• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 22
  • 5
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 74
  • 16
  • 15
  • 14
  • 12
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A UBV-suscetibilidade na presença da infecção pelo HIV : um estudo caso-controle em hospital de referência para o atendimento de portadores do vírus HIV

Elisabete Simões de Sousa, Ana January 2003 (has links)
Made available in DSpace on 2014-06-12T18:31:37Z (GMT). No. of bitstreams: 2 arquivo8064_1.pdf: 1214263 bytes, checksum: 18b18127f2abdd1757d1904cd7640417 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / A radiação ultravioleta é capaz de modificar a resposta imunológica cutânea nos animais e no homem e, desta forma, interferir no comportamento das infecções e neoplasias. Seus efeitos imunológicos se apresentam de maneira desigual nos indivíduos e, dentre os fatores genéticos que parecem determinar esta desigualdade, cita-se o fenótipo de UVB-suscetibilidade. O dinitroclorobenzeno é um potente agente sensibilizante de contato que estimula a imunidade celular quando aplicado à pele. Como a radiação ultravioleta altera a resposta imunológica cutânea ao dinitroclorobenzeno, este agente vem sendo usado para investigar os mecanismos de ação da radiação solar no sistema imune cutâneo. Um estudo do tipo caso-controle foi realizado para determinar a frequência de UVB-suscetibilidade na população do estudo e tentar estabelecer uma associação com infecção pelo HIV e parâmetros laboratoriais de imunidade nestes indivíduos. Foram selecionados 50 casos e 50 controles de acordo com a sorologia para o HIV, atendidos nos ambulatórios do Hospital das Clínicas, no período de março de 2002 a janeiro de 2003. Os pacientes foram submetidos à irradiação ultravioleta B na pele para determinação da dose eritematosa mínima. No local da pele irradiado foi aplicado o dinitroclorobenzeno a 2% para provocar uma sensibilização. Após 3 semanas foi aplicado o dinitroclorobenzeno a 0.05% para obtenção do fenótipo de UVB-suscetibilidade. Os pacientes que apresentaram reação positiva a este antígeno foram considerados UVBresistentes e aqueles que não apresentaram tal reação foram considerados UVB-suscetíveis. A UVB-suscetibilidade foi significativamente maior no grupo de pacientes infectados pelo HIV (x2 = 9.24 e p = 0.002), estando presente em 70% dos casos e 40% dos controles. Dentre os casos, observou-se que os indivíduos com AIDS tinham maiores índices de UVB-suscetibilidade (71.4%) (x2 = 14.27 e p = 0.000 ). Este estudo concluiu que nos indivíduos infectados pelo HIV os índices de UVBsuscetibilidade foram maiores que no grupo controle, com significância estatística. Dentre os soropositivos, a UVB-suscetibilidade foi mais prevalente nos pacientes com AIDS. Sugere-se, então, que a UVB-suscetibilidade pode-se constituir em um fator de risco para o desenvolvimento de formas mais graves da doença em indivíduos infectados por este vírus
2

Uma contribuição para circuitos eletrônicos de medidores de radiações ultravioleta para lentes / A contribution to electronic circuits of ultraviolet radiation meters lens

Oliveira, Gunter Camilo Dablas de 07 August 2009 (has links)
O propósito deste trabalho foi o desenvolvimento de um sistema para medir a transmissão das radiações no intervalo 290nm - 380nm, em lentes oftálmicas. O protótipo é um dispositivo opto-eletrônico, composto por uma fonte de ultravioleta; dois sensores de radiação - UVA e UVB (fotodiodos); um circuito eletrônico para a realização das medidas e um mostrador para fornecer o resultado. Quando o sistema é ligado, a fonte emite a radiação ultravioleta, e os dois sensores captam os respectivos sinais, no intervalo de UVA e UVB e armazenam estes dados. Ao se colocar uma lente para ser testada, os sensores recebem novamente o sinal e dividem pelo sinal armazenado, fornecendo assim, a porcentagem de luz ultravioleta transmitida pela lente. Os sinais provenientes dos fotodiodos são amplificados de modo que transformam uma baixa corrente em tensão (na faixa de milivolts), que por sua vez é amplificada para um fundo de escala com tensão máxima igual a 5VCC. O sinal obtido na saída dos amplificadores é enviado para um conversor analógico digital (A/D); o sinal digital é enviado para um microcontrolador AT89S52, que foi programado para ler dados do conversor A/D, ler teclas e proporcionar o laudo escrito em um display. Polarizadores calibradores e lentes de óculos foram testados no sistema desenvolvido e as medidas comparadas com o espectro de transmissão em um espectrofotômetro Cary 17 - VARIAN. O fator de correlação entre os dois sistemas foi de 0,82. O circuito digital apresenta uma imprecisão menor do 1% nas medidas. Isto tem a implicação direta no fator de correlação entre este protótipo e o espectrofotômetro. As flutuações da lâmpada também contribuem para a imprecisão, uma vez que a repetibilidade do sistema é de 90%, em 20 medidas de uma mesma lente. Sendo assim, este protótipo é capaz de medir a proteção ultravioleta em lentes de óculos, com uma precisão de 2%. Modificações do sistema serão implementadas no futuro, para que medidas com precisão de 0,5% sejam atendidas, em protótipo para uso clínico. / The purpose of this work is the development of a system for measuring the transmission of radiation at 290nm - 380nm range of ophthalmic spectacles. The prototype is an optoelectronic device, assembled by ultraviolet radiation source; two ultraviolet sensors UVA and UVB (photodiodes); an electronic circuit and a display, as a user interface, for providing the reports. As the illumination system is turned on, the sensors receive their respective voltage signals, at the UVA and UVB range, and store the data. As a spectacle is placed for testing, the sensors collect the data from the signal and divide them by the previous data stored, providing the percentage of ultraviolet radiation transmitted by the spectacles. The electronic signals delivered by the photodiodes are amplified in order to convert a low intensity current into voltage (order of milivolts), which is then amplified into a 5Vcc scale. The output voltage of the amplifiers is sent to na A/D converter; the digital signal is sent to a microcontroller AT89S52, which is then programmed for reading the data of the converter; reading the keyboard and providing the report on a display. Calibrating polarizers and spectacles have been tested in the developed system and the data have been compared to the transmission spectrum of a spectrophotometer Cary 17 - VARIAN. The correlation factor was 0.82. The electronic digital circuit presents an error lesser than 1%. This has a straight relation on the correlation factor between the prototype and the spectrophotometer. Output fluctuations of the light source add extra inaccuracy on the system, since the repetitivity of the measurements is 90%, for 20 measurements of the same spectacle. Hence, the prototype is capable of measuring the ultraviolet protection of spectacles, with a 2% precision. Modifications on the system should be implemented in a near future, in order to provide 0.5% accuracy, and then be released for clinical use.
3

Uma contribuição para circuitos eletrônicos de medidores de radiações ultravioleta para lentes / A contribution to electronic circuits of ultraviolet radiation meters lens

Gunter Camilo Dablas de Oliveira 07 August 2009 (has links)
O propósito deste trabalho foi o desenvolvimento de um sistema para medir a transmissão das radiações no intervalo 290nm - 380nm, em lentes oftálmicas. O protótipo é um dispositivo opto-eletrônico, composto por uma fonte de ultravioleta; dois sensores de radiação - UVA e UVB (fotodiodos); um circuito eletrônico para a realização das medidas e um mostrador para fornecer o resultado. Quando o sistema é ligado, a fonte emite a radiação ultravioleta, e os dois sensores captam os respectivos sinais, no intervalo de UVA e UVB e armazenam estes dados. Ao se colocar uma lente para ser testada, os sensores recebem novamente o sinal e dividem pelo sinal armazenado, fornecendo assim, a porcentagem de luz ultravioleta transmitida pela lente. Os sinais provenientes dos fotodiodos são amplificados de modo que transformam uma baixa corrente em tensão (na faixa de milivolts), que por sua vez é amplificada para um fundo de escala com tensão máxima igual a 5VCC. O sinal obtido na saída dos amplificadores é enviado para um conversor analógico digital (A/D); o sinal digital é enviado para um microcontrolador AT89S52, que foi programado para ler dados do conversor A/D, ler teclas e proporcionar o laudo escrito em um display. Polarizadores calibradores e lentes de óculos foram testados no sistema desenvolvido e as medidas comparadas com o espectro de transmissão em um espectrofotômetro Cary 17 - VARIAN. O fator de correlação entre os dois sistemas foi de 0,82. O circuito digital apresenta uma imprecisão menor do 1% nas medidas. Isto tem a implicação direta no fator de correlação entre este protótipo e o espectrofotômetro. As flutuações da lâmpada também contribuem para a imprecisão, uma vez que a repetibilidade do sistema é de 90%, em 20 medidas de uma mesma lente. Sendo assim, este protótipo é capaz de medir a proteção ultravioleta em lentes de óculos, com uma precisão de 2%. Modificações do sistema serão implementadas no futuro, para que medidas com precisão de 0,5% sejam atendidas, em protótipo para uso clínico. / The purpose of this work is the development of a system for measuring the transmission of radiation at 290nm - 380nm range of ophthalmic spectacles. The prototype is an optoelectronic device, assembled by ultraviolet radiation source; two ultraviolet sensors UVA and UVB (photodiodes); an electronic circuit and a display, as a user interface, for providing the reports. As the illumination system is turned on, the sensors receive their respective voltage signals, at the UVA and UVB range, and store the data. As a spectacle is placed for testing, the sensors collect the data from the signal and divide them by the previous data stored, providing the percentage of ultraviolet radiation transmitted by the spectacles. The electronic signals delivered by the photodiodes are amplified in order to convert a low intensity current into voltage (order of milivolts), which is then amplified into a 5Vcc scale. The output voltage of the amplifiers is sent to na A/D converter; the digital signal is sent to a microcontroller AT89S52, which is then programmed for reading the data of the converter; reading the keyboard and providing the report on a display. Calibrating polarizers and spectacles have been tested in the developed system and the data have been compared to the transmission spectrum of a spectrophotometer Cary 17 - VARIAN. The correlation factor was 0.82. The electronic digital circuit presents an error lesser than 1%. This has a straight relation on the correlation factor between the prototype and the spectrophotometer. Output fluctuations of the light source add extra inaccuracy on the system, since the repetitivity of the measurements is 90%, for 20 measurements of the same spectacle. Hence, the prototype is capable of measuring the ultraviolet protection of spectacles, with a 2% precision. Modifications on the system should be implemented in a near future, in order to provide 0.5% accuracy, and then be released for clinical use.
4

Obtenção e análise de espectros de absorção de luz por herbicidas / Obtaining and analyzing light absorption spectra by herbicides

Dadazio, Tais Santo 18 December 2018 (has links)
Submitted by TAÍS SANTO DADAZIO (tais.dadazio@hotmail.com) on 2019-02-01T16:10:33Z No. of bitstreams: 2 Tese final Tais Dadazio.pdf: 4158225 bytes, checksum: b61bf98b0af058fb81b5f3bf8c5f22d5 (MD5) Tese final Tais Dadazio.pdf: 4158225 bytes, checksum: b61bf98b0af058fb81b5f3bf8c5f22d5 (MD5) / Approved for entry into archive by Maria Lucia Martins Frederico null (mlucia@fca.unesp.br) on 2019-02-01T16:44:07Z (GMT) No. of bitstreams: 1 dadazio_ts_dr_botfca.pdf: 4158225 bytes, checksum: b61bf98b0af058fb81b5f3bf8c5f22d5 (MD5) / Made available in DSpace on 2019-02-01T16:44:08Z (GMT). No. of bitstreams: 1 dadazio_ts_dr_botfca.pdf: 4158225 bytes, checksum: b61bf98b0af058fb81b5f3bf8c5f22d5 (MD5) Previous issue date: 2018-12-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Cada substância apresenta um padrão de resposta específico quando submetidas à radiação solar. No entanto, estudos que comparam diferentes moléculas, a fim de identificarem padrões de comportamento são escassos. Portanto, estudos que relacionam o padrão de absorbância com a radiação solar disponível, buscando estimar o potencial de fotodegradação de defensivos, são inexistentes na literatura. Nesse contexto, esse trabalho estudou a absorção de luz por diferentes herbicidas e metabólitos com o objetivo de prever a sensibilidade desses compostos à fotólise em condições de campo e a necessidade de utilizar manejos ou tecnologias que possam reduzir a degradação por efeito da luz. Foram investigadas 36 substâncias, correspondendo a herbicidas e seus metabólitos. Cada solução foi analisada por meio de varredura das absorbâncias das substâncias na faixa de 185 a 900nm (Ultravioleta (UV)/ Visível (VIS)/Infra vermelho(IF)). Posteriormente, o potencial de cada comprimento de onda em promover a fotólise de um composto específico foi determinado multiplicando-se a disponibilidade de luz no espectro solar padrão e a absorbância observada na solução padronizada desse composto no mesmo comprimento de onda. De acordo com os resultados, cada substância apresentou faixas de comprimento de ondas com maior potencial de absorção, especialmente na região do VIS e com outros estudos permitirão avaliar quais compostos podem ser utilizados para protegê-las. Assim, foi possível agrupar as substancias em relação ao índice de fotodegradação em ordem decrescente na faixa de radiação do UVA, UVB e UVC. Os herbicidas pendimenthalin e trifluralin se destacam por absorverem expressivamente luz visível (400 a 700 nm). / Each substance has a specific response pattern when subjected to solar radiation. However, studier comparing differente molecules in order do identify behavior patterns are scarce. Therefore, studies that relate the absorbance pattern to the available solar radiation, seeking to estimate the photodegradation potential of pesticides are not available in the literature. In this context, this work studied the absorption of light by different herbicides and metabolites in order to predict the sensitivity of these compounds to photolysis underf field conditions and the need to use care or technologies that can reduce light degradation. There were investigated 36 substances, corresponding to herbicides and thei metabolites. Each solution was analyzed by scanning the absorbances of substances in the range of 185 to 900 nm (UV/VIS/IF). Subsequently, the potential of each wavelength promoting the photolysis of a specific compound was determined by multiplying the light availability in the standard solar spectrum and the observed absorbance in the standard solution of that compound at the same wavelenght. According to the results, each substance showed wavelenght ranges with greater absorption potential, and with other studier, it will be possible to evaluate which compounds can be used to protect them. Thus, it was possible to group the substances in relation to the photodegradation index in descending order in the UVA, UVB and UVC radiation range. The herbicides pendimenthalin and trifluralin stand out by expressively absorbing visible light (400 to 700 nm). / CAPES 001
5

Pulsed radiation studies of photo-protective systems

Mulroy, Louise January 1997 (has links)
No description available.
6

The effects of the sunscreen chemicals Padimate-O and 2-ethylhexyl-P-methoxycinnamate on DNA

Gulston, Melanie Katharine January 1999 (has links)
No description available.
7

Photodegradation of the neurotoxicant methylmercury (MeHg) in Swedish lakes

Hilmarsson, Torfi Geir January 2016 (has links)
No description available.
8

How geography influences complex cognitive ability

Universidad Peruana de Ciencias Aplicadas (UPC), León, Federico R., Burga León, Andrés 20 May 2015 (has links)
federicorleone@gmail.com / Evolutionary explanations for geography's influence on complex cognitive ability (CCA) imply virtually immutable components of between-nation IQ differences. Their weight vis-à-vis the weight of situational components was evaluated through an analysis of a 194-country data set. Additive effects of absolute latitude (AL) and longitudinal distance from Homo sapiens' cradle (LDC) explain Northeastern Asian higher, Sub-Saharan African lower CCAs. AL exerts cognitive influence directly and through socioeconomic development and evolutionary genetics whereas LDC does through evolutionary genetics; however, this occurs differently in Africa-Near East- Europe and elsewhere. The findings are understood assuming supremacy of contemporary UVB radiation → hormonal and climatic → socioeconomic mediators of the AL–CCA linkage whose effects are moderated by heterogeneous genetic and cultural adaptations to radiation and climate. Geography's cognitive effects are dynamic and public-policy actions may modify them. / Funds for this researchwere provided by the Vicerrectorado de Investigación through the Research Center at Universidad San Ignacio de Loyola (USIL), Lima, Peru. We are indebted to Romain Wacziarg for making available to us the Spolaore- Wacziarg tables on genetic distance and Edvard Avilés for comments to an earlier version of the paper. FRL designed the study, drafted the manuscript, performed part of the analyses, and interpreted the findings. ABL performed the path analyses and approved the manuscript. The data set utilized in the research has been positioned at USIL's Repository and can be accessed through the following link: http://repositorio.usil.edu. pe/jspui/handle/123456789/1038. / Revisión por pares
9

Exploring Ultraviolet B Radiation in the Landscape

Cox, Victoria S.K. 18 April 2013 (has links)
Ultraviolet B (UVB) radiation from the sun is the chief cause of skin cancer and is also involved in the development of Vitamin D in humans. This poses an interesting challenge, especially for people living in locations at mid to high latitudes. Through an integrative research review and controlled testing the amount of UVB humans receive in the landscape has been explored. Two existing computer models along with personal dosimeter badges were used to evaluate how much UVB students at a school in Waterloo, Ontario received under various conditions in February, 2013. Results showed that it is possible to get the equivalent of 1000 I.U. of vitamin D in February in Waterloo under ideal weather conditions, but not in most conditions. With this information, a guide has been created to optimize UVB for outdoor spaces in all seasons that children may use in northern climates. The design guide includes a summary of the geophysical variables that affect how much UVB reaches the earth’s surface and key concepts to understand including the difference between diffuse and direct radiation. This study provides evidence-based research in the area of climate responsive landscape architecture. / Landscape Architecture Canada Foundation
10

<>.

Martel, Kellie Clay. January 2008 (has links)
Thesis (M.S.)--Indiana University, 2008. / Title from screen (viewed on August 28, 2009). Department of Pathology and Laboratory Medicine, Indiana University-Purdue University Indianapolis (IUPUI). Advisor(s): Raymond L. Konger, Jeffrey B. Travers, Dan F. Spandau. Includes vita. Non-Latin script record Includes bibliographical references (leaves 32-36).

Page generated in 0.0296 seconds