Utilização de filtração direta ascendente como pré-tratamento à filtração rápida descendente para tratamento de água para abastecimento / The use of direct up-flow filtration as a pretreatment for rapid filtration in drinking water productionPaulo Tadeu Ribeiro de Gusmão 19 April 2001 (has links)
Em instalação piloto, de 06/1998 a 10/1999, utilizando-se água natural de superfície com baixas turbidez e cor, foram avaliados dois sistemas de dupla filtração, com pré-tratamento em filtração direta ascendente em areia com taxas de 200 a 360 m3/m2.dia (sistema S01) e em filtração direta ascendente em pedregulho com taxas de 80 a 190 m3/m2.dia (sistema S02) e com tratamento final em filtração rápida descendente com taxas de 115 a 480 m3/m2.dia. As dosagens do coagulante (produto comercial de sulfato de alumínio) foram definidas utilizando-se filtro de laboratório de areia, havendo indicações de coagulação no mecanismo de adsorção, com neutralização parcial de carga. Foram executadas descargas de fundo intermediárias nas unidades de filtração direta ascendente, com significativa redução na perda de carga no meio granular de pedregulho. A turbidez, cor aparente, Fe e Mn totais dos efluentes finais dos sistemas atenderam às Normas Brasileiras para produção de água potável. No sistema S02 o crescimento da perda de carga no meio granular foi menos intenso na unidade de filtração direta ascendente do que no filtro rápido descendente, ocorrendo o inverso no sistema S01, no qual, em alguns ensaios, o filtro rápido descendente mostrou-se desnecessário. As carreiras de filtração foram de 27 a 88 h no sistema S01 e de 14 a 35 h no sistema S02. Em determinados casos, a floculação predominou na unidade de filtração direta ascendente em pedregulho, prejudicando a qualidade do seu efluente. O sistema S02 mostrou-se mais vantajoso que o sistema S01, exceto quando, neste, a filtração rápida descendente foi desnecessária. / Based on me investigation carried out in pilot plant, from June 1998 to October 1999, using natural surface raw water with low turbidity and color, two systems of two-stage filtration have been evaluated. As a pretreatment, the first system (S01) used direct up-flow sand filtration (with filtration rates from 200 to 360 m3/m2.day), and the second system (S02) used direct up-flow roughing filtration (with filtration rates from 80 to 190 m3/m2.day), both with final treatment based on rapid filtration (with filtration rates from 115 to 480 m3/m2.day) The coagulant doses (commercial product of aluminum sulfate) have been established through the use of laboratory scale sand filter, presenting signs of coagulation in the adsorption mechanism, with partial charge neutralization. Intermediate bottom discharges in the direct up-flow filtration units have resulted in significant reduction in thee headloss in gravel granular medium. The turbidity, apparent-color, total iron and manganese concentrations of the final effluents of the systems have attended the Brazilian Standards for drinking water production. The increase of headloss in gravel granular medium in system S02 was smaller in me direct up-fiow filtration unit than in the rapid filter, the opposite occurring in system S01, where some tests have proved lhe rapid filter redundant. The filter runs time were 27 to 88 hours in system S01 and 14 to 35 hours in system S02. In certain cases, flocculation was predominant in the direct up-flow roughing filtration unit, jeopardizing the effiuent quality. System S02 has proved advantageous in relation to system S01, except when in system S01 the rapid filter was redundant.
|
12 |
Avaliação do desempenho de uma estação de tratamento de água com sistema de dupla filtração, em escala real / Evaluation of the performance of the water treatment station with a double filtration system in real scaleJoão Rodrigo Saldanha 28 March 2002 (has links)
A tecnologia de tratamento com dupla filtração encontra-se em estágio relativamente elevado de desenvolvimento, porém, ainda são poucos os dados de operação em escala real. Este trabalho teve como objetivo avaliar um sistema de dupla filtração em escala real (ETA2) para tratamento de água, do serviço autônomo de água e esgoto da cidade de São Carlos - SP, que trata água bruta proveniente do Ribeirão do Feijão e é constituída de três unidades de filtração cada uma contendo um filtro ascendente e um descendente. Em uma primeira etapa foram levantadas as medidas das unidades de dupla filtração, caracterizado o material filtrante e avaliadas as condições operacionais da ETA 2. Posteriormente, foi estudada a situação geral da ETA por meio de diversos parâmetros (turbidez, pH, expansão da areia na lavagem, contagem de partículas, de coliformes totais e Escherichia. coli), para verificar os principais problemas. Em seguida, realizou-se uma comparação da ETA2 com uma Instalação Piloto de Dupla Filtração. Este trabalho permitiu concluir principalmente que: i) devido às baixas taxas de filtração de unidades filtrantes da ETA2, excessivas dosagens de coagulante e falta de controle de lavagens, geralmente foi baixa a produção efetiva de água (em torno de 90%); ii) o desempenho, algumas vezes insatisfatório das unidades de filtração ascendente e descendente, deveu-se principalmente à ineficiência da mistura de coagulante na água bruta, falta de areia nos filtros ascendentes e à diferença de granulometria nos filtros descendentes; iii) o desenvolvimento da perda de carga nos filtros ascendentes da ETA2 foi mais acentuado na Instalação Piloto devido à mistura de seus materiais filtrantes. / Water treatment by means of a double filtration system is in a relatively high stage of development, however, there are still few data on real scale operations. The aim of this work was to evaluate a double filtration system in a real scale (ETA2) for the treatment of water, of the autonomous service of water and sewer of the city of São Carlos - SP, which treats water from the Ribeirão do Feijão (name of a local river), and is constituted of three filtration units, each a contain a direct up-flow sand filter, and a rapid filter. In the first stage, the sand of the filters was characterized, and the operational conditions of the ETA2 were evaluated. Next, the general situation of the ETA was studied by means of several parameters (turbidity, pH, expansion of the sand during washing process, counting of particles, total coliforms and Escherichia coli), in a order to detect the main problems. Finally, a confrontation between the ETA2 an a double filtration pilot Plant was carried through. This study made infer that: I) due to the low filtration rates of the ETA2`s filtration units, excessive doses of coagulant and lack of control of the washings, the actual production of water was low (around 90%); ii) the sometimes insufficient performance of the direct up-flow sand filtration and rapid filtration systems was mainly caused by an inefficient mixing of the coagulant with the natural water, lack of sand in direct up-flow filters; iii) the building up of the lossof cargo in the direct up-flow san filtration in filters of the ETA2 was more accentuated than in the Pilot Plant due to the mixture of the filtration materials.
|
13 |
Influência do gradiente médio de velocidade na zona de contato na eficiência de clarificação de água para abastecimento por flotação / Influence of the velocity gradient in the contact zone in the efficiency of clarification of potable water by flotationIrene Monteiro da Franca Souza 13 September 2012 (has links)
O presente trabalho teve como objetivo estudar a influência do gradiente médio de velocidade (Gzc), associado ao tempo de detenção hidráulico (tzc) e à taxa de aplicação superficial (TASzc), na zona de contato, na eficiência de clarificação de uma unidade retangular de flotação por ar dissolvido, em escala piloto, tratando água para abastecimento. Foram estudadas duas configurações da Unidade Piloto de Flotação por Ar Dissolvido (UPFAD) (A e B), as quais diferem no comprimento da zona de contato A (90 mm) e B (140 mm). A TASzc - A (133 ± 3 m/h) e B (86 ± 1 m/h) - e o tzc - A (54 ± 1s) e B (84 ± 1 s) - são diferentes. Foram avaliados três valores do Gzc A (1,8; 6,5;10,2) e B (0,9; 4,7; 6,3), através da inserção de telas com características diferentes no interior da zona de contato. E, Para cada valor de Gzc, foram investigados três valores de A/V (3,73; 4,90; 6,41). Em todos os ensaios realizados, foram fixados os seguintes parâmetros: vazão da água bruta preparada (5,4 m³/h); temperatura da água bruta preparada (26 ± 1ºC); pH de coagulação (6,5 ± 0,1); tempo de floculação (17,2 min); gradiente médio de velocidade de floculação (110 s-1); vazão de descarte após a floculação (0,8 m³/h); vazão de entrada para a flotação (Qe) (4,6 m³/h); velocidade de entrada para a flotação (ve) (180 m/h); velocidade cross-flow (45 m/h); TASzs (14,6 ± 0,2 m/h); pressão de saturação (4,5 ± 0,1 Kgf/cm²). A unidade piloto FAD foi alimentada com água preparada, que apresentou turbidez em torno de 7,4 ± 0,6 UNT, e cor aparente, em torno de 39,4 ± 4,3 UH. A fração removida dos parâmetros analisados para cada Gzc é menos sensível a variações de A/V na configuração A que na configuração B. Na configuração A, a tela que apresentou Gzc em torno de 6,5 s-1 gerou melhores resultados para cada A/V analisado. Na configuração B, a tela que gerou Gzc em torno de 4,7 s-1 proporcionou melhor fração removida de turbidez e cor para cada A/V estudado. Além disso, na configuração B, a fração removida de turbidez e cor foi menos sensível a variações de A/V, para Gzc de 4,7 s-1 que para os demais valores de Gzc. A tela que gerou resultados mais eficientes na configuração A foi a mesma para a configuração B. Portanto o uso da referida tela favoreceu o desempenho das configurações A e B. Comparando todas as situações estudadas nas duas configurações, o ensaio com a configuração A (com tzc de 54 s) com Gzc de 6,3 s-1 e A/V de 4,9 g/m³, apresentou as maiores frações de remoção de cor e turbidez. / The present work aimed to study the influence of velocity gradient (Gzc) associated with the hydraulic detention time (tzc) and the rate of surface application (TASzc) in the contact zone in the efficiency of clarification of a unit rectangular dissolved air flotation pilot scale, treating water supplies. Two different kinds of configurations of the reactor dissolved air flotation in pilot scale (UPFA) (A and B) were studied, which differ in the length of the contact zone - A (90 mm) and B (140 mm). The TASzc - A (133 ± 3 m/h) and B (86 ± 1 m/h) - and tzc - A (54 ± 1 s) and B (84 ± 1 s) were different. Three different values of Gzc were analysed - A (1.8, 6.5, 10.2 s-1) and B (0.9, 4.7, 6.3 s-1) by insertion of grilles with different characteristics within the zone contact. And for each value of Gzc, three values of A/V (3.73, 4.90, 6.41 g/m³) were investigated. In all trials, the following parameters were set: flow of synthetic raw water (5.4 m³/h), synthetic raw water temperature (26 ± 1ºC), coagulation pH (6.5 ± 0.1); flocculation time (17.2 minutes), the speed gradient flocculation (110 s-1); flow disposal after flocculation (0.8 m³/h), input flow to the flotation (Qe) (4, 6 m³/h), input speed for flotation (ve) (180 m/h), cross-flow velocity (45 m/h), TASzs (14.6 ± 0.2 m/h), saturation pressure (4.5 ± 0.1 kgf/cm ²). The pilot plant was fed with synthetic water, which showed turbidity of approximately 7.4 ± 0.6 NTU, and apparent color, about 39.4 ± 4.3 HU. The removal efficiency of the analyzed parameters for each Gzc is less sensitive to variations in the A/V in the configuration A than in the configuration B. In configuration A, the grille that showed Gzc about 6.5 s-1 gave better results for each A/V analysis. In configuration B, the grille that has generated Gzc around 4.7 s-1 provided the best removal efficiency of turbidity and color for each A/V studied. Furthermore, in the configuration B, the removal efficiency of color and turbidity was less sensitive to variations in A/V for Gzc 4.7 s-1 than for other values of Gzc. The grille that generated the best results in the configuration A was the same for the configuration B. Therefore the use of that grille favored the performance of configurations A and B. Comparing all the situations studied in two configurations, the test with the configuration A (with tzc the 54 s) with Gzc of 6.3 s-1 and A/V of 4.9 g/m³, had the highest removal efficiencies of color and turbidity.
|