertezas, especialmente sobre os efeitos da adição do lixiviado sobre o sistema de tratamento. Nesse contexto, o presente trabalho visou avaliar a eficiência do tratamento combinado de lixiviado/esgoto em sistema de lodos ativados, em diferentes condições. Na primeira etapa desta pesquisa, foram realizados experimentos de tratabilidade em escala de bancada (regime de batelada) utilizando as proporções volumétricas de 0% (controle), 0,2%, 2% e 5% de lixiviado em diferentes condições experimentais. Dentre eles, o Experimento 2 (lixiviado pré-tratado por alcalinização e air stripping) se mostrou mais viável tecnicamente, alcançando eficiências de remoção da DBO, da DQO e do COD acima de 97, 82, 60%, respectivamente, até a proporção de 2% de lixiviado pré-tratado. Na segunda etapa da pesquisa, foi avaliada a tratabilidade utilizando reatores em escala piloto (regime contínuo) tratando esgoto sanitário com 2% (P1) e 0% (P2-controle) de lixiviado pré-tratado, com relação microrganismo-alimento de 0,22 kgDBO/kgSSV.dia, tempo de detenção hidráulica de 24 horas e idade do lodo de 20 dias. Os resultados indicaram viabilidade do tratamento nas condições estudadas com 2% de lixiviado pré-tratado, cujas eficiências médias de remoção da DBO, da DQO, do COD foram de 93, 84 e 60%, respectivamente. Esta pesquisa foi desenvolvida com apoio financeiro (Processo N° 2010/51955-2) da Fundação de Amparo à Pesquisa de São Paulo (FAPESP). / The leachate is one of the main wastes generated in landfills, it has a high concentration of biodegradable and refractory organic matter and inorganic matter, such as ammonia and heavy metals. The combined treatment of leachate with sewage has been used in various sewage treatment plants in Brazil. However, there are still many questions and uncertainties about the process, especially the effects of adding leachate on the treatment system. In this context, this study aimed at evaluating the efficiency of combined treatment of leachate/sewage in activated sludge under different conditions. In the first stage of this research, treatability experiments were carried out in a bench scale (SBR) using the volumetric proportions of 0% (control), 0.2%, 2% and 5% leachate under different experimental conditions. The Experiment 2 (leachate pretreated by alkalinization and air stripping) was more technically feasible, achieving efficiencies of removal of BOD, COD and DOC above 97, 82, 60%, respectively, until the proportion of 2% pre-treated leachate. In the second stage of the research was evaluated the treatability using pilot-scale reactors (continuous flow) for sewage treatment with 2% (P1) and 0% (P2-control) leachate pretreated. The operational parameters adopted were food-microorganism rate of 0.22 kgDBO/ kgSSV.d, hydraulic retention time of 24 hours and the sludge retention time of 20 days. The results indicated the viability of the combined treatment with 2% leached pretreated, whose average efficiency of removing BOD, COD, DOC were 93, 84 and 60% respectively. This research was developed with financial support (case No. 2010/2-51955) of Fundação de Amparo à Pesquisa de São Paulo (FAPESP).
3

Tratamento consorciado de esgoto sanitário com lixiviados de aterros sanitários, lodo de tanques sépticos e efluentes de sanitários químicos por lodos ativados em batelada na ETE Canoas - CORSAN

Souza, Ândrea Aline Rosa de 31 March 2011 (has links)
Submitted by Mariana Dornelles Vargas (marianadv) on 2015-05-12T12:29:45Z No. of bitstreams: 1 tratamento_consorciado.pdf: 6140063 bytes, checksum: 2e4f0cc893d0de295c3aa7272060c547 (MD5) / Made available in DSpace on 2015-05-12T12:29:45Z (GMT). No. of bitstreams: 1 tratamento_consorciado.pdf: 6140063 bytes, checksum: 2e4f0cc893d0de295c3aa7272060c547 (MD5) Previous issue date: 2011-03-31 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / No Brasil, apenas uma pequena parcela do esgoto sanitário coletado é efetivamente tratado. Entretanto, no âmbito urbano há a geração de outros tipos de efluentes tais como lodos de tanques sépticos, neste caso considerado um efluente devido ao teor de água superior a 90%, efluentes de sanitários químicos e lixiviados de aterro sanitários, todos gerados a partir de atividades urbanas, e que necessitam de tratamento adequado para disposição final. O tratamento consorciado destes efluentes externos com esgoto sanitário tem sido utilizado como estratégia para diminuir os custos no tratamento. No entanto, devido a grande variabilidade de composição e concentração, estes efluentes têm difícil tratabilidade, principalmente em estações convencionais. Ainda não há consenso sobre os impactos provocados por esta mistura de efluentes sobre os processos de tratamento encontrados nas ETE's, nem sobre a proporção segura para a diluição a ser adotada em relação ao esgoto sanitário. A ETE Canoas - CORSAN possui um sistema de lodos ativados operando em batelada, tratando de forma consorciada esgotos sanitários, lixiviados de aterros sanitários, lodos de tanques sépticos e efluentes de sanitários químicos, sem uma quantidade máxima estipulada para o recebimento destes efluentes externos. Nesta pesquisa buscou-se caracterizar a mistura afluente e avaliar o impacto do tratamento combinado sobre as condições operacionais da ETE, bem como o seu desempenho na remoção de matéria orgânica e nutrientes, no período de janeiro de 2009 a agosto de 2010. Verificou-se que o percentual de diluição dos efluentes externos no ES variou entre 2,1% e 11,3% e que a contribuição destes efluentes para a carga total da DQO variou entre 14% e 74%. A composição físico-química da mistura afluente ao reator biológico influenciou na composição da microbiota presente no RSB. O impacto mais freqüentemente observado pela entrada de cargas de choque foi a perda de biomassa, devido a problemas de floculação e sedimentação, como o bulking. A ocorrência de cargas de choque decorrentes da entrada de efluentes externos promoveu um aumento do IVL de 46 mL/g para 287 mL/g, da mesma forma verificou-se um aumento da relação A/M, que passou de 0,42 d-¹ para 0,82 d-¹. Entre os metais pesquisados o Ca, Fe e K foram encontrados em maiores percentuais nas amostras de efluentes externos, correspondendo a 15,8%, 10,4% e 10,1%, respectivamente. Também foram detectados teores de Cu, Zn, Ti, Cr, em menores percentuais. No lodo biológico foram detectados 56% de Fe, 16% de Ca, 10% de Si e 8% de S, adsorvidos nos flocos, além Zn (4%), Cu (3%), Mn (1,5%) e K (1,2%). A exposição freqüente da microbiota a cargas de choque foi o principal efeito a colaborar no decréscimo das eficiências de remoção de SST, DBO5, DQO, Ptotal e N-NH4 +, prejudicando a qualidade do efluente final. A adoção de uma unidade de recebimento e tratamento preliminar dos efluentes externos permitirá um maior controle operacional na dinâmica de recebimento e tratamento dos efluentes externos, melhorando o desempenho da ETE. / In Brazil, only a small portion of domestic wastewater collected is effectively treated. In most cities, the treatment system used is the septage, which have low efficiency and need for maintenance and periodic removal of sludge, which must be properly disposed. In the cities there is the generation of other types of waste such as sludge from septage, in this case considered an effluent as the water content exceeds 90%, effluent from chemical toilet and sanitary landfill leachate, all generated from urban activities, and require adequate treatment to final disposal. The combined treatment of these external effluents with domestic wastewater has been used as a strategy to reduce the cost of tractability. However, the great variability of composition and concentration of this effluents, make it a difficult treatability mixture, especially on conventional plants. There is still no consensus on the impacts caused by this mixture of effluents on the degradation processes commonly found in DWTPs nor on the safe ratio for the dilution to be adopted in regard to domestic wastewater. DWTP Canoas - CORSAN has an activated sludge system operating in batch, there is the combined treatment of domestic wastewater, sludge from septage, effluent from chemical toilet and sanitary landfill leachate, without a maximum amount stipulated for receipt of these external effluent. This study aimed to characterize the influent mixture and assess the impact of combined treatment on the operating conditions of the DWTP, as well as its performance in the removal of organics and nutrients between January 2009 to August 2010. It was found that the percentage of dilution of external effluent in domestic wastewater varied between 2.1% and 11.3% and that the contribution of this effluents to the total COD load varied between 14% and 74%. The physico-chemical composition of the influent mixture to biological reactor has influence on the composition of the microfauna present in the SBR. The most frequently observed impact by the shock loads entry was the loss of biomass due to flocculation and settling problems, such as bulking. The occurrence of shock loads due to the entry of external effluents promoted an increase in the SVL of 46 mL/g to 287 mL/g, just as there was an increase in the F/M, which increased from 0.42 d-¹ to 0.82 d-¹. Among the metals analyzed for Ca, Fe and K were found in higher percentages in the external effluent samples, corresponding to 15.8%, 10.4% and 10.1% respectively. Were also detected for Cu, Zn, Ti, Cr, in low percentages. In biological sludge were detected 56% Fe, 16% Ca, 10% Si and 8% of S, adsorbed on the flocs, and Zn (4%), Cu (3%), Mn (1.5%) and K (1.2%). The frequent exposure of activated slugde community to shock loads was the main effect to collaborate in the removal efficiencies reduction of TSS, BOD5, COD, TP and N-NH4 +, damaging the quality of the final effluent. The adoption of a unit for receiving and preliminary treatment of external effluents could permit a greater operational control in the receiving and treatment dynamic of external effluents, improving the performance of DWTP.

Page generated in 0.1072 seconds