• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise e demonstração do comportamento do escoamento bifásico gás-sólido /

Romero Luna, Carlos Manuel. January 2009 (has links)
Orientador: Luiz Roberto Carrocci / Banca: Maurício Araújo Zanardi / Banca: Marco Aurélio Ferreira / Resumo: O estudo do escoamento bifásico gás-sólido está incluído no assunto referido ao escoamento multifásico. Este tipo de escoamento multifásico é encontrado no transporte pneumático, combustão do carvão, reatores de leito fluidizado e ciclones. O escoamento bifásico gás-sólido é extremamente complicado devido ao grande número de variáveis envolvidas, a interação entre as fases, e a complexa dinâmica que desenvolve durante o processo. Uma das áreas menos entendidas referente ao estudo do escoamento multifásico é a transferência da quantidade de movimento e o acoplamento entre as fases. A proposta desta dissertação é pesquisar aspectos da transferência da quantidade de movimento em um escoamento bifásico gás-sólido vertical descendente sobre a base das equações unidimensionais desenvolvidas para o referido escoamento. Os efeitos dinâmicos entre as fases são analisados considerando um acoplamento unidirecional tendo em conta termos tais como a força de arraste sobre as partículas, a força da gravidade e o atrito partícula-parede. Para a resolução do modelo teórico foi empregado o método Runge-Kutta-Merson. O modelo teórico permite calcular e avaliar a influência das variáveis do escoamento sobre o perfil axial da velocidade média das partículas e também possibilita a determinação de outras variáveis tais como a fração volumétrica de sólidos. Adicionalmente é projetado um sistema de instrumentação para medir a velocidade média das partículas através da medição do tempo médio de trânsito das partículas. Resultado da pesquisa demonstra o complexo comportamento e as dificuldades encontradas no desenvolvimento da instrumentação para esta classe de escoamento. / Abstract: The study of gas-solid two-phase flow is included in a more general subject named as multiphase flow. This kind of multiphase flow is encountered in the pneumatic conveying, combustion of pulverized coal, fluidized bed reactor and cyclones. The gas-solid two-phase flow is extremely complicated because of the large number of variables involved, the interaction between the phases, and complex dynamical developments occurring in the process. One of the least understood areas of multiphase flows is the momentum transfer or the phase coupling. The purpose of this dissertation is to research aspects of momentum exchange on a vertical downward gassolid flow on the basis of one-dimensional equations developed for gas-solid twophase flow. The dynamic effects between the two phases are considered by one way coupling taking into account terms such as the drag force on the particles, gravity and the particle-wall frictions. For the solution of theoretical model the Runge-Kutta- Merson method was employed. The theoretical model allows to calculate and to evaluate the influence of the flow variables on the axial profile for the average velocity of particles and also enables the determination of other variables such as the solid hold-up. Also it is designed an experimental system to measure the average velocity of particles by measuring the average time of transit of them. The results show the complex behavior and the difficulties in developing instrumentation for this class of flow. / Mestre
2

Simulação computacional do escoamento bifásico com formação de espuma da mistura óleo-refrigerante R134a ao longo de um tubo reto de seção circular constante /

Dias, João Paulo. January 2006 (has links)
Orientador: José Luiz Gasche / Banca: André Luiz Seixlack / Banca: Adriano da Silva / Resumo: Este trabalho apresenta um estudo numérico do escoamento bifásico com formação de espuma de uma mistura composta por óleo lubrificante sintético Freol a10 com pequenas quantidades de refrigerante R134a, usualmente encontrada em compressores de sistemas de refrigeração e ar condicionado. A geometria considerada é um tubo longo horizontal de seção circular constante. Em razão da queda de pressão inicialmente causada pelas forças de atrito viscoso, a solubilidade do refrigerante no óleo diminui e o refrigerante evapora da mistura líquida formando bolhas de gás que escoam com a fase líquida. A formação de bolhas de refrigerante pode ser tão intensa a ponto de o escoamento assumir a forma de espuma quando a fração de vazio atinge valores superiores à aproximadamente 70%. Um ponto importante com relação ao escoamento de espuma é que o seu comportamento é muito diferente dos escoamentos bifásicos convencionais, apresentando quedas de pressão bem superiores. Os resultados gerados para as distribuições de pressão e temperatura ao longo do escoamento são confrontados com dados experimentais para a validação do modelo numérico. Será verificado que o modelo representa satisfatoriamente os resultados experimentais para várias condições do escoamento. / Abstract: This work presents a numerical study of the two-phase flow with foam formation of a mixture composed by synthetic lubricant oil Freol a10 with small amounts of refrigerant R134a, usually encountered in compressors of refrigeration and air conditioning systems. A straight horizontal tube with circular cross section was chosen to accomplish the simulation. Due to the pressure drop initially caused by the viscous friction forces, the refrigerant solubility in the oil reduces and the refrigerant evaporates from the liquid mixture (outgassing) forming gas bubbles that flow with the liquid phase. In this type of flow, the bubble formation can be so large that foam is formed as the void fraction reaches values above 70%. An important point with reference to foam is that the foam flow behavior is much different from the conventional two-phase flows, presenting larger pressure drops. Results for pressure and temperature distributions along the flow are compared with experimental data in order to validate the numerical model. It will be seen that the model represents satisfactorily the experimental results for many flow conditions. / Mestre
3

Análise numérica de condensadores do tipo arame-sobre-tubo usados em refrigeradores domésticos /

Lima, Rafael Sene de. January 2008 (has links)
Orientador: André Luiz Seixlack / Banca: Emanuel Rocha Woiski / Banca: José Roberto Simões Moreira / Resumo: Neste trabalho apresenta-se um modelo numérico para a simulação do escoamento transiente de fluidos refrigerantes ao longo de condensadores do tipo arame-sobre-tubo, comumente usados em refrigeradores domésticos que empregam o ciclo de compressão de vapor. A análise envolve o escoamento do fluido refrigerante no interior do tubo e a transferência de calor por convecção natural e radiação entre a superfície externa do tubo, as aletas em forma de arames cilíndricos e o ar externo. No interior do tubo o escoamento é considerado unidimensional e dividido em uma região monofásica de vapor superaquecido, uma região bifásica líquido-vapor e outra em que o refrigerante encontra-se no estado de líquido subresfriado. A queda de pressão no interior do tubo é também considerada. Na região bifásica o escoamento é considerado homogêneo, ou seja, são consideradas condições de equilíbrio térmico e hidrodinâmico entre as fases. Inicialmente, condições de regime permanente serão assumidas e posteriormente será analisada a resposta dinâmica do condensador às variações das condições de operação do sistema. A simulação do escoamento ao longo do condensador é obtida a partir da solução numérica das equações de conservação da massa, da quantidade de movimento e de conservação de energia. Para a parede do condensador, a equação de conservação de energia é resolvida para determinar a sua distribuição de temperatura. O método de Volumes Finitos é usado na discretização das equações governantes. O modelo permite a determinação, nos regimes permanente e transiente, das distribuições de pressão, título, temperatura do refrigerante e temperatura do tubo ao longo do condensador, em função da geometria do condensador e das condições de operação. O modelo proposto é analisado e os resultados obtidos são discutidos e comparados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work presents a numerical model to simulate the unsteady refrigerant fluid flow along wire-on-tube condensers, commonly used in vapor compression cycle based domestic refrigerators. The model considers the refrigerant flow inside the tube and the heat transfer from the outer surfaces of the wires and tubes to the surrounding air by free convection and radiation. The refrigerant flow along the condenser is divided into a vapor superheated singlephase region, a two-phase liquid-vapor flow region and a subcooled liquid region. The refrigerant pressure drop is taking into account. The homogeneous model is employed for the two-phase flow region, i.e. the hydrodynamic and thermal equilibrium between the phases are considered. Initially the steady state condition is considered and later condenser unsteady behavior is analyzed. The mass conservation, momentum and energy conservation equations for the refrigerant flow are solved in order to evaluate the distributions of mass flux, pressure and temperature of the refrigerant fluid, respectively. Also, the energy conservation equation for the tube wall is solved to determine the wall temperature distribution. The system of differential equations is solved using the Finite Volume method. The model is analyzed and the obtained results are compared with data available in the open literature. / Mestre
4

Simulação do escoamento bifásico da mistura óleo-refrigerante através da folga radial de compressores rotativos de pistão rolante /

Ferreira, Adriano Domingos. January 2006 (has links)
Orientador: José Luiz Gasche / Banca: André Luiz Seixlack / Banca: Paulo Eduardo Lopes Barbieri / Resumo: Devido à solubilidade mútua entre o fluido refrigerante e o fluido lubrificante usados em sistemas de refrigeração por compressão de vapor, eles formam uma mistura homogênea que influencia tanto os processos de transferência de calor no evaporador e no condensador, como os processos de lubrificação e de selagem de vazamentos no interior do compressor. O vazamento de refrigerante através da folga radial de compressores rotativos de pistão rolante é de particular importância para o bom desempenho do compressor, uma vez que ele influencia significativamente a eficiência volumétrica do compressor, chegando a somar cerca de 30% das perdas totais de refrigerante. No presente trabalho foram desenvolvidos modelos de escoamento de misturas óleo-refrigerante através desta folga, incluindo a mudança de fase do refrigerante devida à variação da sua solubilidade no lubrificante. A solução da equação da energia constitui uma evolução do processo de modelagem deste escoamento em relação aos modelos até então desenvolvidos. Quatro modelos diferentes foram usados para simular o escoamento: modelo de escoamento bifásico homogêneo isotérmico, modelo de escoamento bifásico isotérmico com formação de espuma, modelo de escoamento bifásico homogêneo não-isotérmico e modelo de escoamento bifásico homogêneo não-isotérmico com termo de força inercial. O estudo foi realizado para três misturas óleo-refrigerante: óleo éster Freol a10 e refrigerante R134a, óleo éster EMKARATE RL10H e refrigerante R134a e óleo mineral SUNISO 1 GS e refrigerante R12. Para todos os modelos e misturas, realizou-se um estudo paramétrico envolvendo as principais variáveis do problema: pressão de entrada, temperatura de entrada, vazão de mistura e valor da folga mínima... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Due to the mutual solubility between the refrigerant and lubricant of refrigeration systems using mechanical compression of vapor, they form a homogeneous mixture which influences the heat transfer processes in the evaporator and condenser as well as the compressor lubrication and refrigerant leakage. The refrigerant leakage through the radial clearance of rolling piston compressors plays an important role to the volumetric efficiency in this type of compressor, in which it represents about 30% of the total refrigerant loss. In the present work several models to predict the lubricant-refrigerant mixture flow through this clearance, including the refrigerant phase change due to the reduction of the refrigerant solubility in the lubricant, are developed. Four different models were developed to simulate the flow: isothermal homogeneous two-phase flow, isothermal two-phase flow with foam formation, non-isothermal homogeneous two-phase flow and non-isothermal homogeneous two-phase flow containing inertial force. The simulations were performed for three mixtures: ester oil Freol a10-refrigerant R134a, ester oil EMKARATE RL10H-refrigerant R134a, and mineral oil SUNISO 1 GS-refrigerant R12. The influences of the inlet pressure, inlet temperature, mixture mass flow rate, and minimal clearance were analyzed for all mixtures. The results showed that it is important to consider the foam formation, the inertial force, and the solution of the energy equation in the flow modeling. Concerning the volumetric efficiency of the compressor the ester oil Freol a10-R134a was the best mixture because it produced the lowest refrigerant leakage. / Mestre
5

Estudo experimental do funcionamento de um sistema gas-lif /

Mendes, Fernando Augusto Alves. January 2007 (has links)
Resumo: O princípio de funcionamento de um sistema gas-lift é bastante simples, baseando-se na injeção de um gás inerte próximo à extremidade submersa de um tubo utilizado para ascensão do líquido (riser). Esse sistema tem sido utilizado em diversos setores da indústria, dentre os quais se destaca o setor petroquímico. Apesar de ter sido concebido há mais de um século, e a despeito do considerável número de artigos publicados sobre o assunto, vários aspectos relativos às características do escoamento bifásico dentro do riser e ao funcionamento do sistema são, ainda, pouco conhecidos. No presente trabalho, um sistema air-lift de pequeno porte foi inteiramente desenvolvido e testado, permitindo observar o comportamento do sistema quando submetido a variações na vazão de ar, na razão de submersão e na geometria do injetor - contendo três (3F) ou quinze furos (15F). Ensaios de visualização foram conduzidos, possibilitando a caracterização do escoamento bifásico no interior do riser. Medições experimentais foram, também, realizadas para a obtenção da eficiência e das curvas características do sistema. Os resultados quantitativos foram interpretados em associação com imagens estáticas do escoamento, capturadas com uma câmera fotográfica digital, e com imagens dinâmicas, tomadas com o auxílio de uma filmadora de alta velocidade. A partir destas imagens, foi possível, ainda, a estimativa de alguns importantes parâmetros característicos do escoamento pistonado, associados ao deslocamento da chamada bolha de Taylor. Os dados assim obtidos foram comparados com valores oriundos de correlações empíricas propostas por outros autores, apresentando boa concordância. Com relação aos resultados quantitativos, observou-se que, sob determinadas condições de operação, o injetor 3F é capaz de atribuir ao sistema um rendimento significativamente maior... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The operation principle of a gas-lift system is very simple: it is based on the injection of an inert gas close to the immersed edge of a tube, which is used for the rising of the liquid (riser). This system has been used in several industrial areas and more often in the petrochemical industry. Despite the fact that it was conceived over a century ago and that there have been a considerable amount of articles published on the subject, several aspects concerning the two-phase flow characteristics inside the riser as well as its operational system are still not very well known. In the present work, a small size air-lift system was thoroughly developed and tested, which facilitated the visualization of the system behavior when submitted to variations in the air flow, the immersion ratio and the injector geometry - containing three (3H) or fifteen holes (15H). Observation experiments were carried out making it possible to characterize the two-phase flow inside the riser. Experimental measurements were also taken in order to obtain the system characteristic efficiency and slopes. The quantitative results were analyzed together with the statistic images of the flow - taken by a digital photo camera, and with the dynamic images - taken by a high-speed filming camera. Through these images, it was also possible to estimate some important characteristic parameters of the slug flow associated to the displacement of the so-called Taylor bubble. The data obtained this way were compared to the figures originated from experimental correlations proposed by other authors, and they showed a fine agreement. Regarding the quantitative results, it was observed that under certain operation conditions the 3F injector is able to give the system a significantly greater efficiency than when the 15F injector is used / Orientador: Sérgio Said Mansur / Coorientador: Edson Del Rio Vieira / Banca: André Luiz Seixlack / Banca: Ricardo Augusto Mazza / Mestre

Page generated in 0.0863 seconds