• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • No language data
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Travelling Wave Based DC Line Fault Location in VSC HVDC Systems

Karasin Pathirannahalage, Amila Nuwan Pathirana 04 January 2013 (has links)
Travelling wave based fault location techniques work well for line commutated converter (LCC) based high voltage direct current (HVDC) transmission lines, but the large capacitors at the DC line terminals makes application of the same techniques for voltage source converter (VSC) based HVDC schemes challenging. A range of possible signals for detecting the fault generated travelling wave arrival times was investigated. Considering a typical VSC HVDC system topology and based on the study, an efficient detection scheme was proposed. In this scheme, the rate of change of the current through the surge capacitor located at each line terminal is measured by using a Rogowski coil and compared with a threshold to detect the wave fronts. Simulation studies in PSCAD showed that fault location accuracy of ±100 m is achievable for a 300 km long cable and 1000 km long overhead line. Experimental measurements in a practical HVDC converter station confirmed the viability of the proposed measurement scheme.
2

Travelling Wave Based DC Line Fault Location in VSC HVDC Systems

Karasin Pathirannahalage, Amila Nuwan Pathirana 04 January 2013 (has links)
Travelling wave based fault location techniques work well for line commutated converter (LCC) based high voltage direct current (HVDC) transmission lines, but the large capacitors at the DC line terminals makes application of the same techniques for voltage source converter (VSC) based HVDC schemes challenging. A range of possible signals for detecting the fault generated travelling wave arrival times was investigated. Considering a typical VSC HVDC system topology and based on the study, an efficient detection scheme was proposed. In this scheme, the rate of change of the current through the surge capacitor located at each line terminal is measured by using a Rogowski coil and compared with a threshold to detect the wave fronts. Simulation studies in PSCAD showed that fault location accuracy of ±100 m is achievable for a 300 km long cable and 1000 km long overhead line. Experimental measurements in a practical HVDC converter station confirmed the viability of the proposed measurement scheme.

Page generated in 0.1398 seconds